Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BP-78572
ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER —CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY —RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN l EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET —BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART, 250,17, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). , MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING P01 POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE - `- SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS.' S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT ,h� �) r ` PV1 COVER SHEET . v PV2 SITE PLAN - 7, 7PV3 STRUCTURAL VIEWS �k p PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES r y 4 PV5 THREE LINE DIAGRAM Cutsheets Attached 1. ALL WORK TO BE DONE TO THE 8TH EDITION L X } GEN #168572 s ELEC 1136 MR OF THE MA STATE BUILDING CODE. t•� ..��: �... 2. ALL ELECTRICAL WORK SHALL COMPLY WITH t x + P THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. f � r MODULE GROUNDING METHOD: ZEP SOLAR _ A. AHJ: Dartmouth <~nl? $ REV BY DATE COMMENTS 75 �s IO x - 4'a REV A NAME DATE COMMENTS 4 A. UTILITY: NSTAR Electric (Commonwealth Electric) £ ♦ ���'' PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINEDTAINEDFIDENTSHALL NOT BE USED FOR THE CON THE INFORMATION HEREIN Ioe NUMBER: J B-0272491 00 MAGAN CARL MAGAN RESIDENCE Trey CarrierBEN NOR FITSHALL OF ANYONE EXCEPT IN WHOLE INC., MOUNTING SYSTEM: 343 ROCK O'DUNDEE RD 4.68 KW PV ARRAY 'i,SolarCity. NOR SHALL IT BE DISCLOSED IN WHOLE T' IN Comp Mount Type C PART IZ OTHERS OUTSIDE THE RECIPIENT'S MODULES: DARTMOUTH MA 02748 ORGANIZATION, EXCEPT IN CONNEC11ON WITH , THE SALE AND USE OF THE RESPECTIVE (18) TRINA SOLAR # TSM-260PD05.18 * 24 St. Martin Drive, Building 2, Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN APN: PAGE NAME: SHEET -REV: DATE: Marlborough, MA 01752 PERMISSION OF SOLARgTY INC. INVERTER' T. (650) 638-1028 F. (650) 638-1029 SOLAREDGE SE5000A—USOOOSNR2 (508) 996-2277 COVER SHEET PV 8/21/2015 (ea6)-soL-an (765-2489) www.sdarcity.aam PITCH: 25 ARRAY PITCH:25 MP1 AZIMUTH:202 ARRAY AZIMUTH:202 MATERIAL: Comp Shingle STORY. 1 S, (E) DRIVEW/ 343 Rock O'Du CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: J B-0 2 7 2 49 1 00 CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE MODULES (18) TRINA SOLAR # TSM-260PD05.18 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PERMISSION OF SOLARCITY INC. SOLAREDGE #SE5000A—USOOOSNR2 _ REMISE OWNER: MAGAN, CARL 343 ROCK O'DUNDEE RD DARTMOUTH, MA 02748 (508) 996-2277 DESCRIPTION: MAGAN RESIDENCE 4.68 KW PV ARRAY PAGE NAME SITE PLAN i Fr,FNn (E) UTILITY METER & WARNING LABEL INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS DC I DC DISCONNECT & WARNING LABELS AC DISCONNECT & WARNING LABELS O DC JUNCTION/COMBINER BOX & LABELS DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS O DEDICATED PV SYSTEM METER Q STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR -- CONDUIT RUN ON INTERIOR GATE/FENCE Q HEAT PRODUCING VENTS ARE RED � � _ 11 1 INTERIOR EQUIPMENT IS DASHED L _"J SITE PLAN N 11an Scale: 1/8" = 1' W 7'00' 0 V O' 16' S Trey Carrier SHEEP. REV: DATE PV 2 8/21 /2015 ° v.SolarCity 24 St. Martin Drive, Building 2, Unit 11 Marlborough, MA 01752 T: (650) 638-1028 F: (650) 638-1029 (888)—SOL—CITY (765-2489) www.solarcity.com CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. (E) 2x4 CASIDE VIEW OF MP1 NTS )� MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER I NOTES LANDSCAPE 72" 24" STAGGERED PORTRAIT 48" 20" RAFTER C.J. " 2x6 @ 24 OC 2x4 @24" OC STORIES: 1 ARRAY AZI 202 PITCH 25 Comp Shingle JOB NUMBER: JB-0272491 00 MOUNTING SYSTEM: Comp Mount Type C TRINA SOLAR # TSM-260PDO5.18 INVERTER: SOLAREDGE #SE5000A—USOOOSNR2 PREMISE OWNER: MAGAN, CARL 343 ROCK O'DUNDEE RD DARTMOUTH, MA 02748 (508) 996-2277 PV MODULE 5/16" BOLT WITH LOCK & FENDER WASHERS ZEP LEVELING FOOT ZEP ARRAY SKIRT ZEP COMP MOUNT C ZEP FLASHING C (E) COMP. SHINGLE (E) ROOF DECKING 5/16" DIA STAINLESS STEEL LAG BOLT WITH SEALING WASHER (2-1/2" EMBED, MIN) (E) RAFTER MAGAN RESIDENCE 4.68 KW PV ARRAY PAGE NAME STRUCTURAL VIEWS INSTALLATION ORDER LOCATE RAFTER, MARK HOLE (1) LOCATION, AND DRILL PILOT HOLE. C2)] SEAL PILOT HOLE WITH POLYURETHANE SEALANT. (3) INSERT FLASHING. (4) PLACE MOUNT. L5)1 INSTALL LAG BOLT WITH SEALING WASHER. C IN LEVELING FOOT WITH BOLT & WASHERS. S1 STANDOFF STAMPED & SIGNED FOR STRUCTURAL ONLY Date: Trey Carrier 06y Jason Toman 3 20:34:09-07'00' SHE9-. REV: DATE PV 3 8/21/2015 ';SOlafCit y 24 St. Martin Drive, Building Z Unit 11 Marlborough, MA 01752 T. (650) 638-1028 F. (650) 638-1029 (888)—SOL—CITY (765-2489) www.solarcity.com e BOND (N) #8 GEC TO TWO (N) GROUND Panel Number: MPU ODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:307141790 Overhead Service Entrance N 125A MAIN SERVICE PANEL N3 10OA/2P MAIN CIRCUIT BREAKER (E) WIRING Voc* = MAX VOC AT MIN TEMP 50I (2)Ground Rod; 5/8' x 8', Copper U(; Ungrounded INV 1 — (1)SOLAREDGE SE5000A—USOOOSNR7 LABEL: A Inverter, 5015, 240V, 97.57.; W Unifed Disco and ZB,RGM,AFCI INV 2 INV 3 �--(!)CUTLER—HAMMER III DG221UR6 A � J Disconnect; 30A, 240Vac, Non —Fusible, NEMA 3R H — (!)CUTLER —HAMMER ! DG030N8 Ground/Neutral it; 30A, General Duty (DG) (I) AWG #10, THWN-2, Black L-L (1) AWG #10, THWN-2, Red (!)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=21 AAC .......-,(! )AWG8,. TFIWN-2,. Green , . EGC/GEC -(! )Conduit. Kit ;.3/4'.EMT CONFIDENTIAL — THE INFORMATION HEREIN ,106 NUMBER: 0 g— 0 2 7 2 4 91 0 0 CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLAWIT INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN MOUNTING SYSTEM: PART TO OTHERS OUTSIDE THE RECIPIENT'S Comp Mount Type C ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: THE SALE AND USE OF THE RESPECTIVE (18) TRINA SOLAR # TSM-260PDO5.18 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN - INVERTER: PERMISSION of SOLARCITY INC. SOLAREDGE #SE5000A—US000SNR2 MAGAN, CARL 343 ROCK O'DUNDEE RD DARTMOUTH, MA 02748 (508) 996-2277 Inverter 1 SOLAREDGE SE5000A—USOOOSNR9 290V ---lN — (18) TRINA SOLAR A TSM-260PDO5.18 PV Module; OW, 236.9W PTC, 40MM, Black Frame, H4, ZEP, 1000V Voc: 38.2 Vpmax: 30.6 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER ELEC 1136 MR )C+ 1 DC+ )G DC- MP 1: 1x18 :GC ------------------ ---------------------- PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN PV (18) SOLAREDGEP300-2NA4AZS D 3:nPowerBox Optimizer, 30OW, H4, DC to DC, ZEP d ( 1) AWG j6, Solid Bare Copper — ( 1) Ground Rod; 5/8' x 8', Copper V) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. 2, ADDITIONAL LECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE (1 (2)AWG 110, PV Wire, 60OV, Black Voc* = 500 VDC Isc = 15 ADC O1 s� � ) AWG /6, Solid Bare Copper EGC Vmp = 350 VDC Imp= 13.2 ADC (1) Conduit Kit;. 3/4' EMT ..................................... vL. Ir uwr. DESIGN: MAGAN RESIDENCE Trey Carrier r(888T)—SOL—CITY 4.68 KW PV ARRAY SolarCity.t. Martin Dmro, Bulding Z Unit 11 PAGE NAME SHEET: REV: DATE: Marlborough, MA 01752 T.THREE LINE DIAGRAM PV 5 8/21/2015 (765-2489) 6 www.solarcity.com Label Location: Per Code: NEC 690.31.G.3 Label Location: (DC) (INV) Per Code: NEC 690.14.C.2 Label Location: (DC) (INV) Per Code: NEC 690.53 Label Location: (DC) (INV) Per Code: NEC 690.5(C) Label Location: (DC) (CB) Per Code: NEC 690.17(4) Label Location: (AC) (POI) Per Code: NEC 690.14.C.2 Label Location: (AC) (POI) Per Code: NEC 690.54 10 AV i= 3 • e Label Location: (AC)(POI) Per Code: NEC 690.17.E Label Location: (POI) Per Code: NEC 690.17.4; NEC 690.54 Label Location: (POI) Per Code: NEC 690.64.13.4 Label Location: (D) (POI) Per Code: NEC 690.64.6.4 Label Location: (POI) Per Code: NEC 690.64.B.7 Label Location: (DC) (INV) Per Code: NEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR ,�,i�!� 3055 Qe , CA 94402 Way San Mateo, F THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED �- � �� T:(650) 638-1028 f:(650) 638-1029 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, Label Set �►� ' (888)-SOL-CITY(765-2489) www.solar(ity.com EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE ®la SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. 4,, +6olarGty ZepSotar x. Zep System for composition shingle roofs QOOMPAT�A �eMPPt�� &LISTED ON zepsolar.com Next -Level PV Mounting Technology Description • PV mounting solution for composition shingle roofs • Works with all Zep Compatible Modules • Auto bonding UL-listed hardware creates structual and electrical bond • Zep System has a UL 1703 Class "A" Fire Rating when installed using modules from any manufacturer certified as "Type 1" or "Type 2" Specifications • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72" and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end -user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. � '�,,,SoiarCity I ZepSotar Components Comp Mount Part No. 850-1382 Listed to UL 2582 & Mounting Block to UL 2703 Ground Zep Part No. 850-1172 Listed to UL 2703 and ETL listed to UL 467 zepsolar.com Next -Level PV Mounting Technology Interlock Leveling Foot Part No. 850-1388 Part No. 850-1397 Listed to UL 2703 Listed to UL 2703 J"Tit � ew-'e- Array Skirt, Grip, End Caps DC Wire Clip Part Nos. 500-0113, Part No. 850-1448 850-1421, 850-1460, Listed UL 1565 850-1467 Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each producL The end -user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. 02 27 15 ZS for Comp Shingle Cutsheel Rev 04.pdf Page: 1 of 2 02 2715 ZS for Comp Shingle Cutsheet Rev 04.pdf Page: 2 of 2 solar SolarEdge Power Optimizer Module Add -On For North America P300 / P350 / P400 PV power optimization at the module -level USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us solar=eet- SolarEdge Power Optimizer Module Add -On for North America P300 / P350 / P400 P300) P350� ;,P400 r 60-celt PV L (for 72-cell PV I (for 96-cell PV modules modules modules) INPUT Rated Input DC Powers...,,, ............................................. 300 ....................................:.............................................. 350 400 W Absolute Maximum Input Voltage (Voc at lowest temperature) ............................ ....................... .. 48 60 ...................................................... 80 Vdc Aerating Range .......................................................................................lo...........................................ndc 8-48 8-60 8-80Vdc . Maximum Short Circuit Current Isc ......... ............. .... umurre.................................................................................................:........................................... Maximum D..Input Current 12.5 Adc Maximum Efficiency gg 5 Weighted ETf i ncy ................................................................................................8. gg g % Overvoltage Category .................................... II I ... ....... ...... OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) - Maximum Output Current ... ........ ......... ....... ......... ...... 15 Adc Maximum Output Voltage .... ....... 60 ......... .... ...... Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Vo@age per Power Optimizer 1 Vdc STANDARD COMPLIANCE _ EMC - .................................. ......... ........................ FCC Part15 Class B, IEC61000 6-2, IEC61000-6-3 ..................... ..................... .................................................IEC62109-1(class ..ROHS ..... ........................................................ II safety)_ UL1741 - .. .. .................... Yes ............. - INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage .............. ....... .................:................................................................................................................... 1000 Vdc Dimensions(WxLx H) ....................................... 141x 212 x 40.5/ 5,55 x 8.34 x 1.59 mm in �.. les) Weigh.t.(including cab ............... ..... ................................................ .................................... ........ 950 / 2 1 . In ut Connector P MC4 Am henol 7 co Output Wire Type / Connector ...................................... _ Double Insulated; Am henol ......................... ................. Output Wire length 1.2......................................... 0:95/3.0 /3.9 m/ft Operating Temperature Range .... .............................. -40 +85/-40-+185 ............ 'C-i Protection Ratin ........ .... g.....:.. ........................................... ........... ............................. . ...............................IP65/NEMA4 ..Relative Humidity..................... ....................—...........................................................................0 .............................................. 300 ..................................................... % �'�amasic ao�rmrne moawe.w+oeme oruo�o.sx ce.�r roier.mx.in.�a. 'PV SYSTEM DESIGN USING A SOLAREDGE -SINGLE PHASE - THREE PHASE THREE PHASE. INVERTER : ,... 208V ,;480V , MinimumString Length (Power Optimizers) ........................................................................................................................................................................... 8 10 18 MaximumString Length (Power Optimizers) ............................................................................................................................................................................ 25 25 50 Maximum Power per String ....................................................................................................................................................................... 5250 6000 12750 W Parallel Strings of Different Lengths or Orientations - Yes - Mono Multi Solutions 0 THE irfln�lv*nlount 60 CELL MULTICRYSTALLINE MODULE WITH TRINAMOUNT FRAME 245-260W POWER OUTPUT RANGE 15.9 MAXIMUM EFFICIENCY 0p--,3% POWER OUTPUT GUARANTEE As a leading global manufacturer of next generation photovoltaic products, we believe close cooperation with our partners is critical to success. With local presence around the globe, Trina is able to provide exceptional service to each customer in each market and supplement our innovative, reliable products with the backing of Trina as a strong, bankable partner. We are committed to building strategic, mutually beneficial collaboration with installers, developers, distributors and other partners as the backbone of our shared success in driving Smart Energy Together. Trina Solar Limited www.trinasolar.com Smart Energy Together MODULE PD05.18 d` L Fast and simple to install through drop in mounting solution Good aesthetics for residential applications Highly reliable due to stringent quality control • Over 30 in-house tests (UV, TC, HF, and many more) • In-house testing goes well beyond certification requirements Certified to withstand challenging environmental conditions • 2400 Pa wind load • 5400 Pa snow load LINEAR PERFORMANCE WARRANTY 10 Year Product Warranty • 25 Year Linear Power Warranty W00% d Addlt�onalV � alue fra m 90% M Tnna Solar's line W o ar or y Years 5 10 15 20 25 rlTrina standard .nru5try standard THE'il'1rTrimmount MODULE TSM-PD05.18 Q c U DIMENSIONS OF PV MODULE unit:mm 941 .N-N c Bm NAMEPUTE +99xi1 IHSTAWNG HOLE 6E I3 GN oWi 110.E 12-0BAIN HOLE A A Back View A -A I•V CURVES OF PV MODULE (245W) 10.m 9.m 8 0° 7m 80OW 6.m m s.m 4.m 3.m 2m 200W/m2 o.m m 0 O ELECTRICAL DATA @ SIC Peak Power Watts-PMAx (Wp) 245 250 255 260 Power Output Tolerance-PMAx(%) 0-+3 Maximum Power Voltage-VMP IV) 29.9 30.3 30.5 30.6 Maximum Power Current-IMPP (A) 8.20 8.27 8.37 8.50 Open Circuit Voltage-Voc (V) 37.8 38.0 38.1 '.. 38.2 Short Circuit Current-Isc (A) 8.75 8.79 8.88 9.00 Module Efficiency qm (%) :. 15.0 15.3 : 15.6 '.. 15.9 STC: Irradiance 1000 W/m2, Cell Temperature 25°C, Air Mass AM1.5 according to EN 60904-3. Typical efficiency reduction of 4.5% at 200 W/m2 according to EN 60904-1. ELECTRICAL DATA @ NOCT Maximum Power-PMAx (Wp) 182 186 190 193 Maximum Power Voltage-VMP(V) 27.6 28.0 28.1. 28.3 Maximum Power Current-IMPP (A) 6.59 6.65 6.74 6.84 Open Circuit Voltage (VI-Voc (V) 35.1 35.2 35.3 35.4 Short Circuit Current (A)-Isc (A) 7.07 7.10 7.17 7.27 NOCT: Irradiance at 800 W/m2, Ambient Temperature 20-C, Wind Speed 1 m/s. 0.00 to.- 20.°1 30.' Vouage(V) MECHANICAL DATA Solar cells Multicrystalline 156 x 156 mm (6 inches) `Cell orientation 60 cells (6 x 10) Module dimensions 1650 x 992 x 40 mm (64.95 x 39.05 x 1.57 inches) Weight 21.3 kg (47.0lbs) Glass 3.2 mm (0.13 inches),High Transmission, AR Coated Tempered Glass :Backsheet White Frame Black Anodized Aluminium Alloy with Trinamount Groove J-Box IP 65 or IF 67 rated :Cables :.. Photovoltaic Technology cable 4.0 MM2 (0.006 inches'), . 1200 mm (47.2 inches) Fire Rating Type 2 - - TEMPERATURE RATINGS Nominal Operating Cell q4°C (±2°C) Temperature (NOCT) -: Temperature Coefficient of PMAx -0.41%/°C Temperature Coefficient of Voc -0.32%/°C Temperature Coefficient of Isc 0.05%/°C WARRANTY 10 year Product Workmanship Warranty 25 year Linear Power Warranty (Please refer to product warranty for details) CERTIFICATION C S PACKAGING CONFIGURATION RB a us Modules per box: 26 pieces -C1 I RI Modules per 40' container: 728 pieces MAXIMUM RATINGS - Operational Temperature -i-40-+85°C Maximum System t000V DC(IEC) Voltage 1000V DC(UL) Max Series Fuse Rating 15A a rn al Z EU COMPLIANT • CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. QpoMPATjB !� '"� (� © 2014 Trina Solar Limited. All rights reserved. Specifications included in this datosheet are subject to runm solar change without notice. Smart Energy Together, CaMPpS�O 0 ['"TRF mount 60 CELL MULTICRYSTALLINE MODULE WITH TRINAMOUNT FRAME 250 -265W POWER OUTPUT RANGE 16.2% MAXIMUM EFFICIENCY 0m+3/o POSITIVE POWER TOLERANCE As a leading global manufacturer of next generation photovoltaic products, we believe close cooperation with our partners is critical to success. With local presence around the globe, Trina is able to provide exceptional service to each customer in each market and supplement our innovative, reliable products with the backing of Trina as a strong, bankable` partner. We are committed to building strategic, mutually beneficial collaboration with installers, developers, distributors and other partners as the backbone of our shared success in driving Smart Energy Together. Trina Solar Limited www.trinasolar.com ' ermsolar Smart Energy Together PD05.18 Fast and simple to install through drop in mounting solution Good aesthetics for residential applications Highly reliable due to stringent quality control O • Over 30 in-house tests (UV, TC, HF, and many more) • In-house testing goes well beyond certification requirements • PID resistant Certified to withstand challenging environmental conditions • 2400 Pa wind load • 5400 Pa snow load LINEAR PERFORMANCE WARRANTY 10 Year Product Warranty • 25 Year Linear Power Warranty 1100% 3 Additional nol Value tro I m Trina S „ 90� **" olarsline ar N'arronty l2 80% Years 5 10 15 20 25 [I Trina standard I rd;ls;ry standard THE Tr*lnmmount MODULE TSM-PD05.18 . DIMENSIONS OF PV MODULE ELECTRICAL DATA @ STC unit:mm Peak Power Watts-PMnx (Wp) 250 255 260 265 o UNCMN BOX NRMEP - 1-09x12 INSfRILiNG HOLE i3 be i.3 GROUNDINGi- A A r3-DRNHIxILE R72 1R0 Power Output Tolerance -PM. (%) j - 0-+3 Maximum Power Voltage-VMP (V) 30.3 30.5 30.6 30.8 o Maximum Power Current-IMPP (AJ 8.27 8.37 8.50 8.61 m Open Circuit Voltage-Voc (V) O 38.0 38.1 38.2 38.3 Short Circuit Current-Isc (A) -. 8.79 8.88 9.00 9.10 Module Efficiency rl , (%). 15.3 15.6 15.9 16.2 STQ Ivadiance 1000 w/m-, Cell Temperature 25°C, Air Mass AM1.5 according to EN 60904-3. Typical efficiency reduction of 4.5%at 200 W/m2 according to EN 60904-1. _ 0 ELECTRICAL DATA @ NOCT MaximumPower-PMAx (Wp) - 186 190 193 197 Maximum Power Voltage-VMP (V) 28.0 28.1 28.3 28.4 Maximum Power Current-iMPP(A) 6.65 6.74 6.84 6.93 Open Circuit Voltage (V) Voc (V) 35.2 35.3 35.4 35.5 Short Circuit Current (A)-Isc (A) - 7.10 7.17 7.27 7.35 NOCT: Irradiance at 800 W/m', Ambient Temperature 20-C, Wind Speed l m/s. Back View - W a qq I-V CURVES OF PV MODULE (260W) 10.00 9.W 8.00 T.W u 5.99 9.M &W 2.00 1.00 MECHANICAL DATA Solar cells Multicrystalline 156 x 156 mm (6 inches) ..Cell orientation 60 cells (6 x 10) Module dimensions 1650 x 992 x40 mm (64.95 x 39.05 x 1.57 inches) Weight 19.6 kg (43.12lbs) Glass 3.2 mm (0.13 inches),High Transmission, AR Coated Tempered Glass 'Backsheet White Frame Black Anodized Aluminium Alloy J-Box t IP 65 or IP 67 rated Cables 7 Photovoltaic Technology cable 4.0 mm' (0.006 inches'), 1200 mm (47.2 inches) Connector H4 Amphenol Fire Type UL 1703 Type 2 for Solar City TEMPERATURE RATINGS MAXIMUM RATINGS NominalOperatingCell 44°C (±2°C) Operational Temperature-40-+85°C Temperature (NOCT) `Maximum System 1000V DC(IEC) ' Temperature Coefficient of PMnx - 0.41%/°C . Voltage 1000V DC(UW Temperature Coefficient of Voc - 0.32%/°C Max Series Fuse Rating 15A 0 10 20 30 40 60 lemperarure l OerrlClenl al Isc _. u.w]oC 1. vNxvm WARRANTY CERTIFICATION 10year Product Workmanship Warranty `25 year Linear Power Warranty A L D UL G. (Please refer to product warranty for details) LISTED a us 1 E(IiI wEEE PACKAGING CONFIGURATION COMPLIANT - Modules per box: 26 pieces Modules per 40' container: 728 pieces al ni WI CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. G0100,B ��11I� ®! c ® 2015 Trina Solar Limited. All rights reserved. Specifications included in this datasheet are subject to !� ■ ran-aSolar change without notice. Smart Energy Together caMPp<0 soar-®:� a SolarEd� ge Single Phase Inverters f For North America IL SE3000A / -US / SE380OA-US / SE5000A-US / SE6000A-US SE7600A-US / SE10000A-US / SE11400A-US s t' m - overte - 6 " - > Warta , 5 ry 3 F e 4 r a �f w i J VN The best choice for SolarEdge enabled systems ;• Integrated arc fault protection (Type `i)'for NEC 2011690:11 compliance ' Superior efficiency (98%) Small _ lightweight and easy to Install on provided bracket Built-in module -level monitoring Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter, DC/AC conversion only Pre -assembled Safety Switch for faster installation Optional — revenue grade data, ANSI C12.1 USA - GERMANY - ITALY - FRANCE -JAPAN - CHINA - AUSTRALIA - THE NETHERLANDS - ISRAEL www.solaredge.us -,.._ Single Phase Inverters for North Americaso Solar r SE3000A US /SE380OA US/ SE5000A US/ SE6000A US/ SE7600A-US / SE10000A-US / SE11400A-US SE3000A-US I SE380OA-US I SE5000A-US F SE6000A-US I SE760OA-US I SE10000A-LI5 SE 140OA-US ntlTpuT _.. ... ... Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V 11400 VA ..................... .................. .. ......... ......... ......83 10000.@240V_ .................. Max. AC Power Output p 3300 4150 5400 @ 208V 6000 6000 8350 10800 @ 208V ............ 12000 .... VA ........................................ ................ ................ 5450 240V, ....... 10950 240V AC Output Voltage Min: Nom: Max.(') 183 - 208 - 229 Vac ........................................... � ✓ AC Output Voltage Min: Nom: Max.PI ................ ............... ................. ✓ ................................ ✓ ✓ ..:..........:.... .................. ✓ ..........: 211- 240 - 264 Vac .......................................... ✓ AC Frequency Min. Nom.:Max.(')...... ......... ................ . ............... ............ ............... I.. ................. ............. ..tting ..... 0-6 ................ .................. 593-60-605 .•...........:. (with HI country setting 57 :60 ; 60:r'!............. . _ ��••••••� HZ..... Max. Continuous Output Current 12.5 16 ( 25 ( 32 .................. @ 47.5 ... A .......................................... .......... 21_@.240y •• q2 240V GFDI Threshold ...... ........ .... ........................... ........ ......... 1.......@.........�.................. ......... ........... Utility Monitoring, Islanding Protection, Country Configurable Thresholds ..................................................... Yes ....A ..... Yes INPUT Maximum DC Power(STC) ............. ....... .. 4050 5100 6750 8100 10250 13500 15350 W Transformer -less,. Ungrounded. Yes MaxIn ut Volta a .. ..... P .......g. ................. .................................... ......... .................................................. 500 ........ vd�.... Nom. DC Input Voltage ................ ................ ............... ............325 @ 208V/ .350 @ 240V......... Vdc Max Input Current(2)........................ 9.5 �............... 13 16.5@208V �..iss. 18 23 .................. .................. 33@208V 34.5 ••Adc• ................ (a 240V. ..................................30;S,Ga1240y..�.................. Max Input ShortCircuit Current ....... .............................. .......................................................................................... 45 ........... Adc.... Reverse -Polarity Protection .. ................... .......................................................................................................................... Yes Ground -Fault Isolation Detection 600kn Sensitivity ........... Maximum Invert er Efficienc .............................. Y.......... 97.7 ................ .....98:?..... ......98:3...... ..... 98:3............ 98....... 98 98........ CEC Weighted Efficiency 97.5.....1......98......1. 998 I..... 975.....I..... 97.5...... ....... .......�....... 97 @ 208V 97.5 ....3°..... % ....... ......... ................ • .... @.240V , ,.97S,�a, 240V ... ................. Nighttime Power Consumption <2.5 <4 ........... W ADDITIONAL FEATURES Supported Communication Interfaces .......................................... ........................................... RS485, RS232, Ethernet, ZigBee (optional) ...tiona.......................................................... Revenue Grade Data, ANSI C12.1 OptionaP' ........... Rapid Shutdown —NEC 2014 690.12 Functionality enabled when SolarEdge rapid shutdown kit is installed(4) Safety UL3741, 1.11-16996, UL3998, CSA 22.2 ................................................................................................................................................. ........... Grid Connection . .. Standards IEEE1547 ...........................................:...................:..:.. """"' Emissions FCC part15 class B AC output conduit size / AWG range DC input conduit size / # of strings / AWG range ............................ Dimensions with Safety Switch ,.(Hxwxp), ,.. . 3/4" minimum / 16:6 AWG minimum 3/4" minimum / 1-2 strings / 3/4. minimum / 1-2 strings / 16-6 AWG 14.6 AWG ................. 30.5 x 12.5 x 7.2 / 775 x 315 x 184 30.5x12.5x10.5/ .................................... .. 775 x 315 x 260 ............................... ...............x 315................ Weight with Safety Switch .. . ........ ......... 51.2 / 23.2 54.7 / 24 7 88 .4 / 40.1 .. Natural convection Cooling Natural Convection and internal Fans (user replaceable) fan (user ............................................................................................................. .replaceable)........... ........................... Noise < 25 < 50 ..................................... ............. ........................................................................ Min. -Max. Operating Temperature -13 to+140 / 25 to+60 (-40 to +60 version available(')) Range. .......................................................................................................................................................... Protection Rating NEMA 3R