Loading...
BP-75514sI i l• 45 b` MTA#680 MISHAUM POINT RENOVATION 143 MISHAUM POINT ROAD, SOUTH DARTMOUTH, MA architgct MARYANN THOMPSON ARCHITECTS 741 Mount Auburn St. Watertown, MA 02472 Contact: Adam Murfield (617) 744-5187 x117 adam@maryannthompson.com or Maryann Thompson t (617) 480-5425 maryann@maryannthompson.com structural engineer FRED COWEN ENGINEERS Consulting Structural Engineers 29 Vesta Road Natick, MA 01760 Contact: Ray Busser rbusser.cowen@gmail.com t (508) 655- 3976 f (508) 655- 4284 NAN INDEX ' r 1A1l r u - ' w must Be Kept Dry Sillb F�'1 iFf Co k{U(;u$ §4 TITLE TITLE PAGE ARCHITECTURAL 01.0 DEMO. PLAN - FIRST FLOOR • D1.1 DEMO. PLAN - SECOND FLOOR • A1.0 BASEMENT PLAN W. MECH. NOTES • A1.1 FIRST FLOOR PLAN A1.2 SECOND FLOOR PLAN A1.3 ROOF PLAN A1.4 RCP A2.0 EXT. ELEVATIONS A2.1 EXT. ELEVATIONS • A2.2 EXT. FIN. SCHD/ EXT. DETAILS A3.0 WINDOW/DOOR SCHD. A4.0 BLDG. SECTIONS A4.1 BLDG. SECTIONS ` A4.2 BLDG. SECTIONS E7.0 ELECTRICAL PLAN E1.1 ELECTRICAL PLAN/SCHEDULE • STRUCTURAL S0.1 STRUCTURAL DETAILS S1.0 STRUCTURAL DRAWINGS Plan Date Date i ADDITIONAL BID DOCUMENTS: 680 SPECIFICATIONS (8.5 x 11) CUTSHEETS REMOVE EXISTING TREE IF NECESSARY DEMO EXISTING WALL DEMO EXISTING STAIR REMOVE ALL EXISTING CEILING AND WALL FINISHES IN BEDROOM REMOVE AND SET ASIDE CLOSET DOORS FOR REUSE IN SAME LOCATION, CLOSET REPAIR BY OWNER REMOVE EXISTING INTERIOR WALL FINISHES AS SHOWN REMOVE EXISTING DECK STEPS AT THIS LOCATION REMOVE AND RELO — — _ — — _ EXISTING ELECTRIC I �j + � — PANEL JA"� LF �I / T //\� BEoo2 REPLACE EXISTING DEMO EXISTING DEMO EXISTING SINK WITH NEW TILE HEARTH OUTDOOR SHOWER ' PEMO EXISTING I ENCLOSURE AND WALLA GLE o MAINTAIN LIVING REMOVE EXISTING PLUMBING IN ITS GUEST BED ..... -....... _ EXISTING WOOD STOVE AND ' ENTIRETY REi MOVE EXISTING I BATH TOILET! TUB � plpE -- 0' D ORS _ _ DELq EXISTING .. _I MASONRY CHIMNEY _�---l--- Ell J — — — — 7 �TOV�/� DOOR,REMOVE IDENTING L I� }L� 7 OUTDOOR n I SHOWER ' MAINTAIN EXISTING VENT PIPE HALL \ DOOR WAY CLO , i ?.�/J MODIFY VENT LOCATION WHERE > lJ SM. BATH J ' IT TURNS TO SECOND FLOOR ___ _ __ ....... REMOVE ALL WALL AND F FRAMING---- CEILING FINISHES IN HALL. II _ r — MAINTAIN STRUCTURE. CLO � � DEMO ENTIRE BATH, ' DEMO EXISTING CLOSET AND — _ _�J� BATH FIXTURES AND ' WALLS SINK \� REMOVE ALL EXISTING — — CLOSETS FI FR (I � CASEWORK IN KITCHEN t \ RE F DINING \ � BED-01 � % ' C L� /\ \ ------------ KITCHEN �J ALL EXISTING WOOD FLOOR DEMO WALL ' - MASTER BED L � TO REMAIN. PATCH FLOOR I BETWEEN LIVING CLO. WHERE DISTURBED, GC TO AND BEDROOMS ' PROTECT FLOORING ' DURING CONSTRUCTION ELEC. J METEREN ' �ryL r��DN _ 1 RELOCATE EXISTING ELEC. METER CLOSER �� — — — — — — — — — — w PANTRY TO POLE ENTRY ti REUSE EXISTING NORTH REMOVE EXISTING CEILING \ , DECK OVER NEW AND WALL FINISHES IN - - FOUNDATIONS MASTER BED REMOVE EXISTING KITCHEN ' ON REMOVE EXISTING CASEWORK/ SHELVES, MASONRY CHIMNEY PLUMBING FIXTURES, AND APPLIANCES LAUNDRY REMOVE EXISTING TREE AS NEEDED DEMO EXISTING❑� PANRY/LAUNDRY BUMPOUT I SET ASIDE EXISTING W/O FOR REUSE 01 FIRST FLOOR DEMO SCALE: 1 /4"=V-0" REMOVE EXISTING SHRUBS IF NECESSARY O01' 5' 10' 20' ECK REMOVE EXISTING TREE AS NEEDED REMOVE EXISTING ENTRY DECK AND RAILING 'ATE ------- ANOPYABOVE- \ --. _ ... 10 GUEST POD NOTE: • EXIST ING GUEST POD TO REMAIN FUNCTIONAL DURING CONSTRUCTION. UTILITIES TO BE MAINTAINED TO POD. • GC TO PROTECT POD STRUCTURE FROM DAMAGE DURING CONSTRUCTION. D MOVE EXISTING KEY: LIMIT OF WORK DEMOLISH EX EXISTING WINDOW/ DOOR TO REMAIN GENERAL NOTES: • ALL UNMARKED WINDOWSIDOORSTO BE MAINTAINED. • PROVIDE ALL NEW ELECTRICAL WIRING WIRING IN THE MAIN HOUSE. • REMOVE ALL EXISTING HOMASOTE WALL AND CEILING FINISH IN FIRST FLOOR. • REMOVE ALL INTERIOR/ EXTERIOR FINISHES SHOWING ROT/DECAY WITHIN THE LIMIT OF WORK. • GC TO HAUL OFF ALL DEBRIS FROM SITE IN A LAWFUL MANNER • SET ASIDE REUSABLE MATERIALS INCLUDING - INTERIOR WOOD PANELS, WOOD DOORS, DOOR HARDWARE FOR REUSE. • CONSULT OWNER BEFORE REMOVING MAJOR TREES/ SHRUBS ADJACENT TO THE MAIN HOUSE. MARYANN THOMPSON ARCHITECTS 741 Mount Auhum Strut Watertam, MA 02472, tel: (617) 744- 5187 fax: (617) 491- 3844 C M—Nrno ONggcWTac,s < O C L C C) O a° E E as :3n CISL m 2 0 CO z_ O a. G N m 0 co cc C� G ICONSULTANTS: I STRUCTRAL ENGINEER COWEN ASSOCIATES 29 Vesta Road Natick, MA 01760 (508) 655-3976 Ray Busse, my@co—nassoc.00m I REVISIONS: I CURRENT ISSUE: SET DATE CURRENT SET 10.0t.2014 DRAWING TITLE: DEMO 01 SECON[j FLOOR DEMO PLAN SCALE: 1/4"=1r-0" REMOVE WD. SHELF jFAMILY ROOM F---� — MAINTAIN EXISTING WD. FLOOR, _ PROTCONECT DURING STRUCTION REMOVE EXISTING — WOOD STOVE/ HEARTH REMOVE EXISTING - WINDOWS, TYP. KEY: LIMIT OF WORK DEMOLISH CED EXISTING WINDOW/ DOOR TO REMAIN GENERAL NOTES: • ALL UNMARKED WINDOWS/DOORS TO BE MAINTAINED. PROVIDE ALL NEW ELECTRICAL WIRING WIRING IN THE MAIN HOUSE. • REMOVE ALL EXISTING HOMASOTE WALL AND CEILING FINISH IN FIRST FLOOR. • REMOVE ALL INTERIOR/ EXTERIOR FINISHES SHOWING ROT/DECAY WITHIN THE LIMIT OF WORK. • GC TO HAUL OFF ALL DEBRIS FROM SITE IN A LAWFUL MANNER + SET ASIDE REUSABLE MATERIALS INCLUDING - INTERIOR WOOD PANELS, WOOD DOORS, DOOR HARDWARE FOR REUSE. • CONSULT OWNER BEFORE REMOVING MAJOR TREES/ SHRUBS ADJACENT TO THE MAIN HOUSE. MARYANN THOMPSON ARCHITRCTS 741 Mount Aubuk5A Street Watertown, MA Q&72 tel: (617) 744- 511%7 fax: (617) 491- 3✓9'a4 C MA0.vAUHTHOMa80W/AscHnIs m O� C t C 7 O a° E E m m I L t i N j O Cl) Cl) z 0 o. a x CCCO) G I' W CO I 'a CONSULTANTS: STRUCTRAL ENGINEER COWEN ASSOCIATES 29 Vesta Road Natick, MA 01760 (508)655-3976 Ray Susser ray@cowenassac.com CURRENT ISSUE: SET DATE CURRENT SET 10.01.2014 DRAWING TITLE: DEMO 0 1' S 10' 20' D 1.1 O ram — — — — — — — — — — — — — — — — — — — — — — — — 40 _ r 4 NEW STAIRS 1 ABOVE PROVIDE ALL NEW CONCRETE 1 FOUNDATIONS FOR DECKS, SEE 1 STRUCTURAL __ 7 D KABOVE _.... _ I NEW DECKABOVE �NEW I I - ............. t� .. _..... . __- _ ... L _ J 1 DN 1 I' PULL DOWN STAIRS TO BASEMENT, PROVIDE 1 SUBMITTAL. - BULKHEADSTEPSTO PROVIDE OPENINGS AS BASEMENT, INSULATED DOORS AT BASEMENT LEVEL. - 1 REQUIRED FOR PROVIDE SUBMITTAL. VENTING 8' HIGH BASEMENT SPACE - 1 1 NEW STRUCTURAL 1 COLUMNS TYP. SEE - 1 O '', STRUCTURAL DRAWINGS j 1 LOCATE DECK/ p p STAIRS ABOVE , 1 NEW FOUNDATION To MATCH O� NEW CONCRETE RAT SLAB. EXNG SIZE ND AND 1 1 1 ; -- -- - - -- - ..... --- ........ -- - 1 ... .....-- ---- -- — ..-... — — --- - ...... _ ' GENERAL NOTES ON CONC. FOUNDATION • SEE STRUCTURAL DRAWINGS FOR MORE INFORMATION • FOUNDATION WALL TO BE REINFORCED CONC. WALL W/ BETONITE WATERPROOFING AND 1' RIGID INSULATION. • PROVIDE FILTER FABRIC AROUND CURSHED STONE AT FOOTING. • PROVIDE PERFORATED PVC FOOTING DRAIN AT FOUNDATION PERIMETER. DRAIN TO DAYLIGHT 01 PROPOSED BASEMENT PLAN SCALE: 114-=1 r-0" O0 1' 5' 10' 20' LOCATE CASEMENT EGRESS WINDOW AND WINDOW WELL IF REQUIRED BY CODE FOR SECOND MEANS OF EGRESS FROM BASEMENT. PROVIDE ADDIALT. NEW DEOK ABOVE 1 1 I I I 1 I CJ ' PROVIDE NEW CONTINUOUS CONCRETE FOUNDATION UNDER EXISTING HOUSE. SET TOP OF FOOTING TO ACHIEVE A F.F. AT 3T ABOVE GRADE MAX ON OCEAN SIDE OF HOUSE TO AVOID RAILINGS AT OCEAN -FACING DECK. MAINTAIN EXISTING DECK ABOVE KEY: LIMITOFWORK VOLUME TO BE WINTERIZED NEW INSULATION XX NEW WINDOW = EXISTING DXX NEW DOOR GENERAL NOTES: • GC. TO PROVIDE ALL NEW ELECTRICAL WIRING AT MAIN HOUSE. • ALL UNMARKED WINDOW/ DOORS INDICATE EXISTING TO REMAIN. PROVIDE NEW PAINT ON ALL EXISTING DOORS/ WINDOWS. • REMOVE ALL EXISTING HOMASOTE WALL/ CEILING FINISH IN FIRST FLOOR • REMOVE ANY INTERIOR FINISH SHOWING ROT OR DAMAGE WITHIN THE LIMIT OF WORK. + MAINTAIN ALL EXISTING GUTTERS AND DOWNSPOUTS U.O.N. • ALL FURNITURE BY OWNER U.O.N. • PROVIDE ALLOWANCE FOR ALL KITCHEN CASEWORK/ APPLIANCES/ CLOSET/ STORAGE. • SEE EXTERIOR FINISH SCHEDULE FOR MORE INFORMATION. • SEE STRUCTURAL DRAWINGS FOR MORE INFORMATION. • ALL NEW PLANTINGS/ FINISH LANDSCAPING BY OWNER MARYANN THOMPSON ARCHITECTS 741 Mount Au um Street Watertown, MA 02472 tel: (617) 744- 5137 fax: (617) 491- 3944 o uurvnuuTx«msou uicuescTs ICONSULTANTS: I STRUCTRAL ENGINEER: COWEN ASSOCIATES 29 Vesta Road Natick, MA 01760 (508)655-3976 Ray Busser 2y@cowenasso m I REVISIONS: I CURRENT ISSUE: SET DATE CURRENT SET 10.Ot.2014 DRAWING TITLE: FLOOR PLAN A1.0 STEPS ALL THE WAY ACROSS DECK. REGRADE TO PROVIDE FLAT SURFACE FOR STEPS TO CONNECT TO GRADE I NEW WD. DECK, SEE ' EXT. FIN. SCHD. O-O' HIGH WRC. SCREEN RELOCATE EXISTING ' DOWNSPOUT PROVIDE BULKHEAD TO I BASEMENT. WD T&G ' DOORS. N ' 'LOCATE HEAT PUMPS AT O THIS LOCATION, PROVIDE CONCRETE SLAB. PROVIDE INSULATION FOR...... ALL HAVC PIPING/DUCTING i \ IN BASEMENT OR AS NEEDED, i i !. HEAT PUMPS TO SUPPLY ' HEAT AND AC TO 3 ZONES: \�\ L/DR/K, 1ST FLOOR BEDROOMS, AND 3RDFLOOR BEDROOM - 'HEAT PUMP SYSTEM TO DELIVER THRU FLOOR ON 'BOTH ISTAND 2ND FLOOR. DE YT01ST FLOOR T U e EMENT. '7-177-� NDL ER�_�._N BENCH 0"A4.0 ■NORTH DECK.......... . ......... . ......... ...... .... ......... 02/A4.1 ' — e ........... .... .. - - ------ - ......... . . :::= - ----- i II O'ZV/ZO MARYANN ¢ , o ARCHITECTS ARCHITECTS — - — — — — — — — — — — � � � � � h� .. �� � � � � � � � � � � � � � � � � � 741 Mount Auhum Street _ - ` STEPS TO MEET CODE Watertown, MA 02472 DN �? ;' "--� AND HIT GRADE tel: (617) 744-6137 ' ACCURATELY AND LEVEL. fax: (617) 491- 3844 ?' \� • ;'--� N \ /'' NUMBER OF STEPS TO BE ,_._.. _. _.� DETERMINED IN FIELD \ C MAarnuNT'wMPsoMxacnnFCTs \ EEKLANDSCAPE SCOPE MORE I'.T77777 �— \ INFORMATION) CC L _ / _ o it il. _ O `' N l EAS03SEC \ '. D110 / / EAST D K 03 ._ / _ _ , ' NEW GRANITE LANDING AND STEPS TO GRADE 8Y GC x PROVIDE EXTERIOR GAS( WATERtOIG&I �— ' \ \ HALL % n i-�-' is ,.. .. _ CLOSET REPAIR (REUSE EXISTIN BY OWNER. GC TO PROVIDE TUB IN N WIRING FOR LOCATION CLOSET SEE EL CTRICAL BED-02 ,OS I I BUREAU BYOWIIER MODIFY $TACK VENT. TURN VENT UPWARDS @ WALL IN HALL HVAC CHASE BED-01 1 107 1 1 I 107-2 107-t HALL o 106 \ o _— lI O v Dw II ' II I SINK KITCHEN 1 1 t04 I II � I - D w 11 REUSE EXISTING DECK OVER NEW FOOTINGS NEW WATER HEATER IN CASEWORK. CASEWORK AT WEST WALL TO BE SIZED NEW STAIRS TO BE CORRECTLY SIZED TO CONCEAL HOT HEATER AND REQUIRED TO MEET GRADE APPROPRIATELY PIPING WITH NEW FOUNDATION, TYP. PROVIDE ALLOWANCE FOR ALL KITCHEN CABINETS AND APPLIANCES REUSE EXISTING WASHER AND DRYER PROVIDE HOSE BIB 2'-0- BENCH, CLOSED ON BACK AND SIDE. WOOD STORAGE BELOW. 01 PROPOSED FIRST FLOOR PLAN SCALE: 1/4"=1'-0" 01' S' 10' 20' HATCH IN FLOOR TO BASEMENT. PROVIDE I 1 SUBMITTAL. NEW SOLAT E ABOVE REPLACE EXISTING WITH NEW SINK LI STONE TILE-1 UNDER WIDEN WOOD STOVESEE EXISTING 1 ' i (� DOORWAY, -ZERO-CIENRANCE Intl REVERSE FIREPLACE AT COLUMN SWING PROVIDE OFF -CENTER AVOID STACK TO AVOID \ SEA)FAHOVE N EW IICOLUM ,SEE 4 0` STRUCTU ' CO+N _IF - DINING 103 1 - MAINTAIN EXISTING BEAM ABOVE I - NEW HOOKS BELOW WINDOWS DN FUR OUT ALL EXT. WALLS TO THE INTERIOR TO FIT MIN. 5.5' THICK INSULATION, TYP. ALL EXT. WALLS 1ST AND 2ND FLOOR. NEW MAHOGANY WD. DECK 12" WIDE STEP IF NEEDED NO RAILING. KEEP DECK LESS THAN 30' ABOVE GRADE. GRADE UP TO DECK IF NECESSARY. J GUEST POD NIC. I KEY: tttttttttt LIMIT OF WORK VOLUME TO BE WINTERIZED =- — ._" NEW INSULATION XX NEW WINDOW EX EXISTING DXX NEW DOOR GENERAL NOTES: • GC. TO PROVIDE ALL NEW ELECTRICAL WIRING AT MAIN HOUSE. • ALL UNMARKED WINDOW/DOORS INDICATE EXISTING TO REMAIN. PROVIDE NEW PAINT ON ALL EXISTING DOORS/ WINDOWS. • REMOVE ALL EXISTING HOMASOTE WALL/ CEILING FINISH IN FIRST FLOOR • REMOVE ANY INTERIOR FINISH SHOWING ROT OR DAMAGE WITHIN THE LIMIT OF WORK. • MAINTAIN ALL EXISTING GUTTERS AND DOWNSPOUTS U.O.N. • ALL FURNITURE BY OWNER U.O.N. • PROVIDE ALLOWANCE FOR ALL KITCHEN CASEWORK/ APPLIANCES/ CLOSET/ STORAGE. • SEE EXTERIOR FINISH SCHEDULE FOR MORE INFORMATION. • SEE STRUCTURAL DRAWINGS FOR MORE INFORMATION. • ALL NEW PLANTINGS/ FINISH LANDSCAPING BY OWNER Z C0- G C4 cc cc � li: F CONSULTANTS: STRUCTRAL ENGINEER: COWEN ASSOCIATES 29 Vesta Road Natick, MA 01760 (608)655-3976 Ray Bu Wen 2Y@co asaoc.corn I REVISIONS: I CURRENT ISSUE: SET DATE CURRENT SET tO.Ot. DRAWING TITLE: FLOOR PLAN A1.1 01/A4.0 03/A4.1 02/A4.1 CLERESTORY WINDOWS ------ INTO STORAGE ABOVE. CENTERED ON STAIRS PROVIDE INSULATION AT FLOOR/CEILING, WALLS OF BATH STORAGE @ SECOND FLOOR PAINTED PINE FLOOR TO MATCH EXISTING IN NEW POWDERROOM NEW DORMER NEW BATH FIXTURES @ POWDER ROOM, SEE PLUMBING REPAIR FLASHING WHERE ROOF MEETS WALL FINISH TO MATCH EXISTING MAINTAIN EXISTING WOOd FLOOR. € ' - -TIN--- --- SOLATUBE LIGHT INTO BATI BELOW. WRAP WITH MARIN OOM OPE- STORAGE' o -- (HEMP) 203 I' _-- D203 i - J I I I ) _ -- NEW STOVE PIPE _ - PATCH AND REFINISH ...... AT ALL j� LOCATE NEW SKYLIGHT AT '-- DISRUPTED AREAS ' J CENTERLINE OF STAIRS IF ` WITH SHINGLES TO PDR. _. SKYLIGHT REDR -03 OM POSSIBLE. j -- MATCH EXLS7WG ' 204 DNS TAIRS 2 1 RASH AND FLASH A5 THREE NEW SKYLIGHT _ �OCOG ' ABOVE. SEE A1.3 FOR -- ALL FLASHING TO BE MORE INFORMATION. 48N. 7-0'ABOVE ' r--� - ADJACENT SURFACE \ J ' _T-------- PROVIDE INSULATED DOOR ) __ ' ! 1- I 2o1-s zo1Hi zola 2D1-B NEW INSULATION AT BATHROOM WALLS AND CEILING SECOND FLOOR NOTES: MAINTAIN ROOM/BEAMS/CEILING TO REMAIN 'AS IS' WITH THE EXCEPTION OF NEW BATHROOM, NEW STORAGE AREA AND REPLACED WINDOWS ALL SUPPLY PIPES IN THE SECOND FLOOR TO BE DRAINED DURING WINTER MONTHS FOR WINTERIZATION. CONFIGURE PLUMBING ACCORDINGLY. 01 PROPOSED SECOND FLOOR PLAN J J L SCALE: 1/4"=1'-0" O01, 5' 10' 20' FUR OUT ALL EXT. WALLS TO THE INTERIOR TO FIT MIN. 5.5' THICK INSULATION, TYP. ALL EXT. WALLS 1ST AND 2ND '.. FLOOR MAINTAIN EXISTING EXPOSED ROOF STRUCTURE & WOODEN 02/A2.1 J N Q O µ I w KEY: •� •� LIMIT OF WORK VOLUME TO BE WINTERIZED 0�ar NEW INSULATION NEW WINDOW EX EXISTING DXX NEW DOOR GENERAL NOTES: • GC. TO PROVIDE ALL NEW ELECTRICAL WIRING AT MAIN HOUSE. • ALL UNMARKED WINDOW/DOORS INDICATE EXISTING TO REMAIN. PROVIDE NEW PAINT ON ALL EXISTING DOORS/ WINDOWS. • REMOVE ALL EXISTING HOMASOTE WALL/ CEILING FINISH IN FIRST FLOOR • REMOVE ANY INTERIOR FINISH SHOWING ROT OR DAMAGE WITHIN THE LIMIT OF WORK. • MAINTAIN ALL EXISTING GUTTERS AND DOWNSPOUTS U.O.N. • ALL FURNITURE BY OWNER U.O.N. • PROVIDE ALLOWANCE FOR ALL KITCHEN CASEWORK/ APPLIANCES/ CLOSET/ STORAGE. • SEE EXTERIOR FINISH SCHEDULE FOR MORE INFORMATION. • SEE STRUCTURAL DRAWINGS FOR MORE INFORMATION. • ALL NEW PLANTINGS/ FINISH LANDSCAPING BY OWNER MARYANN THOMPSON ARCHITECTS 741 Mount Auburn Street Watertovm, MA 02472 tel: (617) 744-5187 fax: (617) 491-3844 0 Q O� c 1 C � O d E to cri M 0 CO Z JCC1 G Q CD co t0 CONSULTANTS: STRUCTRAL ENGINEER COWEN ASSOCIATES 29 Vesta Road NatEk, MA 01760 (508)655-3976 Ray Busser ray@mwenassoacom I CONTRACTOR: REVISIONS: I CURRENT ISSUE: SET DATE CURRENT SET iD.01. DRAWING TITLE: FLOOR PLAN A1.2 MARYANN THOMPSON ARCHITECTS 17 741 Mount Aulxem Street Q ZV/Z0 Q Watertown, MAM472 0O tel: (44-5187 faz: (617) (617) 491. 3844 p uAnvvv lvaaasay.Aac`nrecrs Q O� c _ c 3 SKYLIGHT SCHEDULE: 3 NEW SKYLIGHTS 0 °E f, E� TAG# OPERATION WIDTH HEIGHT MANUF TYPE _...... ____ REMARKS ...__— ___ ........ ........_. E as L GHT NEW NTERLI EO CENTERLINE OF SKY-1 MANUALLYVENTING VELUX OR GC TO VERIFY SKYLIGHT DIMENSIONS N " ._ 7 STAIRS BELOW. _ _ - _-- MATCH DECK SKY-2 MANUALLY VENTING 1 �" VIF. 2.11' VIF. EXISTING MOUNTED ON SITE. INSTALL PER MANUFACTURER'S INSTRUCTIONS. � O :_-- ..... MANUF. PROVIDE INSECT SCREEN V NEW SOLATUBE SKY-3 MANUALLY VENTING _. 1 __. ......._._ ............ ............_ _ - .. .... .. ... .........__ .......... ............. , r SKYLIGHT. FLASH _. ...... _. ..__— AND COUNTERFLASH. O s - ' I _ - r — _ - k .—` — — — REPLACE EXISTING SKYUGHi WRH NEW ,.... ' • : WITHIN THE EXISTING --- -_.L,— _.- OPENING, TYP. ' ' NEWLY RELOCATED METAL VENT PIPE. — — ' WRAP IN FREEDOM ~ __ GRAY METAL WRAP •,.. ..f I I __ _ _ NEW SHED DORMER OVER PROPOSED _— I ' I POWDER ROOM. CEDAR 'i —� a i_I— , — --t _ —_ SHINGLE TO MATCH 01/A4.0 ' EXISTING. ,--t 1 I I I PROVIDE ICE AND WATER — NEW METAL VENT 03/A4.1 SHIELD. CONTINUOUS _ - ' ' WATER BARRIER AT NEW �' FLASH! COUNTERFLOASH SHED DORMER UNDER 1 _ _—_ PER MANUFACTURER'S I SHINGLES 8: LAPPING NSTRUCTKNS ' UNTO ROOF MIN. 4'-0" —� — _ - _ _ PROVIDE METAL CHIMNEY SUPPORT AS - ' 'FLASH AND COUNTERREQUIRED. FLASH WHERE NEW ' ROOF MEETS EXISTINGTYP, -L El— :.: — — — — — — — REPLACE EXISTING ROOF WITH WHITE CEDAR SHINGLE ROOF, SELECT A, TO MATCH EXISTING. 01 PROPOSED ROOF PLAN SCALE: 1 /4"=1'-0" O0 1' 5' 10' 20' J J J-doftilb- 02/A2.1 J KEY: LIMIT OF WORK VOLUME TO BE WINTERIZED L, _; NEW INSULATION ® NEW WINDOW EX - EXISTING DXX NEW DOOR GENERAL NOTES: • GC. TO PROVIDE ALL NEW ELECTRICAL WIRING AT MAIN HOUSE. • ALL UNMARKED WINDOW/DOORS INDICATE EXISTING TO REMAIN. PROVIDE NEW PAINT ON ALL EXISTING DOORS/ WINDOWS. • REMOVE ALL EXISTING HOMASOTE WALU CEILING FINISH IN FIRST FLOOR • REMOVE ANY INTERIOR FINISH SHOWING. ROT OR DAMAGE WITHIN THE LIMIT OF WORK. • MAINTAIN ALL EXISTING GUTTERS AND DOWNSPOUTS U.O.N. • ALL FURNITURE BY OWNER U.O.N. • PROVIDE ALLOWANCE FOR ALL KITCHEN CASEWORK/ APPLIANCES/ CLOSET/ STORAGE. • SEE EXTERIOR FINISH SCHEDULE FOR MORE INFORMATION. • SEE STRUCTURAL DRAWINGS FOR MORE INFORMATION. • ALL NEW PLANTINGS/ FINISH LANDSCAPING BY OWNER wl V C� G FVeStaRcad TANTS: L ENGINEER: SOCIATES oad 01760976mynassoc.com I REVISIONS: CURRENT ISSUE: SET DATE CURRENT SET t0.01.2014 DRAWING TITLE: ROOF PLAN A1.3 01 PROPOSED FIRST FLOOR RCP SCALE: 1 /4"=T-0" AS REQUIRED Td ""— BEADBOARD,TYO: THROUGHOUT ALL CALLED -OUT 'BEADBOARD' Af@EILING �6� AND ELEVATION WALLS TO BE T&G PRIMED PINE, V-GROOVE, 4" FAGER STANDARD SIZE: PROVIDE SUBMITTAL PAINTED BEAD§@ARD ON ALL EXPOSED V€RTICAL SURFACE, TYP. SOLATUBE PENETRATION. LOCATE BETWEEN ROOF BEAMS MAINTAIN EXISTING WOOD TIE BEAM LOCATE NEW SKYLIGHT, CENTERLINE OF STAIRS, VIF. ALL NEW SKYLIGHTS TO BE THE SAME SIZE. PAINTED GWB. CEILING @ POWDER ROOM. EXPOSED WD. JOISTS 02 PROPOSED SECOND FLOOR RCP SCALE: 1 /4"=1'-0" GENERAL NOTES: • PROVIDE FURRING STRIPS FOR CEILING AND OR WALL FINISH AS REQUIRED. • PROVIDE 2- WD. TRIM @ TRANSITIONS. • SEE A5.0 INTERIOR FINISH SCHEDULE FOR MORE INFORMATION • ENTIRE HOUSE TO BE REPAINTED, COLORS, TBD. BILE SKYLIGHT 3. NEW SKYLIGHT IG OPENING. SH AS REQUIRED. MARYANN THOMPION ARCHIT5bTS 741 Maunt Aub , Street Watertown, MA @2472 tel: (617) 744- 5187 fax: (617) 491- 3844 0 Ma � Q O O I E Q as rn O C7 U) 7 eta Z u 0 V OCC. G a ;.x CA C7 00 CC CONSULTANTS: STRUCTRAL ENGINEER COWEN ASSOCIATES 29 Vesta Road Natick, MA 01760 (508)655-3976 Ray Basser ray@cowenaasoc.com Vpl....1.2.14 DRAWING TITLE: MAINTAIN EXISTING EXPOSED RCP ROOF STRUCTURE & WOODEN CEILING STRUCTURE. 0 1' 5' 10' 20' Al A O 6'-0" HIGH WD. SCREEN @ EAST DECK. SEE A2.2 FOR DETAILS HEAT PUMP LOCATION, PROVIDE CONCRETE SLAB PROPOSED NORTH ELEVATION SCALE: 1/4"=1'-0" T.O. NEW�ROOF� 13'-2° Y 02 PROPOSED EAST ELEVATION SCALE: 1 /4"=1'-p^ NEW METAL STACK VENT, PTD. SILVER METAL COLOR NEW CEDAR SHINGLES. NEW SHED DORMER. ROOF EDGE TO MATCH EXISTING IN COLOR AND SIZE. NEW WHITE CEDAR SHINGLES, ENTIRE ROOF AND DORMER TO MATCH EXISTING. REUSE EXISTING DECKING AND STAIRS AT THIS LOCATION, PROVIDE NEW CONC SUPPORTS q STOVE PIPE ON COLUMN IN LIVING RM NEW METALCHIMNEY FOR WOOD BURNING STOVE. PROVIDE BRACING AS RED. z 10'-0' 105-4 101K +Y� Trl • NEW ROOF 1/4• FY 10'-31Y2• F4r� PROVIDE CORRECT # OF STEPS TO HIT GRADE ACCURATELY. STEPS TO BE EQUAL HEIGHT AND WIDTH TO MEET CODE REQUIREMENTS. RE -GRADE AS REQUIRED TO ALLOW LEVEL SURFACE FOR STEPS TO MEET MARYANN THOMPSON GENERAL NOTES: ARCHITECTS • SEE EXTERIOR FIN. SCHEDULE FOR 741 Mount Auburn Street Watertown, MA 02472 MORE INFORMATION. • PATCH/ REFINISH ALL EXISTING tel: (617) 744-5187 fax: (617)491_3844 SURFACES WHERE DISTURBED. MATCH DETAILS TO EXISTING. u+cNrrec ® uAa`'ANN TM°u NxNcts as � 0 O d � _ C 7 O d E E f O Rf L nco co 7 FASCIA TO BE PAINTED WRC, TYP. MOLDING TO ORIGINAL A-. DIMENSION AS NEEDE NEW RIGID INSUI 03 TYPICAL TRIM DETAIL (DIMENSIONS) 6CALE:3•=1'-0• INSULATED ENTIRE ROOF WITH RIGID INSULATION ABOVE EXISTING WOOD CEILING WITH RIGID TO MEET CODE. THICKEN ROOF FASCIA AS NECESSARY TO COVER INSULATION. NEW WINDOWS, SEE WINDOW SCHEDULE. PTD. WD. CASING TO MATCH EXISTING, TYR NEW SHINGLE WALLS AT SIDE OF DORMER TO MATCH SHINGLES AT VERTICAL WALLS. / NEW SHED DORMER BEYOND THICKEN FASCIA TO MATCH THICKENED ROOF. SEE 03/A2.0 FOR MORE INFORMATION. PATCH EXT. FINISH WHERE DISTURBED TO MATCH EXISTING, TYP. lamm 1111110111 Z O CL MCC co +Y O• ROOF /- 23'-2' CONSULTANTS: STRUCTRAL ENGINEElb COWEN ASSOCIATES 29 Veda Road NalEk, MA 01760 (508)655-3976 Th O.NEW ROOF Ray Busser 12•-6p1/4^ ray@oowenassoo.00m �V Fq� 10'-31/2" SET DATE CURRENT SET 10.01.2014 DRAWING TRLE: EXT. ELEVATIONS a� n WOOD BENCH SURFACE TO BE T&G SO RAIN DOESN'T GO THROUGH. SLOPE SURFACE 2%TO DRAIN. PROVIDE RUBBER MEMBRANE STRIP UNDER BENCH TO PROTECT WOOD FROM RAIN NEW DECK AND BENCH AT J / ENTRYEXT - WOOD STORAGE UNDER PATCH DISTURBED SIDING BENCH WHERE DISTURBED, TYP. 0 1 PROPOSED SOUTH ELEVATION SCALE: 1 /4"=V-0" NEW SHED DORMER BEYOND NEW SHINGLE WALLS AT SIDE OF DORMER ALIGN TOP OF WINDOWS/DOOR, TYP. 6'-0' HIGH WRC. SCREEN @NORTH — DECK. 1.4 WRC SLATS WITH T' GAP. 4x4 WRC POSTS AND WRC CAP @TOP .t__........ ____—.......... NEW NORTH DECK J 02 PROPOSED WEST ELEVATION SCALE: 1 /4"=V-0" STAINLESS STEEL DYER VENT COVER PROVIDE WATER — SPIGOT AT THIS LOCATION MARYAN N THOMPSON NEW METAL Pld€ FOR BURNING STOVE. ARCHITECTS WOOD PROVIDE BRACING AS REO. GENERAL NOTES: 741 Mount Auburn Street Watertown, MA 02472 REPLACE EXISTING • SEE EXTERIOR FIN. SCHEDULE FOR tel: (617) 744-5187 SKYLIGHTS WITH NEW. NEW T.O. ROOF MORE INFORMATION. fax: (617) 491- 3844 SKYLIGHTS TO HIT WITHIN +/�y3.2• • PATCH/ REFINISH ALL EXISTING ®�+u�auvrno'.rso nacenec. EXISTING OPENING. INSTALL SURFACES WHERE DISTURBED. MATCH PER MANUF. INSTRUCTIONS. DETAILS TO EXISTING. TYP. N Q O C 7 O a E E as a O L � O CO T.O. NE 12Y { 114 \ �2� 0Y 1/2" 1 J NEW WD. PANEL DOOR AND WD. SCREEN AT ENTRY. PAINT TO MATCH TRIM COLOR NEW WD. DECK AND BENCH @ ENTRY, SEE EXT. FIN. SCHO. 2'4" DEEP, 18- HIGH WD. BENCH OPEN FOR FIREWOOD STORAGE BELOW. CLOSED SIDED AND BACK. SET (DATE CURRENT SET 70.01.2014 DRAWING TITLE: EXT. ELEVATIONS A2.1 EXTERIOR FINISH SCHEDULE FINISH SUPPLIER/ REMARKS LOCATION KEY MATERIAL ----- — --- --- TO MATCH EXISTING WEATHER TO GREY WD. SIDING CEDAR 1x4" HARDWOOD, SO. EDGE, PROVIDE SILL PAINTED COLOR TBD, SEMIGLOSS FINISH WINDOW CASING EXTENSION TO MATCH EXISTING —-------'—"— — PAINTED COLOR TBD, SEMIGLOSS FINISH DOOR CASING ix4' HARDWOOD SQ. EDGE. - . --"_-"— EXTERIOR WALL WD. TRIM/ CORNER PAINT GRADE HARDWOO, VARIOUS WIDTHS PAINTED BOARDS EXPOSED CONCRETE -- — — -_-'. METAL DRYER VENT ! STAINLESS STEEL �, COVER ... .....— ."___....--...—..." --- — - - - ____. REPLACE ENTIRE ROOF WITH MATCH EXISTING WHITE CEDAR SHINGLE ROOFING WEATHER TO GREY NEW SHINGLES ROOF PAINT GRADE CEDAR ALL NEW FASCIA PAINTED SEE DETAIL WD FASCIA —. — -- ..._— — —_ PAINTED ALL TIES TO BE GALV METAL GUTTER MATCH EXISTING — ROOF - PAINTED ALL TIES TO BE GALV. S.S. ii, METAL DOWNSPOUT MATCH EXISTING METAL FLASHING ZT ALLOY COPPER/ FREEDOM GREY EXPOSED VENT PIPE METAL (NO PVC) ! EXPOSED RAFTERS'. AS SPECIFIED IN STRUCTURAL DRAWINGS •-- --- - SS SCREWS MARINE GRADE WD. DECKING ix4 MAHOGANY DECKING W/ Ya' GAP WEATHER TO GREY TYPE 31fi WESTERN RED CEDAR AS ADD ALT. ON DECK WD. FASCIA Q DECK VARIOUS WIDTH MAHOGANY WEATHER TO GREY SEE DETAIL WD POST Q SCREEN 4x4 WESTERN RED CEDAR -- WEATHER TO GREY EXTERIOR DECK �- - ix2 WESTERN RED CEDAR WEATHER TO GREY WD.CAP SCREWS Q DECKING COUNTERSUNK MARINE GRADE STAINLESS STEEL NAILS MARINE GRADE STAINLESS STEEL iz4 MAHOGANY DECKINGW/Y'GAP WEATHER TO GREY TREAD WOOD STAIR RISER FULL WIDTH MAHOGANY WEATHER TO GREY �_--- _ WD. TRIM Q OPEN VERTICAL tz4 WESTERN RED CEDAR WITH Y4' GAP _ WEATHERTO GREY I EDGE OF STAIR .. ....—.-- _......." ___....—.-"—.."_ ix4 MAHOGANY DECKING WIX. GAP WEATHER 70 GREY SEE DETAIL WOOD BENCH WD. TRIM GENERAL NOTE: ALL EXTERIOR NAILS AND SCREWS TO BE MARINE GRADE TYPE 316 STAINLE STEEL -PLUMBING FIXTURES AND EQUIPMENT TBD BY OWNER AND ARCHITECT. PROVIDE ALLOWANCE. DOWNSTAIRS SINK BY OWNER. -HARDWARE: WHITE PORCELAIN KNOBS ON ALL INTERIOR DOORS. ALL EXTERIOR DOOR HARDWARE TO BE REPLACED. PROVIDE ALLOWANCE. TYP. EXT. )E►' TAILS NOT TO SCALE 01 TYP FASCIA DETAIL A DECK w0.DECKNIS AS SPECIFIED WD. CAP AS _SPECIFIED, SLOPED TO DRAIN, WP. WD. SLAT AS SPECIFIED u `—GAP FWD. POST AS SPECIFIED SECUREPOSTTO DECK FRAMING 02. TYP. SCREEN WALL DETAIL AS SPECIFIED) / PT.STAIR 11 L SRiUCTURE FOR STA R 03a. TYP. EXT. STAIR DETAIL 03b TYP TRIM an EXPOSED SIDES OF STAIR MARYANN THOMPSON ARCHITECTS 741 Mount Auburn Street Watertown, MA 02472 tel: (617) 744- 5187 fax: (617) 491- 3844 0 MAa —u— �¢ o� � t C O cL E E 1D cri � Q t to 3 O CM r Z C) �C G a CO3 G co cc 414 sic F_ G CONSULTANTS: STRUCTRAL ENGINEER: COWEN ASSOCIATES 29 Vesta Road Natick, MA 01760 (508)65S-3976 Ray Busses my@cowenassoucom CURRENT ISSUE: SET DATE CURRENTSET 110.01.20141 DRAWING TITLE: EXT. FIN/ DETAILS A2.2 SLIDING PATIO DOORS EXTERIOR WINDOWS 2� Y m PELLA 2117 _-. \ m PELLA 3347 - - - — --_- - - 11 at 11az 1073 35 Y a Y r PELLA 3359 AWNING WINDOW m PELLA 4147 PELLA 4159 n PELLA 3359 105-1 105-2 103-1 103.2 201-1 2015 203-1 104-1 104-2 105-3 103-4 103-5 201-2 201E 2041 1043 104-4 2013 201-7 201.4 201E 107-i 107-2 DOOR SCHEDULE TAG# OPERATION TYPE THICKNESS WIDTH HEIGHT EXT. MAT./ FIN. INT. MAT/ FIN. I CASING D 001-1 D001-2 INSWING SWING INSULATED EXT. PANEL DOOR BULKHEAD EXT. PANEL DOOR TBD 70D TBD TBD TBD TBD _ WOOD/ PAINTED WOOD/ PAINTED .._... WOOD/ PAINTED WOOD/PAINTED .... ....., _...— D103 D110 INSWING IN SWING INSULATED EXT. PANEL DOOR INSULATED EXT. PANEL DOOR TBD _ TBD 3'-0" 3'-0 _ 6-11-VIF 6'•i i' VIF WOOD/PAINTED WOOD/ PAINTED WOOD/PAINTED WOOD[ PAINTED -- D101 IN SWING _ PANEL DOOR 1 s/ 3'-0' 6'E' WOOD/PAINTED WOOD/ PAINTED . D 105 �I SWING PANEL DOOR 1s/ 3-0' 6E WOOD/PAINTED WOOD/PAINTED D 107 SWING PANEL DOOR 1 / -- 2'E" e 6'E' WOOD/PAINTED WOOD/PAINTED -- 5°WD. CASING TO D 106 D 108 SWING SWING ... PANEL DOOR PANEL DOOR 1s/a -. 13/4" 2' } 2'E' 6'-8' WOOD/PAINTED --- WOOD/PAINTED WOOD/PAINTED -- WOOD/PAINTED MATCH EXISTING IN EXISTING HOUSE D203 SWING PANEL DOOR 1%' 2E j 6'-8' WOOD/PAINTED WOOD/PAINTED D204 ! SWING DOOR PANEL DOOR is/ 2E 68 : WOOD/ PAINTED WOOD/PAINTED ------- _. ._-_ — - F$------- EXTERIOR DOOR SCHEDULE (ALL GLASS DOORS BY PELLA) TAG# OPERATION WIDTH HEIGHT EXTERIOR MATJ FIN. INTERIOR MAT/FIN. INSECT SCREEN REMARKS 106-1 3 PANEL SLIDING PATIO (OXO) 81-81 105.2 4 PANEL SLIDING PATIO (OXXO) 1 V-4" V-10' ALUM CLAD WOOD/ PAINTED BY MANUFACTURER 1073 SLIDING PATIO (XO) ...... __ ......... -___.. 108•7 SLIDING PATIO (XO) 6'-0' 1610' TAG# OPERATION W®TH HEIGHT EXTERIOR MATJ FIN. INTERIOR MAT/FIN. INSECT SCREEN _. 10.41 7-T 4'-11' 103-2 103-4 7-9' 4'-11' .__.... 103E 104-1 3'3' 3'-11' IW2 3'-3' T-11' —__ 1C4-3 T-3. ---- 3.-71. ALUM CLAD WOOD/ PAINTED BY MANUFACTURER --s DOUBLE -HUNG 3'-11' 104-4 X-3' 105.1 T-F .105-2 i 31fi' 1053 T-5' 4'-11' X-F T-11' 1073 7-T 3-11' _........ __.... . 108-2 FIXED W. SDL `: T-0' 6'-10' _...._— ALUM CLAD — .... .. _........ : WOOD/ PAINTED BY MANUFACTURE --- - 11a1 _ - ----- -- I T-5' T-i1' 110-2 201-7�� —. 1 201-2 �, 2 9 a 11' 201-3 - DOUBLE-HUNG 29—... -- — ALUM CLAD : WOOD/PAINTED _ BY MANUFACTURER 201E 2'-9" 4'-11' 411' 201E 2-9' ............ .......... 201-7 j 21. 201E 12 203-1 -- AWNING eE' ------- 11' ALUM CLAD/PAINTED WOOD/PAINTED - -' BY MANUFACTURER 204-1 8'E' 2-IV GENERAL NOTES REMARKS VERIFY LOCATION IN FIELD HARDWARE REMARKS 1. ALLWINDOW AND DOOR ELEVATIONS DRAWN 4. ALL OPERABLE WINDOWS AND DOORS TO 5. WINDOW/ DOOR HARDWARE TO BE PROVIDED BY MANUFACTURER, FINISH TO BE BRUSHED _ __TAL PROVIDE SUBMITTAL _ PROVIDE SUBMITTAL FROM THE EXTERIOR UNLESS OTHERWISE AVE UFACTURER SUPPLIED ME INSECT SCREENS. PROVIDE SUBMITTALS ON S.S. OR SIMILAR. PROVIDE SUBMITTALS ON _...... _..... __ .--- - ._ NOTED. OPTIONS. TRIM HARDWARE FOR APPROVAL. PROVIDE SUBMITTAL PROVIDE SU614171'AL 2- CONTRACTOR TO VERIFY ALL DIMENSIONS INCONTRACTOR DOOR PANEL TO BE 6. TO PROVIDE SHOP DRAWINGS PROVIDE SUBMITTAL INCLUDE INSPECT SCREEN FpOpRSEFORE ORDERING WINDOWS AND WOOD SCREEN. EXCEPTION FRONT OR ALL EXTERIOR WIN OWS AND DOORS TO ___. ....... -- ----- ARCHITECTS APPROVAL BEFORE ORDER. --- PROVIDE SUBMITTAL INCLUDE INSPECT SCREEN 3. ALL GLASS TO BE LOW-E, INSULATED, ARGON 7. GC TO PROVIDE PLYWOOD HURRICANE __ _ PROVIDE SUBMITTAL FOR FILLED, W/ MANDATORY U VALUE OF .30 AND PANELS FOR ALL NEW AND EXISTING ENTRY DOOR HARDWARE—, -'; SHGC OF .6. WINDOWS/ DOORS @ MAIN HOUSE. PASSAGE HARDWARE, MATCH KNOBS TO EXISTING IN HOUSE MATCH EXISTING DETAILS/ FINISH AS MUCH AS POSSIBLE GENERAL NOTE: 1. PROVIDE SUBMITTAL ON DOOR HARDWARE TO OWNER BEFORE PURCHASE. 2. VIF. ALL DIMENSIONS IN FIELD BEFORE ORDERING DOORS. --- MARYANm THOM ftON ARCHITECTS 741 Mount Nib— Street Watertown, W 02472 tel: (617) 744-5187 fax: (617) 491- 3844 C MnavnNHn+ar..ounacnM F TANTS: AL ENGINEER: SSOCIATESoad01760 3976 ernassoc.com I REVISIONS: I CURRENT ISSUE: SET DATE CURRENT SET 10.01.2014 DRAWING TITLE: WIN.I DOOR SCHD A3.0 I _.r CEILING TO MATCH EXISTING BED-02 ..._. ._ GYP J PROVIDE BULKHEAD TO BASEMENT. SIZE TO FIT. PROVIDE SUBMITTAL BASEBOAROTO —, BASEMENT MATCH EXISTING, 001 TYP. i� ' - CEILING TO MATCH EXISTING, TYP. 1 SECTION 01 SCALE: 1l4"=1'-0" f- Iz to c. L� T.O. ROOF'. G cm to la f- CONSULTANTS: O. NEW ROOF 12� .81/4 STRUCTRAL ENGINEER: COWEN ASSOCIATES 10•V 3 1Y2• 29 Vesta Road Natick MA W760 (508)655-3976 Ray Busse, rayQoDwenaswo-m 01, 5' 10' 20' REVISIONS: CURRENT ISSUE: SET DATE CURRENTSET 110.01.2014 DRAWING TITLE: BLDG. SECTIONS A4.0 ELECTRICAL LEGEND SYMBOL TYPE /t�A CEILING MOUNTED LIGHT I®e EXT. WALL SCONCE_ WET LOCATION I®G WALL SCONCE I OD WALL MOUNTED UPLIGHT 1H CEILING MOUNTED FIXTURE- WET LOC ,J J BOX FOR FIXTURE BY OWNER ®P WALL MOUNTED PENDANT LIGHT �tLT TRACK LIGHT 4--, g FL V FLOOD LIGHT S LED STRIP LIGHT O. FLOOR OUTLET DUPLEX OUTLET ABOVE COUNTER DUPLEX OUTLET =3D_ SPECIALTY OUTLET -D THERMOSTAT JS JAMB SWITCH N/CABLE/DATA DF EXHAUST FAN o NEXT CEILING FAN UNMARKED: INTERIOR EXT: EXTERIOR SEE ELECTRICAL SCHEDULE FOR GENERALNOTES RELOCATE EXISTING ELEC. METER LOCATE NEAR POLE MARYANN THOMPSON ARCHITECTS 741 Mount Aubu n Street Watoni , MA 02472 tel: (617) 744- 5187 fax:(617)491-3844 C" tD O �G C _ O O a E E 1a 7 p N 3 O [h /n V CONSULTANTS: STRUCTRALENGINEER COWEN ASSOCIATES 29 Vesta Road Natick, MA 01760 (508)655-3976 Ray Busser ray@cowenaasoc.com I REVISIONS: CURRENT ISSUE: SET DATE CURRENT SET 110.01.2014 DRAWING TITLE: ELECTRICAL PROPOSED ELECTRICAL 0 11 5' 10' 20' 01 FIRST FLOOR 0 E1.0 SCALE: 1 /8"=V-0" ELECTRICAL LEGEND SYMBOL TYPE �A CEILING MOUNTED LIGHT i®e EXT. WALL SCONCE_ WET LOCATION i®Q WALL SCONCE HD WALL MOUNTED UPLIGHT 8H CEILING MOUNTED FIXTURE - WET LOC �J J BOX FOR FIXTURE BY OWNER �P WALL MOUNTED PENDANT LIGHT y�T TRACK LIGHT 4 FLOOD LIGHT S LED STRIP LIGHT O. FLOOR OUTLET =3� DUPLEX OUTLET ABOVE COUNTER DUPLEX OUTLET ::Q- SPECIALTY OUTLET THERMOSTAT JS JAMB SWITCH TV/CABLE/DATA (9F EXHAUST FAN XT XE CEILING FAN UNMARKED: INTERIOR EXT: EXTERIOR SEE ELECTRICAL SCHEDULE FOR GENERALNOTES GENERAL NOTES • DRAWINGS ARE INTENDED TO CONVEY DESIGN INTENT ONLY. CONTRACTOR PRICE SHALL INCLUDE ALL WORK AND EQUIPMENT NECESSARY FOR FULLY FUNCTIONAL SYSTEM. • PROVIDE DIMMER SWITCHES FOR: - TRACK LIGHTING IN KITCHEN - ALL WEDGE UPLIGHTS - ALL CEILING SCONCES • DIMMERS TO BE SIZED ACCORDING TO MANUFACTURER'S REQUIREMENTS, AND SIZED FOR WATTAGE OF CONNECTED FIXTURES. • GFI CIRCUITS FOR ALL BATHROOMS, KITCHEN, LAUNDRY, VANITY, EXTERIOR, GARAGE LEVEL, AND OTHER WET/DAMP LOCATIONS. • PROVIDE ALL UTILITY TRENCHING AND CONNECTIONS REQ. TO "MAKE LIVE' INCLUDING COORDINATION Wl UTILITY COMPANIES. • CABLE/TEUDATA @ LIVING ROOM -ALL HOME RUN TO CENTRAL LOCATION. • GC TO COORDINATE W/ OWNER DURING FRAMING FOR CABLEITEL/DATA LOCATIONS. • DETERMINE EXACT LOCATION OF FIXTURES/ FAN ON SITE W/ OWNER/ ARCHITECT • ALL MECHANICAL AND APPLIANCES SHALL BE COORDINATED AND MADE LIVE AS REQ. • PROVIDE ALL SMOKE DETECTORS AS REQUIRED BY CODE, INCLUDING BEDROOM LOCATIONS, HALL LOCATIONS, STAIR LOCATIONS, AND BASEMENT. PROVIDE SUBMITTALS AND VERIFY ALL LOCATIONS IN FIELD WITH ARCHITECT. • PROVIDE ALL CARBON MONOXIDE DETECTORS AS REQUIRED BY CODE, INCLUDING ONE OUTSIDE OF MASTER BEDROOM AND IN HALL 201, AND IN BASEMENT. PROVIDE SUBMITTALS AND VERIFY ALL LOCATIONS IN FIELD WITH ARCHITECT. • PROVIDE HEAT DETECTOR AS REQUIRED BY CODE. • PROVIDE THE FOLLOWING COVERS AND PLATES: a. ALL PLATES TO BE WHITE EXCEPT WHERE LOCATED ON MIRROR OR WOOD W. CLEAR FINISH SURFACES TO BE BRUSHED NICKEL OR SIMILAR. PROVIDE SUBMITTAL FOR ARCHITECTS APPROVAL. b. FLOOR OUTLET BOXES TO BE CONCEALED WITH RECESSED HOUSING IN SILVER METAL COLOR. c. ALL OUTLETS TO BE ORIENTED HORIZONTALLY UNLESS OTHERWISE NOTED. d. ALL SWITCHES TO BE TOGGLE SWITCH e. IT IS THE ARCHITECT'S INTENTION THAT ALL FIXTURES ALIGN WHERE DRAWN IN A LINE, AND THAT THEY ARE NEATLY LAID OUT PARALLEL OR PERPENDICULAR TO ADJACENT WALLS. I. REVIEW LOCATION OF ALL REQUIRED TRANSFORMERS WITH ARCHITECT PRIOR TO INSTALLATION. g. USE REMOTE TRANSFORMERS AS RECOMMENDED BY FIXTURE MANUFACTURERS, AS REQ. NO SUBSTITUTIONS. h. LOCATE OUTLETS AS REQUIRED BY CODE AS WELL AS IN LOCATIONS INDICATED ON DRAWINGS. ALL OUTLET AND SWITCH LOCATIONS TO BE APPROVED BY ARCHITECT IN FIELD BEFORE INSTALLATION. 1. OULET EVERY 10' IN BASEMENT. INCLUDE 5 FLUORESCENT STRIP LIGHTS IN BASEMENT CEILING. 01 PROPOSED SECOND FLOOR ELECTRICAL SCALE: 1/4"=1'-0" MARYANN THOMPSON ARCHITECTS 741 Mount Aubum Street Watertvlun, MA 02472 tal: (617) 744- 5187 fax: (617)491-3844 o Mnavnnmr Tnouasounacx— N Q O C 7 O a E E coo m 0 L L N 7 O co C/) Z cm Cd G Q x _y m O co cc Q H (CONSULTANTS: I STRUCTRAL ENGINEER COWEN ASSOCIATES 29 Vesta Road Natick, MA 01760 (508) 655-3976 Ray Buser .y@—nassoc.com CONTRACTOR: I REVISIONS: I CURRENT ISSUE: SET DATE CURRENTSET 10.01.2014 DRAWING TITLE: ELECTRICAL E1.1 R.D. KING'sTUDS RED. STRAP REWIRED - No 0 _0" 2X_ YFS .. � � OI'tiDN: IIVY YLYW,UUu w� yenicR THIRD OF BAND JOIST- TYPICAL WIND TIE DOWN DETAILS . WIND SPEED -'110 - 120 MPH EXIST WALL CONST FIRST FLOOR (PT) SILL {2)-T TA. SUa FLOOR: �2x6 48 o1cAa. --- T.O. WALL \:EXIST FLOOR CONST (2)- TOP 5 CONt . 10" FOUNDATION- WALL^` -REFER TO PLAN FOR COLUMN: SIZE AND ORIENTATION a 0 MID -HEIGHT. d OF WALL BASE PLATE W/ ANCHOR HND 4 5/6" CIA. - -SET ON 1//4'LEVEL PL AND #5 D ?a" O/C �`"� - f( 3/4 ORDUT j — REFER TO PLAN FOR SLAB - VERTICAL - \ l\ ISOLATION JOINT DEPTH AND REINFORCING C .— �6' (MIN.) COMP,. 15 DOWELS @ 24" 0/C F4" SLAB -CFI -GRADE W/ _ _ j CRL" STONE / . REINFORCING(TYP) REINFORCING(M) EINFO CING(e T.O. SlA4. vs J' 7a _— - .:: REFER TO PLAN 1 UNDISTURBED SOIL TYPICAL FOUNOAYI WALL "SECTION. TYPICAL INTERIOR COLUMN Nat-io-�SSca1; o -„o- ca e dui ul --us r SHEAR WALL SCHEDULE SHEAR WALL SHEATHING / NAILING 15/32' PLI;WOOD SHEATHING W/ 10d NAILS Q 9 4' O/C AT EDGES AND O 12' 0/C FIELD BLOCKED SHEATHING ONE SIDE ONLY CORNER SPACING 7 ¢ EVERY OTHER HORZ. aAR '-D-I -0- #5.0 12- O/C L 2" CLR CONST.. KEY :INTERSECTION. CONSTRUCTION JOINT CONCRETE WALL DETAILS.. Not-to-Scole: CONSULTING STRUCTURAL ENGINEERS. 29 VESTA ROAD NATICK, NASSACHU9E7TS 91m TeNpfwne (508)653-3976 Fa661de (509) 655-4264 Ema[fffld@ wm Web Sde: wwwJmwe06sv wm STRUCTRA. RNGRJF.BE COWEN ASSOCIATES 28 V.W Road Ratak NA 01760 (108)656A976 - Ray Baser i ,ayEg�wenaesxaam . CONTRACTOR: i. REVISIDNS: i STRUCTURAL Sol 4Ax Pm ARW -.:. . - .. - nn.UtWM Cn'f-' YDUATUNS W1 %9 A.e *Ile d4w StHR vFrz - : - - SHEAR- 3FE SNEHt WALL o .• CYl1(4iFi-r-� � k - . . 9oiWUtE: u f I✓:e -I Ile I - = _- II!I:!I - - 1 (11 i ilifl, _ d N _b _... .... I ICI GR a 5 .al :_ uF➢^� -}: 1- : � - _ � I I �'• 6NEAR WALL - . _ - - - . , . ���YEPo� - - . - a - ipN k n1N NHL W : � iWiM's TV! ImXEW 41E6 PIFE W �PoAiS .iB�otE a ti a - - - sn.- m MI z-e" : yff sm x naWn. _ - oi PROPOSED FOUNDATION/ FIRST FLR. FRAMING' ,.:... _ -- _ r 2dN PbST ON _..i k. NEW 1 t pp Nf PS C wsbN4�WALL f: AAA _. i `. ` _La PoST. a 02 PROPOSED SECOND FLOOR FRAMING PLAN SCALE Ire -I V —1 nAE. vuwoop srFAn+ric FAS2n1/a`.i�M Yl & 6ti O.C... WIeD NPIS czJUeo RNUaB on IPaL1Gy5 a. swPsan SLOP�.+leacER TYPICAL ROOF LEDGER DETAIL MOTT{}�AIE. C}3 PROPOSED ROOF FRAMING PLAN SCAM 3!8 -V—W MARYANN rkompsm ARCHITECTS 7416Am At&-Str Waftftw MA07A72 b[16171741-6187 fax: �617J491 38i4 -. P Awwux,NxfawAxwteas A Q � =Q a E Etu �a cop FMUCFNAL ENG it .__ ......... ........I COVOENASSOCYATES 28:VWaRmd NReck MA01760. (608) 655-39M j Ray 80aeet ray�mwenessocmm ' CONTRACTOR: - REVQSIONS. CURRENT ISSUE: AE7 oaTF -. _ l:1MRENL SET iDA1,201A. MOMS mI E STRUCrUPAL 0 i' 5' tU 2ff S1.0