Loading...
Zoning ReviewL 178.75' 182.49' S34.29'50"W S34'29'50"W / SETBACK LINE P. (0 PUMP CHAMBER 100"o o ` - i 9° t0 a _ p \ I 11 ^ X 01. � 0 00 \ \ �ovPROP. 5 BDRM. HOME EER_103.0BASMNT 1 FI_R=95.0� C° o \N SEPTIC TANK ot• °,4' �-BOX ��P X t X �AXPRNXIMATE LOCATION O \ E ISTI G 6 DI WATER M I FROM ROCK O'DUNDEE ROAD 0o as o aaooaoaooc s 20, BENCHMARK: 0 p f SPIKE IN TREE w i ! ELEV. 100.00 / I DATUM: ASSUMED Vol EXISTING 40' WIDE ACCESS AND o / / UTILITY EASEMENT LEGEND -___ PROPER IY LINE 00000o STONE WALL EDGE OF VEGETATION ----100-_-- EXISTING CONTOUR X i 00.50 EXISTING SPOT GRADE PROPOSED CONTOUR X 101.50 PROPOSED SPOT GRADE W EXISTING WATER LINE ® CURB STOP (g) ELECTRICAL MANHOLE X 40 20 0 40 80 120 GRAPHIC SCALE / 1 "=40' PUMP CHAMBER DOSING CALCULATIONS STATIC HEAD DYNAMIC HEAD D-BOX INVERT: ELEV.=105.42 EQUIVALENT PIPE LENGTH: FLOOR OF PUMP CHAMBER ASSUME THREE (3) 90° ELBOWS: 5'PER ELBOW 15' MIN. EFFLUENT LEVEL ELEV.= 91.70 ASSUME ONE (1) CHECK VALVE: 15' STATIC HEAD: 13.72 FT. ASSUME ONE (1) GATE VALVE: 1.5' ASSUME THREE (3) 45° BENDS: 2.5' PER BEND = 7.5' PIPE LENGTH = 208' TOTAL EQUIVALENT PIPE LENGTH = 15'+15'+1.5'+7.5'+208' = 247' EFFLUENT DOSE VOLUME DRAWDOWN OF DOSING TANK PIPE LENGTH IN DISPOSAL FIELD = 150 LF OF 4" DIAMETER PIPE PUMP CHAMBER: 4'X4' PRECAST BASIN ORCEAMLIN VIrOLDUX L= 4 OX L = 4 (2/12)2 X 208' X (7.481 GAL./FT') = 34 GALS. CALCULATE VOLUME OF DOSE TANK PER LINEAR FOOT HEIGHT 4 V = AXL = (4'X4') X 1.0' X (7.481 GAL./FT) = 119.69 GALS./FT. OF CHAMBER V=�(4/12)2 X 150' X (7.481 GAL./FT') = 97.9 GALS. AT 100% DOSE VOLUME EFFLUENT DEPTH = 132 GALS./119.69 GALS. PER FT. OF CHAMBER = 1.1' TOTAL DOSE VOLUME = 34 GALS. + 97.9 GALS. = 131.9 GALS. (SAY 132 GALS.) EMERGENCY STORAGE CAPACITY: 550 GALS./119.69 GALS. PER FT. OF CHAMBER = 4.6' ELEV.=103.0t 'a ELEV.=98.45 WATERPROOFING ° MEMBRANE OR : COATING ELEV.=95.0f �•�4 CRUSHED STONE ELEV.=98.25 1,500 GALLON SEPTIC TANK (TO BE CONSTRUCTED ACCORING TO SECTION 15.226 OF THE AIADEP REGULATIONS) DRAINAGE MATERIAL RAVEL FILL 4" FOOTING DRAIN WITH FILTER FABRIC OVER DRAIN BURIED ELECTRICAL SUPPLY LINE AND ALARM WIRES FROM/TO PROPOSED DWELLING D-BOX HEAVY DUTY MANHOLE FRAME & COVER w O OO 'GATE VALVE R ELEV.=98.00 HIGH LEVEL ALAPM EL V.=s .0 ELEV.=97.50 CHECK VALVE W/ BLEEDER OFF LEVEL fLEV=93.3 OFF LEVEL ELEV =92.2 6• CHAMBER FLR. .6 .... 7...... .... ... ._.._.. ELEV=91.70 4'X4' PUMP CHAMBER NOTE: THE PUMP CONTROLS SHALL BE INSTALLED BY A LICENCED ELECTRICIAN. 2" FORCE MAIN TYPICAL DISPOSAL SYSTEM PROFILE (NOT TO SCALE) 4" PVC PIPE SHALL MEET THE MATERIAL SPECS. IN SECITON 15.251(5) OF THE MADEP REGULATIONS DISPOSAL BED -���A TEST HOLE LOGS LOT 4 ESTATE LOT 11 LOT 7 LOT 6 LOT 8 N/F HERVEY R. & LENA CHARPDMER / / LOT 15 LOT 16 LOT 14 LOT 4 LOT 3 LOT 2 AREA MAP OF PARDON HILL SUBDIVISION SCALE: 1" = 300' TEST HOLES WERE PERFORMED ON APRIL 17, 2003 BY TIBBETTS ENGINEERING CORP. AND WITNESSED BY CHRIS MICHAUD WITH THE DARTMOUTH BOARD OF HEALTH. TEST HOLE 1A TEST HOLE 2A 0-8" SANDY LOAM 0-7" SANDY LOAM 8-27" SANDY LOAM 7-27" SANDY LOAM 27-53" LOAMY SAND 27-50" VERY FINE SANDY LOAM 53-115" SANDY LOAM 50-119" LOAMY SAND ESTIMATED HIGH GROUNDWATER: 85" ESTIMATED HIGH GROUNDWATER: 45" PERCOLATION RATE: 6 MIN./INCH PERCOLATION RATE: 13 MIN./INCH tLtV. = I V 4. / 0 V ELEV.=100.25 4" OF DOUBLE WASHED STONE (MATERIAL SPEC. TO MEET THE REQUIREMENTS OF SECTION 15.247(2) OF THE MADEP REGULATIONS) 6" OF CRUSHED STONE (MATERIAL SPEC. TO MEET THE REQUIREMENTS OF SECTION 15.247(1), BASE AGGREGATE OF THE MADEP REGULATIONS) NOTE: THE DISPOSAL BED SHALL BE VENTED PER THE REQUIREMENTS OF THE DARTMOUTH BOARD OF HEALTH SUPPLEMENTAL REGULATIONS TO TITLE 5: 310 CMR 15.000 AND SHALL CONFORM TO THE REQUIREMENTS OF SECTION 15.241 OF THE MADEP TITLE 5 REGULATIONS. GENERAL NOTES DESIGN DATA DESIGN PERC: 15 MIN./INCH DESIGN FLOW: 5 BEDROOMS X 110 GPD/BEDROOM = 550 GPD LEACHING AREA REQUIRED: 550 GPD/0.56 GPD/SQ.FT. = 982 SQ. FT. LEACHING AREA PROVIDED: 50 FT. X 20 FT. X 0.56 GPD/SO.FT. = 1,000 SQ. FT. NOTE: PROVISIONS FOR A GARBAGE GRINDER HAVE NOT BEEN INCLUDED IN THIS DESIGN. 1 • THE PROPERTY LINES PRESENTED HEREIN WERE TAKEN FROM THE PARDON HILL SUBDIVISION PLANS PREPARED BY TIBBETTS ENGINEERING CORP. DATED MARCH 3, 1999. 2. THERE ARE NO EXISTING PRIVATE WELLS OR PRIVATE WELLS KNOWN TO BE PROPOSED WITHIN 200 FEET OF THE PROPOSED SYSTEM. 3. THERE ARE NO EXISTING PUBLIC DRINKING WATER SUPPLY WELLS OR PUBLIC DRINKING WATER SUPPLY WELLS KNOWN TO BE PROPOSED WITHIN 500 FEET OF THE PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM. THE WATER SUPPLY FOR THIS LOT IS MUNICIPAL PUBLIC SYSTEM. 4. NO TIDEWATER OR WATERCOURSE LIES WITHIN 200 FEET OF THE PROPOSED SYSTEM. 5. THERE ARE NO PRESSURE WATER SUPPLY LINES EXISTING OR PROPOSED WITHIN 25 FEET THE PROPOSED SEWAGE DISPOSAL SYSTEM. 6. THE CURRENT "TITLE V (310 CMR)" REGULATIONS ENFORCED BY THE STATE OF MASSACHUSETTS DEPARTMENT OF ENVIRONMENTAL PROTECTION ARE TO BE CONSIDERED A PART OF THIS PROPOSED SEWAGE SYSTEM DESIGN. SEWAGE DISPOSAL NOTES 1. THE PROPOSED SEPTIC TANK SHALL HAVE A 1,500 GALLON LIQUID CAPACITY AND SHALL MEET THE REQUIREMENTS OF SECTIONS 15.223: SEPTIC TANKS, 15.226: CONSTRUCTION OF SEPTIC TANKS, 15.227: PLACEMENT AND CONSTRUCTION OF TEES, AND 15.228: PLACEMENT AND ACCESSIBILITY OF SEPTIC TANK OF THE CURRENT TITLE V REGULATIONS. 2. ALL PVC PIPE USED FOR THE SEWAGE DISPOSAL SYSTEM, INCLUDING THE BUILDING SEWER SHALL BE SPECIFIED SCHEDULE 40 PVC OR APPROVED EQUAL. 3. FINISH GRADE IN THE SYSTEM AREA SHALL ENSURE POSITIVE SURFACE WATER RUN-OFF ABOVE THE SYSTEM. THE SEPTIC TANK, PUMP CHAMBER, AND DISTRIBUTION BOX SHALL BE PROVIDED WITH A COVERED ACCESS MANHOLE AT GRADE THE DISTRIBUTION BOX SHALL BE PROVIDED WITH A MARKER SET TO LOCATE THE COVER. 4. HEAVY MACHINERY SHALL NOT PASS OVER THE LEACHING AREA. 5. THE SURFACE AREA OVER THE SUBSURFACE DISPOSAL SYSTEM SHALL BE SEEDED. 6. THERE SHALL BE NO PARKING IN THE AREA OF THE LEACHING SYSTEM. 7. ALL BUILDING SEWERS AND INDIVIDUAL SEWAGE DISPOSAL SYSTEMS SHALL BE MAINTAINED IN GOOD REPAIR BY THE OWNER. THE USE OF ACID AND ORGANIC CHEMICAL SOLVENTS IN THE SYSTEM IS PROHIBITED. IT IS RECOMMENDED THAT THE SEPTIC TANK BE PUMPED EVERY TWO YEARS OR MORE FREQUENTLY IF THE SYSTEM IS USED CONTINUOUSLY AT MAXIMUM DAILY ESTIMATED SEWAGE FLOW. 8. MATERIALS AND CONSTRUCTION SHALL CONFORM TO THE THE CURRENT "TITLE V (310 CMR)" REGULATIONS ENFORCED BY THE STATE OF MASSACHUSETTS DEPARTMENT OF ENVIRONMENTAL PROTECTION. LOCATION MAP SCALE: 1 "=2000' ZONING REQUIREMENTS ZONE: SINGLE RESIDENCE B (SRB) REQUIRED PROVIDED LOT FRONTAGE 200 FT. 200 FT. TOTAL AREA 80,000 SF 206,387 SF COVERAGE 50% (MAX.) 2.5% SETBACKS FRONT YARD 60 FT. 60 FT. SIDE YARD 20 FT. 20 FT. REAR YARD 20 FT. 20 FT. Dartmouth Building Department 400 Slocum Road P.O. Box 79399 v Dartmouth, MA 02747 508-910-1820 4- FAX 508-910-1838 ,ZONINGREVIFW �r Plat: Lot;;''Yr °Street: Subdivision Namd: oil . Owner's Name i gz` Designer: Contact Person: � Designer's Specialty Professional Erigi Sanitarian ❑ Other ❑ m - c: I wpdocslformslzonerev.lab 0 Surveyor ❑ July 27, 2000 SUBSURFACE SEWAGE DISPOSAL SYSTEM OWNER: DOUG LE DO ASSESSORS MAP: 24, LOT 59 STREET LOCATION:' PREPARED BY: ANTHONY A. NENNA, P.E. DATE: MAY 2003 a5o�� CONTACT PERSON: DOUG LE DO, ADDRESS: 679 ELM STREET, SOUTH DARTMOUTH, MA TEL: 508-994-3771 J