Loading...
BP-89696ABBREVIATIONS A AMPERE AC ALTERNATING CURRENT BLDG BUILDING CONC CONCRETE DC' DIRECT CURRENT EGC EQUIPMENT GROUNDING CONDUCTOR (E) EXISTING EMT ELECTRICAL METALLIC TUBING FSB FIRE SET —BACK GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GND GROUND HDG HOT DIPPED GALVANIZED I CURRENT Imp CURRENT AT MAX POWER Isc SHORT CIRCUIT CURRENT kVA KILOVOLT AMPERE kW KILOWATT LBW LOAD BEARING WALL MIN MINIMUM (N) NEW NEUT NEUTRAL NTS NOT TO SCALE OC ON CENTER PL PROPERTY LINE P01 POINT OF INTERCONNECTION PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA A RAINTIGHT LICENSE GEN #168572 ELEC 1136 MR MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Dartmouth ELECTRICAL NOTES 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED POWER —CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. A NATIONALLY —RECOGNIZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH ART. 110.3. 4. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED WARNING OF THE HAZARDS PER ART. 690.17. 5. EACH UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PHASE AND SYSTEM PER ART. 210.5. 6. CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH ART. 250.97, 250.92(B). 7. DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 9. MODULE FRAMES SHALL BE GROUNDED AT THE UL—LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS. GENERAL NOTES 1. ALL WORK TO BE DONE TO THE 9TH EDITION OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2017 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. UTILITY: Eversource Energy — South Shore (NSTAR—Commonwealth Electric) CONFIDENTIAL - THE INFORMATION HEREIN -0275447 00 JOBRSY6STEM: CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUSHALL ing IT BE DISCLOSED IN WHOLE OR IN w s nsertPART TO OTHERS OUTSIDE THE RECIPIENTS MOORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (1SC315B2 TESLA EQUIPMENT, WITHOUT THE WRITTEN INV PERMISSION OF TESLA INC. Delta # Solivia 5.2 TL JURISDICTION NOTES LETOURNEAU, PAUL 39 SLADES FARM LN SOUTH DARTMOUTH, MA 02748 VICINITY MAP 5.67 KW PV ARRAY PAGE NAME: COVER SHEET INDEX Sheet 1 COVER SHEET Sheet 2 SITE PLAN Sheet 3 STRUCTURAL VIEWS Sheet 4 UPLIFT CALCULATIONS Sheet 5 THREE LINE DIAGRAM Cutsheets Attached 2EV BY DATE COMMENTS I 6/27/18 SYSTEM SIZE REDUCED 6/30/18 NEW ARRAY IN MOST EFFICIENT ZONES 8/10/18 LAYOUT UPDATED Ana Laura Matias SHEET: REV: DATE- 1 C 8/10/2018 Ln c ri Q (D Q 3 r 1 vj.. — STAMPED & SIGNED FOR STRUCTURAL ONLY Hum'phre V Ka r,,i u k9i Digitally signed by Humphrey Kariuki DN: cn=Humphrey Kariuki, email=hkariuki@tesia.com, ou=ADOBE(r)-AATL, c=US, o=Tesla Inc. Date: 2018.08.21 13:29:31-04'00' CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. (E) DRIVEWAY SV Front Of Househ >z�iz w JOB NUMBER: J B-0275447 00 MOUNTING SYSTEM: ZS COmD V4 w Flashina—Insert (18) SC Std SC315132 INVERTR . Delta # Solivia 5.2 TL -or �. ��i 11i POi 4�T!d W-0 NEW=- LETOURNEAU, PAUL 39 SLADES FARM LN SOUTH DARTMOUTH, MA 02748 DESCRIPTION: 5.67 KW PV ARRAY PAGE NAME SITE P PITCH: 45 ARRAY PITCH: 45 MP1 AZIMUTH:180 ARRAY AZIMUTH:180 MATERIAL: Comp Shingle STORY. 1 St PITCH: 45 ARRAY PITCH:45 MP2 AZIMUTH:90 ARRAY AZIMUTH:90 MATERIAL: Comp Shingle STORY: 1 St PITCH: 45 ARRAY PITCH: 45 MP3 AZIMUTH:270 ARRAY AZIMUTH:270 MATERIAL: Como Shinale STORY. 1 St I FC;FND Q (E) UTILITY METER & WARNING LABEL Inv INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS DC DISCONNECT & WARNING LABELS AC AC DISCONNECT & WARNING LABELS IGM DC JUNCTION/COMBINER BOX & LABELS DISTRIBUTION PANEL & LABELS LG LOAD CENTER & WARNING LABELS O DEDICATED PV SYSTEM METER RSD RAPID SHUTDOWN 0 STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR GATE/FENCE p HEAT PRODUCING VENTS ARE RED r, _-i It11 INTERIOR EQUIPMENT IS DASHED L -"J SITE PLAN 1 III MAIN Ana Laura Matias SHEET: REV: DATE:- 2 C 8/10/2018 N W E TEE SLn (N) PV MODULE PV MODULE 5/16"x1.5" BOLT WITH 5/16" FLAT WASHER ZEP LEVELING FOOT ZEP ARRAY SKIRT ZEP MOUNTING BLOCK ZEP FLASHING INSERT (E) COMP. SHINGLE (E) ROOF DECKING 5/16" DIA STAINLESS STEEL LAG SCREW - (2-1/2" EMBED, MIN) (E) RAFTER CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. SV S1 (E) MOUNTING PLANE (MP) TYPICAL PV SIDE VIEW LOWEST MODULE JUU,)L4IVL11 I IVIVUVLLJ #_5TAN� JOB NUMBER: J B-0275447 00 MOUNTING SYSTEM: ZS Comp V4 w Flashinq—Insert (18) SC Std SC315132 INVERTER: Delta # Solivia 5.2 TL N T S INSTALLATION ORDER LOCATE RAFTER, MARK HOLE (1) LOCATION, AND DRILL PILOT HOLE. ATTACH FLASHING INSERT TO (2) MOUNTING BLOCK AND ATTACH TO RAFTER USING LAG SCREW. INJECT SEALANT INTO FLASHING (3) INSERT PORT, WHICH SPREADS SEALANT EVENLY OVER THE ROOF PENETRATION. INSTALL LEVELING FOOT ON TOP (4) OF MOUNTING BLOCK & SECURELY FASTEN WITH BOLT. LETOURNEAU, PAUL 39 SLADES FARM LN SOUTH DARTMOUTH, MA 02748 'Version #73.6 DESIGN SUMMARY 'Job*0275447 Jo site Specific Design Criteria Design Code tnportanoe Factor Ultimate Wind Speed Exposure Categall Ground Snow Load i V11t pg ASCE 7-10 10 140 mph C 30.0 psf Fig.1609A Section 26.7 ASCE Table 7-1 MPSpecific Desi n Information MP Name MP7 MP2 MP3 o . Roofing Coro Roof Comp Roof Com Roof Standoff Comp Mount SRV Comp Mount SRV Comp Moron SRV Pitch 45' 45" 45" d SLrRLL- PV 12.6 psf 12.6 psf 12.8 psf SURLL- Non-PV 23.1 psf 23.1 psf 23.1 psf Standoff S acin and Layout MP Name MP1 MP2 MP3 a X-Spacing 72" 7Z' 7Z' w X-Cantilever 24" 24" 24" Y-Spacing 41" 41" 41" -+ Y-Carnilever NA NA NA X-S acing 48" X-Candlever 21" 21" 21" Y-S ng 62" 62" 62" a Y-Cantilever NA NA r NA Layout Stagwed Staggered Staggered X and Y are maximums that are always relative to the structure framing that SUpports the PV. X is across rafters and Y is alo rafters. 5.67 KW PV ARRAY PAGE NAME: STRUCTURAL VIEWS �RFGfSTE��O \ccccccSSrONA , STAMPED & SIGNED FOR STRUCTURAL ONLY Ana Laura Matias SHEET: REV. DATE: 3 c 8/1o/2o18 T=SLn BOND (N) #8 GEC TO TWO (N) GROUND I Panel Number: LC240PC DDS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number: 7532273 Underground Service Entrance �E 200A MAIN SERVICE PANEL E;- 20OA/2P MAIN CIRCUIT BREAKER (E) WIRING CUTLER —HAMMER 20OA/2P Disconnect ♦ I (E) LOADS r I I TO 120/240V SINGLE PHASE UTILITY SERVICE 30A/2P m �/T� A — — — — � B I I N I J ~ o EGGGEC I 1 I I I � — I GEC I 1 1 1 1 I I I I I I I I Voc* = MAX VOC AT MIN TEMP !Ol (1)CUTLER—HAMMER / BR230 PV BACKFEED BREAKER Breaker, 3OA/2P, 2 Spaces —(2)Grglrtd Rod 5 8 x 8, Copper CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED JOB NUMBER: J B-0275447 SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ZS Comp V4 w Flashing-Inser ORGANIZATION, EXCEPT " US ANoEPCTIVE (18) SC Std SC315B2 TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. INVERTER: Delta_ # Solivia 5.2 TL INV 1 — (1)Delta # Solivia 5.2 TL LABEL: A INV 2 Inverter; 520OW, 240V, 97.57, PLC, Zighee, RGM INV 3 COOPER Meter Socket r I--(1)CUTLER—HAMMER p DG221URB Disconnect; 30A, 24OVac, Non —Fusible, NEMA 3R — (1)CUTLER— AMMER DG030NB Ground%Neutrol it; 30A, General Duty (DG) q--(1)CMOPER�B fLine MeterSo � Ring Type —(1)AW CAP; B—Line Meter Socket Accessory — (1) MilbankSi CL200D / Itron CIS Sdid—state Single —Phase Meter, Digital Inverter 1 IND Delta Solivia 5.2 TI_ I- I� I� I — (18)SC Std SC315B2 GEN #168572 PV Module; 315W, 294.4 PTC, 40MM, Blk Backsheet w/ Blk Interconnects, MC4, SON ZE ELEC 1136 MR Voc: 70.2 Vpmax: 58.4 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER tI)I:UJVUUII,KII - 1 x 10 EMT Conduit PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN AC I Q—(4)DeltaSolivia SmogRSS Rapid Shutdown, 60OV, 20A, NEMA 4X, MC4 I MP 2: 1x4 1 MP 3: 1x4 4_r_�j MP 1: 2x5 I -- — — — — — — — — ---Fj —(2)MULCONTACT PV—AZ84 DC 32.000018; Branch Socket; MC4 U—Joint Connector, Female — (2)MULTI—CONTACT PV—AZS4 32.0019; Branch Plug; MC4 U—Joint Connector, Male !nd ( 1) AWG i6, Solid Bare Copper ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. 2, ADDITIONAL ECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE (I )AWG 110, THWN-2, Black 4 AWG i10, PV Wire, 600V, Black Voc* = 387.86VDC Isc = 11.66 ADC 4 AWG i10, PV Wire, 60OV, Black Voc* = 310.28 VDC Isc = 5.83 ADC O � (1) aWG i10, THWN-2, Rea � (1) AWG _ (1)AWG i10, THWN-2, White NEUTRAL Vmp =240 VAC Im — O /6, Solid Bare Copper EGC VmP = 292 VDC Im =10.8 ADC O �( )AWG �, Solid Bare Copper EGC Vmp = 233.6 VDC Imp= 5.4 ADC P-21.6 AAC (1 CONDUIT KIT 1' x 10' EMT Conduit -(1)AWG 01. THWN72, Green EGC GEC — 1 Conduit Kit; 3 4' EMT ... 1 ' (1 CONDUIT KIT 1 x 10 EMT Conduit ............................. .... (.) / .............. (2 AWG i10, PV Wire, 60OV, Black Voc* = 387.86 VDC Isc = 11.66 ADC ( * . (4 AWG i10, PV Wire, 600V, Black Voc = 387.86VDC Isc = 5.83 ADC 4 (I) AWG 16, Solid Bare Copper EGC Vmp =2g2 VDC Im 10.8 ADC 1 Conduit Kit; 3 4 EMT O (1)AWG �, Solid Bare Copper EGC Vmp = 292 VDC Imp= 5.4 ADC " " " ') " / �• • . , , • , , , . (1)CONDUIT.KIT 1' x 10' EMT Conduit P= ................................ 4) AWG i10, PV Wire, 60OV, Black Voc* = 310.28 VDC Isc = 11.66 ADC • • • • ..• O (1) AWG i6, Solid Bare Copper EGC Vmp = 233.6 VDC Imp= 10.8 ADC ....... 0 CONDUIT KIT 1' x 10' EMT Conduit (2 AWG i10, PV Wire, - - - Black Voc* ......VDC Isc = 11.66 ADC © (I AWG i6, Solid Bare Copper EGC VmP = 233.6 VDC Imp= 10.8 ADC /t1r....w.aa va. z/.• — 00 LETOURNEAU, PAUL 39 SLADES FARM LN SOUTH DARTMOUTH, MA 02748 5.67 KW PV ARRAY PAGE NAME -- THREE LINE DIAGRAM DESIGN: Ana Laura Matias SHEET- REV: DATE- 5 C 8/10/2018 T-SLn CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 39 Slades Farm Ln INVERTER AND DC DISCONNECT AC DISCONNECT UTILITY SERVICE r---------------------- y(-§ I SOLAR PHOTOVOLTAIC ARRAYS) L.--------------------- - J PHOTOVOLTAIC BACK —FED CIRCUIT BREAKER IN FAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V JB-0275447-00 CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: J B-027544 7 OO CUSTOMER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR LETOURNEAU, PAUL 5.67 KW PV ARRAY Ana Laura Matins T 5 L n MOUNTING ss SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Compp V4 wFlashing—Insert 39 SLADES FARM LN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH SOUTH DARTMOUTH, MA 02748 MODULES: THE SALE AND USE OF THE RESPECTIVE (18) SC Std SC315B2 TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. INVERTER: PAGE NAME SHEET: REV: DATE - 6 Delta # Solivia 5.2 TL SITE PLAN PLACARD C 8/10/2018 Label Location: wa; _ (C)(CB)(JB) Per Code: NEC 690.31.G.3 Label Location: (DC) (INV) Per Code: NEC 690.14.C.2 AMAWNPA � • `ez9 d ��. ���tjl' i I� Label Location: (AC)(POI) Per Code: NEC 690.17.E Label Location: Label Location: (INV) (DC) (INV) a�- . ;°� Per Code: Per Code: jj'�" ' CEC 690.56(C) NEC 690.53 Label Location: (DC) (INV) Per Code: NEC 690.5(C) Label Location: (DC) (CB) Per Code: NEC 690.17(4) Label Location: (AC) (POI) Per Code: NEC 690.14.C.2 Label Location: (AC) (POI) Per Code: NEC 690.54 Label Set Label Location: (POI) Per Code: NEC 690.64.13.7 Label Location: (D) (POI) Per Code: NEC 690.64.13.4 Label Location: (POI) Per Code: NEC 690.64.13.4 Label Location: (POI) Per Code: NEC 690.17.4; NEC 690.54 Label Location: (DC) (INV) Per Code: NEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection Rapid for Delta Shutdown Device � 3.0�7.6 TL Inverters Deltas Rapid Shutdown Devices provide an automatic disconnect of 60OVDC residential or small commericial PV array system, fully compliant with the Rapid Shutdown requirements of NEC 2014 article 690.12. It is compatible with Deltas single-phase residential inverters. KEY FEATURES • NEMA 4X Protection • Compact and Lightweight • Rack Mount Installation • Fast Connect with PV Connectors • Compliant with NEC 2014 article 690.12 • PLC Communication (Model RSS-600 1-1 only) C q�l us www.delta-americas.com Model RSS-6004-2 Connection Diagram: i------------- - RAPID SHUTDOWN ON ROOF WITHIN 10 OF Pv 1 V r�6 •aa Y I •• I °f6 CoNnw1` C CH US , I I Technical Speciflcations Input Ratings Output Ratings oe vV . -------• ocw- AC SV SIGNAL 6 t r.- =' = AC AC c One onduit BREAKER GRID for all wiring I 1 • 600V DC 600V DC 20A' - 10A " N/A 15A '2 20A 20A' 25A 25A 10 AWG 12-6 AWG N/A 3/4"(two holes) PLC Signal 5V Signal Wire ' NIA;. �' ` ;. 600V' N/A 24-14 AWG General Data 7.87x691x2.09(200x150x53) 1244x1004x2.16(316x255x55) 2.861bs (1.3kg) 6 61bs (3.Okg) = MC-4 PV Connector or Amphenol H4 PV Connector MC-4 PV Connector or Amphenol H4 PV Connector �I irk �s I.-,, MC4 PV Connector or Amphenol H4 PV Connector" Screw Terminal Blocks rn -40— 158°F (40-� 70°C) 40— 158°F (�0 — 70°G) 40 - 185°F (40 - 85°C)-185°F (-40 - 85°C) .: 0-100% 0-100% t , 2000m above sea level `2000m above sea level `10 Years 10 Years Standard Compliance ;;,h,. II_ NEMA4X ;:.... NEMA4X Ui7 C' LC CS210JA227-1 NEC2014Article 690.12 NEC 2014 Article 690.12 Delta Products Corporation, Inc. 46101 Fremont Blvd. Fremont, CA 94538 Sales Email: Inverter.Sales@delta-corp.com Support Email: Inverter.Support@delta-corp.com Sales Hotline: +1-877-440-5851 or +1-626-369-8021 Support Hotline: +1-877-442-4832 Support (Intl.): +1-626-369-8019 Monday to Friday from 7am to 5pm PST (apart from Holidays) www.delta-americas.com/solarinverters1 'ag o. 0112C N1 a fi ., ..:, ,,a— ... .,..c.,. ..,..,.. 1i 1 ( i - -� Solar0ty Solarcity 1' i ft n +l w, z� Solar Inverters Transformerless (TL): 3.8 kW, 5.2 kW, 6.6 kW, 7.6 kW Wide Operating Voltage Range: 85 - 550V Wide Operating Temperature Range: -13 - 158°F (-25 - 70°C) High CEC Efficiency: 97.5% Integrated AFCI (Arc Fault Circuit Interruption) NEMA 4X plus Salt Mist Corrosion Protection Natural Convection Cooling Dual MPPT (5.2kW / 6.6kW / 7.6k" Compact and Lightweight UL 1741 / IEEE 1547 / IEEE 1547.1 / CEC ca Listed /UL 1699B(Type 1) / NEC 690.11 c - us Delta Solar Inverters Datasheet for SolarCity INPUT (DC) y...., is a '>:m . .. 4 , r 1 flominai ge 380 V FeriFr;WoR9ge"Ra ge 85 - 550 V .. uil'owei IriPPT Rang :, , g '. 200 - 500 V pi; -Us Current ' - _.s..;.- 18.OA '20.0A 20.0 Aper MPP tracker C41ax. SI1orCircuit Curier�"� 52�'�T '. ' 25.0 A per MPP tracker ax Atlowable'1mbalance Powers - 4200 W 5000 W 5600 W IlowedbC Loadklg Ratio .: 1.5 �. �C Disconnect Internal lrecker . .' N,",.�,. 72 otal nput Strings Available -.2 2 a OUTPUT(AC) 4 0 owe . ,.-,,. ...,.�... .v 3600 W 3800 W , . 5200 W 6600 W 7600 W aX Continuous Power `- F. 3000 W @ 208 V / 3300 W @ 208 V ! 5200 W @ 208 V I 66DO W @ 208 V / 6600 W @ 208 V / . 3000 W @ 240 V 3800 W @ 240 V 6200 W @ 240 V 6600 W @ 240 V 7600 W @ 240 V a age ange,-,, ll, ,. 183-228V@208V/211-264b@240V ominal Current '` 14.4A@208 V/ 15.8A@208V/ .. 24.0A@208V7 31.7A@208V/ 31.7A@208V/ �... ,. : 12.5A@240V 15.8A@240V 21.6A@240V-27.5A@240V 31.7A@240V ommaITrre uen :" 6:_ ._ 9 cY -. 60Hz requencl! ange ' 59.3 - 60.5 Hz d usta er'equency Range , - 57.0 - 63.0 Hz g Consume , ,4 a 1.5 W rota rmomcDistotiion@Nominal?'ower - -:.. <3% �- rawer a _ or� ominaf Powei _ •'_,_ ._ -.. > 0.99 djustable- ovrer`alctor,Range 77=771 0.85i-0.85c - - courti6 _oise mission " , '.y -` ' <50 db(A) @ Im GENERAL SPECIFICATION x. Elficien r ' 97.5% @ 208V / 97.5% @ 240V P9Zg Tem ange -13 - 158°F (-25-70°C) I derating above 122"F (SO-C) Datorage Tem a ure ange - 40 - 185-F (40 - 85-C) E4ax. Operetirlg Ali e 3000m above sea level MECHANICAL DESIGN e z; x inches x x torn 19.5 x 115.8 x 8.5 in(495 x 401 x 216 mm) ' -` 26.8 x 15.8 x 8.5 in(680 x 401 x 216 mm) eight ~ w� r 43.0lbs (19.5 kg) '. 65.0lbs (29.5 kg) - 9 _..�,.�,� �• _ _.,_,.'� Natural Convection Spring terminals in connection box _ mpatitile Trigg Guage ," C h '. AWG 12 - AWG 6 Copper ( According to NEC 310.15) nnedors.., 2 pairs of spring terminals in connection box ': 4 pain of spring terminals in connection box ompa le rtinIl .age C , ..-. .,. AWG 12 - AWG 6 Copper (According to NEC 690.8) oati mmunicon nterface ) ZigBee V1sP aY .: - _ �,� � 3 LEDs, 4-Une LCD cosure atena� Diecast Aluminum STANDARDS/DIRECTIVES nc osure roect on Rating . NEMA 4X, IEC 60068-2-11 Salt mist UL 1741 Second Edition, CSA C22.2 No. 107.1-01 ro.n NEC 690.35, UL 1741 CRD ` Fill- s art mg ,mtect -n' ,_ IEEE 1547, IEEE 1547.1 FCC part 15 Claw B ....a-.. =?� - ,9 UL 16998 (Type 1), NEC 690.11 ,.:. Rap d but own a. UL 1741 CRD PVRSS, NEC 690.12 (with SMART RSS) ANSI C12.1 (meet 1%Accuracy) egulahon of_ n _Supporf,,,� California Rule 21; HECO Compliant, tEEE1547 WARRANTY andard ;arm 10 years Delta Products Corporation, Inc. 46101 Fremont Blvd, Fremont, CA 94538 Sales Email: inverter.sates@deltaww.com Support Email: kweRer.support@deltaww.com Saks Hotline: +1-877-44D-5851 or +1-626-369-8021 Support Hotline: +1-877-442-4832 Support (Intl.): +1-626-369-8019 Monday to Friday from 7 am to 5 pm PST (apart from Holidays) '` t° Next -Level PV Mounting Technology 4SolarGty I ® ZepSolar Next -Level PV Mounting Technology SolarCity I ZepSolar z: ZS Comp for composition shingle roofs 4QGeMPAT�e! ~�ACOMPOV, UL LISTED zepsolar.com Description • PV mounting solution for composition shingle roofs • Works with all Zep Compatible Modules • Auto bonding UL-listed hardware creates structural and electrical bond • ZS Comp has a UL 1703 Class "A" Fire Rating when installed using modules from any manufacturer certified as "Type 1" or "Type 2" Specifications • Designed for pitched roofs • Installs in portrait and landscape orientations • ZS Comp supports module wind uplift and snow load pressures to 50 psf per UL 2703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • ZS Comp grounding products are UL listed to UL 2703 and UL 467 • ZS Comp bonding products are UL listed to UL 2703 • Engineered for spans up to 72" and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product The end -user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Document # 800-1839-001 Rev D Date last exported: April 29, 2016 11:22 AM Components zepsolar.com Mounting Block Array Skirt Part No. 850-1633 Part No. 850-1608 or 500-0113 Listed to UL 2703 1 Listed to UL 2703 Interlock Part No. 850-1388 or 850-1613 Listed to UL 2703 x a. Flashing Insert Grip Ground Zep V2 Part No. 850=1628 Part No. 850-1606 or 850-1421 Part No. 850-1511 Listed to UL 2703 Listed to UL 2703 Listed to UL 467 and UL 2703 Captured Washer Lag Part No. 850-1631-001 850-1631-002 850-1631-003 850-1631-004 Leveling Foot Part No. 850-1397 Listed to UL 2703 End Cap Part No. (L) 850-1586 or 8%1460 (R) 850-1588 or 850-1467 DC Wire Clip Part No. 850-1509 Listed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end -user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Document # 800-1839-001 Rev D Date last exported: April 29, 201611:22 AM SC-132 SERIES MODULE MORE POWER, FEWER MODULES With a sunlight to electricity conversion efficiency of over 18.8%, the module ranks amongst the highest in the industry. That means our modules can harvest more energy from the sun, which means it takes fewer of our modules to power your home. Plus, they generate more power output during the hottest times of the day, even in wanner climates. SC31562 AND SC310132 BLACK MODULE Zap Compatible 96-Cell Black -on -Black PV Module For use in residential and commercial PV installations MORE POWER PER MODULE Our 315W module generates 16% more power than a standard 270 W module. MORE ENERGY EVERY YEAR More yearly energy (kWh) compared to other modules as they perform better in the heat. MORE LAYERS, MORE POWER Manufactured by Panasonic for SolarCity, the module uses Hetero)unction cell technology, which adds a layer of thin film silicon on top of high efficiency crystalline silicon. OUTSTANDING DURABILITY With more than 20 additional tests performed beyond what is currently mandated, these modules far exceed industry standards. LEADING WARRANTY Our modules rank among the best in warranty coverage, with workmanship that extends to 15 years. C E"5 LIMITED WARRANTY Power Output 10 years (90%of P.J 25 years (80% of P.J Workmanship 15 years MATERIALS Cell Material 5 inch photovoltaic cells Glass Material AR coated tempered glass Frame Materials Black anodized aluminum CAUTION Please read the installation manual carefully before using the product. Modules are manufactured by Panasonic to the specification of SofarCity. Modules are only warranted by Panasonic if the modules are included in a PV system sold by SolarCity or Tesla. SolarCity and Tesla make no warranties related to the modules, which are sold as -is. SolarCity will handle any warranty claims on behalf of any purchaser. SOLARCITY 1146037-00-A 1 MODULE SPECIFICATIONS ELECTRICAL CHARACTERISTICS Model SC315B2 SC31092 Max Power (W) 315 310 Max Power Voltage, VMP M 58.4 58.1 Max Power Current, IMP (A) 5.40 5.34 Open Circuit Voltage, V. M 70.2 69.9 Short Circuit Current, Isc (A) 5.83 5.78 System Voltage (V) 600 600 Max Series Fuse Rating (A) 15 15 Solar Module Efficiency (%) 18.8 18.5 Power Tolerance (%) +5 / -0 +5 / -0 AT NOCT (NORMAL OPERATING CONDITIONS) Model SC315B2 SC31OB2 Max Power (W) 234.6 230.7 Max Power Voltage, VP M 53.6 53.3 Max Power Current, IMP (A) 4.37 4.33 Open Circuit Voltage, V. (V) 65.7 65.4 Short Circuit Current, 1. (A) 4.70 4.66 MECHANICAL DATA Weight 19.5kg (42.99 Ibs) Dimensions 1590 mm (62.60") / 1053 mm (41.46") / 40 mm (1.57") Connector MC4 Frame Color Black Wind and Snow Load 2400 Pa (50 Ibs/ftj Fire Type UL 1703 Type 2 11� 38 8 (1 fi31 23 Section A -A' Section 8-8' Section C-C' SOLARCITY TEMPERATURE CORRECTION NOCT CC) 49 P" (%/°C) -0.29 Voc (%/"C) -0.25 I, (%/"C) 0.03 Electrical characteristics are within-5/+10% of the indicated values of Imo, Vw, and P,u under standard test conditions (irradiance of 100 mW/cm, AM 1.5 spectrum, and a cell temperature of 25 degrees Celsius or 77 degrees Fahrenheit). AT LOW IRRADIANCE (20%) Model SC315B2 SC310132 Max Power (W) 59.7 58.6 Max Power Voltage, VMP M 55.7 55.2 Max Power Current, IMP (A) 1.07 1.06 Open Circuit Voltage, V. (V) 65.4 65.0 Short Circuit Current, Isc (A) 1.17 1.16 1146037-00-A aonsn Unit: mm (in) 2