BP-93309r . m. ... . ..... E t ni WK MW F WEI Suite 200E 30 Mon 280 Elm Street, Sou WWW.dska TWO STOREY BUILDING CONSTRUCTION MANAGER m BOUCHER & ASSOCIATES, INC. RIVERMOOR ENGINEERING, LLC CIVIL ENGINEER STRUCTURAL ENGINEER 0 ...ate ..,....,_._.. - .:.. �\SSEREDAgCH tsz aM+ss4 W U zoo Wog Q OC N O Q W � � 2 D 2 O W NSCC G Q a w U) 0-o ARCHITECTURAL SYMBOLS SECTION DESIGNATORS LINE TYPES SIM CONTRACT LIMIT 1 SIM 1 -AT-fr A101 BUILDING WALL A101 - - - - - - - - - - SECTION SECTION 71� SECTION IDENTIFICATION -21-' SHEET NO. WHERE DRAWN m ELEV. SECON�p DETAIL / SECTION - - - - - - SIM 1 ... ,. . :::... .. ..:. . A101 DETAIL OR SECTION IDENTIFICATION SHEET NO. WHERE DETAIL OR SECTION IS DRAWN ` OF AREA OF �- 1 A10 BUILDING ELEVATION _________________________________ 1 ELEVATION A101 SHEET NO. WHERE ROOM ROOM ROOM ELEVATION U 1--MiMin 150 SF - room N ELEVATION SHEET NUMBER WHERE DRAWN A3111 (NO ARROW MEANS THE ELEVATION IS NOT SHOWN) DOOR MATERIALS CONTRACT LIMIT LINE ACOUSTIC TILE OR PANEL MATCHLINE (LARGE SCALE) NEW OR FINISHED CONTOURS O ACUSTIC TILE OR PANEL EXISTINGCONTOURS FINISH FLOOR ELEVATION N PLANS, ELEVATIONS, ALUMINU AND SECTIONS A CENTERLINE NEW CONSTRUCTION BRICK (common or face) EXISTING TO REMAIN EXISTING TO BE DEMOLISHED CARPET (LARGE SCALE) EXISTING DOOR TO REMAIN EARTH EXISTING DOOR &FRAME TO BE DEMOLISHED CONTINUOUS AIR BARRIER GRAVEL GROUT &MORTAR GYPSUM BOARD, PLASTER, SAND the door number matches the room hinge entered number (ie. C 101). the second door latch entering a Within the COLUMN room is denoted 101A, and IkeMse the third _ door is denoted 101 B, 3.1 I and so on. DOOR ELEVATION LO I sidelight (part of door assembly) f `! REVISION 22 (CLOUD AROUND ALL REVISIONS) bonowed liight(BL)(sequentwlnumber) 53A1 L partition type (see dwg ABBREVIATIONS 4 At Eq. Equal O.C. On Center (s) A.C. A'r Conditioning Equip. Equipment O.H. Overhead A.F.F. Above Finished Floor Ex Existing O.P. Overflow Pipe Acoust. Acoustic, Acoustical Exh. Exhaust Op. Sim. Opposite Similar Adj. Adjustable Exp. Jt Expansion Joint Opp Hnd. Opposite Hand Alum. Aluminum Ed. Exterior P.T. Pressure Treated Anod. Anodized F.H. Full Height P1. Plate Approx. Approximate F.O.B. Face of Block / Brick Plain. Plastic Laminated Arch. Architect(urd) F.O.C. Face of Convector Plywd. Plywood Aux. Auxiliary F.O.W. Face of Wall Ptd. Painted Bd. Board F.P. Fireproof, Freproofing R. Radius Bldg. Building F.R. fie Rated R.D. Roof Drain Blk. Block (s) Fd. Floor Drain/ Fred Dimension R.O. Rough Opening Blkg. Blocking Fdtn. Foundation Rod. Radius Bar. Bottom Fin. Finish, Finished Ref./REfl. Reflected C.B. Chalk Board Fix. Fixture Reinf. Reinforce (d) ring) C.D. Ceiling Diffuser FL/Fir. Floor Req'd. Required C.H. Cabinet Heater FBhg. Flashing Rm. Room C.J. Control Joint Fig. Footing S. South C.L. Center Line G.C. General Contractor Sch. Schedule C.O. Cased Opening Ga. Gauge Sim. Simla to C.R. Ceiling Register Galy. Galvanized Spec. Specification C.W. Cold Water GI. Glass Spr. Sprinkler Cab. Cabinet Gr. Grade St./Sfi. Stainless Steel Cem. Cement GWB./GYP TO. Gypsum Wall Board Stl. Steel Clg. Ceiling H.C. Handicapped Star. Storage Clcs, CL Closet H.M. Hollow Metal Str. Structural, Structwe Ck Cleo H.VA.C. Heat, Vent., & Air Cond. Susp. Suspended CMU Concrete Masony Unit Ha. Horizontal T.G. Tempered Glass Col. Column Ht. Height T.O.C. Top of Concrete Coo. Concrete Incl. Include (d) ring) T.O.S. Top of Steel Comet. Construction Insul. Insulation Tel. Telephone Cont. Continuous Int. Interior Temp. Tempered Corr. Corridor Jan. CI./J.C. Janitors Closet Thk. Thickness D./DN. Doom it Joint Toil. Toilet D.F. Drinking Fountain Lam Laminate Trans. Transformer D.M.B. Dry Maker Board Lay. Lavatory Typ. Typical Det. Detail Lbs. Pounds U. Up Dia. Diameter Ldr. Leader U.L Underwriters Laboratories Diag. Diagonal M.O. Masonry Opening U.N.O. Unless Noted Othervrise Dim. Dimension Mail. Material V.I.F. Verify in Field Dfsp. Dispenser Max. Maximum VCT Vinyl Composition Tile DP. Dampproofing Mech. Mechanical Vert. Vertical Dag. DraW ng Mfg. Manufacturer Vest. Vestibule E. East Min. Minimum W. West E.O.D. Edge of (Roof) Deck MB. Metal W.C. Water Closet E.O.S. Edge of Slab N. North W.W.F. Welded Wire Fabric Ea. Each N.I.C. Not In Contract W/,W/O With, Without El. Elevation (Feet & Inches) N.T.S. Not To Scale WD Wood Elect. Elecric, Electrical No. a # Number Elev. Elevator Nom. Nominal INSULATION (LOOSE OR BATTING) INSULATION (BOARD) INSULATION (SPRAY) CONCRET CONCRETE MASONRY UNIT PARTICLE BOARD PRE -MOLDED FILLER ROCK STEEL (LARGE SCALE) -- PLYWOOD (LARGE SCALE) - WOOD (FINISHED) WOOD (ENGINEERED LUMBER) WOOD (ROUGH FRAMING, CONTINUOUS MEMBERS) WOOD (BLOCKING, INTERMITTENT MEMBERS) " NEW CONSTRUCTION/ STRUCTURE GENERAL PROJECT NOTES: 1. ALL WORK PERFORMED, INCLUDING MATERIALS FURNISHED,WORKMANSHIP, AND MEANS AND METHODS OF CONSTRUCTION SHALL CONFPRM TO THE APPLICABLE AND LATEST REQUIREMENTS OF THE MASSACHUSETTS STATE BUILDING CODE AND THE APPLICABLE C'TY OR TOWNSHIP AND GENERAL CONDITIONS PER OWNER/CONTRACTOR AGREEMENT DOCUMENTS. 2. BEFORE COMMENCING WORK, THE CONTRACTOR SHALL FILE ALL REQUIRED CERTIFICATES OF INSURANCE WITH THE OWNER AND THE DEPARTMENT OF BUILDINGS, OBTAIN ALL REQUIRED PERMITS, AND PAY ALL FEES REQUIRED BY THE GOVERNING AGENCIES AND BE RESPONSIBLE FOR OBTAINING AND COORDINATING ALL PERMITS AND ASSOCIATED FEES. 3. THE CONTRACTOR SHALL VISIT THE PROJECT SITE AND VERIFY THAT ALL EXISTING CONDITIONS AGREE WITH THE INFORMATION SHOWN ON THE DRAWINGS. ANY CONFLICTS, OMISSIONS OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECTS FOR RESOLUTIONS PRIOR TO COMMENCEMENT OF ANY WORK. NO ALLOWANCES WILL SUBSEQUENTLY BE MADE ON B[HALF OF THE ARCHITECT FOR ANY ADDITIONAL EXPENSES WHICH ARE INCURRED DUE TO NEGLECT OR WHICH COULD HAVE BEEN REASONABLE FORESEEN BY PRIOR INSPECTION OF EXISTING CONDITIONS. 4. PRIOR TO COMMENCING WORK, ORDERING OF MATERIALS AND SHOP FABRICATION OF ANY MATERIALS, THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AS INDICATED ON THE DRAWINGS AND SHALL REPORT ANY DISCREPANCIES TO THE ARCHITECT FOR RESOLUTION. S. DRAWINGS INDICATE LOCATION, DIMENSIONS. REFERENCE AND TYPICAL DETAILS FOR CONSTRUCTION. MINOR DETAILS NOT USUALLY SHOWN OR SPECIFIED, BUT NECESSARY FOR PROPER CONSTRUCTION OF ANY PART OF THE WORK SHALL BE INCLUDED AS IF THEY WHERE INDICATED IN THE DRAWINGS. FOR CONDITIONS) NOT ILLUSTRATED, NOTIFY ARCHITECT FOR CLARIFICATION AND/OR SIMILAR DETAIL. 6. WHEN THE SCOPE OF WORK INCLUDES ALTERATION TO EXISTING FACILITIES. WORK WHICH IS OBVIOUSLY REQUIRED TO BE PERFORMED OR IS OBVIOUSLY NEEDED TO PROVIDE A COMPLETE AND FINISHED PRODUCT WITHIN THE SCOPE OF WORK BUT WHICH IS NOT SPECIFICALLY INCLUDED ON THE CONTRACT DOCUMENTS, SHALL BE PERFORMED BY THE CONTRACTOR AND BE INCLUDED ON THE BID. CONTRACTOR TO INSPECT AT TIME OF DELIVERY ALL FIXTURES PROVIDED BY OWNER TO INSURE PROPER QUANTITY, THAT ITEMS ARE DEFECT FREE AND MATCH INVOICE. CONTRACTOR TO BE RESPONSIBLE FOR INSTALLATION, WHICH MAY INCLUDE WALL BLOCKING, SHIMMING,. ETC. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE ALL ITEMS SUPPLIED BY THE OWNER'S VENDORS AND TO VERIFY THAT ALL MATERIALS RECEIVED ARE IN ACCORDANCE WITH THE SPECIFICATIONS, HEREIN, UNLESS OTHERWISE NOTED. ANY DAMAGED ITEMS OR DISCREPANCIES BETWEEN MATERIALS SPECIFIED AND MATERIALS SHIPPED SHALL BE REPORTED TO THE ARCHITECT PROMPTLY. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL INSTALLATIONS, CONDITIONS OF MATERIALS AND FINISHES WITHIN THE PROPOSED CONSTRUCTION AREA AND ALL ADJOINING PROPERTIES AFFECTED BY CONTRACTORS OPERATIONS. THE CONTRACTOR SHALL PROVIDE ADEQUATE SHORING AND BRACING FOR STRUCTURAL OR REMOVAL TASKS. THE CONTRACTOR SHALL HAVE SOLE RESPONSIBILITY FOR ANY DAMAGE OR INJURIES CAUSED BY OR DURING THE EXECUTION OF THE WORK. ANY EXISTING MATERIALS AT THE CONTRACTOR'S OWN COSTS, TIME AND EXPENSES. 8. THE CONTRACTOR SHALL DO ALL CUTTING,CHASING, CORE DRILLING, PATCHING AND REPAIRING AS REQUIRED TO PERFORM ALL THE WORK THAT MAY BE INDICATED ON THE DRAWINGS, AND ALL OTHER WORK THAT MAY BE REQUIRED TO COMPLETE THE JOB. PATCHING SHALL MATCH ADJACENT SYSTEMS, MATERIALS AND FINISHES, UNLESS OTHERWISE NOTED. 9. CONTRACTOR SHALL EMPLOY ADEQUATE NUMBER OF SKILLED WORKMEN WHO ARE THOROUGHLY TRAINED AND EXPERIENCED IN THE NECESSARY CRAFTS AND WHO ARE COMPLETELY FAMILIAR WITH THE SPECIFIED REQUIREMENTS AND THE METHODS NEEDED FOR PROPER PERFORMANCE OF THE WORK AND SHALL CARRY ALL REQUIRED CERTIFICATIONS AND ACCREDITATIONS REQUIRED TO PERFORM HIS/HER WORK. ALL WORK SHALL BE PERFORMED BY DULY LICENSED AND INSURED PROFESSIONALS AND AS REQUIRED BY STATE AND LOCAL GOVERNMENTS FOR REACH APPLICABLE TRADE, (PLUMBING, ELECTRICAL, MECHANICAL, ETC) WHO SHALL ARRANGE FOR AND OBTAIN REQUIRED INSPECTIONS AND SIGN - OFFS. 70. THESE DRAWINGS ARE DIVIDED INTO SECTIONS FOR CONVENIENCE ONLY. CONTRACTOR, SUB-CONTRACTORSNENDORS AND MATERIAL SUPPLIERS SHALL REFER TO ALL RELEVANT SECTIONS IN BIDDING AND PERFORMING THEIR WORK AND SHALL BE RESPONSIBLE FOR ALL ASPECTS OF THEIR WORK REGARDLESS OF WHERE THE INFORMATION OCCURS ON THE DRAWINGS, OR IN THE DRAWING SET. it. CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE WORK OF ALL TRADES AND SHALL PROVIDE ALL DIMENSIONS REQUIRED FOR OTHER TRADES. GENERAL CONTRACTOR AND SUB -CONTRACTORS SHALL BE RESPONSIBLE FOR COORDINATION OF THEIR WORK WITH THE WORK OF OTHERS AND SHALL VERIFY THAT ANY WORK RELATING TO THEM, WHICH MUST BE PROVIDED BY OTHERS, HAS BEEN COMPLETED AND IS ADEQUATE PRIOR TO COMMENCING WORK. 12. CONTRACTOR SHALL PROVIDE STRUCTURAL BACKING/BLOCKING FOR ALL WALL MOUNTED FIXTURES, FINISHES AND EQUIPMENT. AND FOR ALL HANGING FIXTURES, BLINDS, CLOUDS, TRACKS, ETC. 13. CONTRACTOR SHALL INSTALL ALL MATERIALS AND EQUIPMENT AS PER THE MANUFACTURER'S WRITTEN INSTRUCTIONS AND/OR RECOMMENDATIONS AND SHALL PROVIDE ANY AND ALL PARTS, ACCESSORIES, EQUIPMENT, PIECES, WIRING, ETC AS RECOMMENDED AS NEEDS FOR A FULL FUNCTIONING SYSTEM. 14. CONTRACTOR SHALL, AT ALL TIMES DURING THE COURSE OF THE CONSTRUCTION, KEEP ADJOINING PREMISES, INCLUDING STREETS AND OTHER AREAS ASSIGNED TO OR USED BY THE CONTRACTOR. FREE FROM ACCUMULATION OF WASTE MATERIALS AND RUBBISH CAUSED BY CONTRACTORS EMPLOYEES, SUB -CONTRACTORS, VENDORS OR THEIR WORK. MINIMUM 75% OF ALL CONSTRUCTION WASTE PRE AND DURING CONSTRUCTION AND INCLUDING ANY/ALL DEMOLITION THAT IS NOT SALVAGED. SHALL BE RECYCLED. IN ACCORDANCE TO ALL STATE LOCAL AND ENVIRONMENTAL POLICIES. 15. CONTRACTOR SHALL ASSIST IN DELIVERY AND STORAGE OF OWNER SUPPLIED ITEMS, AND DISPOSE OF ANY RESULTING TRASH. 16. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL TRADES PRIOR TO INSTALLATION; SHALL SUBMIT ACTUAL SAMPLES OF MATERIALS AND COLOR/FINISHES FOR ARCHITECT APPROVAL ON ANY DEVIATION/SUBSTITUTION FROM THE SPECIFICATION AND CONTRACT DRAWINGS; SHALL PROVIDE, COORDINATE AND ISSUE PRODUCT SUBMITTALS ON ALL OR MOST PROJECT PRODUCTS TO ARCHITECT FOR APPROVAL. 17. CONTRACTOR SHALL PROVIDE AND BE RESPONSIBLE FOR PROJECT CLOSEOUT, PRIOR TO FINAL PAYMENT, INCORPORATE ALL STANDARD GUARANTIES AND WARRANTEES AND ORIGINALS OF ALL APPLICABLE CERTIFICATE OF TESTING, INSPECTION, TEMPORARY FINAL CERTIFICATE OF OCCUPANCY, COORDINATE WITH OWNER. 18. CONTRACTOR TO VERIFY ALL QUANTITIES IN THE CONTRACT DOCUMENTS. ANY QUANTITIES, AREAS (PERIMETER, GROSS, NET, F, YARDS, ETC) AND TAKE -OFFS ARE THE RESPONSIBILITY OF THE CONTRACTOR, INCLUDING THE AREAS AND QUANTITIES NOTED IN THIS CONTRACT SET AND ASSOCIATED DOCUMENTS (WHICH SHALL BE OWNED AND VERIFIED BY THE CONTRACTOR). 19. CLEANING: CONTRACTOR SHALL BE RESPONSIBLE FOR A THOROUGH, PROFESSIONAL CLEANING OF THE ENTIRE FACILITY INSIDE AND OUT. PRIOR TO OWNER TAKEOVER DATE. ALL EXPOSED HORIZONTAL AND VERTICAL SURFACES INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING, MUST BE WIPED CLEAN AND FREE OF DUST AND DEBRIS; WALLS, EXPOSED STRUCTURAL MEMBERS, STAIRS AND RAILINGS, CABINETRY, ALL FLOOR AND COUNTERTOPS, FIXTURES, GLASS SILLS/JAMBS, CASEBOOKS, FINISHES, ETC. ALL FLOORS MOPED CLEAN, CARPETING VACUUMED, TILES CLEANED AND LAWN MOWED (IF APPLICABLE) 20. CONTRACTOR TO PROVIDE COPIES OF AS -BUILT INFORMATION, OPERATION AND MAINTENANCE (O&M) MANUALS INCLUDING ALL PRODUCT GUARANTIES AND WARRANTIES. 21. GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL PROVIDE PRODUCT TRAINING ON ALL INSTALLED SYSTEMS TO OWNER OR FACILITIES GROUP REPRESENTATIVES. 22. CONTRACTOR TO KEEP A SET OF THE MOST CURRENT DRAWINGS, SKETCHES AND RFTS ON SITE AT ALL TIMES. 23. DO NOT SCALE DRAWINGS- WRITTEN DIMENSIONS TAKE PRECEDENT OVER GRAPHIC REPRESENTATION. DETAIL DIMENSIONS TAKE PRECEDENT OVER LARGER PLAN/SECTIONAL DIMENSIONS. ANY INCONSISTENCY AND/OR CONFLICTING DIMENSIONS SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION IMMEDIATELY FOR CLARIFICATION. CONTRACTOR SHALL NOT AT ANY TIME SCALE DIMENSIONS OR ELEMENTS OFF DRAWINGS. PLEASE CONTACT ARCHITECT FOR DIMENSION IN QUESTION. 24. IF THERE ARE ANY CONFLICTING INFORMATION OR NOTES ON THE DRAWINGS. THEN THE CONSULTANT'S DRAWINGS SHALL SUPERSEDE/GOVERN. DETAIL DRAWINGS AND WRITTEN SPECIFICATIONS SHALL SUPERSEDE/GOVERN OVER LARGER SCALED DRAWINGS. CONTACT ARCHITECT PROMPTLY OF ANY SAID CONFLICTS If FURTHER CLARIFICATIONS WARRANTED. 25. ALL WOOD (TRIM, FLAT STOCK & PROFILES, CAPS, SIDING ETC.) SHALL BE FULLY PRIMED (ALL SURFACES), ESPECIALLY END GRAIN. THIS SHALL INCLUDE ALL FACES THAT HAVE BEEN CUT, TRIMMED, PLANED, SANDED. FILLED, ETC. FOR INSTALLATION. 26. IF CORNER BOARDS OR ANY OTHER EXTERIOR TRIM ARE PREFRABRICATED ON OR OFF SITEALL SURFACES SHALL BE PRIMED AS NOTED ABOVE. THIS SHALL APPLY TO PRE -CASED AND PRE -MULLED WINDOWS THAT ARRIVE ON SITE READY FOR INSTALLATION. 27. ALL "WALL" FLASHING SHALL BE COPPER AND SHALL BE FULLY INSTALLED PRIOR TO THE INSTALLATION OF'HOME-SLICKER" (SIDEWALL RAINSCREEN MEMBRANE). FLASHING SHALL BE INSTALLED AT ALL WINDOWS, DOORS, WATER TABLES, VENEERS AND AT ANY HORIZONTAL WOOD TRIM (OR SEAMS) WHERE THE TOP IS EXPOSED TO THE WEATHER. 28. CONTRACTOR SHALL INSTALL GRACE"VYCOR"SELF ADHERING FLASHING AT ALL DOORS AND WINDOWS AS PER MANUFACTURERS RECOMMENDATIONS. PLEASE REFER TO THE WEB SITE: WWW.NA.GRACECONSTRUCTION.COM 29. CONTRACTOR SHALL INSTALL"HOMESLICKER' BEHIND ALL WOOD SIDING AS PER MANUFACTURER'S RECOMMENDATIONS. PLEASE REFER TO WEB SITE: W W W.OBDYKE.COM DRAWING LIST GENERAL MC-VERSHEET DRAWING LIST &GENERAL NOTES G002 BIRD'S EYE VIEWS G003 JGROUNDVIEWS SITE PLANS SPI01 SITE CONCEPT PLAN ARCHITECTURAL AI01 1 FIRST FLOOR , A102 ISECONDFLOOR A202 SECOND FLOOR RCP A301 NORTH ELEVATION A302 I EAST ELEVATION A303 ISOUTH ELEVATION REGIONAL LOCUS �tEafD,c9�y O a Z ti ss b PROPOSED PARKER RESIDENCE MISHAUM POINT RD. DARTMOUTH MA 02748 DSK IDewing Schmid Kearns ARCHITECTS ♦ PLANNERS Suite 200E 30 Monument Square Concord, MA 01742 978.371.7500 280 Elm Street South Dartmouth MA 02748 www.dskap.com PERMIT SET AUGUST 16TH 2O19 REVISION TO TITLES: DRAWING LIST & GENERAL NOTES V 0/16/19 CALE As indicated JOBNO. 01863.00 V oo l DATEDRAWN 1 A304 le-(' 2 1 A301 , A402 A401 A402 9'-0' �'_p 9'-0' 5-10' DECK ROUGH ABOVE' 7-8' 3-6' 7-10' 7'-117/8' 17-0' 8'-01/Er 7-10 3'-6' 7-8' M.O. C M.O. 10't 10' - 4' yl 4' - 5' L - 5" DECK ROUGH FRAME ABOVE SONOTUBES PER STRUCT. DWGS. --- --------- UNDER CORNER POSTS OF ENTRY DECK ABOVE CORRUGATED METAL I < 3 WINDOW WELLSTYP. iv b (2 A402 SONOTUBES PER STRUCT. DWGS. a UNDER CORNER POSTS U OF ENTRY DECK ABOVE 1/2" J 22-1I/4 n n 31/2' b N 3I/7 'vw ry w w ..I O UP 071/2' BASEMENT HALL aoa., m 003 �1.{' ;o A = & == - ---- J_ o 2a6 WALL TO _ b HIDE DROP BEAM — ----J -�'+ I i( FACE OF CONCRETE STORAGE ao ® I� Y COLUMNS EVE w } EVERY 6'-0" MAX. ' 1 SUPPORTING 1r v{_ BEARING LINE ABOVE b REC ROOM '{: SEE STRUCTURAL DWGS. 002 { 81THICK CONCRETE 22'-Q"X 18'-0" b..sI WALLS AT BULKHEAD i ...1: W/SITE-BUILT PT STAIR I o Q � n GAP FOR A Q 004 U WASTE -LINE PATH M O it n d i bj - I I I I I SONOTUBES PER STRUCT. DWGS. I UNDER POSTS ABOVE AND -/- EVERY 8'-0' I I L- - - - - - - - - - - - - - - - - - - - - - - 16'-113/4- 6 /8' S'-b Ill 6'-8" 9'-3' 9'-3' 67-0' 44'-01/4' DECK ROUGH FRAME ABOVE 4-B'-0'VIF BULKHEAD NOTE: ALL DIMENSIONS TO FACE OF STUD OR FACE OF FOUNDATION UNLESS NOTED OTHERWISE BASEMENT- BUILDING PLAN \�SERED,iR 7a z,s �3 11, 0, M>56PC' PROPOSED PARKER RESIDENCE MISHAUM POINT RD. DARTMOUTH MA 02748 DSK IDewing Schmid Kearns ARCHnECTS+PLANNERS TITL Suite 200B 30 Monument Square Concord, MA 01742 978.371.7500 280 Elm Street South Dartmouth MA 02748 www.dskap.com PERMIT SET AUGUST 16TH 2O19 REVISION PLANS: BASEMENT PLAN 08/16/19 NO. 01863.D0 'N` I 00 WIN BY JRM ` ` ` . A. \ D. AU � \ / . 'IL / / �[ / (� / ' \ / / |WOOD ~.~ / \ � PROPOSED 9o'& STEPSENTR� DECK / |W PARKER ` ` / / /RESIDENCE / ` ` / / / . / OA - / ' MUDROOM / / / / / / /MISHAUM POINT RD. / DARTMOUTH MA / 02748 � � ---~- / / l � / / � � T / DININGLIVING �W �o| .KITC1L4 ' /ARCHITECTS DSK Dewing Schmid Kearns ' / + PLANNERS / / / l /Suite 200B / / MA 01742 /Concord, �� / ` ' / /280 Elm Street / South Dartmouth 02748 |MA INDOW SEAT T i `-----'_--_-------_—'---' rExw// SET . !REARIDECK AUGUST /mnonv �RA ` / / / / r---�----�------------------------ | | ^----'-------'--'-- —_-------------'— '' ME D���STEPS '/ / ~ ' ' / '' ' ' ~~ ' AREA (FINISHED) BASEMENT FINISH 656 SF 1ST FL FINISH 1785 SF / .-_ NO., DATE, REVISION IBY FNQ PLANS: ' ,IST NOTED C A1��1 ��||J|01863.00 FL FINISH 1785 SF SCALEUNLESS FIRST DRAWN BY JRM 2 1 1 A402 A401 P.�1 A402 67-0' 16'-0' 9'-0' 29-0' 91-0' 11'-11' a-1' 7-0' 4'-91/7' 7-21/2" 6-0' 4- 4'-107/Er 3'-1 3'-1- 4'-107/8' � 6'-01/4" -21/7 4'-91/2' DORMER DORMER DORMER l01/T� 6'-T �-101/T A A F G G G F I � I 1 A303 OF STUD BELOW KITCHEN VENT - HOOD DUCT PATH UP TO REAR ROOF W/INLINE BLOWER I I Fo I �lStEitE0'4t/�✓s Qy D. �. O �y a .ass 51 OF 10 d� PROPOSED PARKER RESIDENCE MISHAUM POINT RD. DARTMOUTH MA 02748 1 A302 DSK Dewing Schmid Kearns ARCHITECTS + PLANNERS Suite 200E 30 Monument Square Concord, MA 01742 978.371.7500 280 Elm Street South Dartmouth MA 02748 www.dskap.com PERMIT SET AUGUST 16TH 2O19 NO I DATE I ISSUED TO BY T1TL PLANS: SECOND FLOOR NOTE' DATE 08/16/19 ALL DIMENSIONS TO FACE Of STUD A 102 UNLESS NOTED OTHERWISE SCALE im, 1'-0" JOB NO. 01863.00 SECOND FLOOR- BUILDING PLAN DRAWN BY JRM 1 ELECTRICAL LEGEND LL� - - - SYMBOL FDEFINITION - SYMBOL DEFINITION SYMBOL DEFINITION switch �e.xpe cor Qcr� ground fault interrupter outlet junction box away switch Q weatherproof outlet ® electric panel 1 way switch (gyp spp��prcrpose outlet � electric subpanel rla D dimmer switch Qzu 21 vouTlei ®,b u!a 1-,fto r .r.l � telephone lack garage door switch duplex outlet w/ switched leg g>- data jack (cat6 ethernet) wireless switch ;J .. weatherproof floor outlet w/recessed plug r� I� cable T.v. jack jamb switch 1� brass floor outlet with recessed plug 0 t hvac ThemrostaT ..ay ma�rom�:nr •.a=th= ht(eo ou) Q duplex outlet _m �r nsa.rtl �rM door bell heat detector Q duplex outlet a.r.r. door bell chime Q smoke detector quad outlet $ speaker combo. smoke / carbon detect ❑ ❑ ❑ ❑ ❑ ❑ BASEMENT - RCP A200 1 /4" = V-9' o® ��S�aEDagGH D. 1 0 a xss » r erar3r' PROPOSED PARKER RESIDENCE MISHAUM POINT RD. DARTMOUTH MA 02748 DSK IDewing Schmid Kearns ARCHITECTS * PLANNERS TITL Suite 200E 30 Monument Square Concord, MA 01742 978.371.7500 280 Elm Street South Dartmouth MA 02748 www.dskap.com PERMIT SET AUGUST 16TH 2O19 REVISION RCPs: BASEMENT RCP DATE 08/16/19 JOB NO. 01863.00 L DRAWN BY JRM ELECTRICAL LEGEND SYMBOL DEFINITION SYMBOL DEFINITION ------- --- SYMBOL DEFINITION $ switch cn ground fault interrupter outlet ❑ junction box 3 way switch weatherproof outlet -EP electric panel 4 way switch special purpose outlet- sp electric sub -panel dimmer switch W25 215-vourtlet WIL t.lephonejack garage door switch W duplex outlet wl switched leg g>— -- - - — - data jack (cat6 ethernet) - — ---------- ----- wireless switch weatherproof floor outletw/recessed plug. >IY- cable I- jack - - -------- jamb —itch brass floor outlet with recessed plug - - - - - -- - ------ - -------- h-c thermostat duplex outlet 0oe :doorbell heat detector 4 .1 i duplex outlet door bell chime smoke detector ------------- quad outlet @ speaker combo. smoke / carbon detect. INT. CROWN DETAIL 6'= V-9' 101 SCOTIA BOARD JARTER ROUND INT. BEAM DETAIL 1,A2JOI 6"= I'-C" BOARDS WOVEN RNER TYP. FIRST FLOOR - RCP PROPOSED PARKER RESIDENCE MISHAUM POINT RD. DARTMOUTH MA 02748 DSK IDewing Schmid Kearns ARCHITECTS , PLANNERS TITL Suite 2DOB 30 Monument Square Concord, MA 01742 978.371.7500 280 Elm Street South Dartmouth MA 02748 —W.dskap.com PERMIT SET AUGUST 16TH 2019 REVISION RCPs: FIRST FLOOR RCP 08/16/19 -E As indicated A201 0.. 11863.00 N 0, WN BY JR. ELECTRICAL LEGEND SYMBOL DEFINITION SYMBOL DEFINITION SYMBOL DEFINITION $ switch nmma �vr wr �cn ground fault Interrupter outlet ❑ junction box 3 way switch (j weatherproof outlet ev electric panel $1 4 way switch Wsr special purpose outlet aeeka an sP electric sub -panel $o dimmer switch (p_ 215A, outlef telephone jack garage door switch 91­1 duplex outlet w/ switched leg data jack (cat6 ethernet( wireless switch i1_1 weatherproof floor outlet w/recessed plug �r acmwn n nesv Irv. 1� cable t.v. jack jamb switch 1� brass floor outlet with recessed plug verwy ecamru n f O hvac thermostat mwntip ha ht (W arrl ®uplouHet ae arq Oos doorbell heat defector 94 duplexouileI niounrtq hegM a.f.i. door bell chime 0 smoke detector quad outlet $ speaker combo. smoke / carbon detect gtfREOgq� q o � A rov xss d� a<yrae�sbP PROPOSED PARKER RESIDENCE I MISHAUM POINT RD. TILED SHOWER CEILING DARTMOUTH MA 02748 TITL DSK IDewing Schmid Kearns ARCHITECTS+ PLANNERS Suite 200E 30 Monument Square Concord, MA 01742 978.371.7500 280 Elm Street South Dartmouth MA 02748 www.dskap.com PERMIT SET AUGUST 16TH 2O19 r(i] RCPs: SECOND FLOOR RCP JOB DATE 08/16/19 cALE N 1/4'"=1'-0" A202 SECOND FLOOR - RCP NO. 01863.00 1'-0" ® DRAWN BY ARM o 2 c ELEVATIONS: NORTH ELEVATION DATE 08/16/19 SCALE qr=v-o" JOB NORTH BUILDING ELEVATION DRAWN BY RM RM 0186J A301 1/47= 1'-0' ® DRAWN o z a a TE49 CROWN /BLOCKING s DORMER RAKE A401 1 1 /T = V-u, HEADER SET FLUSH W/ROOF RAFTER TYR. AT DORMERS CEDAR BREATHER DRAINAGE - PLANE ALLOWED TO WEEP WOLF TE49 CROWN SET PERP. TO ROOF SLOPE TO RETURN UP DORMER EAVE' 1x5 Ix TIGHT TO TOP OF CASING CONTINUOUS (2) 2X6 WALL PLATE 4.. ."3 4 DORMER EAVES A401 1 1 IT = 1'-0" ;ROWN OFFIT / CEIL. TYR D KING GAP TO LANE '.WRAPPED REEN TYP. s MAIN RAKE A401 1 1 /T = F-a' AA YP. >THER DRAINAGE- WED TO WEEP CROWN SOFFIT/CEIL TYP. -. --- - - - - _. or_ '' — -: w_ x --- --- -- - I - - - -- -- -.:::: -, -:. _. - G + o -------' - - _ -- --- ... - .. _ _ _ -basement TYP. SUB -SURFACE 13250 -- - -DRAIN:- -- PERFORATED PVC PIPE ,. MAX. SEASONAL ':. -WRAPPED IN FILTER FABRIC SET IN GRAVEL - HIGH WATER -- - - ---`:. CONNETED TO ALL DOWNSPOUTS - -- -' --'DRAINING TO DAYLIGHT f- TYP. SLAB CONSTRUCTION: :.:4"CONCRETE SLAB W/WWM REINF. PER STRUCf.DWGS. OVER POLY. VAPOR BARRIER -: OVER (2) LAYERS 1' RIGID INSULATION (R-10 MIN.) OVER 17 CRUSHED STONE - OVER COMPACTED FILL --. .... ,� -- - -- - _ AUGUST 16TH 2O19 NO. DATE REVISION NO DATE ISSUED TO TITL 2 MAIN EAVES BY E OVERHANG BEYOND TYPICAL R W/O FRIEZE (SHOWN HERE I /ER TRIM BOARD SIDING SHINGLE TED TRIM BOARD W/ROOF PITCH CHANGE SPRAY FOAM INSUL/ W/INTUMESCENT PAINT W 6' DEEP PEC AT FRC SOT. ALIGNS W (6) 2-1/4' TYR. IX8 FRIEZE W PITCHET OI FRONT GABLE I HEAD CASII W/WOLF-TE49 GABLE INSET TRIM A402 3" = 1'-0" HEADER SET IN FLOOR FRAMING CONTINUOUS (2) 2x6� FOUNDATION PLATE TYR. SHINGLE WALL SWEEP'I , PER DETA 2X BLOCKING AS NEE IE ABOVE WINDO .. SINGLE PT PLATE UNDER WIND { PERIMETER DRAIN IN FILTER FABRI SET IN GRAVEL A 3" INSULATION BOARD BASEOF WINDOW WEL I0' FOUND. WALL (PER STRUCT. DWGS) 1/2'JOINT FILLER TOPPED OF W/ FLEXIBLE JOINT SEALANT TYR. AT PERIMETER OF SLAM GABLE PACKOUT RAINSCREEN MESH DRAINAGE PLANE CONTINUOUS OVER SWEEP BLOCKING PT WALL -SWEEP BLOCKING CUT TO 3- AT BASE TO SHEATHING OVER MIN.3 SHINGLE COURSES & WRAPPED IN VAPOR PERMEABLE MEMBRANE SEALED TO FRAME WALL AVB & FOUND. SEALER PROVIDE AIR GAPTO DRAINAGE PLANE N/TOP & BOT. WRAPPED IN INSECT SCREEN TYR. SEAL BETWEEN FRAME WALL AVB & FOUNDATION WATERPROOFING OVER SWEEP BLOCKING STYRO FLEXCOAT BRUSH -APPLIED TO EXPOSED FOUNDATION INSULATION TYR. 4 SHINGLE WALL SWEEP A402 1 1 /2" = F-a' gtE0.EflAq� �G 0' ax ass PROPOSED PARKER RESIDENCE MISHAUM POINT RD. DARTMOUTH MA 02748 DSK IDewing Schmid Kearns ARCHITECTS + PLANNERS Suite 200E 30 Monument Square Concord, MA 01742 978.371.7500 280 Elm Street South Dartmouth MA 02748 www.dskap.com PERMIT SET AUGUST 16TH 2O19 .. ,. ... I NO. DATE REVISION SION BY I LL _ 47, --- — ;, f — IStfloorsubfloor NO DATE ISSUED TO BY TITL SECTIONS: u o.`ikh f BUILDING SECTIONS & EXT.DETAILS — — - — iu— — — — — - basement 8 DATE 08/16/19 r .:;" `v - _ ,� w T SCALE As indicated A402 QSECTION AT CROSS GABLE ' -- - - - OBNO. o1863.00 A402 1/4"= 1'-0" 2 SECTION AT GAMBREL WING a 1/4"= 1'-T — DRAWN BY JRM LITTLE RIVER ROAD BENCHMARK: 1. CUT NAIL IN UTILITY POLE #294/13 LOCATED ALONG MISHAUM POINT ROAD, 110'f SOUTH OF MAINTENANCE BUILDING ON SUB LOT #2. ELEVATION = 26.08 (NAVD 88) w. k=. DARTMOUTH SITE ING t674) o, 11 MARK A. BOUCHER, P.L.S. 32 MA REG. NO. 41246 0 ,o SITE LOCUS SCALE: 1 "=2000' MARK A. BOUCHER NO.4124d . DATE O� Q 4Jtiti FOUNDATION AS -BUILT PLAN PLAT 11, LOT 33 (AN R LOT 1) 63 MISHAUM POINT ROAD, DARTMOUTH, MA SCALE: 1 "=30' DATE: NOVEMBER 4, 2019 PREPARED FOR PARKER MISHAUM PARTNERSHIP PREPARED BY BOUCHER & ASSOCIATES, INC. LAND SURVEYORS AND CONSULTANTS 999 MAIN ROAD, UNIT #2, WESTPORT, MASSACHUSETTS 02790 TEL 508-636-5905 FILE: 3333-01—L0T1—FNDN—ASBLT.dwg GENERAL USE STRUCTURAL DRAWINGS IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS. COORDINATE ALL STRUCTURAL WORK WITH THE WORK SHOWN ON ARCHITECTURAL DRAWINGS AND WITH THE WORK OF OTHER TRADES, INCLUDING MECHANICAL, ELECTRICAL, PLUMBING, AND WITH SITE DRAWINGS. CONSULT THESE 4 DRAWINGS AND COORDINATE WITH OTHER TRADES FOR LOCATIONS AND DIMENSIONS OF PIPES, OPENINGS, CHASES, AND OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS. FASTENERS UTILIZED FOR FRAMING CONNECTORS SHALL BE THE TYPE. SIZE, AND QUANTITY SPECIFIED IN THE FRAMING CONNECTOR MANUFACTURERS CATALOG. 4'- ALL OTHER FASTENERS SHALL BE COMMON NAILS AS INDICATED OR IN ACCORDANCE WITH THE CODE FASTENER SCHEDULES WHERE NOT INDICATED. IF THE CONTRACTOR PROPOSES TO UTILIZE NAIL GUN FASTENERS, IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE DOCUMENTATION CONCERNING THE SUITABILITY OF THE PROPOSED FASTENERS AS SUBSTITUTES FOR COMMON NAILS. FOR ELEMENTS NOT INCLUDED AS PART OF THIS PACKAGE, ALL WORK SHALL CONFORM TO THE WFCM AND IRC ASAMENDED. DIMENSIONS SHOWN ARE FOR DESIGN PURPOSES ONLY. REFER TO ARCHITECTURAL DRAWINGS FOR LAYOUT DIMENSIONS. WHERE APPLICABLE COORDINATE ALL DIMENSIONS AND ELEVATIONS WITH EXISTING CONDITIONS. THE CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY SHORING AND BRACING AND FOR CONSTRUCTION SITE SAFETY. ALL WORK SHALL BE SUPERVISED BY A CONSTRUCTION SUPERVISOR LICENSED IN THE COMMONWEALTH OF MASSACHUSETTS. • THE WORK SHALL COMPLY WITH ALL LOCAL PERMIT APPROVAL DOCUMENTS, BYLAWS, ZONING REGULATIONS, AND CONSERVATION COMMISSION ORDER OF CONDITIONS, AS APPLICABLE. UNCOVERED CONDITIONS THAT DIFFER FROM THOSE PRESUMED ON THE STRUCTURAL SKETCHES ARE SUBJECT TO REVIEW BY THE ENGINEER. MATERIAL SUBSTITUTIONS THE STRUCTURAL DESIGN FOR THIS PROJECT IS BASED ON USING THE PRODUCTS AND MATERIALS SPECIFIED HEREIN, INCLUDING BUT NOT LIMITED TO LAMINATED VENEER LUMBER, PARALLEL STRAND LUMBER, AND ENGINEERED WOOD JOISTS. THE CONTRACTOR IS RESPONSIBLE FOR ANY SUBSTITUTIONS MADE FOR THE SPECIFIED PRODUCTS. IF THE CONTRACTOR REQUIRES RIVERMOOR'S CONCURRENCE FOR PRODUCT SUBSTITUTIONS, SUBMIT MEMBER DESIGN PROPERTIES FOR PROPOSED PRODUCTS. CODE THE INTERNATIONAL RESIDENTIAL CODE FOR ONE -AND TWO-FAMILY DWELLINGS (IRC 2015) THE MASSACHUSETTS RESIDENTIAL CODE (780 CNR 51.DO) NINTH EDITION (MA AMENDMENTS TO THE IRC) MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, ASCE 7-10 AMERICAN CONCRETE INSTITUTE, ACI 318-14 STEEL CONSTRUCTION MANUAL, AISC, 14Ih EDITION WOOD FRAME CONSTRUCTION MANUAL FOR ONE -AND TWO-FAMILY DWELLINGS, WFCM LIVE LOADS BASIC WIND SPEED (VUI): 139 MPH (MASS AMENDMENTS) WIND EXPOSURE CATEGORY: C GROUND SNOW LOAD, Pg: 30 PSF (MASS AMENDMENTS) LIVING AREAS: 40 PSF SLEEPING AREAS: 30 PSF ATTICS WITH FIXED STAIR ACCESS: 30 PSF ATTIC WITH STORAGE AND NO FIXED STAIR: 20 PSF ATTIC WITHOUT STORAGE: 10 PSF (LESS THAN 42' VERTICAL CLEARANCE) PORCHES, DECKS, AND BALCONIES: 40 PSF FOUNDATIONS NOTIFY DIG SAFE PRIOR TO FOUNDATION EXCAVATION THE MINIMUM CONCRETE REQUIREMENTS SHALL BE AS FOLLOWS: • FOOTINGS o COMPRESSIVE STRENGTH: 4,000 PSI @ 28 DAYS o AIR ENTRAINMENT: NOT REQUIRED • PERIMETER FOUNDATION WALLS o COMPRESSIVE STRENGTH: 4,000 PSI Q 28 DAYS o MAXIMUM SLUMP: B' o AIR ENTRAINMENT: 5 TO 7% THE MINIMUM CONCRETE UNIT MASONRY REQUIREMENTS FOR FOUNDATION WALLS SHALL BE AS FOLLOWS (ALL UNIT MASONRY FOUNDATION WALLS SHALL BE CONSTRUCTED ON CAST -IN -PLACE CONCRETE FOOTINGS): • MASONRY UNITS: ASTM C90 • MORTAR: ASTM C270 TYPE M OR S • GROUT COMPRESSIVE STRENGTH: 2,ODO PSI @ 28 DAYS CONFORMING TO ASTM C476 REINFORCING STEEL #3 BARS: ASTM AJH5 GR 40 (MIN) #4 AND LARGER BARS: ASTM A615 GR 60 WWF: ASTM A185 REINFORCING STEEL SHALL BE CONTINUOUS THROUGH ALL CONSTRUCTION JOINTS, INTERSECTIONS, AND CORNERS UNLESS OTHERWISE NOTED. THE DESIGN OF FOUNDATIONS AND BASEMENTICRAWL SPACE SLABS IS BASED ON A GROUNDWATER ELEVATION BELOW THE BASEMENT FLOOR LEVEL. THE FOUNDATION AND BASEMENT/CRAWLSPACE SLABS HAVE NOT BEEN DESIGNED FOR ANY NET UPLIFT PRESSURE DUE TO HIGHER GROUNDWATER ELEVATIONS. VERIFICATION OF THE ACTUAL GROUNDWATER ELEVATION, INCLUDING ANY SEASONAL FLUCTUATION, IS NOT BY RIVERMOOR ENGINEERING. THE DESIGN OF FOUNDATION ELEMENTS IS BASED ON AN ALLOWABLE PRESUMPTIVE SOIL BEARING PRESSURE OF 3,000 PSF, WHICH CORRESPONDS TO UNDISTURBED SANDY GRAVEL AND/OR GRAVEL WITH NO COMPRESSIBLE OR ORGANIC MATERIAL, OR BETTER THE ACTUAL SOIL CONDITIONS SHALL BE VERIFIED BY THE CONTRACTOR. ALL FOUNDATION ELEMENTS SHALL BE PLACED EITHER ON UNDISTURBED MATERIAL OR ON A MAXIMUM OF IT COMPACTED GRANULAR FILL NOTIFY THE ENGINEER IF THE PRESUMED SOIL CONDITIONS ARE NOT APPLICABLE. FOUNDATION DETAILS ARE BASED ON CONTINUOUS PLACEMENT OF FOUNDATION WALL CONCRETE. NOTIFY THE ENGINEER IF HORIZONTAL CONSTRUCTION JOINTS ARE PLANNED, PROTECT FOUNDATION AND SLAB SUBGRADE FROM THE ACCUMULATION OF GROUNDWATER AND FROM FREEZING THROUGHOUT THE CONSTRUCTION PERIOD. COMPLY WITH REQUIREMENTS, RECOMMENDATIONS, MATERIAL SPECIFICATIONS, AND INSPECTIONS INCLUDED IN THE GEOTECHNICAL REPORT. ALL FOUNDATION WALLS WITH UNBALANCED SOIL LOADING SHALL BE BACKFILLED WITH FREE -DRAINING GRANULAR MATERIAL AND SHALL HAVE PERIMETER DRAINAGE ALONG THE BASE OF THE WALLS. WALLS SHALL NOT BE BACKFILLED UNTIL FIRST FLOOR FRAMING AND SHEATHING AND BASEMENT FLOOR SLAB ARE IN PLACE AT LOCATIONS WHERE NEW FOUNDATIONS MEET EXISTING, STEP NEW FOUNDATIONS UP OR DOWN AS REQUIRED TO MATCH THE EXISTING BOTTOM OF FOOTING ELEVATION. DO NOT PLACE NEW FOUNDATION ELEMENTS ON PREVIOUSLY DISTURBED MATERIAL OR ON PREVIOUSLY PLACED BACKFILL AT LOCATIONS WHERE BOTTOM OF FOOTING ELEVATIONS VARY, PROVIDE STEPPED FOOTING TRANSITION. DO NOT PLACE NEW FOUNDATION ELEMENTS ON PREVIOUSLY DISTURBED MATERIAL OR ON UNCONTROLLED BACKFILL IF LEDGE IS ENCOUNTERED ABOVE THE MINIMUM FROST DEPTH, PIN FOUNDATION WALLS TO LEDGE WITH #4 BARS DRILLED AND EPDXY GROUTED WITH W MINIMUM EMBEDMENT AT 4 FT OC UNLESS NOTED OTHERWISE. REFER TO ARCHITECTURAL DRAWINGS FOR LIMITS AND DETAILS FOR FOUNDATION WALL INSULATION, WATERPROOFING, AND/OR DAMPPROOFING. FLOOR SLABS ON GRADE THE MINIMUM CONCRETE COMPRESSIVE STRENGTH SHALL PE 3,5DO PSI THE MINIMUM BASEMENT SLAB THICKNESS SHALL BE 3-17. THE MINIMUM GARAGE FLOOR SLAB THICKNESS SHALL BE 4': REFER TO ARCHITECTURAL DRAWINGS FOR UNDER -SLAB VAPOR BARRIER REQUIREMENTS FOR ANY SLABS WITH RADIANT HEATING SYSTEMS, COMPLY WITH SYSTEM MANUFACTURER AND INSTALLER REQUIREMENTS FOR SLAB ASSEMBLY AND JOINT DETAILS. REFER TO SECTION R506 OF THE CODE AND SECTION RW6+1 OF THE MASS AMENDMENTS FOR SURFACE PREPARATION, BASE COURSE, SLAB REINFORCING STEEL, AND CONTROL JOINT SPACING. COORDINATE ALL CONTROL JOINT LOCATIONS WITH THE ARCHITECT. STRUCTURALSTEEL WIDE FLANGE SHAPES: ASTM ABU GR 50. PIPE COLUMNS: ASTM A53 GRADE B SQUARE COLUMNS: ASTM A500 GRADE B MISC PLATES: ASTM A36 HIGH STRENGTH BOLTS: ASTM A325 COMMON BOLTS: ASTM A307 WELDING ELECTRODE: E70XX THE STRUCTURAL STEEL MEMBERS AND ASSEMBLIES FOR TINS PROJECT ARE PART OF A WOOD -FRAMED BUILDING. ALL STEEL MEMBERS AND ASSEMBLIES SHALL BE TEMPORARILY SUPPORTED AND BRACED UNTIL FULLY CONNECTED WITH THE WOOD FRAMING ELEMENTS. ALL BEAMS SHALL BE FABRICATED AND INSTALLED WITH MILL CAMBER FACING UP ALL BEAMS SHALL BE SHOP DRILLED OR PUNCHED TO ACCOMMODATE TOP FLANGE NAILERS AND/OR WEB PADDING AS INDICATED OR REQUIRED. FLUSH BEAM WEB PADDING: UNLESS OTHERWISE INDICATED, WEB PADDING SHALL CONSIST OF LVL, RIPPED TO FIT TIGHT BETWEEN FLANGES, AND SHIMMED TO BE FLUSH WITH THE FLANGES. PADDING SHALL BE FASTENED TO THE BEAM WEB WITH W DIA COMMON BOLTS AT IS' OC (STAGGERED). FRAMED BEAM CONNECTIONS NOT DETAILED ON THE DRAWINGS SHALL BE DESIGNED BY THE STEEL FABRICATOR FOR ONE44ALF OF THE BEAM CAPACITY BASED ON THE APPLICABLE AISC UNIFORM LOAD TABLES. BEAM TO COLUMN CONNECTIONS NOT DETAILED ON THE DRAWINGS SWILL BE DETAILED BY THE STEEL FABRICATOR. UNLESS OTHERWISE INDICATED, THE COLUMN CONNECTIONS SHALL BE MADE TO THE BOTTOM FLANGE OF THE BEAMS AND MAY BE WELDED AND/OR BOLTED. PROVIDE W PAIRED WEB STIFFENERS TO THE BEAM, ALIGNED WITH THE COLUMN CENTERLINE. DIMENSION LUMBER ALL INTERIOR OR OTHERWISE PROTECTED DIMENSION LUMBER SHALL BE SPRUCE -PINE -FIR (SPF) GRADE NO.2 OR BETTER FOR RAFTERS, JOISTS, AND HEADERS, AND STUD GRADE FOR STUDS, UNLESS NOTED OTHERWISE. DIMENSION LUMBER FOR THE FOLLOWING LOCATIONS SHALL BE PRESSURE PRESERVATIVE -TREATED SOUTHERN PINE #2 OR BETTER • PORCHES, DECKS, AND OTHER FRAMING EXPOSED TO THE WEATHER • INTERIOR WOOD JOISTS WITHIN 18' OF EXPOSED GROUND • INTERIOR TIMBER OR BUILT-UP BEAMS WITHIN 17 OF EXPOSED GROUND • SILL PLATES • ALL FRAMING MEMBERS SUPPORTED ON CONCRETE OR MASONRY EXTERIOR FOUNDATIONS LESS THAN 8' FROM EXPOSED GROUND • ALL WALL FRAMING AND SHEATHING LESS THAN 6' FROM EXPOSED GROUND • TIMBER OR BUILT-UP BEAMS IN CONCRETE OR MASONRY BEARING POCKETS WITH LESS THAN W CLEARANCE AT TOP, SIDES, AND ENDS • WOOD FRAMING AND SHEATHING SUPPORTING CONCRETE OR TILE OVERLAYS EXPOSED TO THE WEATHER • INTERIOR WOOD LEDGERS FASTENED TO CONCRETE OR MASONRY WALLS ALL WOOD IN CONTACT WITH THE GROUND SHALL BE RATED AS SUCH. ALL DIMENSION LUMBER SHALL BE IDENTIFIED BY THE GRADE MARK OF AN APPROVED LUMBER GRADING AGENCY. LUMBER SHALL BE GENERALLY FREE FROM SPLITS & WARPAGE THAT CANNOT BE CORRECTED BY BRIDGING OR NAILING. MOISTURE CONTENT OF LUMBER SHALL NOT EXCEED 19% AT THE TIME OF CONSTRUCTION, LAMINATED VENEER LAMINATED VENEER LUMBER (LVL) LAMINATED VENEER LUMBER SHALL BE 1.9E TJ MICROLAM LVL BY TRUS JOIST, OR APPROVED EQUAL, UNLESS OTHERWISE INDICATED. PARALLEL STRAND LUMBER (PSL) PARALLEL STRAND LUMBER SHALL BE 1.8E PARALLAM PSL BY TRUE JOIST, OR APPROVED EQUAL, UNLESS OTHERWISE INDICATED. PSL MEMBERS EXPOSED TO WEATHER, WITHIN S' FROM EXPOSED GRADE, ON OR AGAINST CONCRETE, MEMBERS USED FOR DECKS OR EXTERIOR BALCONIES, SHALL BE TREATED WITH PRESERVATIVE. ENGINEERED WOOD JOISTS JOISTS AND ACCESSORIES INCLUDING RIM JOISTS SHALL BE THE PRODUCTS OF TRUS JOIST, OR APPROVED EQUAL FOR FIRE RETARDENT TREATMENT OF THE FIRST FLOOR JOISTS, REFER TO THE BUILDING CODE. SHEATHING ALL ROOF, FLOOR, AND WALL PANELS SHALL BE APA RATED EXPOSURE 1 SHEATHING COMPLYING WITH DOC PS 1 AND PS 2. FULL 4XS PANELS SHALL BE USED TO THE MAXIMUM EXTENT PRACTICABLE FLOOR SHEATHING (GENERAL) MINIMUM SPAN RATING: 32/16 MINI MUM THICKNESS: %IN GLUED AND NAILED WITH TONGUE AND GROOVE JOINTS FASTENERS: 8d COMMON AT 8' OC ALONG SUPPORTED EDGES AND 17 OC INTERMEDIATE NOTE: USE APA RATED STURD4-FLOOR OR ADVANTECH IF SPECIFIED ON ARCHITECTURAL DRAWINGS ROOF SHEATHING MINIMUM SPAN RATING: 32116 MINIMUM THICKNESS: SM IN FASTENERS: Sd COMMON FASTENER SPACING GENERAL' S' OC ALONG SUPPORTED EDGES AND 6' OC INTERMEDIATE WITHIN 4 FT OF GABLE END WALLS: 4' OC ALL PANELS SHALL BE STAGGERED WITH SHORT EDGE PARALLEL TO ROOF RAFTERS, LION. WALL SHEATHING (GENERAL) MINIMUM THICKNESS: 71161N FASTENERS: 8d COMMON AT S' OC ALONG EDGES AND 17 OC INTERMEDIATE, UNLESS NOTED OTHERWISE SILL ANCHORAGE, HOLD-DOWNS AND FRAMING CONNECTORS ALL STRUCTURAL FRAMING CONNECTIONS, UNLESS SPECIFICALLY NOTED OTHERWISE, SHALL BE -STRONG TIE - AS MANUFACTURED BY THE SIMPSON CO. IN ACCORDANCE WITH "WOOD CONSTRUCTION CONNECTORS' CATALOG CC,2017. ALL FASTENERS (TYPE, SIZE, AND QUANTITY) SPECIFIED IN SIMPSONS CONNECTOR SCHEDULE SHALL BE INSTALLED. SILL PLATE ANCHOR BOLT OPTIONS: ZO CAST -IN -PLACE: 5V DIA ASTM A307 GALVANIZED J-BOLTS OR HEADED BOLTS WITH GALVANIZED '/. X 3X3 a PLATE WASHERS AND NUTS. ANCHOR BOLT EMBEDMENT SHALL BE 7' (MINIMUM} DRILLED -IN: SIMPSON 5I8' DIA X S' LONG TTTEN HO WITH GALVANIZED X 3X3 PLATE WASHERS. coW NOTE: 3X3 WASHER PLATES FOR WFCM DESIGN ONLY W FOR ANCHOR BOLT LAYOUT, SEE STRUCTURAL SKETCHES. POST AND BEAM CONNECTIONS: F 0 ALL DIMENSION LUMBER, PSL, AND STEEL POSTS SHALL BE POSITIVELY Z CONNECTED TO THE FOUNDATION BELOW AND THE BEAM ABOVE, AS APPLICABLE. UNLESS NOTED OTHERWISE, PROVIDE SIMPSON POST OR O COLUMN BASES AND SIMPSON POST OR COLUMN CAPS TO SUIT EACH F- CONDITION UQ SHEAR WALL HOLD-DOWN ANCHOR BOLT OPTIONS: CAST -IN -PLACE: SIMPSON SB SERIES ANCHOR BOLTS, DIAMETER AND iS EMBEDMENT AS INDICATED, UNLESS NOTED OTHERWISE a�3ES �p DRILLED4N: SIMPSON ET ACRYUC-TIE ADHESIVE WITH ASTM A307 HOT DIP GALVANIZED THREADED ROD, DIAMETER AND EMBEDMENT AS INDICATED, y UNLESS NOTED OTHERWISE REFER TO STRUCTURAL SKETCHES AND/OR WALL BRACING SCHEDULE �%' 400 FOR ADDITIONAL INFORMATION ALL CONNECTORS AND FASTENERS FOR PRESSURE PRESERVATIVE TREATED WOOD SHALL BE SHOP -COATED AND/OR STAINLESS STEEL TO SUIT THE SPECIFIC EXPOSURE(S) AND WOOD PRESERVATIVE(S) IN ACCORDANCE WITH SIMPSON STRONG -TIE RECOMMENDATIONS. THE CONTRACTOR SHALL REVIEW DOCUMENTATION CONTAINED IN THE SIMPSON STRONG -TIE CATALOG AND PROVIDE CONNECTORS AND FASTENERS THAT ARE ACCEPTABLE FOR THE EXPOSURE AND CHEMICAL PRESERVATIVES USED ON THE PROJECT. THE REVIEW SHALL CONSIDER THE TYPE OF PRESERVATIVE(S), PRESERVATIVE RETENTION LEVEL(S), AND EXPOSURE ENWRONMENT(S). ALL CONNECTORS AND FASTENERS FOR EXPOSED PORCH AND DECK FRAMING IN COASTAL ENVIRONMENTS SHALL BE TYPE 316 STAINLESS STEEL v 0 WHERE SO NOTED ON ARCHITECTURAL DRAWINGS, PROVIDE STAINLESS STEEL CONNECTORS AND FASTENERS C Li C REGARDLESS OF EXPOSURE. C FRAMING INSTALLATION U) •0 ALL FRAMING SHALL BE ERECTED TRUE TO LINE, PLUMB AND LEVEL, AND SHALL BE FASTENEDMUNG TO ^ DEVELOP THE FULL STRENGTH OF THE ASSEMBLY IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. �i O Li L E NEW DIMENSION LUMBER JOISTS FRAMING INTO FLUSH STEEL OR LVL BEAMS SHALL BE SET W ABOVE THE TOP OF BEAM ELEVATION TO ACCOMMODATE Q) —1 SHRINKAGE. i ALL CONTINUOUS WOOD AND/OR STEEL POSTS SHALL BE LATERALLY BRACED IN BOTH DIRECTIONS AT EACH L- = 0 FLOOR AND CEILING LEVEL y ALL ENGINEERED PRODUCTS SHALL BE STORED AND INSTALLED IN ACCORDANCE WITH PRODUCT A MANUFACTURERS' SPECIFICATIONS AND INSTALLATION DETAILS. WITH THE EXCEPTION OF F G MANUFACTURER -PROVIDED KNOCKOUTS, NO HOLES SHALL BE FIELD -DRILLED IN MEMBERS. IF HOLES ARE yr REQUIRED, NOTIFY THE ENGINEER PRIOR TO ORDERING AFFECTED MEMBERS. (� FLOOR SHEATHING SHALL BE GLUED AND NAILED. PROVIDE ZX WOOD BLOCKING OR RIM JOIST AT ALL SAWN LUMBER FLOOR JOIST SUPPORT POINTS. L• a PROVIDE BLOCKING OR RIM BOARD AT ALL ENGINEERED FLOOR JOIST SUPPORT POINTS. USE JOIST MANUFACTURERS PRODUCTS AND COMPLY WITH JOIST MANUFACTURER'S INSTALLATION DETAILS, PROVIDE 2X SOLID BLOCKING AT ALL RAFTER TAILS. ,^ PROVIDE DOUBLE FLOOR JOISTS OR BLOCKING BELOW ALL NEW INTERIOR PARTITION WALLS. W PROVIDE DOUBLE FLOOR JOISTS WITHIN LIMITS OF TUBS. O COORDINATE KITCHEN ISLAND AND OTHER SPECIAL LOADING CONDITIONS WITH THE ENGINEER. Z SIZES OF DIMENSION LUMBER ARE NOMINAL. ALL LUMBER SHALL BE SURFACED FOUR SIDES, UNLESS NOTED ...I OTHERWISE. Q STRUCTURAL MEMBERS SHALL NOT BE IMPAIRED OR UNDERMINED BY IMPROPER CUTTING OR DRILLING. W ALL BUILT-UP LVL BEAMS SHALL BE ASSEMBLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. Z INTERIOR WALL FRAMED OPENINGS �W V AT EACH END OF SAWN LUMBER DOOR AND WINDOW HEADERS, PROVIDE ONE JACK STUD AND ONE KING STUD UNLESS OTHERWISE INDICATED. AT EACH END OF LVL DOOR AND WINDOW HEADERS, PROVIDE TWO JACK STUDS AND ONE KING UNLESS J OTHERWISE INDICATED. EXTERIOR WALL FRAMED OPENINGS to J o AT EACH END OF SAWN LUMBER DOOR AND WINDOW HEADERS, PROVIDE ONE JACK STUD AND KING STUDS PER Z �o SCHEDULE BELOW, UNLESS OTHERWISE INDICATED. tm� Q N AT EACH END OF LVL DOOR AND WINDOW HEADERS, PROVIDE TWO JACK STUDS AND KING STUDS PER W ru Z U) SCHEDULE BELOW, UNLESS OTHERWISE INDICATED. _ MAX HEADER SPAN, FT KING STUDS, EACH END - Z tj Q !g m 4 1 W ¢W¢NN� 160 3 0 yi 12 4 0 m SCOPE OF STRUCTURAL ENGINEERING SERVICES MH W LL THE STRUCTURAL ENGINEER HAS PERFORMED THE STRUCTURAL DESIGN AND PREPARED THE STRUCTURAL = W" J Q WORKING DRAWINGS FOR SPECIFIC ELEMENTS FOR THIS PROJECT. DESIGN IS LIMITED TO ONLY THOSE STRUCTURAL ELEMENTS IDENTIFIED ON THE ENCLOSED DRAWINGS. THE CONSTRUCTION MUST BE PERFORMED IN STRICT ACCORDANCE WITH THE STRUCTURAL DETAILS AND LOCAL CODE REQUIREMENTS. ANY DEVIATION FROM THE DRAWINGS MUST BE APPROVED IN WRITING BY THE STRUCTURAL ENGINEER ANY DISCREPANCY BETWEEN THE STRUCTURAL DRAWINGS AND THE ARCHITECTURAL DRAWINGS SHALL BE - BROUGHT TO THE STRUCTURAL ENGINEER'S ATTENTION. JOB -SITE SAFETY JOB -SITE SAFETY IS THE CONTRACTORS RESPONSIBILITY. ALTHOUGH RIVERMOOR ENGINEERING MAY VISIT THE JOB -SITE ON ONE OR MORE OCCASIONS, SUCH VISITS ARE FOR CLARIFICATION OF SPECIFIC STRUCTURAL DESIGN ISSUES ONLY, AND ARE NOT FOR THE PURPOSES OF IDENTIFYING POTENTIAL JOB SITE SAFETY ISSUES. .. THE US DEPARTMENT OF LABOR (OSHA) WEBSITE PROVIDES DIRECTION IN THE FORM OF A JOB -SITE SAFETY 111 m m HANDBOOK FOR RESIDENTIAL CONSTRUCTION THAT INCLUDES- BUT IS NOT LIMITED TO -REQUIREMENTS FOR p w 1n m N w W HEAD AND EYE PROTECTION, LADDER SAFETY, AND FALL PROTECTION. IT IS THE CONTRACTOR'S Z z RESPONSIBILITY TO COMPLY WITH ALL APPLICABLE REQUIREMENTS. w�0¢3¢LYi° ab Io ¢ III DRAWING NO. S1.1 19-139 ig 2 ) 3 i 4� 5 Iv 74r zed >Td - 'I - 17-M 10'---y0.�______--___1- - _ D q! —DROP FDN WALLA WINDOWS. TYP (COORD wl ARCHL DINGS) A 4' 1. -- - - - - --- - A - --- s - - ----- -- - -------------------- ---------------------------------- r � I r- ---- -- - - S22 r+ — Z? J 1 r-- -- ----- ---- —i B------------------------------------- -1 ----- - --^--- L-r----- ---- ---� -i------------------ ----------- ; -_- T-6Y' 4'd3/' - B-0/ ' T-101/ I F BEAM POCKETli� 7A' WIDE STRIP (TNG i 6D s, SIM S22 � I '' � i � m i -- - ----- '-- -------- -- '+-----------�----- ----------- -- ----- - - ---- -- 1 - - f 10, 1------------- - --------- ---------- ---------- ---- -- ---- ----- - -------------------- T----------------- 1 j i 15'd'ie �G V. �G �G Gi' �G G I' BP� i a F f i i S2.z I 1 1 B Szz r 1 i —510 F11L1 HEIGiRi BASEMENT �-- I 4' EIGHT SLAB wI 6X6-W1.4XW1.4WWF i Jv , — 7-0-"-0'X72' FTNG COORD DIMS wl 1 I I 1 i BULKHEAD MFGR I j 1 � A i i i \...� IV SAW CUT SLAB SAME DAY ASS''. I 1 POUR STOP W WF 0 JOINTS SEAL , S2.2 i 1 i @ 28 DAYS (TYP) 1 C ' G ' — --+ S2.2��, S2.2 i i 52.2 ' _-______J ____I I 1 ______—_____ __________ _—____—_______—___.________--_ ___ F _______________________________ _ _______i_____ -------- -- ------ _—_ i_______________ ___ ______ ________ _______-------------------------- i -- _________ - JQ JQ Af 9-0Y' D 17' O SONOTUBE W 7-TO SZ.Z FTNG i, - r ----------------------- FOUNDATION PLAN SCALE: 114" -1'-(r NOTES: 1. FOR GENERAL NOTES SEE S1.1. 2. FINAL DIMENSIONAL CONTROL REMAINS WITH THE ARCHITECT,CONTRACTOR TO COORDINATE WITH FINAL ARCHITECTURAL PLANS. 3. STEEL COLUMNS TO ALIGN WITH CENTERLINE OF BEAM ABOVE AND FIT IN WALL, COORDINATE WITH FINAL ARCHITECTURAL PLANS. 4. LOCATE FOUNDATION ELEMENTS PER APPROVED CMLISITE PLANS 5. FOR TOP OF CONCRETE ELEVATIONS REFER TO CIVIL SITE DRAWINGS AND COORDINATE WITH THE ARCHITECT. S. COORDINATE LOCATION OF FOOTINGS AND COLUMNS WITH ARCHITECTURAL PLANS SO THAT COLUMNS AND POSTS ALIGN. V �0a V c� m C' o d 7 E J9 cc d cc cc N _ In. p v 0 a Z J a Z O Z D O J J Z ^oTy� W uj N W W W C Z N= � U W W u) oF� O ZW^ UA > to ` �1 :C � -8I"LL T m m R W fnmNwLL .. d� . ¢ Yy L7 w S DRAWING NO. S2.1 19-139 - CONT (2) 2X6 PT SILL NOTES: EXCAVATION ---, LIMIT 1. FOR CONCRETE STRENGTH AND PRESUMPTIVE SOIL BEARING PRESSURE, SEE GENERAL NOTES. GRADE - i 2. FOR BASEMENT FOUNDATION, PROVIDE CONTINUOUS - LVL OR WOOD BEAM .+� PERIMETER DRAIN TO PREVENT ACCUMULATION OF GROUND (2) #4 CONT TOP WATER. �- & CORNER BARS, -/, NOTE 3 --y T LAP 24" MIN 3. SEE ARCHITECTURAL DRAWINGS FOR DAMP ROOFING, , INSULATION, AND PERIMETER DRAIN DETAILS. ��� �\ 4. DO NOT PLACE UNBALANCED BACKFILL ALONG _MATCHING i\ DOWELS FOUNDATION WALLS UNTIL FLOOR SLAB, SILL ANCHORS, AND LCC COLUMN CAP OR EQUAL (1)#4 CONT —,, FIRST FLOOR FRAMING AND SHEATHING ARE IN PLACE. �C & CORNER BARS - g ® MK) SPAN, 2 5. FOR BASEMENT FOUNDATION, BACKFILL MATERIAL SHALL LAP 24' MIN 4 BE FREE DRAINING SAND AND GRAVEL; COMPACT BACKF&L IN 12' LIFTS; DO NOT USE UNSUITABLE EXCAVATED MATERIAL CONCRETE FILLED LALLY BACKFILL FOR BACKFILL OR 70 STANDARD SCHEDULE 40 WEK,'HT STEEL PIPE 6. IF LEDGE IS ENCOUNTERED ABOVE MINIMUM FROST DEPTH, COLUMN (SEE FRAMING PLANS) 7 ' PIN FOUNDATION WALL TO LEDGE WITH #4 DRILLED AND EPDXY -GROUTED BARS AT 4'-0' OC, EMBED 14' — V COLUMN BASE PLATE BASEMENTSLAB �P)/ SIZE TO SUIT a - i 7. FOUNDATION WALL THICKNESS: V �� wl (2) A307 ANCHOR BOLTS O ' INSITU SOIL WALL THICKNESS W EMBEDMENT SAND AND GRAVEL 10' _ o4=r; �cv SILTANDCLAY •17 FOR UNBALANCED FILL 7'-0* OR LESS, WALL THICKNESS MAY (2)1A4� BE REDUCED T010' "1.- ' -� bl &. SILL CONNECTIONS: E ANCHOR BOLTS: SEE GENERAL NOTES i FOUNDATION (3) R4 EW BOTT j ) % ANCHOR SPACING: 4'-0' OC EXCEPT: 6' TO 12' FROM EACH CORNER _PLAN _ iA W TO 2"FROM EACH END OF SILL PLATES r-0' ' `#4�46 TYPICAL FOUNDATION WALL INTERIOR LALLY COLUMN SECTION A SECTION B SCALE: 1/2":l'-W $2.1 SCALE: 1n"=T-0" 52.1 BUILDING TAR PAPER TO PROTECT BEAM PT BLOCKING (EACH SIDE) PROVIDE HANDRAIL / / FIRST FLOOR JOISTS (SEE PLAN) O 0 NF0UNDAT11ON WOOD FRAMED BEAM STAIRS (P.T.) RISE FOR ADDITIONALAND RUN TO PT OSTS EILL WACH SIDµE EAM HOR FOUNDATION WALLMEET CODEINFORMATION SEE ADD (2) #4 BARS Q POCKET FOUNDATION PLAN AND SECTIONS 3 Yz' MIN BEARING DEPTH FOR ADOL INFO SEE SECT AI - BULKHEAD DROPPED i BEAM POCKET SECTION E SECTION F SCALE:1/2"=1'-T 52.1 SCALE:314"a1'4T' 52.1 MIN. 2A.B. PER PLATE LENGTH I' P.T. SILL -- _ ��.. AtLG-�V q 36 BAR PLATE WASHER SQl� 3 DIA LAP ON TOP OF �� 7 *Ail &}jam, UPPER PT SILL J J. � EA. AB. (TYP"� ANCHOR BOLT Ci MAXIMUM SLOPE 3 / - WHERE OCCURS, --•� �� ` HOLD-DOWNS FOR �> I WALL BRACING, 1 { SEE WALL BRACING TOP OF 1 1 PLANS, NOTES & -- ALL TYPICAL ANCHORS WALL FOOTING - DETAILS TO BE SPACED 12' FROM CORNERS AND 4'-0' O.C. (UNO) DEPTH - i OF FOOTING - (MIN) ANCHOR BOLT DIAGRAM STEPPED FOOTING DETAIL SECTION SCALE:NTS SCALE:NTS ADD BLOCKING AT CONNECTIONS (TYP) CONT SIL PLATE ' w/ANCHOR BOLTS SEE SECTAI S22 A- , -SHEATHING AT EACH JOIST BEYOND - 2X CONT LEDGER FOUNDATION WALL TYPICAL DECK / PORCH LEDGER SECTION C BCALE:NTS S2.1 WF (SEE FRAMING PLAN) I '_ PLY¢5(TOSUIT wl(2)Yz DIA A307 BOLTS -e-- R3B) i- HSS POST !� (SEE FRAMING PLAN) ADDED (2) 04 VERT BARS -, PL )¢ TO SUIT w/ (4) V DIA a POST LOC TITEN HD w/ 53i'a' MIN EMBED \ ON V MIN GROUT STEEL COLUMNS @ FOUNDATION WALL SECTION G SCALE : 3/4" a 1'-0" 52.1 CONT PT SILL ANCHOR BOLT— (TYP) (3) PT HEADER PT2XJAMB#ONG rn POSTS & SILL PLATE H (1)#4 EACH SIDE_.. .•' __ OF OPENING__- li ADDL(2)#4 CED SEE ARCH 1'-Y CONCREINFORWALL DWGS i MIR) --i FOUNDATION WALL WINDOW OPENING DETAIL SCALE:NTS NOTES: 1. THE LEDGER SHALL BE INSTALLED TIGHT TO WALL SHEATHING, WITHOUT SPACERS. 2. SEE ARCHITECTURAL DRAWINGS FOR FLASHING DETAILS AND STERDOWN DIMENSION 3. LAG BOLTS SHALL BE )V 0 BY 6' LONG WITH WASHER MACHINE BOLTS SHALL BE )V 0 BY LENGTH TO SUIT WITH 2 WASHERS; REFER TO GENERAL NOTES FOR CORROSION PROTECTION. 4. LAG BOLT ORftL44OLE DIAMETERS: SHANK (THROUGH LEDGER BOARDk ye LEAD (THROUGH RIM JOIST): �e S. LAG BOLT SPACING: MAX JOIST SPAN LAG BOLT SPACING 6 R 15' O.C. 6 It 12' O.C. loft 9' O.C. 12ft 6'O.C. 6. MACHINE BOLT SPACING: MAX. JOIST SPAN BOLT SPACING 10 ft 16, O.C. 12ft 12'O.C. 7. LEDGERLCK RIM JOIST FASTENERS MAY BE SUBSTITUTED FOR THE SPECIFIED LAG BOLT. O0a O r= w ♦ ♦ -- ANCHOR BOLT GRADE \ -- HO GALV. SIMPSON ANCHOR FOR DECK POST --- 170 CONC PIER (2) #4 21 #3 TIES Q 2 PLACES r-010 NONCOMPRESSNE STABLE IFI� UNDISTURBED SOIL OR STRU COMPACTED (>95%) FILL OVER DECK POST PIER FOOTING SAME SECTION D SCALE: 314" a V-0" 52.1 i 10 C M C 10 C C a Y�E L ca ccND a� 0 d .O L. a r� Z 0 V W N Wa OW 0 Z m O LL J J ro Z ;:u, Q N W IIIYYYYY LLl E N� X W w 0) 0 ys p 1­ m m R a L xC 7 O�yyJUIQ ♦x NF LL S m in m o LOUO N Om m 0 W W .. V zOCZ¢ Y'0_ L ab (aQ W O O U DRAWING NO. S2.2 19-139 1 2 3 4I i 5 11 FIRST FLOOR FRAMING PLAN SCALE: 1/4" 01'-0" NOTES: 1. FOR GENERAL NOTES SEE S1.1. 2. ALL POSTS SHALL BE: AS NOTED. 3. INDICATES BEARING WALL BELOW. 4. ALL WINDOW HEADERS 4'-0 OR LESS TO BE (2) 2X101N 2X4 STUD WALLS OR (3) ZX8 IN 2X8 STUD WALLS, UNLESS OTHERWISE NOTED. 5. ALL FLOOR JOISTS: 14' TJI 360 @ 18' O.C. (UNO) 8. ALL DECK JOISTS: 2X8 PT Q 18' O.C. (UNO) 7. REFER TO SIMPSON DECK CONNECTION AND FASTENING GUIDE FOR CODE COMPLIANT INSTALLATIONS. 8. FLOOR JOISTS MAY REQUIRE STRENGTHENING WITHIN LRAT'S OF HEAVY COUNTERTOPS (COORD. WITH ENGINEER) 9. COORDINATE ALL POST MATERIALS 8 SIZES WITH BEAMS ABOVE, PROVIDE SOLID BLOCKING 0 FLOOR LEVEL (TYP) 10. FOR ALL FIREPROOFING REQUIREMENTS COORDINATE WITH THE ARCHITECT. JS Y� C CC v r GC (L o cc cc d cc N �a— d O a C7 z a LLz O_3 Oa J U. I-- N U J rD J Z to NF W I W Z N7 x Z w<,!gm W Q y N rz o cc W LL ^ C % LL E �NHLL of m m R w m_ m w_ w a w n 1¢ 3¢ 0 w ga S O O In U DRAWING NO. S3.1 19-139 NOTES: 1. FOR GENERAL NOTES SEE 81.1. 2. ALL POSTS SHALL BE: AS NOTED 3. = INDICATES BEARING WALL BELOW. 4. ALL WINDOW HEADERS 4-0 OR LESS TO BE (2) 2X10 IN 2X4 STUD WALLS OR (3) 2X81N 2X6 STUD WALLS, UNLESS OTHERWISE NOTED. 5. ALL FLOOR JOISTS: 14" TJI 230 @ 16' O.C. (UNO) 6. ALL CEILING JOISTS: 2X8 @ 16" O.C. (UNO) 7. COORDINATE ALL POST MATERIALS & SIZES WITH BEAMS ABOVE SECOND FLOOR FRAMING PLAN SCALE: 1/4" a T-0" O C CCQ � C .O t a�EE a� N o c �a� O a` a z OJ -j [L U. oz o2 a Cl) LLLL v J J So Ny W t Z y7 W ¢2.p � pt-mm w mLL �CC i IOtJ%� 4's wpm ro m N w N m w LLI z ¢ z ¢ Y C 'Bmm a w w ¢ x ❑ O O U DRAWING NO. S3.2 19-139 1� B C /E - F — SEE S3.3 FOR POSTS 6 BEAMS BELOW --_ _ _ a eEnMs eEltiw CEILING / LOW ROOF FRAMING PLAN SCALE: 11V z l'-0" — SEE S3.3 FOR POSTS & BEAMS BELOW NOTES: 1. FOR GENERAL NOTES BEE S1.1. 2. ALL POSTS SHALL BF -'AS NOTED. 3. = INDICATES BEARING WALL BELOW. 4. ALL WINDOW HEADERS 4'-0 OR LESS TO BE (2) 2X10 IN 2X4 STUD WALLS OR (3) 2X81N 2X6 STUD WALLS, UNLESS OTHERWISE NOTED. S. ALL CEILING JOISTS: 2X10 @ 16' O.C. (UNO) 6. ALL LOW ROOF RAFTERS: 2X8 @ 16' O.C. (UNO) 7. COORDINATE ALL POST MATERIALS d SIZES WITH BEAMS ABOVE (T7'P) 10 =CC Ca 'oc2 .o .c ca W d CC N a� N .O L a LL 0 00C a �a 00 J Z Z J LL W ci -J J J � Z �o NF W IN W C Z U) U O Ni p!W-com w LL�CC > to�:ix rz ;! 8 LL s gj W tO m N W LL v d Z Q 3 a v a O O G U DRAWING NO. S3.3 19-139 F ROOF FRAMING PLAN SCALE: 114" a l'-0" NOTES: 1. FOR GENERAL NOTES SEE S1.1. 2. ALL POSTS SHALL BE: AS NOTED 3. ALL RAFTERS: 2X12 @16' O.C. OF 4. r= INDICATES BEARING WALL BELOW. a 2 U 5. ALL WINDOW HEADERS 4'-0 OR LESS TO BE (2) 2X10 IN 2X4 STUD rn WALLS OR (3) 2X8 IN 2X6 STUD WALLS, UNLESS OTHERWISE p NOTED. lU 6. RAFTER SIZE IS MIN ALLOWABLE FOR STRUCTURAL DESIGN. MAY NEED UPSIZING FOR INSULATION REQUIREMENTS. COORD. wl Q ARCH. 0 T. COORDINATE ALL RIDGE HEIGHTS, ROOF PITCHES, AND ROOF t 4 J 5% Z LINES WITH ARCHITECTURAL DRAWINGS. 8. COORDINATE ALL POST MATERIALS 8 SIZES WITH BEAMS ABOVE. Q �?a�3Ei TS c MYC13 l+ C C � •O O a a�EE dmoo p a O a` a z a J a 0 z a a� u- U. 0 0 V J J g Z �o W H W Z N- S W Wy�r,f, U1 o y2 N P a0 w RW 7U. U. W � yt-LL rn m m g W V) m N W 0 O 0 U LL wA T3¢sei° o DRAWING NO. S3.4 19439 D -- F, B c wE \ — F WALL BRACING NOTES: a 1. ALL EXTERIOR WALLS, INCLUDING THOSE NOT IDENTIFIED AS WALL BRACING U PANELS, SHALL BE CONTINUOUSLY SHEATHED WITH PLYWOOD PANELS AS SPECIFIED IN THE GENERAL NOTES. cn 0 2. OINDICATES LIMITS OF WALL BRACING PANELS (SHEAR WALLS) WITH HOLD-DOWN ASSEMBLIES AND LOCATIONS AS INDICATED W H 3. 2ND ROOK HOLD-DOWNS ABOVE 1ST BOOR WALLS SHALL CONNECT THE BOTTOM 0 OF 2ND FLOOR BUILT-UP STUDS TO THE TOP OF 1ST FLOOR BUILT UP STUDS USING THE SPECIFIED HOLD-DOWN ASSEMBLY Z 4. 1ST FLOOR HOLD-DOWNS ABOVE FOUNDATION WALLS SHALL CONNECT THE 0 BOTTOM OF 1ST FLOOR BUILT-UP STUDS TO THE TOP OF THE FOUNDATION WALL VIA U THE INDICATED HOLD-DOWNS AND ANCHOR BOLT ASSEMBLIES Q 5- 1ST FLOOR HOLD-DOWNS ABOVE INTERIOR BEAMS SHALL CONNECT THE BOTTOM OF 1ST FLOOR BUILT-UP STUDS TO THE FLOOR BEAMS USING THE INDICATED � aU- HOLD-DOWN AND BEAM ANCHORAGE DETAIL d4'p �y n 6. PROVIDE STUDS AND/OR FULL -DEPTH BLOCKING ALONG ALL VERTICAL AND LL HORIZONTAL PLYWOOD EDGES AT ALL WALL BRACING PANELS u b 7. AT SPECIFIED HOLD-DOWN LOCATIONS, PROVIDE THE MINIMUM NUMBER OF �Q' FULL -HEIGHT STUDS OR EQUIVALENT PSL AS SCHEDULED BELOW 8. AT SPECIFIED HOLD-DOWN LOCATIONS, THE THREADED ROD SIZE FOR CONNECTIONS BETWEEN HOLD-DOWNS SHALL BE AS SCHEDULED BELOW 9. ALL WALL BRACING PANELS SHALL BE CONTINUOUSLY SHEATHED ON ONE (EXTERIOR) FACE OR TWO (INTERIOR AND EXTERIOR) FACES AS SCHEDULED BELOW; PLYWOOD EDGES SHALL BE STAGGERED AT TWO-SIDED INSTALLATIONS 10. GYPSUM WALL BOARD (GWB) SHALL BE CONTINUOUSLY SHEATHED AND STAGGERED, ON 2X STUDS AT Ir OC MAXIMUM SPACING. FASTEN GWB IN ACCORDANCE WITH WALL BRACING SCHEDULE BELOW. SEE ARCHITECTURAL Q% Cc DRAWINGS FOR GWB TYPE AND THICKNESS PER SCHEDULE(V MINIMUM). 0 Q 11. ALL WALL BRACING PANELS SHALL BE EDGE NAILED PER THE SCHEDULE BELOW c 12. REFER TO SIMPSON CATALOG FOR ADDITIONAL INSTALLATION DETAILS AND V C REQUIREMENTS N •O •N SHEATHING SCHEDULE: _J a O WALLTYPE SHEATHING EDGE FASTENER SPACING L SW-1 ONE FACE 6' DC a% 3 SW-2 ONE FACE 4.00 J9 (c SW-3 TWO FACES 61OC L. =n 0 SWA TWO FACES 4'OC A N HOLD-DOWN FULL -HEIGHT STUDS AND CONNECTING RODS CL C HOLD-DOWN FULL -HEIGHT STUDS (MIN) THREADED ROD DIA ~ 2 FIRST FLOOR WALL BRACING HDU2SDS2.5 2 sm *' SCALE: 1/4" z V-0" HDU4-SD82.5 2 5/r HDU"DS2.5 2 SW G HDUS-SDS2S 3 Wr L HDUIISDS2.5 4 1' a CAST -IN HOLD-DOWN ANCHOR BOLT S N HOLD-DOWN ANCHOR (MIN EMBEDMENT) Q ( (, 5 1 HDU2SDS2.5 SST816 (12-) a'i gal � HDussoszs16( IL 1 'HDUS-SDS2.5 SSTS28 (24-) HDU1"DS2.5 SSTB28 (24-) Z DRILLED4N HOLD-DOWN ANCHOR BOLTS j HOLD-DOWN ANCHOR (MIN EMBEDMENT) Q HDU2SCS2.5 117 DIA SET EPDXY(S-) m HOU4SDS2.5 5/8• DIA SET EPDXY (10-) HDU5SOS2.5 5/8' DIA SET EPDXY (1Z-) J HDUB-SDS2.5 7/8' DIA SET EPDXY (15-) J HOUI ISDS2.5 7/r DIA SET EPDXY (18-) NOTE: FOR INTERIOR HOLD-DOWNS ABOVE LVL AND STEEL BEAMS, SEE FIRST FLOOR FRAMING PLAN FOR CONNECTION. V J J Z o � N jy- Z N fLL=-1 _ qp� Z W6�{N W ¢vNiw o y� O i p�1em LU LLaCC > m J xq SECOND FLOOR WALL BRACING SCALE: 1/4" =1'-0" cE LLJ uj L � z ¢ 3 ¢ 0 w i ] 0 O U DRAWING NO. S4.1 HORIZONTAL PANEL EDGE (NOTE 2) - Z of ¢ 1'J' MIN. w/ (4)8d = COMMON NAILS TO _ a EA STUD O FLOOR LEVEL NOTES: 1. SEE GENERAL NOTES AND WALL BRACING SCHEDULE FOR ADDITIONAL NAILING REQUIREMENTS 2. PROVIDE 2X BLOCKING AT WALL BRACING PANELS - SEE BRACING PLAN AND SCHEDULE. TYPICAL WALL PANEL DETAIL SCALE: N.T.S. r 5/e FITTED STIFFERNERS E.S. OF COLUMN WEB e - �3 EDGES, TYP, � I i� /-lv- (TYP-TSB FLANGE) 1' / 94e�(MIN) i WF BEAM i FITTED STIFFENERS E.S. '3 EDGES (TYP) (4) %* 307 -� THREADED ROD CAST IN PLACE wIPLATE WASHERS & DBL NUTS IN CONCRETE w7—I TACK WELD------ WF COL BASE PLATE (SEE DETAIL ON THIS SHEET) CONTINUOUS FOUNDATION WALL MOMENT FRAME - SINGLE STORY SECTION SCALE: 314" :1'-T ADDITIONAL JOIST AT WALL BELOW LIB % GAP FOR STRAPPING SIMPSON RBC @ 18' O.C. (JOIST TO PLATE) TYPICAL INTERIOR SHEAR WALL PARALLEL TO JOISTS PROVIDE SOLD BLOCKING SIMPSON RBC @ 1T O.C. (BLOCKING TO PLATE) CONT RIDGE VET IF READ t OF SHEATHING RAFTERS-- \ SIMPSON SLOPED HANGERS 1 JOINT OR ROOFSHEATHING �� 2X BLOCKING _ _ ..3' IN.) SIMPSON LSTA ------- STRAP TIE --- STEEL STRAP @ 16.O.C. TJI JOISTS @ IT O.C. j i SIMPSON FACE MOUNT @ EACH RAFTER LVL BEAM WITH POSTS @---�_. . " GABLE ENDS AND PROVIDE )_ -" OR —COLLAR TIES @ 18. O.C. (SEE FRAMING PLAN) �, i - HANGER `., INTERMEDIATE POSTS WHERE ` INDICATED PROVIDE SOLID BLOCKING @ JOIST ENDS d, \��� — yz'g CARRIAGE BOLTS or LEDGER LOKS (TO SUIT RAFTERS it -- RAFTERS wl BIRDSMOUTH CUT • ♦ ; 4 • ♦ ♦ (PER MANUF. REQMTS) % WIDTH OF BEAM) SIMPSON LSU26 —� '_- SIII A23 • • @ IT O.C. STAGGER SP. POSTS BEYOND LVL BEAM j MULTIPLE LVL (SEE FRAMING PLANS) TYPICAL RIDGE SECTION SCALE:NTS NO PLY JOINT ................. ,.., ,� 1'-O' MAX SEE ARCH FLOOR JOIST DINGS. PLYWOOD SHEATHING (TYP) TYPICAL INTERIOR SHEAR WALL PERPENDICULAR TO JOISTS SECTION SCALE:NTS PSL POST HDU COT 2X PLATE wl V DIA BOLTS @ lT OC (STAGGERED) BEAM t HOLES FOR WOOD PADDING (SEE TYPICAL FLUSH FRAMED DETAIL) TYPICAL PSL POST AND HDU ABOVE WF BEAM SECTION SCALE: NTS TYPICAL GABLE WALL RAKE SECTION SCALE:NTS 2X TOP PLATE (2) SIMPSON SDWC @ 1W O.C. a H2.5A@ ITO.C. 8d COMMON SHEATHING NAILS 04'O.C. j DINGS. ROOF RAFTER ., VENT NOTCH 2X BLOCKING FLOORJOISTS S \\' = RIM JOIST SIMPSON H2A @ ALL RAFTER ENDS (H7Z @ ALL CORNERS) TYPICAL EAVE DETAIL AT FLOOR DECK SECTION SCALE: NTS TYPICAL FLUSH FRAMED LVL & TJI JOISTS SECTION SCALE: NTS TJI JOISTS @ IT O.C. — (SEE FRAMING PLAN) PROVIDE SOLID BLOCKING ABOVE LVL BEAM (PER MANUF. REQ'MNTS) MULTIPLE LVL — (SEE FRAMING PLANS) TYPICAL DROPPED LVL & TJI JOISTS SECTION SCALE:NTS SPLICE CONN. PER MANUF. REOMTS LEDGER LOKS @ 18' O.C. STAGGER SP. LEDGER LLO SE(TO SUIT WIDTH OF BEAM) @ 18' O.C. STAGGER SP. ROOF RAFTER VENT NOTCH 2x BLOCKING -_ �•� TOPPLATES --------- + (DBL ROW NAILING) A + Z i CEILING TIES I CEILING TIEIRAFTER F- NAILING PER CODE SEE ARCH. DINGS. SIMPSON H2A @ ALL RAFTER ENDS (H7Z @ ALL CORNERS) TYPICAL EAVE DETAIL AT CEILING TIES SECTION SCALE:NTS 2X LET4N LEDGER wl TIMBER LOKS @ IT O.C. �n STAGGER SP. BASE PLATE - W12 w/ WOW SIMPSON SLOPED HANGER—� °,¢'XB'X1'-8' '.� PADDING, /. wl (4) % DIA FIT WITHIN WALL \ ROOF RAFTER —... ANCHOR BOLTS II CONSTRUCTION. \ \ CWRD w/ARCH FOR ROOF PITCH REFER TO VET NOTCH ARCH. DINGS. -.._ / 2x BLOCKING t---I �- 10 - LOW ROOF RAFTERS — TOP PLATES (DBL ROW NAILING) j RAFTER TOP/PLATE SEE NAILING PER CODE ARCH �l _ - _oRCH IPSO SIMPSON RAFTER ENDS(H7Z MULTIPLE PLY BEAM (SEE FRAMING PLAN) MULTIPLE ALL CORNERS) 1' 3- SIMPSON POST CAP (TO SUIT) i PSL PLUS POST (SEE FRAMING PLAN) BASE PLATE TYPICAL LEDGER CONNECTION AT TYPICAL EAVE DETAIL AT CATHEDRAL CEILING PORCH RAFTERS & CEILING JOISTS DETAIL SECTION SECTION SCALE: 1"at'-T SCALE:NTS SCALE:NTS TYPICAL GAMBREL ROOF PITCH CONNECTION SECTION SCALE: NTS H2.5A RAI TO PLATE p� H2.5A PLATE. — OPTION C C TO STUD (( STUD RAFTER L r TYPICAL HURRICANE TIE (A � t► INSTALLATION AT EACH RAFTER a O DETAIL E SCALE:NTS L R.O. (SEE ARCH DWGS,-TYP) �u W w O rc —PSL POST (TYP) SEE FRAMING PLANS WF BEAM IN MF WOOD WIND FRAME (SINGLE SPAN) SECTION SCALE: NTS 0) L .219 cc 16. SEE FRAMING PLAN FOR N HEADER SIZE LEOGERLOS @ 12' OC STAGGER SPACING (TYP) A O L a (2) SIMPSON N LCE4 CONN (1) EACH SIDE O ca W J I.- (9 W Z_� - HDU-2ATTACHED TO POST PER DETAIL ON THIS SHEET LL :i J rD J � Z •' � N fn W F� Z D S ULu U) tZ o OR N� to a .1 wU LL J, } y rn m m N W CA m y W l w ¢ 3cr L) DRAWING NO. S5.1 19-139 LEVEL STABLE BASE THAT , COMPACTED AND ONTO WH CRUSHED STONE HAS BEET UNEVEN SETTLING (310 C& C6 P `PROPOSED WELL 1 ItE 2) , 77 ikl 12 ... 5:- Q CURRENT MAPPED LIMIT OF ZONE AE ZONE AE, EL. 12 (REFER TO LOMA FILING CASE NO. 19-01-12674) 3) PLAN BK. 178, PG. 17 w co 0 0 m 0 m 0 -o 0 o TER_ I r � I I � C OPEN wA TER p0N N 81'02'36"IL:: 33. 30E 1 8.51 PERIODICALLY SUBMERGED AREA mI: PLAT 11 LOT 32 N/F TEAL POND NOMINEE TRUST PARKS E ROAD UARTMOUTH i NEIW DOW INT lin RM W PREPARED SITE 'i RMUTM OFF �OF o� OF I COMWNIl NIOLTLTH EGEND I • DH/FU DRILL HOLE/FOUND REC _ � -� — LIMIT OF WETLAND (RECORDED AT B.C. REGISTRY Of DEEDS) tRVG A p� a00000eo� STONEWALL (TYP.) 1) PLAN IRK. 46. PG. 32. l 2) PLAN BK. 83. PG. 113 J 3) PLAN BK. 178, PG. 17 V SITE LOCUS D_ARTMOUTH PANNING BOARD SCALE: 1-2000' APPROVAL UNDER SUBDIVIWN CONTROL LAW NOT REQUIRED MISHAUM (PRNATE) POINT N 81.0236• w 6H/FD -- N 1SSC76• E - (496.3V TO ANG. IT.) 33.01' "n) E 118.1d i ; OH/FD 201.00• _ - S �� (HELD LOT UNE 11.11") _ { a - .� N N Or34.43• E ROAD 1g' 631• MANrD NCE BUILDINGS (TO BE RELOCATED). g emir w - { �ra�ilrrePLARM BOW 33s1• - FAIN VE 04RIAOM11T 2OMAC BY-LOS MAR AS%RE W ANY LOr CREATED AEMv � t (� s eLALa4eLE:• \ I LOCDS PLAT 11. LOT 33 PUT tt LOT 32 OF RECORD, LOT 3 s_ LOT 2 LOT 1 TEAL POND "NO�uwEE TM P�ALt�R WISIut PArtn+E1mBP AREA. 106.400 %Tt (LOLL' �=�' .,` m 303 POPE ROAD ( ) :° •. ,-. _ .MEk_t49.000_ hDDlj•-�. AREA 144A00 SFTt (TDT CONCORD. MA 01742 _ 135AM SFr* CID ORS. N HAJ F_.. 9Q60o ;cTt e z u.. DEE1Y.> 2871 PG Y29 PLAT 11 FFONTACE 2DiDO',4 - 97,040 SfT* (UPLAND) 64 LOT 34 : eeo sTt (t,PLAwJ'' J N/F FRONTAGE 296.11' FRONTADE214.41' \ I KERN M6NAUMJIM A. 01 - 04 w IGl REG 15 4 DATE 1i () %K`oi WA l 01 Nm- 1. THE LIMIT OF WMAND WAS DELINEATED BY DAVID PICHETTE, WETLAND SCIENTIST, 94 OCT. k NOV, 2017. SEE WETLAND SITE INSPECTION (FORM A-t) ISSUED BY THE DARTMOUTH CONSERVATION COMMISSION DATED 11/20/17. 2. TOTAL AREA OF PLAT 11. LOT 33 (TO THE EDGE OF OPEN WATER - SALT POND) AS SHOWN ON THIS PUN IS 9.2 h +/- . - 40 0 20 40 so SCALE IN FEET ti}pF1 p} i PERIODICALLY � 5 / / / 9"`_ ESE pF SUBMERGED AREA =' APPROVAL NOT REQUIRED PLAN DRAWN fat WATER PARKER MISHAUM PARTNERSHIP _S Dss612 w t96_9o' _._. -- — (5 I -� pFgft� .� (TIDAL) SPA- ph ND i MISHAUM POINT ROAD �H�, ,/ DARTMOUTH, MASSACHUSETTS SCALE: 1 "=40' DATE: APRIL 5, 2019 SALTER'S PONT - /19 IMPROVEMENT ASSO60001 DRAWN BY Boucher & A7s�sociates. Inc. �Atioro ; / LAND SURVEYORS 7 \ CONSULTANT RECEIVED J 648 AMERICAN LEGION HIGHWAY WESTPORT, MASSACHUSETTS 02790 MAY E 6 2019 (508) 636-5905 cOW-uvanoxco:a\msswx COPYRIGM® 2019 BOUCHER k ASSOCIATES, INC. 11LE 3- 1-AN . rg