BP-67994ROOF PENETRATION
JUNCTION BOX
STRING A °
A2 Al A7 B2 -
J I
-7
A3 A4 A5 A6 B1
o °
PHOTOVOLTAIC SYSTEM NOTES
1. SOLAR PV SYSTEM CAPACITY : 5.61 KW
2. QUANTITY AND TYPE OF PV MODULES — (22) LG 255S1C—G2
3. PV ARRAY CONFIGURATION: (1) ARRAY OF. (1) STRING
(7) MICRO —INVERTERS PER STRING
(1) MODULE PER MICRO —INVERTER
(1) ARRAY OF. (1) STRING
(8) MICRO —INVERTERS PER STRING
(1) MODULE PER MICRO —INVERTER
(1) STRING
(7) MICRO —INVERTERS PER STRING
(1) MODULE PER MICRO —INVERTER
4. MAXIMUM STRING CURRENT (lac): (215W X 11 MODULES)/24OVac = 9.85Aac
5. STC VOLTS (Operating Voltage): 37.2Vdc
6. PV ARRAY TILT. 35 DEGREES
7. PV ARRAY ORIENTATION: 177 DEGREES
8. PROVIDE NAME PLATE READING "CO —GENERATION DISCONNECT °
ARRAY CONDUIT AND WIRE MANAGEMENT
1. USE-2; FREE -AIR/ Y" CONDUIT SLEEVE** FOR WIRING BETWEEN ARRAY MODULES (2) #10 AWG.
**PROVIDE CONDUIT SLEEVE FOR WIRING BETWEEN ARRAY PANELS AS PER NEC 300.13 & 300.18.
its PsDEI
1r
T 19 j
11: 5
AC COMBIN�R
INDOOR ENCLOSED
MAIN CIRCUIT BREAKER
(BASEMENT)
ROOF PENETRATION REVENUE
JUNCTION BOX METER
STRINGS B & C
UTILITY
M
T_ I I I I DISCONNECT
B3 B4 B5 B6 B7 B8 C7 (E) UTILITY
LMETER
(E ) MAIN SERVICE
PANEL
(BASEMENT)
C1 C2 C3 C4 C5 C6
INS
J.
r r ',
il
MODULE SPECS
�l� 411
138.82" [—
Al 64. 511
SOLULAR, LLC.
20 STOW ROAD
MARLTON, NJ 08053
PHONE: 609-268-8880
PA Do
ld
I`
It's deg n Zvi ,
PHOTOVOLTAIC SYSTEM DESIGN DRAWINGS
SCHEDULE OF REVISIONS
9/5/12
j ORIGINAL DRAWING
DATE
DESCRIPTION OF CHANGES
DRAWN BY: MBB CHECKED BY: JG
NJ CERT OF AUTH. 264141920
c
0Mco
ti
wU)o
N � �
OCv�_
w w M
00
J D
T TIN
1 11
ER
4
s 1 :, • h f "� DRAWING TITLE:
A Cc 19y a 1 SITE PLANS
Plan ,!`'Fst s Y.c,)ppl �
111y' IMISS�"�e' iO
E.
ou Nif 9�RAWING SHEET:
1. PV MODULE OPEN CIRCUIT VOLTAGE (Voc) = 37.2V
2. PV MODULE MAX POWER VOLTAGE (Vmp) = 30.OV
3. PV MODULE SHORT CIRCUIT CURRENT (Ise) = 8.85A
4. PV MODULE MAX POWER CURRENT (Imp) = 8.5A
PHOTOVOLTAIC SYSTEM DESIGN DRAWINGS
JOSEPH GIGANTIELLO, P.E.
Ni PROFESSIONAL ENGINEER LIC. 991804
PA PROFESSIONAL ENGINEER LIC. OPEO]SOt1
MA PROFESSIONAL ENGINEER LIC. 19892
i
i
16'-7" L
29'-6"
68'-7"
L %6' I.D. L-FOOT
SS SPLIT -LOCK WASHER
D D %g" I.D. X Y8" O.D.
SS FENDER WASHER
J
14'-2"
6" X %s" HANGER BOLT
1%4" I.D. x %„ O.D. Xy8 O BLOCK
® EPDM FLAT WASHER
211�1.-2 %s' HEX NUT
(TVP)
%s" i.D. X %4" 0 D. FLASHING
EPDM BONDED SS
D SEALING WASHER
GENERAL MOUNTING NOTES
1. PV MODULES SHALL BE MOUNTED ON ALUMINUM RACKING
2. LAG SCREWS SHALL BE 1F X 3"
3. RAIL MUST EXTEND 3" BEYOND MODULES
6. THERE MUST BE AT LEAST 121" BETWEEN THE END OF THE RAIL AND
THE OUTSIDE EDGE OF THE END CLAMP
7. L-FOOT SHALL BE LOCATED WITHIN V FROM ANY SPLICE
8. WEIGHT OF PV MODULES AND RACKING SHALL BE LESS THAN 5 PSF
ROOF 1 MOUNTING DETAILS
1. RAFTERS ARE 2X8 @ 24" OC WITH A 13'-0" MAX SPAN
2. L-FOOT SHALL BE LOCATED_34" FROM THE END OF THE RAIL.
BLOCKING MAYBE NECESSARY.
3. L-FEET SHALL BE INSTALLED AT <_48" APART
ROOF
2X8 @ 24" O.C.
13' MAX SPAN
D
31„ ROOF 2 MOUNTING DETAILS
-
FOR FOR LG 255SC1 PANELS: �- 91 -� 1. ....RAFTERS ARE 4"X4.5" @ 37" OC WITH A 12'-0" MAX SPAN
I'D" MUST BE BETWEEN 61" and 154" � 1161 If 2. L-FOOT SHALL BE LOCATED 534" FROM THE END OF THE RAIL.
I2BLOCKING WILL BE NECESSARY.
1
3. L-FEET SHALL BE INSTALLED AT 38" APART (AND NOT MORE
IRONRIDGE IRONRIDGE uaj
MID CLAMP EXAMPLE END CLAMP EXAMPLE 3" THAN 48" APART)
MODULE MODULE MODULE
ROOF
4"X4.5" @ 37" O.C.
IRONRIDGE IRONRIDGE 12' MAX SPAN
PHOTOVOLTAIC SYSTEM DESIGN DRAWINGS
SOLULAR, LLC.
20 STOW ROAD
MARLTON, NJ 08053
PHONE: 609-268-8880
Jim_
1.
it's clean vines,
PHOTOVOLTAIC SYSTEM DESIGN DRAWINGS
SCHEDULE OF REVISIONS
915/12
ORIGINAL DRAWING
DATE
DESCRIPTION OF CHANGES
DRAWN BY: MBB I CHECKED BY: JG
NJ CERT OF AUTH. 264141920
00
0 W h
W J O
W
W y
o
aN
a
NeN-®
r
DRAWING TITLE:
MOUNTING
DETAILS
DRAWING SHEET:
6EC (#8)
3#10,1 #8G,1 "C
ENPHASE CABLE ENPHASE ENGAGE
DROP CONNECTORS INTERCONNECTION
CABLE
(E) UTILITY
(4#12)
CABLE BRANCH
ENPHASE ENGAGEVENPHASEGROINVERTER:
GRID TIED MICRO -INVERTER #1 -#22 SERVICE
MANUFACTURER:ENPHASE
TERMINATOR
MODEL: M215
MAXIMUM DC VOLTAGE: 240V
GEc wa)cEC lna) N
RATED INVERTER CAPACITY (WAC): 215
ES PER
RATED PANEL CAPACITY (W): 255
tSOLADECK
RATED MICRO -INVERTER INPUT CAPACITY (WGc): 260
MIVERTERS AC/DC
RATED AC VOLTAGE: 120/240
BOX
RIN0:7 ROOF BOX
OPERATING CURRENT:.0.9A
d
ULSO
UL 1741 LISTED O (E) UTILITY
10A/2P (TYP)
STRING: A
IEEE 1547 LISTED METER
TIE PV ARRAY BACK FEED INTO
INCOMING UTILITY FEED BETWEEN
THE METER AND THE MAIN BREAKER
ENPHASE CABLE ENPHASE ENGAGE
DROPCONNECTORS
INTERCONNECTION
CABLE
ENPHASE ENGAGE
- (4#12)
CABLE BRANCH
TERMINATOR
GEC OIa) V
GEC(#a)
^v
6#10,1#8G,1"C
ENPHASE
MODULES PER
MICROINVERTER:-1
MICROINVERTER
MICROINVERTERS
MCB
M215 PER STRING: 8
STRING. B
0 OPEN SPACES
- ENPHASE CABLE - ENPHASE ENGAGE
DROP CONNECTORS INTERCONNECTION
SOLADECK
AC10C
3#4,1#6G,11"C
N
- CABLE
ROOF BOX
ENPHASE ENGAGE -
4#12
( )
UL50 TYPE 3R
CABLE BRANCH
10A/2P (TYP)
<<-
G
TERMINATOR
PANELUARE D)
OLE
GEC fus> ti
GEC ti
-
120 24 VO T PHASE
MODULES PER
MAIN CIRCUIT BREAKER RATING: 100A
.ENPHASE
MICROINVERTER t
MICROINVERTER
M215
MICROINVERTERS -
PERSTRING: 7
EXISTING
STRING* c
GROUND WIRE
)) )) ))
1
6OA
N
INDOOR ENCLOSED.
G
60A/2P MAIN CIRCUIT
-
Gy
N
1 Prp
I6ArzP
mArzP
AC COMBINER
BREAKER(LOCKABLE)
GENERAL ` NOTES
(E) MAIN HOUSE
1. BOND PV SYSTEM AND PV RAIL ASSEMBLY TO SERVICE ELECTRODE.
3#4,1#6G,1-1"C GROUNDING SYSTEM
2. CONNECT AC TO CUSTOMER SERVICE NA 60A/2P BACKFEED BREAKER.
3#10,1#8G,1"C
3. ELECTRICAL INSTALLATION SHALL COMPLY WITH NEC 2011
UTILITY
SUNRUN SMART
SUNRUN
REVENUEMETER
N
G DISCONNECT
4. INVERTER SHALL COMPLY WITH UL 1741 AND IEEE 1547.
SMART
LUGS MUSTACCEPT
O
30AS
25AF
(LOCKABLE)
METER MONITORING
METER
SIZE #1oawGWIRE
NEMA3R
5. PROVIDE NAME PLATE ON DC DISCONNECT IN ACCORDANCE WITH NEC 690.53.
6. ALL WIRING SHALL BE COPPER UNLESS OTHERWISE NOTED.
3#10,1#8G,1"C
CONDUCTOR DESIGNATION BY CONDITION
CONDITION
- ALLOWABLE CONDUCTOR TYPE(S)
USE-2/RHW-2 -
FREE AIR
' (SUNLIGHT RESISTANT)
RACEWAY
- THWN-2 OR XHHW-2 OR RHH/RWH-2
ROOFTOP
RACEWAY OR
THHN OR THWN OR XHHW'
CABLE INDOORS
RACEWAY
UNDERGROUND
THHN OR THWN OR XHHW'i
'MAY SUBSTITUTE "-T RATED CONDUCTORS
SOLULAR,LLC.
20 STOW ROAD
MARLTON, NJ 08053
PHONE: 609-268-8880
L '
A
it's clean Living
PHOTOVOLTAIC SYSTEM DESIGN DRAWINGS
SCHEDULE OF REVISIONS
9/S/12
ORIGINAL DRAWING
DATE
DESCRIPTION OF CHANGES
DRAWN BY: MBB I CHECKED BY: JG
NJ CERT OF AUTH. 264141920
0
U W
W J O
3 Q
LU
w y
W N m
0C
6
N N �
r
DRAWING TITLE:
ELECTRICAL
SINGLE LINE
DRAWING SHEET:
Emmi
JOSEPH GIGANTIELLO, P.E.
NJ PROFESSIONAL ENGINEER LIC. #41604
PHOTOVOLTAIC SYSTEM DESIGN DRAWINGS
PA PROFESSIONAL ENGINEER LIC. NPE079011
MA PROFESSIONAL ENGINEER LIC. #49692
ROOF1 ROOF2
GENERAL NOTES
1. ROOF ACCESS 24' LADDER
2. ATTIC ACCESS - HATCH WITH PULL -DOWN LADDER
3. CHECK SUPPORT STRUCTURE IN ATTIC FOR "ROOF 2" TO ENSURE
THAT REINFORCING COLLAR TIES WERE INSTALLED PRIOR TO INSTALLATION
PHOTOVOLTAIC SYSTEM DESIGN DRAWINGS
SOLULAR, LLC.
20 STOW ROAD
MARLTON, NJ 08053
PHONE: 609-268-8880
�
it's dean tieing
i
PHOTOVOLTAIC SYSTEM DESIGN DRAWINGS
SCHEDULE OF REVISIONS
915N2
j ORIGINAL DRAWING
DATE
I DESCRIPTION OF CHANGES
DRAWN BY: MBB I CHECKED BY: JG
NJ CERT OF AUTH. 264141920
DRAWING TITLE:
I
PICTURES/NOTES
DRAWING SHEET:
GRID TIED INVERTER #
MANUFACTURER:
MODEL:
MAXIMUM DC VOLTAGE:
RATED INVERTER CAPACITY (W AC):
RATED ARRAY CAPACITY (W):
RATED INVERTER INPUT CAPACITY (WDC):
RATED AC VOLTAGE:
OPERATING CURRENT:
RATED MAX POWER -POINT VOLTAGE:
RATED MAX POWER -POINT CURRENT:
DC OPERATING VOLTAGE:
DC SHORT CIRCUIT CURRENT:
UL 1741 LISTED
AC COMBINER PANEL
FOR
PHOTOVOLTAIC SYSTEM
NOTE: NO OTHER
CIRCUITS TO BE INSTALLED
IN THIS PANEL
LOCATION: INVERTERS LOCATION: AC COMBINER
DC DISCONNECT AC DISCONNECT
FOR FOR
PHOTOVOLTAIC SYSTEM PHOTOVOLTAIC SYSTEM
J WARNING
ELECTRIC SHOCK HAZARD!
DC VOLTAGE IS ALWAYS PRESENT WHEN
PV MODULES ARE EXPOSED TO SUNLIGHT
! WARNING
ELECTRIC SHOCK HAZARD!
DO NOT TOUCH TERMINALS.
TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE
ENERGIZED IN THE OFF OR OPEN POSITION
LOCATION: INVERTERS LOCATION: ALL.EQUIPMENT
NOTICE
MULTIPLE ELECTRICAL POWER SOURCES
PROVIDE POWER TO THIS BUILDING
ELECTRICAL POWER IS PROVIDED BY THE
FOLLOWING SOURCES:
1) UTILITY SERVICE
2) PHOTOVOLTAIC SYSTEM
LOCATION: DC DISCONNECT LOCATION: AC DISCONNECT LOCATION: UTILITY LOCATION: UTILITY EQUIPMENT
DSICONNECT AND MAIN PANEL
CAUTION SOLAR CIRCUIT i WARNING
PHOTOVOLTAIC METER
LOCATION: EVERY 10' ON INVERTER OUTPUT CONNECTION
CONDUIT RUNS
DO NOT RELOCATE THIS
OVERCURRENT DEVICE
LOCATION: REVENUE GRADE LOCATION: MAIN CIRCUIT
METER BREAKER FOR PV SYSTEM
PHOTOVOLTAIC SYSTEM DESIGN DRAWINGS
PHOTOVOLTAIC UTILITY
DISCONNECT
SOLULAR, LLC.
20 STOW ROAD
MARLTON, NJ 08053
PHONE: 609-268-8880
';. P A
Ws chars liven
PHOTOVOLTAIC SYSTEM DESIGN DRAWINGS
SCHEDULE OF REVISIONS
915112
ORIGINAL DRAWING
DATE
DESCRIPTION OF CHANGES
DRAWN BY: MBB I CHECKED BY: Jr
NJ CERT OF AUTH. 264141920
00
LLI
v M ti
W U) O
N .3 .4
LLI
WV)2
W N
0
U)N®
r
DRAWING TITLE:
LABELS
DRAWING SHEET:
GENERAL NOTES
1. RAFTERS ARE 4 X 42" @ 37" O.C.
36"
2. 2X4 COLLAR TIES ARE TO BE INSTALLED 8" BELOW
0
RIDGE ON EACH PAIR OF ADJOINING RAFTERS.
2X4 COLLAR TIE
8" (TYP)
3. DO NOT INSTALL PANELS ON ROOF 2 UNTIL
INSTALLATION OF SPECIFIED STRUCTURAL 47°
REINFORCEMENT HAS BEEN CONFIRMED.
(E) 4" x 41' (E) 4" X 42,
RAFTER RAFTER
4. ATTIC SPACE CAN BE ACCESSED VIA A HATCH WITH (TYP) (TYP)
PULL -DOWN LADDER ON SECOND FLOOR.
37" O.C.
(Typ)
'ATTIC SPACE
(E) 4" X 4z l 28 -2
RAFTER -
(TYP)
2ND FLOOR
PHOTOVOLTAIC SYSTEM DESIGN DRAWINGS
SOLULAR,LLC.
20 STOW ROAD
MARLTON, NJ 08053
PHONE: 609-268-8880
If
JAL
�N
r_
it's clean (wino
PHOTOVOLTAIC SYSTEM DESIGN DRAWINGS
SCHEDULE OF REVISIONS
915112
ORIGINAL DRAWING
DATE
DESCRIPTION OF CHANGES
'
DRAWN BY: MBB CHECKED BY: JG
NJ CERT OF AUTH. 264141920
DRAWING TITLE:
STRUCTURAL
REINFORCEMENT