Loading...
Zoning ReviewI SOIL DATA ESTATE LOT 2B ESTATE LOT 2C DESIGN DATA PERFORMED BY: RICHARD ALVES DATE: 10/01/97 WITNESSED BY: CHRIS MICHAUD o„ TP 120 75 5 n" TP 121 75_8 75.3 2" 75.1 5" 72.5 30" 69.2 76" TOP VIEW 3, 5 DIA. INLETS 5"dia. outlet 2" 5" 36" 76" "0" LAYER "0' LAYER "A" LAYER "A" LAYER SANDY LOAM SANDY LOAM 10YR 3 2 10YR 3/2 B LAYER -8- LAYER SANDY LOAM SANDY LOAM 10YR58 10YR58 "Cl* LAYER *Cl* LAYER U. SANDY LOAM V.F. SANDY LOAM 2.5Y 6/3 10YR 7/1 "C2" LAYER "C2" LAYER LOAMY SAND LOAMY SAND 1OYR 5/4 10YR 5/4 108" I 66.5 96" 67.8 PERC AT 64" PERC AT 50" RATE: 1" in 7 min. RATE: 1" in 7 min. MOTTLES AT 26" (73.3) MOTTLES AT 30" (73.3) LEGEND 75.6 75.4 73.3 69.5 EARTH BACKFILL \ 0° e p 06 0 4 a 0 e 0 00 e 0 e 0 0 ° ° 04 0 o e 4 o e 4 op o o O p 0 0 4 o a 0 4 0 4 0 0 04 o a 0 0 4 o a 4 0 0 av o °d a d vv v v a v °d a d v v vd vd ad v v v vvssv v�av vvd ad dvd vv vv v v vd v d dvd vvv d v d v v v v v ve vvd v v v v d vvd v v v v v v v vv v vv a v vv v _ v v v v v v 12' MIN, EARTH 12" BACKFILL - 2" DEPTH OF 1 /8" - 2" 1/2" WASHED PEASTONE 10" DEPTH OF 3/4" TO 10" 1-1 /2" WASHED CRUSHED STONE 0 O 6 TYPICAL LEACHING FIELD CROSS SECTION "NOT TO SCALE 100 EXISTING CONTOUR PROPOSED CONTOUR PIPE INVERT ELEVATION ® TEST PIT 0 SEPTIC TANK DISTRIBUTION BOX v PROPOSED WATER SERVICE LINE OBSERVED GROUNDWATER TABLE ELEVATION RESERVE AREA N 742. 90 792.05' 780' ESTATE LOT 2D ,902 D E p\ S FV E N _T °t N DR�VEWAY ESTATE LOT 50 WID E DE COMMO2C ........................ ACE r I r I �/ r i o�� Gj\,P �V i 30.5" / \ r 1 / / 18.5" / ti, /c 1 !: r 1 Q j ? / 7.5' J / w i � t o } # O .... END VIEW p GPD i I Gj� o° Z. 5, 5" DIA. OUTLETS I' PROPOSED U . WELL CROSS SECTION VIEW DISTRIBUTION BOX NOT TO SCALE \ , r 10'-6" I \ i 1" taper 5'- 4" PLAN VIEW r4" T CROSS SECTION VIEW SEPTIC TANK NOT TO SCALE i �0) 3.5"dia. knockouts - ! inlet DWELLING t / FINISW/GRADE TOP OF ELEVx = 91.0 FOUNDATION ELEV.= 94.50 ; �� li ;' II ;t '1 \\ BENGHMA( K: NAIL IN 14",, rR i J i r # ► t , ELE I 79. 8,," rCD CS7 ! t f rL I 1 1 00 n f: CC 1 IF \ TP120 63' t 1 � -P121------- � -------- 9 1 r l I I - - - - - - - - ` U ` 21j 35' \ t \ \ I LIMIT OF �� EXCAVATION CO co .� C -1, w ru Y' O \ 9\ �'� 5' TYPICAL -� ESTATE LOT 20� >� AREA=2'4.0,040-,-F (5.51-1 ACRES) c40 f o \\ \\ 00 ' t \ P1 N0TF�: 1. THIS` LOT IS PART OF AN APPROVAL NOT REQUIRED SUBDIVISION PREPARED FOR ALLAN SCHELL et al LOCATED ON DIVISION ROAD. 2. THE LOT IS LOCATED IN A SINGLE RESIDENCE PLOT PLAN B (SR-B) ZONING DISTRICT. -__--- -- 3 THIS LOT IS LOCATED IN A FIRM ZONE ,ideys Corner LOCUS SLADES FARM LANE Slades Corner Ne. Bedford Clty RM, ABNER ` POTTERS WAY SCALE: 1 = 30' 4. PER CENT LOT COVERAGE: 2% VICINITY MAP 5. REQUIRED PARKING SPACES PROVIDED IN GARAGE 6. AQUIFER ZONE "Y ,- FINISH GRADE EL.=79.5 SLAB ELEV.= 5' f f ( 5' 87.0 --Er I L 1500 GALLON REINFORCED CONCRETE 8 ,0 =7810- v4'-6" 87,SEPTIC TANK 78,00 v v v v v 77,80 5DISTRIBUTION \�4.83 v 3/4"-1 1/2" DOUBLE WASHED v86,77SIBUTION v STONEBOX 7 BOX v v v v 77.30 1 SEASONAL HIGH GROUNDWATER ELEV.= 73.3 3 LEVEL STABLE BASE LIMIT OF EXCAVATION 69.2 NOTE: THERE ARE NO WELLS WITHIN 200 FEET SYSTEM PREIFILE OF THE PROPOSED SEPTIC SYSTEM. DESIGN PERC RATE: 1" IN 10 min. DESIGN FLOW: 3 BEDROOMS X 110 GPD/BDM = 330 GPD REQUIRED SYSTEM DESIGN: USE 35' LONG X 20' LEACHING BED BOTTOM: 35' LONG X 20' WIDE X 0.60 G/SF = 420 GPD PROVIDED WHIRLPOOL CAPACITY: (420 GPD-330 GPD)/2 + 45 GALLONS= 90 GALLONS MAXIMUM ZONING REQUIREMENTS (MINIMUM) AREA 240,000 SF (160,000 CONTIGUOUS UPLAND) FRONT YARD SETBACK 60 FT SIDE YARD SETBACK 20 FT REAR YARD SETBACK 20 FT GENERAL NOTES 1) THIS SYSTEM SHALL BE INSPECTED WHEN LEACHING AREA IS FULLY EXCAVATED AND WHEN ALL COMPONENTS ARE IN PLACE. WHEN THE SYSTEM IS READY FOR INSPECTION, THE CONTRACTOR SHALL NOTIFY THE LOCAL BOARD OF HEALTH. 2) WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND FINES. 3) ALL ELEVATIONS ARE BASED ON ASSUMED ELEVATION DATUM. 4) HEAVY EQUIPMENT SHALL NOT BE ALLOWED TO OPERATE OVER THE LIMITS OF THE SEWAGE DISPOSAL SYSTEM DURING THE COURSE OF CONSTRUCTION. 5) NO FIELD MODIFICATIONSE TO THE SEWAGE DISPOSAL SYSTEM SHALL BE MADE WITHOUT PRIOR WRITTEN APPROVAL OF THE ENGINEER AND THE LOCAL BOARD OF HEALTH. 6) UNLESS OTHERWISE NOTED ALL SYSTEM COMPONENTS SHALL BE INSTALLED IN ACCORDANCE WITH TITLE V OF THE STATE ENVIRONMENTAL CODE AND ANY APPLICABLE LOCAL REGULATIONS. 7) SEPTIC TANK, DISTRIBUTION BOX, ETC. SHALL BE MANUFACTURED BY A. ROTONDO & SONS OR APPROVED EQUAL. 8) GROUT TO BE USED AT ALL POINTS WHERE PIPES ENTER OR LEAVE ALL CONCRETE STRUCTURES IN ORDER TO PROVIDE A WATERTIGHT SEAL. 9) ALL SHIPLAP JOINTS IN THE SEPTIC TANK SHALL BE SEALED WITH NEOPRENE GASKETS OR ASPHALT CEMENT. 10) EXCAVATE ALL UNSUITABLE MATERIAL IN LEACHING AREA AND BACKFILL WITH CLEAN GRAVEL AND COARSE SAND. 11) THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL UNIT. BOARD OF HEALTH STAMPS BOARD OF HEALTH STAMPS 71011i N, Or. DA RTr�ol TH ZoNwo n vii,: v Ii tc. IREF0,11 r-tt JUL 06 1999 P,E, ST M � ,0 OF MASS4, -StwF-"°. OWNER: M I CH AEL CAM AR A 0 G1p1OSA rtiV1L v> S tJn 32j650 g ASSESSORS MAP & LOT: ESTATE LOT 2D A9 9FGIS1EP ssroNi�STREET LOCATION: OFF SLADES FARM LANE ENGINEERING FIRM: P,L.S, STAMP SITEC, Inc. 13 Weiby Road New Bedford, MA 02745 (508) 998-2125 Civil and Environmental, Engineering FAX (508) 998-7554 Land Use Planning DATE: MARCH 6, 1999 CONTACT PERSON: BRIAN LEVESQUE ACAD NO, FILE NO, y D JUN 2 3 Ir