Loading...
BP-69844T01h'N OF DARTMOUTH BUILDING DEPARTMENT APPROVEDNr�\ GENERAL NOTES SITE NAME: RUSSELLS MILLS ROAD r 1. THIS DOCUMENT IS THE CREATION, DESIGN, PROPERTY AND COPYRIGHTED WORK OF T-MOBILE. ANY DUPLICATION OR USE WITHOUT EXPRESS WRITTEN CONSENT IS STRICTLY PROHIBITED. DUPLICATION AND USE BY GOVERNMENT AGENCIES FOR THE PURPOSES OF CONDUCTING THEIR LAWFULLY AUTHORIZED REGULATORY AND ADMINISTRATIVE FUNCTIONS IS SPECIFICALLY ALLOWED. 2. THE FACILITY IS AN UNMANNED PRIVATE AND SECURED EQUIPMENT INSTALLATION. IT IS ONLY ACCESSED BY TRAINED TECHNICIANS FOR PERIODIC ROUTINE MAINTENANCE AND THEREFORE DOES NOT REQUIRE ANY WATER OR SANITARY SEWER SERVICE. THE FACILITY IS NOT GOVERNED BY REGULATIONS REQUIRING PUBLIC ACCESS PER ADA REQUIREMENTS. 3. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE T-MOBILE NORTHEAST, LLC REPRESENTATIVE IN WRITING OF DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. SPECIAL STRUCTURAL NOTES I. TOWER OWNER SHALL PROVIDE GLOBAL STRUCTURAL STABILITY ANALYSIS OF EXISTING ANTENNA SUPPORT STRUCTURE. GENERAL CONTRACTOR SCOPE OF WORK SHALL INCLUDE ALL REQUIRED STRUCTURAL MODIFICATIONS, RE -BUNDLING OF COAXIAL CABLES OR OTHER SPECIAL MODIFICATIONS AS OUTLINED THEREIN. 2. STRUCTURAL DESIGNS AND DETAILS FOR ANTENNA MOUNTS COMPLETED BY HUDSON DESIGN ON BEHALF OF T-MOBILE ARE INCLUSIVE OF THE ENTIRE ANTENNA SUPPORT STRUCTURE (GLOBAL STRUCTURAL STABILITY ANALYSIS BY OTHERS), EXISTING TOWER PLATFORM, EXISTING ANTENNA MOUNTS AND ALL OTHER ASPECTS OF THE STRUCTURE THAT WILL SUPPORT THE T-MOBILE MODERNIZATION EQUIPMENT DEPLOYMENT AS DEPICTED HEREIN. 3. HUDSON DESIGN ASSUMES THAT THE TOWER IS PROPERLY CONSTRUCTED AND MAINTAINED. ALL STRUCTURAL MEMBERS AND THEIR CONNECTION ARE ASSUMED TO BE IN GOOD CONDITION AND ARE FREE FROM DEFECTS WITH NO DETERIORATION TO ITS MEMBER CAPACITIES T-MOBILE TECHNICIAN SITE SAFETY NOTES LOCATION SPECIAL RESTRICTIONS SECTOR A: ACCESS NOT PERMITTED SECTOR B: ACCESS NOT PERMITTED SECTOR C: ACCESS NOT PERMITTED GPS/LMU: UNRESTRICTED RADIO CABINETS: UNRESTRICTED PPC DISCONNECT: UNRESTRICTED MAIN CIRCUIT D/C: UNRESTRICTED NIU/T DEMARC: UNRESTRICTED OTHER/SPECIAL: NONE 107? RUSSELLS MILLS ROAD S. DARTMOUTH, MA 02748 BRISTOL COUNTY SITE NUMBER: 4PRO482D ® 72 HOURS BEFORE YOU DIG CALL TOLL FREE 8 8 8 -DIG - SAFE UNDERGROUND SERVICE ALERT PROJECT INFORMATION SCOPE OF WORK: UNMANNED TELECOMMUNICATIONS FACILITY T-MOBILE EQUIPMENT MODERNIZATION ZONING JURISDICTION: BASED ON INFORMATION PROVIDED BY T-MOBILE, THIS TELECOMMUNICATIONS EQUIPMENT DEPLOYMENT IS AN ELIGIBLE FACILITY UNDER THE TAX RELIEF ACT OF 2012. 47 USC 1455(A), AND IS SUBJECT TO AN EXPEDITED ELIGIBLE FACILITIES REQUEST/REVIEW AND ZONING PRE-EMPTION FOR LOCAL DISCRETIONARY PERMITS (VARIANCE, SPECIAL PERMIT, SITE PLAN REVIEW). SITE ADDRESS: 1073 RUSSELLS ROAD S. DARTMOUTH, MA 02748 LATITUDE: 41' 34' 50.4798" N LONGITUDE: 71' 0' 18.3492" W JURISDICTION: NATIONAL, STATE do LOCAL CODES OR ORDINANCES CURRENT USE: TELECOMMUNICATIONS FACILITY PROPOSED USE: TELECOMMUNICATIONS FACILITY TOWER OWNER: SBA TOWERS II, LLC SBA SITE ID: MA13731-A SBA SITE NAME: PONTES DESIGN GUIDELINE: 413 DRAWING INDEX REV T-1 TITLE SHEET 0 GN-1 GENERAL NOTES 0 A-1 COMPOUND 8r, ELEVATION PLAN 0 A-2 EXISTING & PROPOSED EQUIPMENT PLANS 0 A-3 ANTENNA PLAN & DETAILS 0 G-1 GROUNDING DETAILS 0 T-MOBILE NORTHEAST LLC 15 COMMERCE WAY, SUITE B NORTON, MA 02766 OFFICE: (508) 286-2700 FAX: (508) 286-2893 SBA ID�� SBA COMMUNICATIONS CORP. 33 BOSTON POST ROAD W TEL: (508) 251-1691 MARLSOROUGH.MA01752 FAX:(508)251-1755 Hudson Design Groupuc 1600 OSGOOD STREET BUILDING 2C NORTH, : 9`RI 557-5553 N. ANDOVER, M 3365586 tiG DANIEL P. MM IVIL y .Q. 40720 c� �o APPROVALS CONSTRUCTION DATE RF ENGINEERING DATE ZONING/SITE ACQ. DATE OPERATIONS DATE TOWER OWNER DATE PROJECT NO: 4PRO482D DRAWN BY: CSM CHECKED BY: DPH 1 05/10/13 ISSUED FOR PERMrr 0 05/03/13 ISSUED FOR REVIEW SITE NUMBER: 4PRO482D SITE NAME: RUSSELLS MILLS ROAD 1073 RUSSELLS ROAD S. DARTMOUTH, MA 02748 BRISTOL COUNTY SHEET TITLE TITLE SHEET SHEET NUMBER T-1 GROUNDING NOTES THE SUBCONTRACTOR SHALL REVIEW AND INSPECT THE EXISTING FACILITY GROUNDING SYSTEM AND LIGHTNING PROTECTION SYSTEM (AS DESIGNED AND INSTALLED) FOR STRICT COMPLIANCE WITH THE NEC (AS ADOPTED BY THE AHJ), THE SITE -SPECIFIC (UL, LPI, OR NFPA) LIGHTING PROTECTION CODE, AND GENERAL COMPLIANCE WITH TELCORDIA AND TIA GROUNDING STANDARDS. THE SUBCONTRACTOR SHALL REPORT ANY VIOLATIONS OR ADVERSE FINDINGS TO THE CONTRACTOR FOR RESOLUTION. 2. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION, AND AC POWER GES'S) SHALL BE BONDED TOGETHER, AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC. 3. THE SUBCONTRACTOR SHALL PERFORM IEEE FALL -OF -POTENTIAL RESISTANCE TO EARTH TESTING (PER IEEE 1100 AND 81) FOR NEW GROUND ELECTRODE SYSTEMS. THE SUBCONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. 4. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. 5. EACH BTS CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, 6 AWG STRANDED COPPER OR LARGER FOR INDOOR BTS 2 AWG STRANDED COPPER FOR OUTDOOR BTS, 6. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. 7. APPROVED ANTIOXIDANT COATINGS (I.E., CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. 8. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE TOWER GROUND BAR, 9. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS. 10. MISCELLANEOUS ELECTRICAL AND NON -ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. 11. METAL CONDUIT SHALL BE MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH 6 AWS COPPER WIRE UL APPROVED GROUNDING TYPE CONDUIT CLAMPS. 12. ALL NEW STRUCTURES WITH A FOUNDATION AND/OR FOOTING HAVING 20 FT. OR MORE OF 1/2 IN. OR GREATER ELECTRICALLY CONDUCTIVE REINFORCING STEEL MUST HAVE IT BONDED TO THE GROUND RING USING AN EXOTHERMIC WELD CONNECTION USING #2 AWG SOLID BARE TINNED COPPER GROUND WIRE, PER NEC 250.50 GENERAL NOTES 1. FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY: CONTRACTOR - SBA COMMUNICATIONS CORP. SUBCONTRACTOR - GENERAL CONTRACTOR (CONSTRUCTION) OWNER - T-MOBILE 2. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING SUBCONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BE BROUGHT TO THE ATTENTION OF CONTRACTOR. 3. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. SUBCONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 4. DRAWINGS PROVIDED HERE ARE NOT TO BE SCALED AND ARE INTENDED TO SHOW OUTLINE ONLY. 5. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 6. "KITTING LIST" SUPPLIED WITH THE BID PACKAGE IDENTIFIES ITEMS THAT WILL BE SUPPLIED BY CONTRACTOR. ITEMS NOT INCLUDED IN THE BILL OF MATERIALS AND KITTING LIST SHALL BE SUPPLIED BY THE SUBCONTRACTOR. 7. THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 8. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE SUBCONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION SPACE FOR APPROVAL BY THE CONTRACTOR. 9. SUBCONTRACTOR SHALL DETERMINE ACTUAL ROUTING OF CONDUIT, POWER AND T1 CABLES, GROUNDING CABLES AS SHOWN ON THE POWER, GROUNDING AND TELCO PLAN DRAWING. SUBCONTRACTOR SHALL UTILIZE EXISTING TRAYS AND/OR SHALL ADD NEW TRAYS AS NECESSARY. SUBCONTRACTOR SHALL CONFIRM THE ACTUAL ROUTING WITH THE CONTRACTOR. 10. THE SUBCONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT SUBCONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. 11. SUBCONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 12. SUBCONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION 13. ALL CONCRETE REPAIR WORK SHALL BE DONE IN ACCORDANCE WITH AMERICAN CONCRETE INSTITUTE (ACI) 301. 14. ANY NEW CONCRETE NEEDED FOR THE CONSTRUCTION SHALL BE AIR -ENTRAINED AND SHALL HAVE 4000 PSI STRENGTH AT 28 DAYS. ALL CONCRETE WORK SHALL BE DONE IN ACCORDANCE WITH ACI 318 CODE REQUIREMENTS. 15. ALL STRUCTURAL STEEL WORK SHALL BE DETAILED, FABRICATED AND ERECTED IN ACCORDANCE WITH AISC SPECIFICATIONS. ALL STRUCTURAL STEEL SHALL BE ASTM A36 (Fy = 36 ksi) UNLESS OTHERWISE NOTED. PIPES SHALL BE ASTM A53 TYPE E (Fy = 36 ksi). ALL STEEL EXPOSED TO WEATHER SHALL BE HOT DIPPED GALVANIZED. TOUCHUP ALL SCRATCHES AND OTHER MARKS IN THE FIELD AFTER STEEL IS ERECTED USING A COMPATIBLE ZINC RICH PAINT. 16. CONSTRUCTION SHALL COMPLY WITH UMTS SPECIFICATIONS AND "GENERAL CONSTRUCTION SERVICES FOR CONSTRUCTION OF T-MOBILE SITES." 17. SUBCONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS MUST BE VERIFIED. SUBCONTRACTOR SHALL NOTIFY THE CONTRACTOR OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. 18. THE EXISTING CELL SITE IS IN FULL COMMERCIAL OPERATION. ANY CONSTRUCTION WORK BY SUBCONTRACTOR SHALL NOT DISRUPT THE EXISTING NORMAL OPERATION. ANY WORK ON EXISTING EQUIPMENT MUST BE COORDINATED WITH CONTRACTOR. ALSO, WORK SHOULD BE SCHEDULED FOR AN APPROPRIATE MAINTENANCE WINDOW USUALLY IN LOW TRAFFIC PERIODS AFTER MIDNIGHT. 19. SINCE THE CELL SITE IS ACTIVE, ALL SAFETY PRECAUTIONS MUST BE TAKEN WHEN WORKING AROUND HIGH LEVELS OF ELECTROMAGNETIC RADIATION. EQUIPMENT SHOULD BE SHUTDOWN PRIOR TO PERFORMING ANY WORK THAT COULD EXPOSE THE WORKERS TO DANGER. PERSONAL RF EXPOSURE MONITORS ARE ADVISED TO BE WORN TO ALERT OF ANY DANGEROUS EXPOSURE LEVELS. 20. APPLICABLE BUILDING CODES: SUBCONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL CODES AS ADOPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ) FOR THE LOCATION. THE EDITION OF THE AHJ ADOPTED CODES AND STANDARDS IN EFFECT ON THE DATE OF CONTRACT AWARD SHALL GOVERN THE DESIGN. BUILDING CODE: MA STATE BUILDING CODE 780 CMR 8TH EDITION ELECTRICAL CODE: REFER TO ELECTRICAL DRAWINGS LIGHTENING CODE: REFER TO ELECTRICAL DRAWINGS SUBCONTRACTOR'S WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING STANDARDS: AMERICAN CONCRETE INSTITUTE (ACI) 318; BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE; AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) MANUAL OF STEEL CONSTRUCTION, ASD, NINTH EDITION; TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA) 222-G, STRUCTURAL STANDARDS FOR STEEL ANTENNA TOWER AND ANTENNA SUPPORTING STRUCTURES; REFER TO ELECTRICAL DRAWINGS FOR SPECIFIC ELECTRICAL STANDARDS. FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND STANDARDS REGARDING MATERIAL, METHODS OF CONSTRUCTION, OR OTHER REQUIREMENTS, THE MOST RESTRICTIVE REQUIREMENT SHALL GOVERN. WHERE THERE IS CONFLICT BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL GOVERN. ABBREVIATIONS AGL ABOVE GRADE LEVEL G.C. GENERAL CONTRACTOR RF RADIO FREQUENCY AWG AMERICAN WIRE GAUGE MGB MASTER GROUND BUS BCW BARE COPPER WIRE MIN MINIMUM TBD TO BE DETERMINED BTS BASE TRANSCEIVER STATION PROPOSED NEW TBR TO BE REMOVED EXISTING EXISTING N.T.S. NOT TO SCALE TBRR TO BE REMOVED EG EQUIPMENT GROUND REF REFERENCE AND REPLACED EGR EQUIPMENT GROUND RING REQ REQUIRED TYP TYPICAL 14 T-MOBILE NORTHEAST LLC 15 COMMERCE WAY, SUITE B NORTON, MA 02766 OFFICE: (508) 286-2700 FAX: (508) 286-2893 SBA �D�} SBA COMMUNICATIONS CORP. 33 BOSTON POST ROAD W TEL: 1508! 251-1691 MARLBOROUGH, MA 01752 FAX:150E1251-1755 Hudson Design Groupw 1600 OSGOOD STREET BUILDING 20 NORTH, SURE 3090 TEL: 197E1557-5553 N.ANDOVER, MA01 TE1336.5536 -%H OF Algss9 DANIEL P. tiG A o I .L U 20 r ill L Rl APPROVALS CONSTRUCTION DATE RF ENGINEERING DATE ZONING/SITE ACQ. DATE OPERATIONS DATE TOWER OWNER DATE PROJECT NO: 4PRO482D DRAWN BY: CSM CHECKED BY: DPH 1 05/10/13 ISSUED FOR PERMIT 0 05/03/13 ISSUED FOR REVIEW SITE NUMBER: 4PRO482D SITE NAME: RUSSELLS MILLS ROAD 1073 RUSSELLS ROAD S. DARTMOUTH, MA 02748 BRISTOL COUNTY SHEET TITLE GENERAL NOTES SHEET NUMBER GN-1 EXISTING — EXISTING I ANTENNA EXISTING I( EXISTING T EQUIPMENT MISTING 2106 EXISTING PPC QUIPMENT CABINET EXISTING 2106 1�EQUIPMENT CABINET I I EXISTING CPS/GSM--_- ANTENNA i I � � I I EXISTING T-MO€ILE EQUIPMENT PAD (ISTING CABLE TRAY EXISTING CABLE TRAY ;ISTING 3106 )UIPMENT CABINET 4 I EXISTING 3106 PROPOSED 6102 I' I EQUIPMENT CABINET A-3 CABINET I I I I I' I I I y°�`^ , EXISTING EQUIPMENT PLAN P A-2 SCALE: 1/2"=1'-O" 0 1 -0 2'-0' 4'-0' 6--0- EXISTING EQUIPMENT PHOTO DETAIL A 2 SCALE. N.T.S EXISTING ICE BRIDGE � PROPOSED EQUIPMENT PLAN A-2 SCALE: 1/2"=1'-0" 0 1'-0" 2'-0" 4'-0- 6'-0" EXISTING ANTENNAS (BY OT- T -MOBILE NORTHEAST LLC 15 COMMERCE WAY, SUITE B NORTON, MA 02766 OFFICE: (508) 286-2700 FAX: (508) 286-2893 SBAD�}�} SBA COMMUNICATIONS CORP. 33 BOSTON POST ROAD W TEL: (508) 251-1691 MARLBOROUGH. MA01752 FAX:(SOB(251-1755 Hudson Des' ©> gn Groupuc 1600 OSGOOD STREET BUILDING 20 NORTH, SURE 3090 TP: (9781557-5553 N. ANDOVER, MAOI845 FAX: 19781336,5586 --. ( OFl�a P. CD APPROVALS CONSTRUCTION DATE EXISTING T-MOBILE ANTEEN:A7S7 RE ENGINEERING DATE EXISTING ANTENNAS (BY OTHERS) ZONING/SITE ACO. DATE EXISTING ANTENNAS (BY OTHERS) OPERATIONS DATE TOWER OWNER DATE PROJECT NO: 4PRO482 DRAWN BY: CSM CHECKED BY: DPH LO5/10/13 SITE NUMBER: 4PR0482D SITE NAME: RUSSELLS MILLS ROAD �' 1073 RUSSELLS ROAD S. DARTMOUTH, MA 02748 d �.';jn i BRISTOL COUNTY . x SHEET TITLE 0 EXISTING ANTENNA PHOTO DETAIL A-2 SCALE: N.T.S EXISTING & PROPOSED EQUIPMENT PLANS SHEET NUMBER A-2 ALPHA SECTOR EXISTING GSM/UMTS ANTENNA TO GSM/UMTS REMAIN (TYP. OF 1 PER SECTOR, TOTAL OF 3) EXISTING GSM/UMTS TMA TO REMAIN (TYP. OF 2 PER SECTOR, TOTAL OF 6) BETA SECTOR GSM/UMTS GAMMA SECTOR GSM/UMTS 1� ►5 EXISTING ANTENNA PLAN A-3 SCALE: N.T.S 0 NOTE: GENERAL CONTRACTOR TO REFER TO THE STRUCTURAL ANALYSIS BY FDH ENGINEERING, INC. AND EQUIPMENT INSTALLATION RECOMMENDATIONS PRIOR TO COMMENCING CONSTRUCTION ALPHA SECTOR GSM/UMTS/LTE NOTE: REFER TO THE FINAL RF DATA SHEET FOR FINAL ANTENNA SETTINGS. EXISTING GSM/UMTS ANTENNA TO REMAIN (TYP. OF 1 PER SECTOR, TOTAL OF 3) EXISTING GSM/UMTS TMA TO REMAIN (TYP. OF 2 PER SECTOR, TOTAL OF 6) �J BETA SECTOR GAMMA SECTOR GSM/URTS/LTE GSM/UMTS/LTE / PROPOSED ANTENNA PLAN A-3 EXISTING GSM/UMTS ANTENNA TO REMAIN (fYP. OF 1 PER SECTOR, (AL-3)TOTAL OF 3) EXISTING GSM/UMTS TMA TO — REMAIN (fYP. OF 2 PER SECTOR, TOTAL OF 6) EXISTING ANTENNA SCHEDULE SECTOR MAKE MODEL# aaF_(INCHES) ALPHA: ANDREW ADFD1820_9090B 51,7x12.1x4.5 BETA: ANDREW ADFD1820_9090B 51.7x12.1x4.5 GAMMA: ANDREW ADFD1820_9090B 51.7x12.1x4.5 PROPOSED ANTENNA SCHEDULE SECTOR MAKE MODEL# SIZE (INCHES) ALPHA: ANDREW ADFD1820_90908 51.7x12.1x4.5 BETA: ANDREW ADFD1820_9090B 51.7x12.1x4.5 GAMMA: ANDREW ADFD1820_9090B 51.7x12.1x4.5 SCALE: N.T.S. PROPOSED RBS 6102 CABINET MOUNTED TO EXISTING CONCRI SLAB PER MANUFACTURER'S REQUIREMENTS PROPOSED MODERNIZATION CABINET (TYP.) A-3 SCALE: N.T.S. T-MOBILE NORTHEAST LLC 15 COMMERCE WAY, SUITE B NORTON, MA 02766 OFFICE: (508) 286-2700 FAX: (508) 286-2893 SBA 14 SBA COMMUNICATIONS CORP. 33 BOSTON POST ROAD W TEL: (5081251-1691 MARLBOROUGH, MA 01752 FAX:1509125'-1755 *.6HudsonPr Design Groupuc OeW 1600 OSGOOD STREET BUILDING 20 NORTH. SURE 3090 TEL (9781 SS7-5553 N. ANDOVER. MA 01845 FAX: (9781336-5586 �ytN OFS DA CL P. tiG .IL to APPROVALS CONSTRUCTION DATE RF ENGINEERING DATE ZONING/SITE ACQ. DATE OPERATIONS DATE TOWER OWNER DATE PROJECT NO: 4PRO482D DRAWN BY: CSM CHECKED BY: DPH 1 05/10/13 ISSUED FOR PERMIT 0 05/03/13 ISSUED FOR REVIEW SITE NUMBER: 4PRO482D SITE NAME: RUSSELLS MILLS ROAD 1073 RUSSELLS ROAD S. DARTMOUTH, MA 02748 BRISTOL COUNTY SHEET TITLE ANTENNA PLAN & DETAILS SHEET NUMBER A-3 STAINLESS STEEL 4 HARDWARE GROUNDING CABLE ELEVATION TWO HOLE COPPER COMPRESSION TERMINAL GROUND BAR LOCK WASHER, FLAT WASHER, TYP. G () 3/8"X1-1/4" HEX EGB NUT, TYP. BOLT GROUND BAR GROUNDING EXPOSED BARE COPPER TO BE CABLE KEPT TO ABSOLUTE MINIMUM, NO SECTION "A —A" INSULATION ALLOWED WITHIN THE COMPRESSION TERMINAL (TYPICAL) NOTE: 1. "DOUBLING UP" OR "STACKING " OF CONNECTION IS NOT PERMITTED. 2. OXIDE INHIBITING COMPOUND TO BE USED AT ALL LOCATIONS. 3. CADWELD DOWNLEADS FROM UPPER EGB, LOWER EGB, AND MGB. TYPICAL GROUND BAR CONNECTION DETAIL N.T.S. THAT THE EXISTING CONDUITS ARE ADEQUATE FOR THE NG AND INCLUDE ELECTRICAL E SCOPE OF WORK AS REQUIRED. F----------- �200A-2P 60A-2P I F �� �� SURGE SECTORANTENNA R I I PPE (TYP.) Z-- ANTENNA SUPPORT TYp)UPPORT TMA (TYP. OF 6) NOTE- G.C. TO VERIFY AND WIRE SIZES PROPOSED LOADI UPGRADES IN TH TO EXISTING —� O SERVICE M 200A, 240V METER , MANUAL TRANSFER SWITCH GENERATOR RECEPTACLE L — — — — ELECTRICAL LEGEND A AMPERE V VOLT KIM KILOWATT - HOUR C CMDUT CRC CALVANZED I= CONDUT C azom i GROW NOB MASTER GROUND BAR OMECHANCAL CONNECTION EGB •COWELD CONNECTION O EOUPMENT GROUND BAR -G- GROUND COPPER ME, SIZE AS NOTED COAXIAL CABLE O- 5/6'�6' COPPER CLAD STAINLESS STEEL GROUND ROD E)-0 • OITIERMC (GAD MELD) OR 0 PPC (MECHANFiV. WO FOY" PROTECION CABINET CONE T ® OMNA-DIRECTIONAL ELECTRONIC MARKER SYSIEY (EMS) BALL iPOWER PANEL TOWER TELCO CABINET #2G UTILITY CONDUITS L LE TRAYS aEX G G G G G G cABINEr c % G EQUIPMENT PAD EGB G G MGB I I TO EXIST. GROUND CONNECTION GROUNDING RISER DIAGRAM — N.T.S. FROM ANTENNA T-MOBILE NORTHEAST LLC 15 COMMERCE WAY, SUITE B NORTON, MA 02766 WEATHERPROOFING OFFICE: (508) 286-2700 KIT (TYP.) JUMPER REQUIRED ONLY FAX: (508) 286-2893 WHEN 1-1 4"0 AND LARGER ( ) STANDARD GROUND KIT (TYP.) 6 CONNECTOR ANTENNA CABLE WEATHERPROOFING TO B TS (TYP.) A KIT (TYP.) FROM ANTENNA FRAME SUPPORT SBA COMMUNICATIONS CORP. 33 BOSTON POST ROAD W TEL:(508)251-1691 MARLBOROUGH, MA 01752 FAX:(508)251-1755 COAX GROUND KIT COMMSCOPE KIT NO. GB-0414—IT 41h. OR EQUAL Hudson Design Groupuc #2 AWG BCW 2 AWG BCW, BONDED 0 0 GROUND WIRE ALONG CABLE LADDER TO CIGBE/MIGB 1600 OSGOOD STREET N. ANDDOG ERNOR�H. SUITE3oso TEL (9781557-SS53 NOTE: A%: 19781 33656 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS �N4FAl DIRECT GROUND WIRE DOWN TO CIGBE. DAITtIEL P. yc GROUND WIRE TO GROUND�� BAR CONNECTION DETAIL I'" 0 N.T.S. GROUND LUG �--T,/�— n TO ANTENNA 7N'— APPROVALS ANTENNA GROUND ! STANDARD GROUNDING BAR (CIGBE) (TOP) KIT (TYP.) CONSTRUCTION SEE NOTE 1.11 DATE �#6 AWG (PROVIDED WITH EXISTING #2 AWG BCW LUG GROUNDING KIT TYP) 2106 (�') 50A-2P I CABINET HYBRID/COAX CABLES (TYP. FOR ALL) EXISTING 3106 80A-2P I CABINET ANTENNA GROUND BARS_ STANDARD GROUND KIT (CIGBE) (BOTTOM) SEE (TYP-) NOTE 1. PROPOSED PROPOSED I 6102 BOA-2P I CABINET #6 AWG LOG (2) #2 AWG BCW TO BTS VIA TRAY OR ICEBRIDGE 20A—iP —GFI GRADE PROPOSED CONDUIT & CONDUCTORS SERVICE GROUND PER NEC � ONE LINE POWER DIAGRAM N.T.S. ELECTRICAL & GROUNDING NOTES: 1. ALL ELECTRICAL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE (NEC) AS WELL AS APPLICABLE STATE AND LOCAL CODES. 2. ALL ELECTRICAL ITEMS SHALL BE U.L APPROVED OR LISTED AND PROCURED PER SPECIFICATION REQUIREMENTS. 3. THE ELECTRICAL WORK INCLUDES ALL LABOR AND MATERIAL DESCRIBED BY DRAWINGS AND SPECIFICATION INCLUDING INCIDENTAL WORK TO PROVIDE COMPLETE OPERATING4.. GENERAL CONTRACTOR SHALL PAY FEES FOR PERMITS, AND IS RESPONSIBLE FOR OBTAINING SAID PERMITS AND COORDINATION OF INSPECTIONS. 5. ELECTRICAL AND TELCO WIRING OUTSIDE A BUILDING AND EXPOSED TO WEATHER SMALL BE IN WATER TIGHT GALVANIZED RIGID STEEL CONDUITS OR SCHEDULE BO PVC (6. RIGID STEEL CONDUITS SHALL BE AS PERMITTED BY CODE) AND WHERE REQUIRED IN UQIAD TIGHT FLEXIBLE METAL OR NONMETALLIC CONDUITS. 7. ELECTRICAL WIRING SWV1 BE COPPER UWITH TYPENDED AT BXHHW. ENDS. N OR THIN INSULATION. B. RUN ELECTRICAL CONDOR OR CABLE BETWEEN ELECTRICAL ROOM AND ON WITH UTILITY COMPA PROPOSED CELL g� POWERPEDESTAL AS INDICATED ON THIS DRAWING. PROVIDE FULL LENGTH 9u RUN TELCO CONDUIT OR OR CABLE BETWEEN TELEPHONE UTILITY DEMARCATION POINT AND PROPOSED CELL SITE TELCO CABINET AND BTS CABINET AS INDICATED ON DRAWING A-1. PROVIDE FULL LENGTH PULL ROPE IN INSTALLED TELCO CONDUIT. PROVIDE GREENLEE CONDUIT MEASURNNG TAPE AT EACH END, 10. ALL EQUIPMENT LOCATED OUTSIDE SHALL HAVE NEMA 3R ENCLOSURE , I. GROUNDING SWILL COMPLY WITH NEC ART. 25D. 12. GROUND COAXIAL CABLE SHIELDS MINIMUM AT BOTH ENDS USING MANUFACTURERS COAX CABLE GROUNDING KITS SUPPLIED By PROJECT OWNER 13. USE 06 COPPER STRANDED WIRE WITH GREEN COLOR INSULATION FOR ABOVE GRADE GROUNDING (UNLESS OTHERWISE SPECIFIED) AND #2 SOLID TINNED BARE COPPER WIRE FOR BELOW GRADE GROUNDING AS INDICATED ON THE DRAWING. 14. ALL GROUND CONNECTIONS TO BE SURNDY HYGROUND COMPRESSION TYPE CONNECTORS R CADWELD EXOTHERMIC WELD DO NOT ALLOW BARE COPPER PARE TO BE IN CONTACT WITH GALVANIZED STEEL SENT15. AT RIGHTANGLE. UNDING CALWAYSU�KS AT �NLFAST 1H�EST AND PA P H POSSIIBLLE,AEXCEPT RADIUS OTHERWISE INDICATED. GROUNDING METAL OBJECTS WITH N�RFEBE ET OF PROPOSED EQUIPMENT OR CABINET TO MASTER GROUND BAR. #2 AWG BCW RING GROUND NOTE: 1. NUMBER OF GROUND BARS MAY VARY DEPENDING ON THE TYPE OF TOWER. ANTENNA LOCATION AND CONNECTION ANTENNA LOCATION AND CONNECTION ORIENTATION. PROVIDE AS REQUIRED. 2. A SEPARATE GROUND BAR TO BE USED FOR GPS ANTENNA IF REQUIRED. (2� ANTENNA CABLE GROUNDING \,� N.T.S. ELECTRICAL & GROUNDING NOTES (CONT.): 16. CONNECTIONS TO MGB SHALL BE ARRANGED IN THREE AWN GROUPS: SURGE PRODUCERS (COAXIAL CABLE GROUND KITS. TELCO AND POWER PANEL GROUND); (GROUNDING ELECTRODE RING R BUILDING STEEL): NON -SURGING OBJECTS (EGB GROUND IN EIS UNIT) 17. CONNECTIONS TO GROUND BARS SMALL BE MADE WITH TWO HOLE COMPRESSION TYPE COPPER LUGS. INHIBITING COMPOUND TO ALL LOCATIONS, APPLY OXIDE 16. APPLY OXIDE INHIBITING COMPOUND TO ALL COMPRESSION TYPE GROUND CONNECTIONS. 19. BOND ANTENNA MOUNTING BRACKETS. COAXIAL CABLE GROUND KITS. AND ALMA TO EGB PLACED NEAR THE ANTENNA LOCATION. 20. BOND ANTENNA EGB'S AND MGB TO WATER MAIN. 2 TEST 22. BOND COMPLETED MLTAL OBJECTS WITHIN AND RECORD OF R PROPOSED EQUIPMENT ORCABINETTO MASTER CROUNO BAR. 23. VERIFY PROPOSED SERVICE UPGRADE WITH LOCAL UTILITY COMPANY PRIOR TO CONSTRUCTION. RF ENGINEERING DATE ZONING/SITE ACQ. DATE OPERATIONS DATE TOWER OWNER DATE PROJECT NO: 4PRO482 DRAWN BY: CSM CHECKED BY: DPH _L05/10/131 ISSUED FOR PERMIT 0 05/03/13 ISSUED FOR REVIEW SITE NUMBER: 4PRO482D SITE NAME: RUSSELLS MILLS ROAD 1073 RUSSELLS ROAD S. DARTMOUTH, MA 02748 BRISTOL COUNTY SHEET TITLE GROUNDING DETAILS SHEET NUMBER G-1 C SITE NAME: RUSSELLS MILLS ROAD GENERAL NOTES 1. THIS DOCUMENT IS THE CREATION, DESIGN, PROPERTY AND COPYRIGHTED WORK OF T—MOBILE. ANY DUPLICATION OR USE WITHOUT EXPRESS WRITTEN CONSENT IS STRICTLY PROHIBITED. DUPLICATION AND USE BY GOVERNMENT AGENCIES FOR THE PURPOSES OF CONDUCTING THEIR LAWFULLY AUTHORIZED REGULATORY AND ADMINISTRATIVE FUNCTIONS IS SPECIFICALLY ALLOWED. 2. THE FACILITY IS AN UNMANNED PRIVATE AND SECURED EQUIPMENT INSTALLATION. IT IS ONLY ACCESSED BY TRAINED TECHNICIANS FOR PERIODIC ROUTINE MAINTENANCE AND THEREFORE DOES NOT REQUIRE ANY WATER OR SANITARY SEWER SERVICE. THE FACILITY IS NOT GOVERNED BY REGULATIONS REQUIRING PUBLIC ACCESS PER ADA REQUIREMENTS. 3. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE T—MOBILE NORTHEAST. LLC REPRESENTATIVE IN WRITING OF DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. � SPECIAL STRUCTURAL NOTES I. TOWER OWNER SHALL PROVIDE GLOBAL STRUCTURAL STABILITY ANALYSIS OF EXISTING ANTENNA SUPPORT STRUCTURE. GENERAL CONTRACTOR SCOPE OF WORK SHALL INCLUDE ALL REQUIRED STRUCTURAL MODIFICATIONS, RE —BUNDLING OF COAXIAL CABLES OR OTHER SPECIAL MODIFICATIONS AS OUTLINED THEREIN. 2. STRUCTURAL DESIGNS AND DETAILS FOR ANTENNA MOUNTS COMPLETED BY HUDSON DESIGN ON BEHALF OF T—MOBILE ARE INCLUSIVE OF THE ENTIRE ANTENNA SUPPORT STRUCTURE (GLOBAL STRUCTURAL STABILITY ANALYSIS BY OTHERS), EXISTING TOWER PLATFORM, EXISTING ANTENNA MOUNTS AND ALL OTHER ASPECTS OF THE STRUCTURE THAT WILL SUPPORT THE T—MOBILE MODERNIZATION EQUIPMENT DEPLOYMENT AS DEPICTED HEREIN. 3. HUDSON DESIGN ASSUMES THAT THE TOWER IS PROPERLY CONSTRUCTED AND MAINTAINED. ALL STRUCTURAL MEMBERS AND THEIR CONNECTION ARE ASSUMED TO BE IN GOOD CONDITION AND ARE FREE FROM DEFECTS WITH NO DETERIORATION TO ITS MEMBER CAPACITIES T-MOBILE TECHNICIAN SITE SAFETY NOTES LOCATION SPECIAL RESTRICTIONS SECTOR A: ACCESS NOT PERMITTED SECTOR B: ACCESS NOT PERMITTED SECTOR C: ACCESS NOT PERMITTED GPS/LMU: UNRESTRICTED RADIO CABINETS: UNRESTRICTED PPC DISCONNECT: UNRESTRICTED MAIN CIRCUIT D/C: UNRESTRICTED NIU/T DEMARC: UNRESTRICTED OTHER/SPECIAL: NONE 1072 RUSSELLS MILLS ROAD S. DARTMOUTH, MA 02748 BRISTOL COUNTY SITE NUMBER: 4PRO482D (0 72 HOURS BEFORE YOU DIG CALL TOLL FREE 8 8 8 -- D I G- SA F E UNDERGROUND SERVICE ALERT PROJECT INFORMATION SCOPE OF WORK: UNMANNED TELECOMMUNICATIONS FACILITY T—MOBILE EQUIPMENT MODERNIZATION ZONING JURISDICTION: BASED ON INFORMATION PROVIDED BY T—MOBILE, THIS TELECOMMUNICATIONS EQUIPMENT DEPLOYMENT IS AN ELIGIBLE FACILITY UNDER THE TAX RELIEF ACT OF 2012. 47 USC 1455(A), AND IS SUBJECT TO AN EXPEDITED ELIGIBLE FACILITIES REQUEST/REVIEW AND ZONING PRE—EMPTION FOR LOCAL DISCRETIONARY PERMITS (VARIANCE, SPECIAL PERMIT, SITE PLAN REVIEW). SITE ADDRESS: 1073 RUSSELLS ROAD S. DARTMOUTH, MA 02748 LATITUDE: 41' 34' 50.4798" N LONGITUDE: 71' 0' 18.3492" W JURISDICTION: NATIONAL, STATE & LOCAL CODES OR ORDINANCES CURRENT USE: TELECOMMUNICATIONS FACILITY PROPOSED USE: TELECOMMUNICATIONS FACILITY TOWER OWNER: SBA TOWERS 11, LLC SBA SITE ID: MA13731—A SBA SITE NAME: PONTES DESIGN GUIDELINE: 4B DRAWING INDEX REV T-1 TITLE SHEET 0 GNA GENERAL NOTES 0 A-1 COMPOUND & ELEVATION PLAN 0 A-2 EXISTING & PROPOSED EQUIPMENT PLANS 0 A-3 ANTENNA PLAN & DETAILS 0 G-1 GROUNDING DETAILS 0 T-MOBILE NORTHEAST LLC 15 COMMERCE WAY, SUITE B NORTON, MA 02766 OFFICE: (508) 286-2700 FAX: (508) 286-2893 SBA�� SBA COMMUNICATIONS CORP. 33 BOSTON POST ROAD W TEL: 15081251-1691 MARLBOROUGH. MA01752 F­I --- Hudson Design Groupuc 1600 OSGOOD STREET BUILDING 20 NORTH. SURE 3090 tEL 1978) 557.5553 N. ANDOVER, MA OI FAX: 1978) 336.5586 ZH OF NIEL P_ tiG HAMM IVIL CD T�Q� ai SS�O?dAL�� APPROVALS CONSTRUCTION DATE RF ENGINEERING DATE ZONING/SITE ACQ. DATE OPERATIONS DATE TOWER OWNER DATE PROJECT NO: 4PRO482D DRAWN BY: CSM CHECKED BY: DPH 1 05/10/13 ISSUED FOR PERMrT 0 05/03/13 ISSUED FOR REVIEW SITE NUMBER: 4PRO482D SITE NAME: RUSSELLS MILLS ROAD 1073 RUSSELLS ROAD S. DARTMOUTH, MA 02748 BRISTOL COUNTY SHEET TITLE TITLE SHEET SHEET NUMBER T-1 GROUNDING NOTES THE SUBCONTRACTOR SHALL REVIEW AND INSPECT THE EXISTING FACILITY GROUNDING SYSTEM AND LIGHTNING PROTECTION SYSTEM (AS DESIGNED AND INSTALLED) FOR STRICT COMPLIANCE WITH THE NEC (AS ADOPTED BY THE AHJ), THE SITE -SPECIFIC (UL, LPI, OR NFPA) LIGHTING PROTECTION CODE, AND GENERAL COMPLIANCE WITH TELCORDIA AND TIA GROUNDING STANDARDS. THE SUBCONTRACTOR SHALL REPORT ANY VIOLATIONS OR ADVERSE FINDINGS TO THE CONTRACTOR FOR RESOLUTION. 2. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION, AND AC POWER GES'S) SHALL BE BONDED TOGETHER, AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC. 3. THE SUBCONTRACTOR SHALL PERFORM IEEE FALL -OF -POTENTIAL RESISTANCE TO EARTH TESTING (PER IEEE 1100 AND 81) FOR NEW GROUND ELECTRODE SYSTEMS. THE SUBCONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. 4. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. 5. EACH BTS CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, 6 AWG STRANDED COPPER OR LARGER FOR INDOOR BTS 2 AWG STRANDED COPPER FOR OUTDOOR BTS. 6. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. 7. APPROVED ANTIOXIDANT COATINGS (I.E., CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. 8. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE TOWER GROUND BAR. 9. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS. 10. MISCELLANEOUS ELECTRICAL AND NON -ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. 11. METAL CONDUIT SHALL BE MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH 6 AWS COPPER WIRE UL APPROVED GROUNDING TYPE CONDUIT CLAMPS. 12. ALL NEW STRUCTURES WITH A FOUNDATION AND/OR FOOTING HAVING 20 FT. OR MORE OF 1/2 IN. OR GREATER ELECTRICALLY CONDUCTIVE REINFORCING STEEL MUST HAVE IT BONDED TO THE GROUND RING USING AN EXOTHERMIC WELD CONNECTION USING #2 AWG SOLID BARE TINNED COPPER GROUND WIRE, PER NEC 250.50 GENERAL NOTES 1. FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY: CONTRACTOR - SBA COMMUNICATIONS CORP. SUBCONTRACTOR - GENERAL CONTRACTOR (CONSTRUCTION) OWNER - T-MOBILE 2. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING SUBCONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BE BROUGHT TO THE ATTENTION OF CONTRACTOR. 3. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. SUBCONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 4. DRAWINGS PROVIDED HERE ARE NOT TO BE SCALED AND ARE INTENDED TO SHOW OUTLINE ONLY. 5. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 6. "KITTING LIST" SUPPLIED WITH THE BID PACKAGE IDENTIFIES ITEMS THAT WILL BE SUPPLIED BY CONTRACTOR. ITEMS NOT INCLUDED IN THE BILL OF MATERIALS AND KITTING LIST SHALL BE SUPPLIED BY THE SUBCONTRACTOR. 7. THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 8. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE SUBCONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION SPACE FOR APPROVAL BY THE CONTRACTOR. 9. SUBCONTRACTOR SHALL DETERMINE ACTUAL ROUTING OF CONDUIT, POWER AND T1 CABLES, GROUNDING CABLES AS SHOWN ON THE POWER, GROUNDING AND TELCO PLAN DRAWING. SUBCONTRACTOR SHALL UTILIZE EXISTING TRAYS AND/OR SHALL ADD NEW TRAYS AS NECESSARY. SUBCONTRACTOR SHALL CONFIRM THE ACTUAL ROUTING WITH THE CONTRACTOR. 10. THE SUBCONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT SUBCONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. 11. SUBCONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 12. SUBCONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. 13. ALL CONCRETE REPAIR WORK SHALL BE DONE IN ACCORDANCE WITH AMERICAN CONCRETE INSTITUTE (ACI) 301. 14. ANY NEW CONCRETE NEEDED FOR THE CONSTRUCTION SHALL BE AIR -ENTRAINED AND SHALL HAVE 4000 PSI STRENGTH AT 28 DAYS. ALL CONCRETE WORK SHALL BE DONE IN ACCORDANCE WITH ACI 318 CODE REQUIREMENTS. 15. ALL STRUCTURAL STEEL WORK SHALL BE DETAILED, FABRICATED AND ERECTED IN ACCORDANCE WITH AISC SPECIFICATIONS. ALL STRUCTURAL STEEL SHALL BE ASTM A36 (Fy = 36 ksi) UNLESS OTHERWISE NOTED. PIPES SHALL BE ASTM A53 TYPE E (Fy = 36 ksi). ALL STEEL EXPOSED TO WEATHER SHALL BE HOT DIPPED GALVANIZED. TOUCHUP ALL SCRATCHES AND OTHER MARKS IN THE FIELD AFTER STEEL IS ERECTED USING A COMPATIBLE ZINC RICH PAINT. 16. CONSTRUCTION SHALL COMPLY WITH UMTS SPECIFICATIONS AND "GENERAL CONSTRUCTION SERVICES FOR CONSTRUCTION OF T-MOBILE SITES." 17. SUBCONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS MUST BE VERIFIED. SUBCONTRACTOR SHALL NOTIFY THE CONTRACTOR OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. 18. THE EXISTING CELL SITE IS IN FULL COMMERCIAL OPERATION. ANY CONSTRUCTION WORK BY SUBCONTRACTOR SHALL NOT DISRUPT THE EXISTING NORMAL OPERATION. ANY WORK ON EXISTING EQUIPMENT MUST BE COORDINATED WITH CONTRACTOR. ALSO, WORK SHOULD BE SCHEDULED FOR AN APPROPRIATE MAINTENANCE WINDOW USUALLY IN LOW TRAFFIC PERIODS AFTER MIDNIGHT. 19. SINCE THE CELL SITE IS ACTIVE, ALL SAFETY PRECAUTIONS MUST BE TAKEN WHEN WORKING AROUND HIGH LEVELS OF ELECTROMAGNETIC RADIATION. EQUIPMENT SHOULD BE SHUTDOWN PRIOR TO PERFORMING ANY WORK THAT COULD EXPOSE THE WORKERS TO DANGER. PERSONAL RF EXPOSURE MONITORS ARE ADVISED TO BE WORN TO ALERT OF ANY DANGEROUS EXPOSURE LEVELS. 20. APPLICABLE BUILDING CODES: SUBCONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL CODES AS ADOPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ) FOR THE LOCATION. THE EDITION OF THE AHJ ADOPTED CODES AND STANDARDS IN EFFECT ON THE DATE OF CONTRACT AWARD SHALL GOVERN THE DESIGN. BUILDING CODE: MA STATE BUILDING CODE 780 CMR 8TH EDITION ELECTRICAL CODE: REFER TO ELECTRICAL DRAWINGS LIGHTENING CODE: REFER TO ELECTRICAL DRAWINGS SUBCONTRACTOR'S WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING STANDARDS: AMERICAN CONCRETE INSTITUTE (ACI) 318; BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE; AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) MANUAL OF STEEL CONSTRUCTION, ASO, NINTH EDITION; TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA) 222-G, STRUCTURAL STANDARDS FOR STEEL ANTENNA TOWER AND ANTENNA SUPPORTING STRUCTURES; REFER TO ELECTRICAL DRAWINGS FOR SPECIFIC ELECTRICAL STANDARDS. FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND STANDARDS REGARDING MATERIAL, METHODS OF CONSTRUCTION, OR OTHER REQUIREMENTS, THE MOST RESTRICTIVE REQUIREMENT SHALL GOVERN. WHERE THERE IS CONFLICT BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL GOVERN. ABBREVIATIONS AGL ABOVE GRADE LEVEL G.C. GENERAL CONTRACTOR RF RADIO FREQUENCY AWG AMERICAN WIRE GAUGE MGB MASTER GROUND BUS BCW BARE COPPER WIRE MIN MINIMUM TBD TO BE DETERMINED BTS BASE TRANSCEIVER STATION PROPOSED NEW TBR TO BE REMOVED EXISTING EXISTING N.T.S. NOT TO SCALE TBRR TO BE REMOVED EG EQUIPMENT GROUND REF REFERENCE AND REPLACED EGR EQUIPMENT GROUND RING REQ REQUIRED TYP TYPICAL T-MOBILE NORTHEAST LLC 15 COMMERCE WAY, SUITE B NORTON, MA 02766 OFFICE: (508) 286-2700 FAX: (508) 286-2893 SBA SBA COMMUNICATIONS CORP. 33 50STON POST ROAD W TEL: (508) 251-1691 MARLBOROUGH, MA01752 FAX:i5081251-1755 Hudson Design GroupucAW 1600 OSGOOD STREET lw BUILDING 2C NORTH. TEC 19781 S 7-5553 N. ANDOVER, 978) 336-55M DANIEL P. yG H N1 VAL cn I 4 720 4 f APPROVALS CONSTRUCTION DATE RF ENGINEERING DATE ZONING/SITE ACQ. DATE OPERATIONS DATE TOWER OWNER DATE PROJECT NO: 4PRO482D DRAWN BY: CSM CHECKED BY: DPH 1 05/10/13 ISSUED FOR PERMIT 0 05/03/13 ISSUED FOR REVIEW SITE NUMBER: 4PRO482D SITE NAME: RUSSELLS MILLS ROAD 1073 RUSSELLS ROAD S. DARTMOUTH, MA 02748 BRISTOL COUNTY SHEET TITLE GENERAL NOTES SHEET NUMBER GN-1 EXISTING PPC MISTING 2106 QUIPMENT CABINET EXISTING GPS, ANTENNA KISTING CABLE TRAY EXISTING ICE I (ISTING 3106 )UIPMENT CABINET EXISTING T—MC EQUIPMENT PA �kyh � AN EXISTING EQUIPMENT PLAN 0-�Xll.p � SCALE: 1/2"=1'-0' �\ 0 1'-0' 2'-0' 4'-0" 6'-0' EXISTING EQUIPMENT PHOTO DETAIL A 2 SCALE: N.T.S EXISTING PPC T-MOBILE NORTHEAST LLC EXISTING 15 COMMERCE WAY, SUITE B EQUIPMENTT CABINET NORTON, MA 02766 I I 1 OFFICE: (508) 286-2700 EXISTING GPS/GSM- FAX: (508) 286-2893 ANTENNA I i I I I I ' I SBA'D� I EXISTIN( T-MOBILE EQUIPMENT PAD - "" - SBA COMMUNICATIONS CORP. 33 BOSTON POST ROAD W TEL' (5081251-1691 MARLBOROUGH, MA 01751 FA)C(50912$1-1755 EXISTING CABLE TRAY ltm Hudson i Design Groupuc EXISTING 3106 PROPOSED 6102 ;I I EQUIPMENT CABINET @CABINEr i i I 16000S000DSTI I I BUILDING 20 NORTH. SU IEL 1978) $57-5553 I N. ANDOVER, M 978) 336.5586 I DANIr=L P. yc d I �. 20 _EXISTING ICE BRIDGE � EXISTING ANTENNA PHOTO DETAIL A-2 SCALE: N.T.S APPROVALS CONSTRUCTION DATE RF ENGINEERING DATE ZONING/SITE ACQ. DATE OPERATIONS DATE TOWER OWNER DATE PROJECT NO: 4PRO482 DRAWN BY: CSM CHECKED BY: DPH 1 05/10/13 ISSUED FOR PERMIT 0 65/03/13 ISSUED FOR RENEW SITE NUMBER: 4PRO482D SITE NAME: RUSSELLS MILLS ROAD 1073 RUSSELLS ROAD S. DARTMOUTH, MA 02748 BRISTOL COUNTY SHEET TITLE EXISTING & PROPOSED EQUIPMENT PLANS SHEET NUMBER A-2 ALPHA SECTOR GSM/UMTS GAMMA SECTOR GSM/UMTS EXISTING GSM/UMTS ANTENNA TO REMAIN (TYP. OF 1 PER SECTOR, TOTAL OF 3) EXISTING GSM/UMTS TMA TO REMAIN (TYP. OF 2 PER SECTOR, TOTAL OF 6) BETA SECTOR GSM/UMTS ,� 45 yo2� 1 EXISTING ANTENNA PLAN SCALE: N.T.S NOTE: GENERAL CONTRACTOR TO REFER TO THE STRUCTURAL ANALYSIS BY FDH ENGINEERING, INC. AND EQUIPMENT INSTALLATION RECOMMENDATIONS PRIOR TO COMMENCING CONSTRUCTION ALPHA SECTOR GSM/UMTSATE NOTE: REFER TO THE FINAL RF DATA SHEET FOR FINAL ANTENNA SETTINGS. EXISTING GSM/UMTS ANTENNA TO REMAIN (TYP. OF 1 PER SECTOR, TOTAL OF 3) EXISTING GSM/UMTS TMA TO REMAIN (TYP. OF 2 PER SECTOR, TOTAL OF 6) �J BETA SECTOR GAMMA SECTOR GSM/UIMATE GSM/ulm/LTE / o� 2 PROPOSED ANTENNA PLAN A-3 W2 EXISTING GSM/UMTS ANTENNA TO A-3 REMAIN (TYP. OF 1 PER SECTOR, TOTAL ()F 3) EXISTING GSM/UMTS TMA TO — REMAIN (TYP. OF 2 PER SECTOF TOTAL OF 6) EXISTING ANTENNA SCHEDULE SECTOR MAKE MODFI # SIZE (IN HF 1 ALPHA: ANDREW ADFD1820-9090B 51.7x12.1x4.5 BETA: ANDREW ADFD1820_9090B 51.7x12.1x4.5 GAMMA: ANDREW ADFD1820-9090B 51.7x12.1x4.5 OPOSED ANTENNA SCHEDULE FBETA:ANDREW KE MODEL# I F (IN�HF? DREW ADFD1820-90908 51.7x12.1x4.5 ADFD1820-9090B 51.7x12.1x4.5 GAMMA: ANDREW ADFD1820-9090B 51.7x12.1x4.5 PROPOSED RBS 6102 CABINET MOUNTED TO EXISTING CONCRI SLAB PER MANUFACTURER'S REQUIREMENTS W3�4:��PROPOSED MODERNIZATION CABINET (TYP.) SCALE: N.T.S. T-MOBILE NORTHEAST LLC 15 COMMERCE WAY, SUITE B NORTON, MA 02766 OFFICE: (508) 286-2700 FAX: (508) 286-2893 SBA 13 SBA I OMMUMCAPONS CORP. 33 BOSTON POST ROAD W TEL: (508) 25w 691 MARLBOROUGH. MA 01752 FAX:I5031251.1755 Hudson Design Groupa 1600 OSGOOD STREET BUILDING 20 NORTH, I9781 S57-5553 N. ANDOVER. _ _ w� - _ 3365596 IIEL P. yG\ �ivt �S IVIL a 40723 APPROVALS CONSTRUCTION DATE RF ENGINEERING DATE ZONING/SITE ACQ. DATE TOWER OWNER DATE PROJECT NO: 4PRO482 DRAWN BY: CSM CHECKED BY: DPH 1 105/10/131 ISSUED FOR PERMIT 0 105/03/131 ISSUED FOR REVIEW SITE NUMBER: 4PRO482D SITE NAME: RUSSELLS MILLS ROAD 1073 RUSSELLS ROAD S. DARTMOUTH, MA 02748 BRISTOL COUNTY SHEET TITLE ANTENNA PLAN & DETAILS SHEET NUMBER A-3 STAINLESS STEEL HARDWARE GROUNDING TWO HOLE COPPER COMPRESSION TERMINAL GROUND BAR LOCK WASHER, FLAT WASHER, TYP. () 3/8"x1-1/4" HEX NUT, TYP. BOLT GROUND BAR GROUNDING EXPOSED BARE COPPER TO BE CABLE KEPT TO ABSOLUTE MINIMUM, NO SECTION "A -A" INSULATION ALLOWED WITHIN THE NOTE: COMPRESSION TERMINAL (TYPICAL) 1. "DOUBLING UP" OR "STACKING " OF CONNECTION IS NOT PERMITTED. 2. OXIDE INHIBITING COMPOUND TO BE USED AT ALL LOCATIONS. 3. CADWELD DOWNLEADS FROM UPPER EGB, LOWER EGB, AND MGB. TYPICAL GROUND BAR 0 CONNECTION DETAIL NOTE- G.C. TO VERIFY THAT THE EXISTING CONDUITS AND WIRE SIZES ARE ADEQUATE FOR THE PROPOSED LOADING AND INCLUDE ELECTRICAL UPGRADES IN THE SCOPE OF WORK AS REQUIRED. TO EXISTING -J O SERVICE M 200A, 240V METER , MANUAL TRANSFER SWITCH GENERATOR RECEPTACLE ELECTRICAL LEGEND A AMPERE V VOLT KIN KLOWATT - HDIJR C CONDUIT CRC CALVAN2FD RIM CODMT C (ROUND fRD. D MGB O • MASTER WOMD BAR OMECHANIM CONNECTION EGB •CADWELD CONNECTION O • EOUPMENi GROIRO BAN -G- TR W COPPER MRE SIZE AS NOTED EXPOSED MRNG COAXIAL CABLE 0 5/r.8' IxPPFR CUD StANLESS STEEL GMI D ROD -E) 0 • EIDTIERMIC (CAD MID) OR 0 {yE�4► MEc PPC POAER PROTECNON CABINET ® OMM-DIRECTIONAL ELECRW MARKER SYSTEM (EMS) BALL 20CA- 2P 6�\2P ANTENNA SECTOR, TOTAL I P 3)I I ANTENNA SUPPORT (TYP. OF 1 PER PIPE (TYP.) TMA (TYP. OF \ G \8 EGB POWER PANEL TOWER_ _ _ _ - -- TELCO CABINET #2G UTILITY CONDCITS CABLE TRAYS PROPOSED ExIsrlNc T sto2 2106 CABINET E 3106G CABINET G G G G G caBl ET G o° 0 G EQUIPMENT PAD EGB G C MGB I I TO EXIST. GROUND CONNECTION GROUNDING RISER DIAGRAM N.T.S. - -I I ---------- EXISTING 2106 50A-2P I CABINET EXISTING 3106 CABINET BOA-2P ' PROPOSED 6102 PROPOSED CABINET 80A-2P -iP 1 _-GFI II PROPOSED CONDUIT & CONDUCTORS i_:�___SERVICE GROUND PER NEC (-4 � ONE LINE POWER DIAGRAM N.T.S. ELECTRICAL & GROUNDING NOTES: 1. ALL ELECTRICAL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE (NEC) AS WELL AS APPLICABLE STATE AND LOCAL CODES. 2. ALL ELECTRICAL ITEMS SWILL BE U.L. APPROVED OR USTED AND PROCURED PER SPECIFICATION REQUIREMENTS. 3. THE ELECTRICAL WORK INCLUDES ALL LABOR AND MATERIAL DESCRIBED BY DRAWINGS AND SPECIFICATION INCLUDING INCIDENTAL WORK TO PROVIDE COMPLETE OPERATING AND APPROVED ELECTRICAL SYSTEM. 4. GENERAL CONTRACTOR SHALL PAY FEES FOR PERMITS, AND IS RESPONSIBLE FOR OBTAINING SLID PERMITS AND COORDINATION OF INSPECTIONS. 5. ELECTRICAL AND TELCO WIRING OUTSIDE A BUILDING AND EXPOSED TO WEATHER SHALL BE IN WATER TIGHT GALVANIZED RIGID STEEL CONDUITS OR SCHEDULE 80 PVC (AS PERMITTED BY CODE) AND WHERE REQUIRED IN LIQUID TIGHT FLEXIBLE METAL OR NONMETALLIC CONDUITS. 6. RIGID STEEL CONDUITS SHALL BE GROUNDED AT BOTH ENDS. S. 7. ELECTRICAL ELECTRICAL CONDUIT OR CABLE BETWEEBE COPPER WITH N ELECTRICAL ROOM AND PROPOSEDCELLCqy SITE POMPANY.OWER PEDESTAL AS INDICATED ON THIS DRAWING. PROVIDE FULL LENGTH 9U UN�TELCOOCONDUIT OR CABLEON WITH BETWEEN TELEPHONE UTILITY DEMARCATION POINT AND PROPOSED CELL SITE TELCO CABINET AND BTS CABINET AS INDICATED ON DRAWING A-1. PROVIDE FULL LENGTH PULL ROPE IN INSTALLED TELCO CONDUIT. PROVIDE CREENLEE CONDUIT MEASURING TAPE AT EACH END. TO. ALL EQUIPMENT LOCATED OUTSIDE SHALL HAVE NEMA 3R ENCLOSURE. 11. GROUNDING SHALL COMPLY WITH NEC ART. 250. 12. TH ENDS USING 13. USE #6 COPPER STRANDED UND COAXIAL CABLE (WIRE MINIMUM GREEN COLOR INSULATION FORABOVEGRADE GROUNDING (RS COAX CABLE �UNLESSGKITS OTHERWISE%SPECFlE)PROJECT AND /2 SOLID TINNED BARE 11P4.ALL GROUND CONNNEECCTIONNS TOGREGBEUBURNDY HYGRO DDCOMPRESSION ON THE WTYPE CONNECTORS OR CADWTTD D. DO NOT ALLOW BARE COPPER WIRE TO BE IN CONTACT WITH GALVANIZED STEEL EXOTHERMIC WEt 15. ROUTE GROUNDING CONDUCTORS ALONG THE SHORTEST AND STRAGNTEST PATH POSSIBLE, EXCEPT AS OTHERWISE INDICATED. GROUNDING LEADS SHOULD NEVER BE BENT AT RIGHT ANGLE. ALWAYS MAKE AT LEAST 12' RADIUS BENDS. #6 WIRE CAN BE BENT AT 6' RADIUS WHEN NECESSARY. BOND ANY METAL OBJECTS WITHIN 7 FEET OF PROPOSED EQUIPMENT OR CABINET TO MASTER GROUND BAR. FROM ANTENNA 7�,� JUMPER REQUIRED ONL WHEN 1-1/4"0 AND LARGER ( .) CONNECTOR WEATHERPROOFING KIT (TYP.) FROM ANTENNA - FRAME SUPPORT KIT (TYP.) STANDARD GROUND KIT (TYP.) ANTENNA CABLE TO STS (TYR.) COAX GROUND KIT -COMMSCOPE KIT NO. GB-0414-IT OR EQUAL AWG BCW, BONDED GROUND ?LE LADD RRTOALONG C GBE/MIGB NOTE: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO CIGBE. GROUND WIRE TO GROUND BAR CONNECTION DETAIL #2 AWG BCW N.T.S T-MOBILE NORTHEAST LLC 15 COMMERCE WAY, SUITE B NORTON, MA 027766 OFFICE: (508) 286-2700 FAX: (508) 286-2893 SBA SBA COMMUNICATIONS CORP. 33 BOSTON POST ROAD W TEL I508) 251-1691 MARLBOROUGH, MA 01752 FAX:I5081251.1755 Hudson Design Group. 1600 OSGOOD STREET BUILDING 2C NORTH, IEL 9781 557-5553 N. ANDOVER, 61bQI '978)336-5586 DANIEL P. 40720 GROUND LUGAISTANDARD ENNA v ANTENNA GROUND (CIGBE) (TOP)KIT SEE NOTE 1.RFENGINEERINGDATE GROUNDINGBAR (TYP.)CONSTRUCTION APPROVALS DATE #6 AWG (PROVIDED WITH#2j G BCW LUGGROUNDING KIT TYP) ZONING SITE ACID. DATE HYBRID/COAX CABLES (TYP. FOR ALL) OPERATIONS DATE ANTENNA GROUND BAR (CIGBE) (BOTTOM) SEE NOTE 1. STANDARD GROUND KIT (TYP.) TOWER OWNER DATE PROJECT NO: 4PRO482 DRAWN BY: CSM I #6 AWG LOG (2) #2 AWG BCW CHECKED BY- DPH TO BTS VIA TRAY OR ICEBRIDGE GRADE #2 AWG BCW RING GROUND - - 1 105/10/131 ISSUED FOR PERMIT NOTE: 0 05/0 /131 ISSUED FOR REVIEW 1. NUMBER OF GROUND BARS MAY VARY DEPENDING ON THE TYPE OF TOWER. ANTENNA ANDAND CONNECTION RATION IC NTATION. PROVIDECAS REQUIRED.ANTENNLOCATION SITE NUMBER: 4PR04826 SITE NAME: RUSSELLS 2. A SEPARATE GROUND BAR TO BE USED FOR CPS ANTENNA IF REQUIRED. MILLS ROAD ANTENNA CABLE GROUNDING S.DAR RUSSELLS ROAD . ARTMOUTH, MA 02748 - N.T.S. BRISTOL COUNTY SHEET TITLE ELECTRICAL & GROUNDING NOTES (CONT.): GROUNDING DETAILS 16. CONNECTIONS TO MGB SHALL BE ARRANGED IN THREE MAIN GROUPS: SURGE PRODUCERS (COAXIAL CABLE GROUND KITS, TELCO AND POWER PANEL GROUND); (GROUNDING ELECTRODE RING OR BUILDING STEEL); NON -SURGING OBJECTS (EGB GROUND SHEET NUMBER IN BTS UNIT) 17. CONNECTIONS TO GROUND BARS SHALL BE MADE WITH TWO HOLE COMPRESSION TYPE COPPER LUGS. APPLY OXIDE INHIBTTING COMPOUND TO ALL LOCATIONS. 18. APPLY OXIDE INHIBITING COMPOUND TO ALL COMPRESSION TYPE GROUND CONNECTIONS. 19. BOND ANTENNA MOUNTING BRACKETS, COAXIAL CABLE GROUND KITS, AND ALMA TO EGB PLACED NEAR THE ANTENNA LOCATION. /� _ 1 20. BOND ANTENNA EGO'S AND MGB TO WATER MAIN. V 21. TEST COMPLETED GROUND SYSTEM AND RECORD RESULTS FOR PROJECT CLOSE-OUT DOCUMENTATION. 22. BOND ANY METAL OBJECTS WITHIN 7 FEET OF PROPOSED EQUIPMENT OR CABINET TO MASTER GROUND BAR. 23. VERIFY PROPOSED SERVICE UPGRADE WTTH LOCAL UTILITY COMPANY PRIOR TO CONSTRUCTION.