Loading...
A0.0 - A6.1_Saty Paw Permit SetPERMIT SET - CONSTRUCTION DOCUMENTS DATE: 03.12.2019 THE SALTY PAW SPA & WOOF WASH - 603 DARTMOUTH ST. SOUTH DARTMOUTH, MA, 02747 kathryn duff ra cphc A 0.0 HF INSUL MTL NTS PT PTD SCWV SPF SS SSM STL SYP TYP U.N.O. VIF WD WWF Hem-Fir Insulation Metal Not To Scale Pressure Treated Painted Solid Core Wood Veneer Spruce Pine Fir Stainless Steel Solid Surfacing Material Steel Southern Yellow Pine Typical Unless Noted Otherwise Verify In Field Wood Welded Wire Fabric Above Finish Floor Aluminum Beam Centerline Column Concrete Continuous Double Elevation Equal Existing Finish Floor Foundation Face of Foundation Face of Stud Galvanized Glass Gypsum Board GENERAL ABBREVIATIONS: AFF ALUM BM CL COL CONC CONT DBL EL EQ EXISTG FF FNDN FOF FOS GALV GL GYP studio2sustain inc - 2019 COPYRIGHT: THESE PLANS, IDEAS, DRAWINGS, DESIGNS, ARRANGEMENTS AND ANY RELATED DOCUMENTS ARE TO REMAIN THE SOLE PROPERTY OF THE studio2sustain inc AND ARE NOT TO BE USED, REUSED, REPRODUCED OR PUBLISHED, IN WHOLE OR IN PART, WITHOUT EXPRESS, WRITTEN PERMISSION OF THE studio2sustain inc AND KATHRYN DUFF. PROJECT SUMMARY: PROJECT: RENOVATION OF THE EXISTING ONE-STORY MASONRY BUILDING, LOCATED AT 603 DARTMOUTH ST, DARTMOUTH, MASSACHUSETTS. THE SCOPE OF WORK INCLUDES RENOVATION OF EXISTING INTERIOR FIRST FLOOR SPACE, NEW ROOF TRUSS AND ROOF, NEW ELECTRIC, PLUMBING AND HEATING SYSTEMS. LOCATION: 603 DARTMOUTH ST, DARTMOUTH, MA ZONING CLASSIFICATION: MUB, MIXED USE BUSINESS USE GROUP CLASSIFICATION: B: BUSINESS CONSTRUCTION CLASSIFICATION: TYPE IV 603 DARTMOUTH ST IS A MASONRY WALL AND WOOD TRUSS-ROOF AND SLAB ON GRADE. EXPOSURE CATEGORY: URBAN WIND BORNE DEBRIS REGION: 115 mph BASIC WIND SPEED ARCHITECT: KATHRYN DUFF, studio2sustain inc, 412 COUNTY STREET, NEW BEDFORD, MA 02740. OFFICE: 508.999.5145, FAX: 508.999.5183, MA RA #7778 GENERAL NOTES: 1. ALL WORK, AS DEFINED OR IMPLIED WITHIN THESE CONSTRUCTION DRAWINGS AND BUILDING SPECIFICATIONS IS TO BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE, AND NATIONAL BUILDING CODES AND REGULATIONS. 2. ALL DIMENSIONS SHOWN REPRESENT APPROXIMATE DELINEATIONS AND ARE NOT INTENDED TO BE USED FOR CONSTRUCTION PURPOSES. ALL WIDTH DIMENSIONS ARE APPROXIMATE, AS WALLS ARE UNEVEN PLASTER, STONE AND/OR BRICK MASONRY. ALL DIMENSIONS MUST BE VERIFIED IN FIELD (V.I.F.) 3. THE CONTRACTOR SHALL EXAMINE THE ENTIRE SITE, AND WILL TAKE INTO ACCOUNT ALL CONDITIONS THEREON AS MAY AFFECT THE PERFORMANCE OF THE WORK UNDER THE CONTRACT. ALL DIMENSIONS MUST BE VERIFIED IN-FIELD PRIOR TO COMMENCING WORK. CONTRACTOR TO NOTIFY ARCHITECT OF ANY DISCREPANCIES AND/OR DEVIATIONS FROM WHAT IS PRESENTED AND/OR IMPLIED ON THESE DRAWINGS AND SPECIFICATIONS. 4. ALL REPAIR OF EXISTING BRICK TO BE EXECUTED IN STRICT ACCORDANCE WITH THE SECRETARY OF INTERIOR STANDARDS FOR REHABILITATION AND WITH THE SPECIFICATIONS AND CONSTRUCTION DRAWINGS. 5. THESE DRAWINGS ARE INTENDED TO SHOW THE EXISTING CONDITIONS OF THE EXISTING BUILDING, INCLUDING PROPOSED REPAIRS AND RENOVATIONS. ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN FIELD. DO NOT SCALE DRAWINGS. CONTRACTOR TO NOTIFY THE ARCHITECT AND THE OWNER IF ANY CONDITIONS APPEAR CONTRARY TO THE DRAWINGS AND/OR SPECIFICATIONS. 6. THE ARCHITECT AND THE ARCHITECT'S CONSULTANTS SHALL HAVE NO RESPONSIBILITY FOR THE IDENTIFICATION, DISCOVERY, PRESENCE, HANDLING, REMOVAL OR DISPOSAL OF, OR EXPOSURE OF PERSONS TO HAZARDOUS MATERIALS IN ANY FORM AT THE PROJECT SITE. LOCUS MAP - 603 DARTMOUTH ST, DARTMOUTH, MA. 02747 NORTH DRAWING LIST: A0.0 PROJECT SUMMARY, PROJECT SUSTAINABILITY NARRATIVE, VAPOR CONTROL MEMBRANE DIAGRAM A-1.1 PLAN 1ST FLOOR - EXISTING & PROPOSED A-2.1 ELEVATION - EAST, ROOF FRAMING PLAN, ROOF PLAN A-3.1 BUILDING SECTION, MILLWORK DETAILS, BATHROOM ELEVATION A-4.1 WALL TYPES, EAVE DETAIL, CMU WALL DETAIL A-5.1 REFLECTED CEILING PLAN, ELECTRIC & SWITCHING PLAN, HVAC PLAN, LIGHTING SCHEDULE A-6.1 SCHEDULES TITLE SHEET - PROJECT SUMMARY & SUST. SUMMARY VCM-1 VCM-2 VCM-3 TAPE GYP. TO VCM-2 5/8" GYPSUM BOARD, TAPED/SEALED. LIQUID-APPLIED, OVER CMU WALL, AIR-BARRIER MEMBRANE CONCRETE SLAB VCM-2 LIQUID-APPLIED AIR BARRIER A0.0 1VAPOR-CONTROL MEMBRANE BUILDING DIAGRAM SCALE: 1/4" = 1'-0" PROJECT SUSTAINABILITY NARRATIVE: TAPE VCM-2 TO WINDOW. TAPE GYP. TO VCM-2. TAPE VCM-2 TO DOOR. T H E S A L T Y P A W 6 0 3 D A R T M O U T H S T . D A R T M O U T H , M A 0 2 7 4 7 SYMBOL DESCRIPTION 2 A 0.0 PROSOCO R-GUARD SPRAY/BRUSH WRAP MVP, AIR AND WATER BARRIER ON INSIDE-FACE OF EXISTING CMU WALL SCEDULE: VAPOR-CONTROL MEMBRANES NO SCALE VCM-2 LIQUID-APPLIED AIR BARRIER, ALL AREAS COVERED. VCM-1 5/8" GYPSUM BOARD, ALL SEAMS TAPED/SELAED & PERIMETER CAULKED. VCM-3 CONCRETE SLAB - REPAIRED & SEALED. MEMBRANE CONTINUITY: - TAPE - CAULK "MEMBRANE" AT CEILING, TAPE ALL SEAMS AND CAULK AT EDGES. GYP. WHERE EXPOSED IN 101 LOBBY TO BE PLASTERED AND PAINTED. PRO CLIMA TAPES & CAULKS: - TESCON VANA ALL PURPOSE TAPES - CONTEGA HF CAULK PROSOCO "GEMSTONE" STAIN AND "CONCRETE PROTECTOR SB", 6 COATS, TYPICAL ALL FLOORS VAPOR-CONTROL MEMBRANE SCHEDULE TAPE WINDOW TO VCM-2. CAULK OR TAPE VCM-2 TO VCM-3 BUILDING: ADAPTIVE RE-USE STRATEGY IS TO KEEP AS MUCH OF THE EXISTING BUILDING AS POSSIBLE: EXISTING BUILDING TO REMAIN. ALL RENOVATIONS OCCUR WITHIN THE EXISTING FOOTPRINT. EXISTING CMU WALLS AT EXTERIOR TO REMAIN. EXISTING CONCRETE SLAB TO REMAIN. WALLS: CMU WALLS TO RECEIVED A LIQUID APPLIED AIR-BARRIER AT INTERIOR PRIOR TO CONTINUOUS INTERIOR RIGID INSULATION. THE COMBINATION OF AIR-SEALING AND INSULATION WILL IMPROVE INSULATION, REDUCE HEAT LOSS, AND REDUCE HUMIDITY. ROOF: THE EXISTING SERIES OF BUILT-UP ROOFS HAS FAILED AND IS REPLACED WITH A SINGLE-SPAN SCISSOR TRUSS SYSTEM. THE TRUSS PROVIDES A GIANT VOID FOR PREMIUM INSULATION AT THE ROOF PLANE, A SLOPE FOR SOLAR PANEL INSTALLATION AND A ELEVATED CEILING HEIGHT AT THE INTERIOR FOR UTILITIES WITHIN A CONDITIONED SPACE. THE UNDERSIDE OF THE TRUSS BECOMES A CONTINUOUS AIR-BARRIER WITH THE INSTALLATION OF GYSPUM BOARD SYSTEM. FLOOR: THE EXISTING CONCRETE FLOOR WILL REMAIN. THE EXISTING DRAIN-LINE LOCATIONS WILL REMAIN AND ALL NEW EQUIPMENT TO TIE-INTO THESE EXISTING LOCATIONS TO EXTENT POSSIBLE. ANY MODIFICATIONS AS PER CODE REQUIREMENTS ARE TO BE PATCHED. THE FLOOR THROUGHOUT WILL BE A STAINED AND SEALED CONCRETE SYSTEM BY PROSOCO - THUS UTILIZING THE EXISTING CONDITIONS AND CREATING A HEALTHY, DURABLE AND AFFORDABLE FLOOR. THERMAL IMPROVEMENTS: THE INTERIOR SPACE WILL BECOME A CONTINUOUS AIR-BARRIER. THE ROOF INSULATION WILL BE INCREASED TO R-85. THE EXTERIOR WALL INSULATION WILL BE INCREASED TO R-17. THE ENTRANCE STOREFRONT WILL BE REPLACED WITH HI-PERFORMANCE INSULATING STOREFRONT SYSTEM WITH INSULATED WINDOWS AND AIR-SEAL JOINTS. HVAC: A NEW HI-EFFICIENCY HVAC SYSTEM WILL BE INSTALLED WITHIN THE CONDITIONED SPACE. PROPOSED EAST ELEVATION NOTE: MAINTAIN CONTINUATION OF AIR-BARRIER SYSTEM. A1.1 1PLAN - 1ST FLOOR - EXISTING & PROPOSED SCALE: 1/2" = 1'-0" NORTH A3.1 1 PERMIT SET - CONSTRUCTION DOCUMENTS DATE: 03.12.2019 THE SALTY PAW SPA & WOOF WASH - 603 DARTMOUTH ST. SOUTH DARTMOUTH, MA, 02747 kathryn duff ra cphc A 1.1 LOBBY 240 SF RECEPTION 95 SF GROOMING/ KENNEL 260 SF SELF-GROOMING 260 SF HP TLT 45 SF UTILITY 35 SF BREAK ROOM 85 SF EGRESS/COLLECTION 75 SF OFFICE/ LARGE WASH 260 SF EXISTING ELECTRICAL PANEL TO REMAIN 58" ELITE ADA BATHING TUB STATION (40 SF) PLAN KEY EXISTING WALLS PROPOSED WALLS - PART. HT. PROPOSED WALLS - FULL HT.32'-5"46'-11" 8'-112"7'-6"6'-4"12'-0"5'-3"5'-0"5'-0"5'-0"10'-6"27'-2"24'-812"10'-0" 40'-412" 4'-9"33'-1"5'-1012"50" ADJUSTABLEBATHING TUBSTACKABLE WASHER/ DRYER PROPOSED PATCH @ CMU FIRST FLOOR PLAN - EXISTING & PROPOSED 101 102 103 104 105 106 107 108 109 A A A B B D C D D P-2P-1 P-4 P-6 50" ADJUSTABLEBATHING TUBP-5 P-7 P-8 P-7 P-8 P-5 P-7 P-8 50" ADJUSTABLE BATHING TUB 50" ADJUSTABLE BATHING TUB P-3 P-5 P-7 P-8 P-5 P-7 P-8 D *D 24'-812"5'-212"6'-0"SOLID-SURFACE COUNTERTOP & 4" BACSKPLASH WITH PAINTED BASE & UPPER CABINETS 3'-0" 1'-8"3'-6" NEW REFRIGERATORS NEW RECEPTION DESK AND 3' HIGH SWIVEL DOOR NEW COUNTER AND DISPLAY SHELVING EXISTING CONCRETE FLOORS GRINDED AND NEW "GEMSTONE" PROSOCO STAIN AND "CONCRETE PROTECTOR SB", 6 COATS, TYPICAL ALL FLOORS32'-5"PARTIAL HEIGHT WALLS WITH WOOD CAP P-9 TYP.TYP.4'-1"THROUGH-WALL COLLECTION BINS AT UPPER WALL 1'-6"FULL-HEIGHT 3X6 TILE ACCENT WALL GENERAL NOTES: 1. ALL WORK, AS DEFINED OR IMPLIED WITHIN THESE CONSTRUCTION DRAWINGS AND BUILDING SPECIFICATIONS IS TO BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE, AND NATIONAL BUILDING CODES AND REGULATIONS. 2. ALL DIMENSIONS SHOWN REPRESENT APPROXIMATE DELINEATIONS AND ARE NOT INTENDED TO BE USED FOR CONSTRUCTION PURPOSES. ALL WIDTH DIMENSIONS ARE APPROXIMATE, AS WALLS ARE UNEVEN STONE AND/OR BRICK MASONRY. 3. THE CONTRACTOR SHALL EXAMINE THE ENTIRE SITE, AND WILL TAKE INTO ACCOUNT ALL CONDITIONS THEREON AS MAY AFFECT THE PERFORMANCE OF THE WORK UNDER THE CONTRACT. ALL DIMENSIONS MUST BE VERIFIED IN-FIELD PRIOR TO COMMENCING WORK. CONTRACTOR TO NOTIFY ARCHITECT OF ANY DISCREPANCIES AND/OR DEVIATIONS FROM WHAT IS PRESENTED AND/OR INDICATED ON THESE DRAWINGS AND SPECIFICATIONS. 4. THESE DRAWINGS ARE INTENDED TO SHOW THE EXISTING CONDITIONS OF THE EXISTING MAIN BUILDING LOCATED AT 603 DARTMOUTH ST, SOUTH DARTMOUTH, MA. ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN FIELD. DO NOT SCALE DRAWINGS. CONTRACTOR TO NOTIFY THE ARCHITECT AND THE OWNER IF ANY CONDITIONS APPEAR CONTRARY TO THE DRAWINGS AND/OR SPECIFICATIONS. 5. THE ARCHITECT AND THE ARCHITECT'S CONSULTANTS SHALL HAVE NO RESPONSIBILITY FOR THE IDENTIFICATION, DISCOVERY, PRESENCE, HANDLING, REMOVAL OR DISPOSAL OF, OR EXPOSURE OF PERSONS TO HAZARDOUS MATERIALS IN ANY FORM AT THE PROJECT SITE. 9'-4"4'-114"3'-0"30'-03 4" 3'-8"3'-6"30'-2" 42'-6"34'-9" C B A 2'-0" D D ALL SELF-GROOMING WALLS: NEW FRP PANEL FLOOR TO CEILING, SMOOTH, COLOR TBD. 1 A2.1 49'-6" U.C. REF (BY OWNER)2'-10"4'-8"4"1'-8"2'-712"3'-6"4'-6"3'-6"4'-6"3'-6"2'-712"2'-10"5'-412"13'-412"NEW FURNACE ON PLATFORM ABOVE CEILING, FASTENED TO TRUSS 2"11"812"4'-612"1'-6"1'-6"11'-312" WINDOW TO BE FROSTED/ETCHED GLASS2'-6"2'-912"3'-6"2'-912"A-1 A-2 A-3 A-4 1'-7"1'-6"A-5 (DOOR)A-6 CLEAR MIN.CLEAR MIN.1 2 2 E1FURRED-OUT SIM. +/- V.I.F. +/- V.I.F. +/- V.I.F. +/- V.I.F.+/- V.I.F.+/- V.I.F.+/- V.I.F.+/- V.I.F.+/- V.I.F. +/- V.I.F.+/- V.I.F.1 2 A3.1 A3.1 3 A3.1 3 A3.1 4 BASE CABINET ONLY NEW SOLID SURFACE, 30" DEEP COUNTER & BACKSPLASH OVER 34" PLYWOOD AND PLYWOOD SUPPORTS W/TRIM @ 4'-0" O.C. PAINTED. SEE 1/A3.1 PERMIT SET - CONSTRUCTION DOCUMENTS DATE: 03.12.2019 THE SALTY PAW SPA & WOOF WASH - 603 DARTMOUTH ST. SOUTH DARTMOUTH, MA, 02747 kathryn duff ra cphc A 2.1 EAST EXTERIOR ELEVATION, ROOF PLAN, ROOF FRAMING PLAN A2.1 1ELEVATION -EAST - EXISTING & PROPOSED SCALE: 1/2" = 1'-0" GENERAL NOTES: 1. ALL WORK, AS DEFINED OR IMPLIED WITHIN THESE CONSTRUCTION DRAWINGS AND BUILDING SPECIFICATIONS IS TO BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE, AND NATIONAL BUILDING CODES AND REGULATIONS. 2. ALL DIMENSIONS SHOWN REPRESENT APPROXIMATE DELINEATIONS AND ARE NOT INTENDED TO BE USED FOR CONSTRUCTION PURPOSES. ALL WIDTH DIMENSIONS ARE APPROXIMATE, AS WALLS ARE UNEVEN STONE AND/OR BRICK MASONRY. 3. THE CONTRACTOR SHALL EXAMINE THE ENTIRE SITE, AND WILL TAKE INTO ACCOUNT ALL CONDITIONS THEREON AS MAY AFFECT THE PERFORMANCE OF THE WORK UNDER THE CONTRACT. ALL DIMENSIONS MUST BE VERIFIED IN-FIELD PRIOR TO COMMENCING WORK. CONTRACTOR TO NOTIFY ARCHITECT OF ANY DISCREPANCIES AND/OR DEVIATIONS FROM WHAT IS PRESENTED AND/OR INDICATED ON THESE DRAWINGS AND SPECIFICATIONS. 4. THESE DRAWINGS ARE INTENDED TO SHOW THE EXISTING CONDITIONS OF THE EXISTING MAIN BUILDING LOCATED AT 603 DARTMOUTH ST, SOUTH DARTMOUTH, MA. ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN FIELD. DO NOT SCALE DRAWINGS. CONTRACTOR TO NOTIFY THE ARCHITECT AND THE OWNER IF ANY CONDITIONS APPEAR CONTRARY TO THE DRAWINGS AND/OR SPECIFICATIONS. 5. THE ARCHITECT AND THE ARCHITECT'S CONSULTANTS SHALL HAVE NO RESPONSIBILITY FOR THE IDENTIFICATION, DISCOVERY, PRESENCE, HANDLING, REMOVAL OR DISPOSAL OF, OR EXPOSURE OF PERSONS TO HAZARDOUS MATERIALS IN ANY FORM AT THE PROJECT SITE. A2.1 3PLAN - ROOF FRAMING - PROPOSED SCALE: 3/16" = 1'-0" F.O. CMU F.O. SILL F.O. CMU F.O. CMUF.O. CMU F.O. CMU F.O. SILL F.O. CMU 2 x _ WOOD SCISSOR TRUSSES @ 2'-0" O.C., AS REQUIRED. A2.1 2PLAN - ROOF PLAN - PROPOSED SCALE: 3/16" = 1'-0" NORTH NORTH SOLAR PANEL SYSTEM RIDGE VENT, AS REQUIRED NEW GUTTERS AT EAVES, COORDINATE DOWNSPOUTS WITH SITE REQUIREMENTS 12:7SLOPENEW ASPHALT SHINGLES 12:7SLOPENEW BOARD-AND-BATTEN PATTERNED BORAL FASCIA AT NEW ROOF TRUSS, WITH RAKE BOARD AND TRIM BOARD, PTD. COLORS TO BE SELECTED BY ARCHITECT AND OWNER. 34'-9"9'-0"T.O. CMU 20'-10"ROOF RIDGE STOREFRONT BY OTHERS TYPICAL AT MASONRY: EXISTING BRICKWORK & CMU TO BE PATCHED AND REPARIED AS REQUIRED. PAINT, COLOR TO BE SELECTED BY ARCHITECT. NEW BORAL 6' V-GROVE PANELS, PAINTED. COLOR TO BE SELECTED BY ARCHITECT AND OWNER. NEW SIGNAGE ON V-GROVE BORAL BOARDS, COORDINATE WITH OWNER 6'-0"7'-112"7'-6"42'-6"35'-6" +/-34'-9"34'-7"49'-6" BUILDING LINE BELOW A3.1 1BUILDING SECTION - TOWARD WEST SCALE: 1/2" = 1'-0" PERMIT SET - CONSTRUCTION DOCUMENTS DATE: 03.12.2019 THE SALTY PAW SPA & WOOF WASH - 603 DARTMOUTH ST. SOUTH DARTMOUTH, MA, 02747 kathryn duff ra cphc A 3.1 PLAN KEY EXISTING WALLS PROPOSED WALLS - PART. HT. PROPOSED WALLS - FULL HT. PROPOSED PATCH @ CMU BUILDING SECTION GENERAL NOTES: 1. ALL WORK, AS DEFINED OR IMPLIED WITHIN THESE CONSTRUCTION DRAWINGS AND BUILDING SPECIFICATIONS IS TO BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE, AND NATIONAL BUILDING CODES AND REGULATIONS. 2. ALL DIMENSIONS SHOWN REPRESENT APPROXIMATE DELINEATIONS AND ARE NOT INTENDED TO BE USED FOR CONSTRUCTION PURPOSES. ALL WIDTH DIMENSIONS ARE APPROXIMATE, AS WALLS ARE UNEVEN STONE AND/OR BRICK MASONRY. 3. THE CONTRACTOR SHALL EXAMINE THE ENTIRE SITE, AND WILL TAKE INTO ACCOUNT ALL CONDITIONS THEREON AS MAY AFFECT THE PERFORMANCE OF THE WORK UNDER THE CONTRACT. ALL DIMENSIONS MUST BE VERIFIED IN-FIELD PRIOR TO COMMENCING WORK. CONTRACTOR TO NOTIFY ARCHITECT OF ANY DISCREPANCIES AND/OR DEVIATIONS FROM WHAT IS PRESENTED AND/OR INDICATED ON THESE DRAWINGS AND SPECIFICATIONS. 4. THESE DRAWINGS ARE INTENDED TO SHOW THE EXISTING CONDITIONS OF THE EXISTING MAIN BUILDING LOCATED AT 603 DARTMOUTH ST, SOUTH DARTMOUTH, MA. ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN FIELD. DO NOT SCALE DRAWINGS. CONTRACTOR TO NOTIFY THE ARCHITECT AND THE OWNER IF ANY CONDITIONS APPEAR CONTRARY TO THE DRAWINGS AND/OR SPECIFICATIONS. 5. THE ARCHITECT AND THE ARCHITECT'S CONSULTANTS SHALL HAVE NO RESPONSIBILITY FOR THE IDENTIFICATION, DISCOVERY, PRESENCE, HANDLING, REMOVAL OR DISPOSAL OF, OR EXPOSURE OF PERSONS TO HAZARDOUS MATERIALS IN ANY FORM AT THE PROJECT SITE. ROOF SYSTEM: PRE-MANUFACTURERED TRUSS WITH LOOSE-FILL INSULATION AND VENT BAFFLES BETWEEN TRUSSES, RIDGE VENT, AND SOFFIT VENTS. EXTERIOR WALL SYSTEM: -EXISTING CMU WALLS SOLID-FILLED WITH CONCRETE FILL IN CERTAIN BAYS (SEE DIAGRAM 3/A4.1) TO CONTINUE STRUCTURAL LOAD TO FOUNDATION. -WALLS TO BE VAPOR-CONTROLLED AND INSULATED ON INTERIOR (SEE DIAGRAM 1/A0.0 AND EXTERIOR WALL TYPE EX-1 ON 1/A4.1) -EXTERIOR OF EXISTING CMU TO BE PAINTED. GROOMING/ KENNELSELF-GROOMINGBREAK ROOM 103 104108 INTERIOR PARTITION SYSTEM: -INTERIOR WALLS TO EXTEND TO UNDERSIDE OF GYP. CEILING (ABOVE DROP CEILING) AND FILLED WITH SOUND-BATT INSULATION TO PREVENT THE TRANSMISSION OF NOISE THROUGHOUT. SOLAR ARRAY SYSTEM: CONTRACTOR TO COORDINATE WITH OWNER FOR OWNER-SUPPLIED SOLAR ARRAY SYSTEM COMPONENTS AND LOCATION. FLOOR SYSTEM: -EXISTING SLAB-ON-GRADE TO BE GRINDED AND RECEIVE NEW TREATMENT, (SEE 2/A0.0 FOR SPEC). PATCH CONCRETE WHERE NEW PLUMBING TYING INTO EXISTING. A4.1 2 HVAC SYSTEM: NEW FURNACE ON PLATFORM MOUNTED TO TRUSSES, ABOVE DROP-CEILING IN CONDITIONED SPACE. VENTING TO EXTERIOR THROUGH WEST WOOD WALL ABOVE CMU WALL. 34'-9"9'-0"7 12 12 4 T.O. CMU T.O. SLAB14'-8"CLG.20'-10"ROOF RIDGE 8'-6"A.C.T. CEILING 3'-6"3'-6"7'-0"3'-10"3'-6"WDW SILL MASONRY OPENING, V.I.F.WDW FRAME GENERAL MILLWORK NOTES: 1. REFER TO BUILDING SPECIFICATIONS FOR ADDITIONAL SPECIFICAITONS AND REQUIREMENTS. 2. ALL MILLWORK CABINETS TO BE CONSTRUCTED WITH 1/2" BIRCH-VENEER PLYWOOD BOXES WITH POLY FINISH ON INTERIOR SURFACES, WITH SOLID WOOD OVERLAY STYLE & RAIL DOORS AND DRAWER FRONTS WITH FLAT PANELS OF MDF AND/OR PLYWOOD. 3. ALL MILLWORK TO BE FACTORY FINISHED WITH AN OPAQUE LOW/NO-VOC FINISH AS APPROVED BY ARCHITECT. COLOR APPROVED BY ARCHITECT. 4. ALL MILLWORK DOORS TO HAVE FLAT PANELS WITH SQUARE STICKING WITH OVOLO PROFILE - APPROVED BY ARCHITECT. 5. ALL MILLWORK COUNTERS, UNLESS OTHERWISE NOTED, TO BE SOLID SURFACE COUNTERTOPS OVER 3 4" PLYWOOD SUBSTRATE, TYP. NOTE: USE P.T. PLYWOOD AT SINK INSTALLATION SURFACES. 6. UPPER KITCHEN CABINETS TO MATCH BASE CABINETS IN BOXES. 6. CONTRACTOR TO SUBMIT SHOP DRAWING FOR APPROVAL FOR ALL MANUFACTURED LUMBER PRODUCTS. 7. ALL HARDWARE TO BE APPROVED BY ARCHITECT. NEW 4" TALL INTEGRATD SOLID SURFACE BACKSPLASHAND COUNTERTOP, TYP.3'-0"2'-1"1'-6"3'-314" V.I.F.1'-0" DRAWER, MATCH CABINETRY 712"2'-0"3"112" CABINET DOUBLE DOORS A3.1 3KITCHENETTE MILLWORK SCALE: 1 1/2" = 1'-0" A3.1 2BATHROOM ELEVATION SCALE: 1/2" = 1'-0" A3.1 4KITCHENETTE MILLWORK SCALE: 1 1/2" = 1'-0" UNDERCOUNTER RAXX BRACKET, ROUNDED CORNERS, AS REQ'D. WOOD STUD WALL SUPPORT, DOUBLE TOP PLATE, STUDS @ 16" O.C. WITH 1/2" PAINTED GYP. AT INTERIOR SURFACE PROVIDE WIRE CHASE IN KNEEWALL UNDER-MOUNTED KEYBOARD TRAY ON SLIDES 2'-0"3'-0" V.I.F.1'-4"314" FULL-HEIGHT 3X6 TILE ACCENT WALL W/TILE BASE GYP & RUBBER BASE AT ALL OTHER WALLS8'-6"3'-6"1'-6"1'-6"3'-11" PARTIAL-HEIGHT 2X4 STUD WALLS WITH P-LAM SURFACE AND WOOD CAP.3'-0" NORTH PERMIT SET - CONSTRUCTION DOCUMENTS DATE: 03.12.2019 THE SALTY PAW SPA & WOOF WASH - 603 DARTMOUTH ST. SOUTH DARTMOUTH, MA, 02747 kathryn duff ra cphc A 4.1 PLAN KEY EXISTING WALLS PROPOSED WALLS - PART. HT. PROPOSED WALLS - FULL HT. PROPOSED PATCH @ CMU A4.1 1SECTION - DETAILS - WALL TYPES SCALE: 1 1/2" = 1'-0" WALL TYPE 2 2X6 WD STUD PLUMBING WALL,TYP.2WALL TYPE 1 - TYPICAL, U.O.N. 2X4 WD STUD WALL, TYP.1 EXTERIOR WALL TYPE 1 EXTERIOR 10" CMU WALL W/ RIGID INSULATION AND SERVICE CHANNEL E1 A4.1 2SECTION - DETAILS - ROOF EAVE SCALE: 3" = 1'-0" 7 12 12 4 GRACE "ICE & WATER" BARRIER OVER PLYWOOD SHEATHING, UP 3' FROM EAVE AND GABLE ROOF EDGE, TYP. ROOFING PAPER, OVER 5/8" PLYWOOD SHEATHING, TYP. 1 1/2" ROOF VENT BAFFLE, FASTEND TO UNDERSIDE OF PLYWOOD SHEATHING, AS REQUIRED. 1" INSULATED SHEATHING PANEL NOTCHED AROUND NEW ROOF TRUSS SYSTEM, AS REQUIRED. SEAL ALL SEAMS WITH SPRAY FOAM INSULATION ALUMINUM FLASHING UNDER GRACE "ICE & WATER" FASTENED OVER PLYWOOD SHEATHING. BORAL TRIM BOARDS, PTD COLOR TO BE SELECTED BY OWNER. J BOLT SET IN GROUT @ SOLID FILL BLOCKS @ 4'-0" O.C SIMPSON HURRICANE CLIPS, AS PER ENGINEER SPECIFICATION CONTINUOUS SOFFIT VENT, AS REQUIRED. COLOR TO MATCH BORAL TRIM. 5/8" MOISTURE RESISTANT GYP BOARD OVER 1X3 WD FURRING FASTEND TO ROOF TRUSS. TAPE ALL SEAMS AND CAULK @ PERIMETER ACT DROP CEILING HUNG FROM ROOF TRUSS SYSTEM. ALUMINUM GUTTER FASTENED OVER BORAL TRIM BOARD. CONTINUOUS TESCON VANA AIR SEAL TAPE @ PERMITER. TAPE 5/8" MOISTURE RESISTANT GYP BOARD TO LIQUID APPLIED AIR BARRIER. CONTINUOUS CAULKING AT ALL SEAMS, AS REQUIRED. ROOF TRUSS SYSTEM PER ENGINEER SPECIFICATIONS, FILLED WITH LOOSE FILL INSULATION, AS REQUIRED. 1 1/2" SERVICE CHANNEL, FILLED WITH ROCKWOOL BATT INSULATION. 2" XPS RIGID INSULATION, TAPE ALL SEAMS WITH AIR SEAL TAPE AS REQUIRED. EXISTING CMU WALL W/ PROSOCO LIQUID APPLIED AIR BARRIER, AS REQUIRED. 1X3 PT WD SERVICE CHANNEL STUD @ CONCRETE FLOOR INTERSECTION, TYP. 4" RUBBER COVE BASE APPLIED OVER GYP BOARD, AS REQUIRED. EXISTING CONCRETE FLOOR 5/8" MOISTURE RESISTANT GYP BOARD W/ PLASTER SKIM & PTD, HELD UP 1/4" FROM FINISH FLOOR, TYP. (BOTH SIDES) 4" RUBBER COVE BASE APPLIED OVER GYP BOARD OR FRP PANEL, AS REQUIRED. TYP. 5/8" MOISTURE RESISTANT GYP BOARD W/ PLASTER SKIM & PTD, HELD UP 1/4" FROM FINISH FLOOR, TYP. 4" RUBBER COVE BASE APPLIED OVER GYP BOARD, AS REQUIRED. TYP. 2X4 PT WD BOTTOM PLATE, FASTENED TO CONCRETE AS REQUIRED. 5/8" MOISTURE RESISTANT GYP BOARD W/ PLASTER SKIM & PTD, HELD UP 1/4" FROM FINISH FLOOR, TYP. 2X4 WD STUD WALL @ 16" O.C. FILLED WITH ROCKWOOL BATT INSULATION. EXISTING CONCRETE FLOOR EXISTING CONCRETE FLOOR 1'-2 18" 10"2"112"5/8" 6 3 4" 5/8"5/8"5 12" 4 3 4" 5/8"3 12"5/8" (2) #5 BARS @ 4'-0" O.C. @ FILLED CMU WALL VOID, TYP. (2) #5 BARS @ 4'-0" O.C. @ FILLED CMU WALL VOID, TYP. (2) 2X8 PT WD SILL OVER CONTINUOUS SILL SEALER ANCHORED W/ LARGE WASHER AND NUT, AS REQUIRED. A4.1 3ELEVATION - DETAIL TYPICAL - J-BOLT & CMU WALL VOID FILL SCALE: 1" = 1'-0" 4'-0" TYP LC LC J BOLT SET IN GROUT @ SOLID FILL BLOCKS @ 4'-0" O.C (2) 2X8 PT WD SILL OVER CONTINUOUS SILL SEALER ANCHORED W/ LARGE WASHER AND NUT, AS REQUIRED. SOLID FILL CMU VOID W/ GROUT @ 4'-0" O.C. W/ (2) #5 BARS FULL LENGTH, TYP. CMU DETAIL WALL TYPES & EAVE DETAIL 1'-0" 1"3"COVER3/4" FRP PANEL @ 104 SELF GROOMING: FRP WALL PANEL OVER 5/8" MOISTURE RESISTANT GYP, UP TO ACT DROP CEILING AND HELD UP 1/4" OFF FACE OF FINISH FLOOR W/ 4" RUBBER COVE BASE. ACT DROP CEILING WHERE OCCURS, TYP. GENERAL NOTES: 1. ALL WORK, AS DEFINED OR IMPLIED WITHIN THESE CONSTRUCTION DRAWINGS AND BUILDING SPECIFICATIONS IS TO BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE, AND NATIONAL BUILDING CODES AND REGULATIONS. 2. ALL DIMENSIONS SHOWN REPRESENT APPROXIMATE DELINEATIONS AND ARE NOT INTENDED TO BE USED FOR CONSTRUCTION PURPOSES. ALL WIDTH DIMENSIONS ARE APPROXIMATE, AS WALLS ARE UNEVEN STONE AND/OR BRICK MASONRY. 3. THE CONTRACTOR SHALL EXAMINE THE ENTIRE SITE, AND WILL TAKE INTO ACCOUNT ALL CONDITIONS THEREON AS MAY AFFECT THE PERFORMANCE OF THE WORK UNDER THE CONTRACT. ALL DIMENSIONS MUST BE VERIFIED IN-FIELD PRIOR TO COMMENCING WORK. CONTRACTOR TO NOTIFY ARCHITECT OF ANY DISCREPANCIES AND/OR DEVIATIONS FROM WHAT IS PRESENTED AND/OR INDICATED ON THESE DRAWINGS AND SPECIFICATIONS. 4. THESE DRAWINGS ARE INTENDED TO SHOW THE EXISTING CONDITIONS OF THE EXISTING MAIN BUILDING LOCATED AT 603 DARTMOUTH ST, SOUTH DARTMOUTH, MA. ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN FIELD. DO NOT SCALE DRAWINGS. CONTRACTOR TO NOTIFY THE ARCHITECT AND THE OWNER IF ANY CONDITIONS APPEAR CONTRARY TO THE DRAWINGS AND/OR SPECIFICATIONS. 5. THE ARCHITECT AND THE ARCHITECT'S CONSULTANTS SHALL HAVE NO RESPONSIBILITY FOR THE IDENTIFICATION, DISCOVERY, PRESENCE, HANDLING, REMOVAL OR DISPOSAL OF, OR EXPOSURE OF PERSONS TO HAZARDOUS MATERIALS IN ANY FORM AT THE PROJECT SITE. 1'-2 1/8" GYP CEILING 2X6 PT WD BOTTOM PLATE, FASTENED TO CONCRETE AS REQUIRED. 2X6 WD STUD WALL @ 16" O.C. FILLED WITH ROCKWOOL BATT INSULATION. NOTE: SEE VAPOR CONTROL MEMBRANE DIAGRAM ON 1/A0.0 PERMIT SET - CONSTRUCTION DOCUMENTS DATE: 03.12.2019 THE SALTY PAW SPA & WOOF WASH - 603 DARTMOUTH ST. SOUTH DARTMOUTH, MA, 02747 kathryn duff ra cphc A 5.1 PLAN KEY EXISTING WALLS PROPOSED WALLS - PART. HT. PROPOSED WALLS - FULL HT. PROPOSED PATCH @ CMU REFLECTED CEILING PLAN AND ELECTRICAL & SWITCHING PLAN A5.1 1REFLECTED CEILING PLAN - EXISTING & PROPOSED SCALE: 1/4" = 1'-0" GENERAL NOTES: 1. ALL WORK, AS DEFINED OR IMPLIED WITHIN THESE CONSTRUCTION DRAWINGS AND BUILDING SPECIFICATIONS IS TO BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE, AND NATIONAL BUILDING CODES AND REGULATIONS. 2. ALL DIMENSIONS SHOWN REPRESENT APPROXIMATE DELINEATIONS AND ARE NOT INTENDED TO BE USED FOR CONSTRUCTION PURPOSES. ALL WIDTH DIMENSIONS ARE APPROXIMATE, AS WALLS ARE UNEVEN STONE AND/OR BRICK MASONRY. 3. THE CONTRACTOR SHALL EXAMINE THE ENTIRE SITE, AND WILL TAKE INTO ACCOUNT ALL CONDITIONS THEREON AS MAY AFFECT THE PERFORMANCE OF THE WORK UNDER THE CONTRACT. ALL DIMENSIONS MUST BE VERIFIED IN-FIELD PRIOR TO COMMENCING WORK. CONTRACTOR TO NOTIFY ARCHITECT OF ANY DISCREPANCIES AND/OR DEVIATIONS FROM WHAT IS PRESENTED AND/OR INDICATED ON THESE DRAWINGS AND SPECIFICATIONS. 4. THESE DRAWINGS ARE INTENDED TO SHOW THE EXISTING CONDITIONS OF THE EXISTING MAIN BUILDING LOCATED AT 603 DARTMOUTH ST, SOUTH DARTMOUTH, MA. ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN FIELD. DO NOT SCALE DRAWINGS. CONTRACTOR TO NOTIFY THE ARCHITECT AND THE OWNER IF ANY CONDITIONS APPEAR CONTRARY TO THE DRAWINGS AND/OR SPECIFICATIONS. 5. THE ARCHITECT AND THE ARCHITECT'S CONSULTANTS SHALL HAVE NO RESPONSIBILITY FOR THE IDENTIFICATION, DISCOVERY, PRESENCE, HANDLING, REMOVAL OR DISPOSAL OF, OR EXPOSURE OF PERSONS TO HAZARDOUS MATERIALS IN ANY FORM AT THE PROJECT SITE. A5.1 3ELECTRICAL AND SWITCHING PLAN - PROPOSED SCALE: 1/4" = 1'-0" A5.1 2PLAN - HVAC LAYOUT - PROPOSED SCALE: 3/16" = 1'-0" F-2F-2F-2 F-2F-2F-2F-2 F-2 F-2 F-2 F-2 F-2 F-2 F-2 F-1 F-1 F-1 F-1 F-4 F-4 F-4 F-4 F-3 F-2F-2F-2F-2 F-2F-2F-2F-2 F-2 F-2 F-2 F-2 F-2 F-2 F-2 F-1 F-1 F-1 F-1 F-4 F-4 F-4 F-4 F-3 F-2 14'-8" GYP. (AT PEAK) NEW 2X2 ACT CEILING: ARMSTRONG "DUNE TEGULAR" W/ 916" SUPRAFINE GRID NEW CLG. 58" GYPSUM BOARD, PTD. F-2 9'-3" GYP. (AT WALL) 9'-3" GYP. (AT WALL) 8'-6" A.C.T. (TYP.) S S3S3S3 S3 S3 S3 S3 S3 S3 S3 S3 S 7'-6" GYP. SOFFIT NEW FURNACE LOCATION ABOVE ACT CEILING, PLATFORM MOUNTED TO TRUSS SWITCH & OUTLET SCHEDULE NO SCALE TYPE DESCRIPTION MOUNT S S3 SINGLE POLE SWITCH 42" A.F.F. THREE-WAY SWITCH 42" A.F.F. DUPLEX POWER OUTLET 20 AMP, 125 VOLT (U.O.N.), VERIFY ELECTRIC SERVICE 18" A.F.F. DUPLEX POWER OUTLET 20 AMP, 125 VOLT-U-SLOT GROUND, VERIFY ELECTRIC SERVICE 6" ABOVE COUNTER DUPLEX POWER OUTLET 20 AMP, 125 VOLT, GFCI 6" ABOVE COUNTER DUPLEX POWER OUTLET 20 AMP, 125 VOLT, GFCI 18" A.F.F. T CAT-6e DUPLEX VOICE/DATA OUTLET - (2) CAT-6e JACKS/OUTLET TO BE USED FOR PHONE AND/OR COMPUTER - ALL 4-PAIR COMPLETE/JACK. CAT-6e DUPLEX VOICE/DATA OUTLET - (2) CAT-6e JACKS/OUTLET TO BE USED FOR PHONE AND/OR COMPUTER - ALL 4-PAIR COMPLETE/JACK. THERMOSTAT AS REQ'D, CONFIRM LAYOUT W/ARCHITECT & OWNER. 18" A.F.F. 6" ABOVE COUNTER WALL SURFACE VOICE/DATA PATCH PANEL & SERVER & PHONE SERVICE WALL SURFACE POWER PANEL WALL SURFACE 5 A 5.1 4 A 5.1 EXITEXIT F-5 F-5 F-5 NEW FURNACE LOCATION ABOVE ACT CEILING, PLATFORM MOUNTED TO TRUSS CENTER FIXTURES ON WINDOWS, TYP.SLOPESLOPESYMBOL QT.DESCRIPTION SPECIFICATION NOTES F-1 F-3 PANASONIC WHISPER DC FAN/LIGHT FV-0511VQL1 F-4 F-2 COORDINATE VENTING 4 8' PENDANT STRIP LIGHT STARTEK STARPOWER SP-N1-8S-30K-CA-XX-PMGC05-NS-ND-U-PN 16 2'X2' GENERAL RECESSED LED LIGHT PANEL METALUX 22FP LED 22FP4235C LOCATED IN ACT DROP CEILING SEE RCP PLANS VENTALATION FAN/LIGHT1 4 LIGHTING SCHEDULE NO SCALE 5" HALO EXTERIOR RECESSED DOWN LIGHT W/ LENS 2700K COLOR TEMP.AS REQUIRED F-5 SURFACE MOUNTED, WALL, LED EMERGENCY EXIT LIGHT EMERGI-LITE EL-2 MRS SERIES (ESCORT II)3 F-6 SURFACE MOUNTED, WALL SCONCE, AT PEAK OF CEILING CERAMIC WALL SCONCE, PAINTED WALL COLOR. FIXTURE TBD, BY ARCHITECT2 F-6 F-6F-6F-6 F-5 F-5 F-5 S3 VENT TO WEST ABOVE CMU WALL, MEET CODE REQUIREMENTS WALL-MOUNTED RETURN (664 CFM) WALL-MOUNTED SUPPLY (332 CFM) WALL-MOUNTED SUPPLY (332 CFM) WALL-MOUNTED SUPPLY (332 CFM) F-1 LIGHTS MOUNTED AT 8'-0" A.F.F. PERMIT SET - CONSTRUCTION DOCUMENTS DATE: 03.12.2019 THE SALTY PAW SPA & WOOF WASH - 603 DARTMOUTH ST. SOUTH DARTMOUTH, MA, 02747 kathryn duff ra cphc A 6.1 PLAN KEY EXISTING WALLS PROPOSED WALLS - PART. HT. PROPOSED WALLS - FULL HT. PROPOSED PATCH @ CMU GENERAL NOTES: 1. ALL WORK, AS DEFINED OR IMPLIED WITHIN THESE CONSTRUCTION DRAWINGS AND BUILDING SPECIFICATIONS IS TO BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE, AND NATIONAL BUILDING CODES AND REGULATIONS. 2. ALL DIMENSIONS SHOWN REPRESENT APPROXIMATE DELINEATIONS AND ARE NOT INTENDED TO BE USED FOR CONSTRUCTION PURPOSES. ALL WIDTH DIMENSIONS ARE APPROXIMATE, AS WALLS ARE UNEVEN STONE AND/OR BRICK MASONRY. 3. THE CONTRACTOR SHALL EXAMINE THE ENTIRE SITE, AND WILL TAKE INTO ACCOUNT ALL CONDITIONS THEREON AS MAY AFFECT THE PERFORMANCE OF THE WORK UNDER THE CONTRACT. ALL DIMENSIONS MUST BE VERIFIED IN-FIELD PRIOR TO COMMENCING WORK. CONTRACTOR TO NOTIFY ARCHITECT OF ANY DISCREPANCIES AND/OR DEVIATIONS FROM WHAT IS PRESENTED AND/OR INDICATED ON THESE DRAWINGS AND SPECIFICATIONS. 4. THESE DRAWINGS ARE INTENDED TO SHOW THE EXISTING CONDITIONS OF THE EXISTING MAIN BUILDING LOCATED AT 603 DARTMOUTH ST, SOUTH DARTMOUTH, MA. ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN FIELD. DO NOT SCALE DRAWINGS. CONTRACTOR TO NOTIFY THE ARCHITECT AND THE OWNER IF ANY CONDITIONS APPEAR CONTRARY TO THE DRAWINGS AND/OR SPECIFICATIONS. 5. THE ARCHITECT AND THE ARCHITECT'S CONSULTANTS SHALL HAVE NO RESPONSIBILITY FOR THE IDENTIFICATION, DISCOVERY, PRESENCE, HANDLING, REMOVAL OR DISPOSAL OF, OR EXPOSURE OF PERSONS TO HAZARDOUS MATERIALS IN ANY FORM AT THE PROJECT SITE. HEATING EQUIPMENT SCHEDULE NO SCALE GENERAL HVAC NOTES: 1. REFER TO DRAWINGS FOR LOCATIONS OF HVAC EQUIPMENT. 2. CONTRACTOR TO SUBMIT LAYOUT OF NECESSARY PIPING & DUCTING & SYSTEM COMPONENTS NECESSARY FOR A COMPLETE AND BALANCED SYSTEM TO ARCHITECT FOR APPROVAL PRIOR TO COMMENCING WORK. 3. CONTRACTOR TO SUBMIT FULL SET OF HVAC EQUIPMENT SPECIFICATIONS FOR APPROVAL PRIOR TO ORDERING. 4. ALL WIRING TO BE DETERMINED BY CONTRACTOR, APPROVED BY ARCHITECT, PRIOR TO COMMENCING WORK. 5. CONTRACTOR TO PROVIDE SMOKE/CO DETECTORS AS REQUIRED BY CODE. TOILET ACCESSORIES SCHEDULE NO SCALE PLUMBING SCHEDULE NO SCALE 1 A 6.1 GENERAL PLUMBING NOTES: 1. REFER TO DRAWINGS FOR LOCATIONS OF PLUMBING FIXTURES AND ACCESSORY LOCATIONS. 2. REFER TO BUILDING SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 3. CONTRACTOR TO SUBMIT LAYOUT OF ALL PLUMBING PIPING, INCLUDING VENTS, SUPPLIES, AND DRAWINGS, TO ARCHITECT FOR APPROVAL PRIOR TO COMMENCING ANY PLUMBING WORK. 4. CONTRACTOR TO SUMBIT FULL SET OF PLUMBING FIXTURES FOR APPROVAL PRIOR TO ORDERING. 5. ALL PIPING CARRYING HEATED AND/OR COOLED WATER TO BE INSULATED. TOILET ACCESSORIES, TYP. SCALE: 1/4" = 1'-0" TOILET PAPER DISPENSER HP GRAB BARS MIRROR CLOTHES HOOK2'-0"0'-5" 1'-0" 3'-6"3'-0"3'-6" 0'-6" 1'-6"3'-4"3'-0"1'-3" 2'-0" CL 3'-6"VARIES 1'-2"5'-4"CL PAPER TOWEL DISP./ WASTE RECEPTACLE CL CL TOILET ACCESSORIES NOTE: BATHROOM TO HAVE (1) OF EACH ACCESSORY, UON, SEE NOTES.SYM.DESC.UNIT TYPE & NO.FINISH NOTES A-1 A-2 A-3 A-4 A-5 A-6 SYMBOL DESCRIPTION UNIT TYPE & NO.FINISH COLOR FITTING TYPE & NO.LOCATION NOTES P-1 TOILET TOTO ECO DRAKE CLOSED COUPLED TOILET - CST744EF.10 1.28 GPF. CERAMIC #01 COTTON TRIP LEVER TOILET ROOM ADA COMPLIANT IN REQUIRED ROOMS, 10" ROUGH-IN COORDINATE WITH TRADESMAN. P-2 SINK TOTO COMERCIAL WALL HUNG LAVATORY - LT307A-01 FAUCET: GROHE 2303600A - EUROSTYLE COSMOPOLITAN FAUCET, SOAP DISPENCER: BOBRICK COUNTER -MOUNTED TOP FILL SOAP DISPENCER - B-823 ADA COMPLIANT, WALL HUNG, COVER PIPING SEE ACCESSORIES. P-3 UTILITY SINK P-4 P-5 BOBRICK B-5806x42 - 1 14" DIA. S.S. GRAB BARS (2) GRAB BARS IN ADA REQUIRED BATHROOM. BOBRICK B-165 2436 - MIRROR WITH S.S. CHANNEL FRAME BOBRICK B-369 - RECESSED PAPER TOWEL AND WASTE RECEPTACLE SOLID SURFACE PANEL - W/ EXPOSED FASTENERS TOILET PAPER DISPENSER BOBRICK B-274 - DOUBLE ROLL T.P. DISPENSER VITREOUS CHINA ADA COMPLIANT IN REQUIRED BATHROOM. HP GRAB BARS MIRROR PAPER TOWEL DISPENSER DRAIN APRON SATIN FINISH S.S. SATIN FINISH COLOR TO BE SELECTED BY ARCHITECT P-6 P-7 P-9 FLOOR DRAIN ZURN INDUSTRIES - ROUND NICKEL BRONZE FLOOR DRAIN 29VN10, MODEL NUMBER GR-FR05NI- P2S-PS-CC NICKEL BRONZE POLISHED NICKEL BRONZE N/A CENTER ON ROOM COORDINATE WITH TRADES. CERAMIC #01 COTTON KITCHENETTE SINK P-8 HP DOG TUBS DOG TUBS SOAP DISPENSER VACUUM 0'-9"1'-3"CL 0'-8" 0'-6"2'-5"DRAIN APRON A-6 VARIES ADA COMPLIANT IN REQUIRED BATHROOM. ADA COMPLIANT IN REQUIRED BATHROOM. CLOTHES HOOK BOBRICK B-2116 - HEAVY DUTY CLOTHES HOOK WITH CONCEALED MOUNTING HARDEN STEEL ADA COMPLIANT IN REQUIRED BATHROOM. ADA COMPLIANT IN REQUIRED BATHROOM. A-5A-4A-3A-2A-1 ELKAY LUSTERTONE CLASSIC SINGLE BOWL DROP-IN ADA SINK - LRAD171665PD FIBERGLASS STAINLESS STEEL GROOMER'S BEST 58" ELITE BATHING TUB - GB58E-C STAINLESS STEEL FLYING PIG GROOMING 50" ELECTRIC GROOMING TUB - FP801 STAINLESS STEEL STAINLESS STEEL K9-III BLOWER/DRYER DOG DRYERS STEEL TBD TBDTBD N/A TOILET ROOM UTILITY ROOM BREAK ROOM SELF GROOMING SELF GROOMING OFFICE/ LARGE WASH SELF GROOMING SELF GROOMING ADA COMPLIANT IN REQUIRED ROOMS, ROUGH-IN COORDINATE WITH TRADESMAN. ROUGH-IN PLUMBING COORDINATE WITH TRADES. CENTER ON CABINET AS INDICATED.STAINLESS STEEL MUSTEE DURASTONE UTILATUB FLOOR STAND UTILITY TUB - 18F MARBLEIZED WHITE MUSTEE INTEGRATEDFAUCET: MODEL - 93.600, CHROME PLATED BRASS DUAL HANDLE SINK FAUCET W/ TOP REINFORCING BAR & PAIL HOOK ON SPOUT 2 A 6.1 3 A 6.1 4 A 6.1 QTY.UNIT TYPE & NO.DIMSSYSTEM LOCATION MOUNTINGSYSTEM GAS-FIRED FURNACE ABOVE CEILING IN OFFICE/ LARGE WASH (1) FIRST FLOOR MODEL R92PA1151524 RUUD GAS FIRED FURNACE, 115,000 BTU'S. A/C: (1) MODEL RCF6024 RUUD EVAPORATOR COIL, (1) MODEL RA1360 RUUD CONDENSING UNIT. R-6 REFLECTIX DUCT INSULATION. MOUNTED ABOVE ACT CEILING ON PLATFORM, HUNG FROM TRUSS SYSTEM. UNIT TO BE MOUNTED HORIZONTALLY 24 12" X 29 58" X 34" HONEYWELL MODEL # TH6320, WIFI THERMOSTAT WALLTHERMOSTAT(1)4" X 6" SCHEDULES - PLUMBING, HVAC, DOOR & WINDOW NOTES TBD BY OWNER SEE PLAN FOR SUPPLY & RETURN DUCTS & DIFFUSERS. VENTING TO OCCUR THROUGH WEST WALL ABOVE CMU. FAUCET: GROHE - EUROPLUS SINGLE-LEVER SINK FAUCET 32946002, SOAP DISPENCER: BOBRICK COUNTER -MOUNTED TOP FILL SOAP DISPENCER - B-823 OWNER TO SELECT COLOR OWNER TO COORDINATE WITH CONTRACTOROWNER TO COORDINATE WITH CONTRACTOR OWNER TO COORDINATE WITH CONTRACTOR OWNER TO COORDINATE WITH CONTRACTOR ROUGH-IN PLUMBING COORDINATE WITH TRADES. OWNER TO COORDINATE LOCATION AND INSTALATION WITH CONTRACTOR. BLOWER TO BE WALL MOUNTED IN WALL @ EACH SELF GROOMING STATION. DOOR SCHEDULE SCALE: 1/8" = 1'-0" 6 A 6.1 A B C D 3'-0"7'-0"WINDOW SCHEDULE SCALE: 1/8" = 1'-0" 5 A 6.1 3'-0"7'-0"3'-0"6'-8" VIF3'-0" CORIAN SLAB WITH EXPOSED FASTENERS SYMBOL A B C D LOCATION NOTESB.O.HDESCRIPTION 3'-0 X 3'-6" EXTERIOR ALUMINUM AWNING WINDOW W/ INSULATED GLASS, & CLEAR ANODIZED ALUMINUM FRAME. 7'-4" AFF, VIF 7'-4" AFF, VIF 7'-4" AFF, VIF 7'-0" AFF, VIF3'-10"3'-6"3'-0"3'-10"3'-6"1'-8"3'-10"3'-6"3'-6"3'-6"3'-6"3'-6" CONTRACTOR TO VERIFY EXISTING MASONRY OPENING FOR NEW WINDOW INSTALLATION. IF SPACE ALLOWS, CONTRACTOR TO INSTALL NEW XPS INSULATION AROUND WINDOW OPENING, TRIM WITH BORAL, PAINTED. OFFICE/ LARGE WASH, 109 OFFICE/ LARGE WASH, 109 GROOMING/ KENNEL, 103 SELF GROOMING, 104 QTY. 1 1 1 4 1'-8" X 3'-6" EXTERIOR ALUMINUM AWNING WINDOW W/ INSULATED GLASS, & CLEAR ANODIZED ALUMINUM FRAME. 3'-6" X 3'-6" EXTERIOR ALUMINUM AWNING WINDOW W/ INSULATED GLASS, & CLEAR ANODIZED ALUMINUM FRAME. 3'-6" X 3'-6" INTERIOR FIXED INSULATED GLASS VIEWING PANEL W/WOOD AND/OR METAL FRAME. PRIMED & PTD COLOR TO BE SELECTED BY OWNER. DIM. SYMBOL LOCATION NOTESB.O.HDESCRIPTIONQTY.DIM. KAWNEER 350 STANDARD ENTRANCE DOOR W/ 1/2 HEIGHT INSULATED GLASS VISION PANEL & CLEAR ANODIZED ALUMINUM FRAME. 3'-0" X 7'-0" 7'-0" AFF, VIF GROOMING/ KENNEL, 103 SELF GROOMING, 104 EGRESS COLLECTION, 105 3 SEE PLAN FOR FROSTED ETCHED GLASS LOCATION* SOLID CORE BIRCH VENEER WOOD SLAB DOOR W/ HOLLOW METAL FRAME PRIMED & PTD ON SITE. COLOR TO BE SELECTED BY ARCHITECT. 3'-0" X 7'-0" 7'-0" AFF, VIF UTILITY, 106 HP TOILET, 107 2 THERMA-TRU - PULSAR LINEA W/ FULL HEIGHT VISION PANEL OFFSET RIGHT - PRE-HUNG EXTERIOR DOOR. PRIMED & PTD, COLOR TO BE SELECTED BY ARCHITECT. 3'-0" X 6'-8" - S1RXJ 6'-8" AFF, VIF BREAK ROOM, 1081 7'-0" AFF, VIF UTILITY, 106 HP TOILET, 107 2STEEL DOOR W/ 1/2 HEIGHT INSULATED GLASS VISION PANEL & HOLLOW METAL FRAME, PRIMED & PTD. COLOR TO SELECTED BY ARCHITECT. 3'-0" X 7'-0" GENERAL DOOR & WINDOW NOTES: - ALL DOORS TO HAVE LCN-1260 CLOSER, AS REQUIRED. - STANDARD DOOR & WINDOW HARDWARE TO BE SELECTED BY ARCHITECT NO THRESHOLD, AS REQUIRED. DOOR TO BE INSTALLED GYP OPENING. NEW PAINTED 2" TRIM ON BOTH SIDES OF DOOR. NO THRESHOLD, AS REQUIRED. NO THRESHOLD, AS REQUIRED. DOOR GOING INTO EXISTING MASONRY OPENING W/ ADA THRESHOLD .7'-0"CONTRACTOR TO VERIFY EXISTING MASONRY OPENING FOR NEW WINDOW INSTALLATION. IF SPACE ALLOWS, CONTRACTOR TO INSTALL NEW XPS INSULATION AROUND WINDOW OPENING, TRIM WITH BORAL, PAINTED. CONTRACTOR TO VERIFY EXISTING MASONRY OPENING FOR NEW WINDOW INSTALLATION. IF SPACE ALLOWS, CONTRACTOR TO INSTALL NEW XPS INSULATION AROUND WINDOW OPENING, TRIM WITH BORAL, PAINTED.