Loading...
Zoning ReviewFILL "A" LAYER SANDY LOAM 10YR 3/2 FRIABLE "Cl" LAYER V.F. SANDY LOAM 10YR 6/2 V.F.SILTY SAND "C2" LAYER COARSE SAND 1OY 5/4 20-30% SAND& rC� STONE " LAYER DY LOAM • --- v 69.2 68.7 20' 64.4 90 [.Tom 60 0 148' SOIL DATA PERFORMED BY. RICHARD ALVES PERFORMED BY: R❑BERT PICKERING WITNESSED BY: CHRIS MICHAUD WITNESSED BY: CHRIS MICHAUD DATE: 10/01/97 DATE: 8/20/97 TP 117 ONLY „ TP 122 rl TP 123 ,n r _„ TP 117 695 V 10' 16 12C CA 120' "A" LAYER SANDY LOAM 10YR 3/1 FRIABLE GRAVELLY "B" LAYER SANDY LOAM 10YR 5/6 FRIABLE GRAVELLY "Cl" LAYER V.F. SANDY LOAM 2.5YR 6/3 FIRM "C2" LAYER MEDIUM TO COARSE SAND 7.5YR 5/6 LOOSE, VERY GRAVELLY 58.2 1 '.)Alll 59.0 PERC AT 94" MOTTLES AT 15" (69.3) PERC AT 76" RATE: 1" in < 2 min. RATE: 1" in < 2 min. MOTTLES AT 22" (68.2) �� MOTTLES AT 20" (67.8) "A" LAYER SANDY LOAM 10YR 3/2 FRIABLE "Cl" LAYER V.F. SANDY LOAM 1OYR 6/2 V.F.SILTY SAND "C2" LAYER COARSE SAND 1OYR 5/4 20-30% SAND& STONE -- u 12' 68.8 20' 63.0 60 18.5" 7.5" 3, 5" DIA. INLETS TOP VIEW 5, 5" DIA. OUTLETS CROSS SECTION VIEW END VIEW DISTRIBUTION BOX 68.5 EARTH BAC K FI LL \\ 0 0 0 0° 0 p a<D D v a 0 O 0 0 0 ° 0 p v° 0 O p° 0 p v p v v° ° 0 D DOp o D 0 0 p v ° p o p°v 0 o O p O vv v° v o v v v vd v v 4° v° p e ° v v v v° d v dv ° ° ° ° ° v v v vd ° v v v v v v ° v v v v v 9-9 ttPICAL OF ALL 3 6JB TYPICAL LEACHING FIELD CROSS SECTION_ 64.5 1 NOT TO SCALE 93' PLOT PLp N _ SCALE: 1 =150' SITE SUMMARY J a 12" MIN. EARTH 121, BACKFILL — 2" DEPTH OF 1 /8" — 2" 1 /2" WASHED PEASTONE 10" DEPTH OF 3/4" TO 10" 1-1/2" WASHED CRUSHED STONE CONTRACTOR SHALL MATCH DRIVEWAY EXTENSION WITH EXISTING DRIVEWAY i 11 LEGEND -- - 100--- - -- EXISTING CONTOUR PROPOSED CONTOUR � 75.00 PIPE INVERT ELEVATION ® TEST PIT ® SEPTIC TANK DISTRIBUTION BOX w PROPOSED WATER SERVICE LINE v OBSERVED GROUNDWATER TABLE ELEVATION RESERVE AREA New Bedford C'ily Rifle Range ® � G y'Gidlevs Comer LOCUS ABNERX POTTERS WAY SIADES FARM LANE S�pES CORNER Slades Comer MAP 27 LOT 8 -' r, = SUBDIVISION LOT — AREA. 240061 SQ.z�T. 5.51 ACRtS t Ii River DESIGN DATA DESIGN PERC RATE: 1 " IN 5 min. DESIGN FLOW: 4 BEDROOMS X 110 GPD/BDM = 440 GPD REQUIRED SYSTEM DESIGN: USE 35' LONG X 20' LEACHING BED BOTTOM: 35' LONG X 20' WIDE X 0.74 G/SF = 518 GIRD PROVIDED MAXIMUM ALLOWABLE WHIRLPOOL CAPACITY: (518 GPD-440 GPD)/2 + 45 GALLONS = 84 GALLONS ZONING REQUIREMENTS (MINIMUM) AREA 240,000 SF (160,000 CONTIGUOUS UPLAND) FRONT YARD SETBACK 60 FT SIDE YARD SETBACK 20 FT REAR YARD SETBACK 20 FT GENERAL NOTES 1) THIS SYSTEM SHALL BE INSPECTED WHEN LEACHING AREA IS FULLY EXCAVATED AND WHEN ALL COMPONENTS ARE IN PLACE. WHEN THE SYSTEM IS READY FOR INSPECTION, THE CONTRACTOR SHALL NOTIFY THE LOCAL BOARD OF HEALTH. 2) WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND FINES. 3) ALL ELEVATIONS ARE BASED ON ASSUMED ELEVATION DATUM. 4) HEAVY EQUIPMENT SHALL NOT BE ALLOWED TO OPERATE OVER THE LIMITS OF THE SEWAGE DISPOSAL SYSTEM DURING THE COURSE OF CONSTRUCTION. 5) NO FIELD MODIFICATIONS TO THE SEWAGE DISPOSAL SYSTEM SHALL BE MADE WITHOUT 6) UNLESS OTHERWISE NOTED ALL SYSTEM COMPONENTS SHALL BE INSTALLED IN ACCORDANCE WITH TITLE V OF THE STATE ENVIRONMENTAL CODE AND ANY APPLICABLE LOCAL REGULATIONS. 7) SEPTIC TANK, DISTRIBUTION BOX, ETC. SHALL BE MANUFACTURED BY A. ROTONDO & SONS OR APPROVED EQUAL. 8) GROUT TO BE USED AT ALL POINTS WHERE PIPES ENTER OR LEAVE ALL CONCRETE cTli_IrT,'� -� '.NI 'RDFP Tr PROVIDE A IA14TER"T!GHT