Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BP-80511
ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER —CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY —RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET —BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED ' HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. 1 CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC ' LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING P01 POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER INDEX Voc VOLTAGE AT OPEN CIRCUIT VICINITY MAP W MATT 3R NEMA 3R, RAINTIGHT -� 4 T PV1 COVER SHEET 1,4 a PV2 SITE PLAN _� PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES4� Pv5 THREE LINE DIAGRAM 1. ALL WORK TO BE DONE TO THE STH EDITION���°� , ��� q� Cutsheets Attached � �Z ELEC 1136 MR OF THE MA STATE BUILDING CODE.� GEN #168572• �\ 2. ALL ELECTRICAL WORK SHALL COMPLY WITH ` ` r 0` rt ' �"A. THE 2014 NATIONAL ELECTRIC CODE INCLUDING �,01 �'�.� 'x r ,� �_, �fi�, MASSACHUSETTS AMENDMENTS. ,y r MODULE GROUNDING METHOD: AHJ: Dartmouth X �W ��" REV BY DATE COMMENTS "ate s4WNAME DATE COMMENTS rP 1; UTILITY: NSTAR Electric (Boston Edison) CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: J B-0 2 7 3 7 2 9 O 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT E USED FOR THE MILTON CAMPBELL Milton Campbell RESIDENCE Andrew Merolillo � BENEFIT SHALL ANYONE EXCEPT IN WHOLE INC., MOU m SYSTEM: ���'-. SolarCity. NOR SHALL R BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 65 WHITE —OAK —RUN C PART TO OliIERS OUTSIDE THE RECIPIENTS p %� 6.89 KW PV ARRAY 01N ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES N DARTMUTH, MA 02747 THE SALE AND USE OF THE RESPECTIVE (26) Hanwho Q—Cells # Q.PRO G4/SC 265SOLAR24 St. Martin Drive, Building 22, Unit 11 PERMISSION EQUIPMENT, WITHOUT THE WRITTEN INVERTER: C ZG PAGE NAME: SHEET: REV: DATE: Marlborough, MA 013Qj PERMISSION OF SOLARCITY INC. 5086367721 COVER SHEET T: (650) 638-1028 F. (650) (638-1029 SOLAREDGE SE5000A—USOOOSNR2 PV 1 2/22/2016 (BBB)-SGL—CITY (765-2489) wwnr.solarcity.com A\ss AL F� Digitally signed by Humphrey Kariuki Date: 2016.02.22 17:30:28-05'00' Front Of House PITCH: 20 ARRAY PITC;H:20 MPi AZIMUTH:146 ARRAY AZIMUTH: 146 MATERIAL: Comp Shingle STORY: 2 Stories V2156UN 11 �1 (E) UTILITY METER & WARNING LAPEL Inv INVERTER W/ INTEGRATED DC [DISCO & WARNING LABELS © DC DISCONNECT & WARNING LAABELS AC DISCONNECT & WARNING LAABELS 1-01 DC JUNCTION/COMBINER BOX F8c LABELS OD DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER, 0 STANDOFF LOCATIONS ® CONDUIT RUN ON EXTERIOR — — — CONDUIT RUN ON INTERIOR GATE/FENCE 0 HEAT PRODUCING VENTS ARE FRED 1 � ^, INTERIOR EQUIPMENT IS DASHED L =�J SITE PLAN 41 Scale: 1/8" = 1' 01' 8' 16'I] WESNA F s CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER: J B-0273729 00 PREMISE OWNER: DESCRIPTION: MILTON CAMPBELL Milton Campbell RESIDENCE DESIGN: Andrew Merolillo BENEFIT OF ANYONE EXCEPT SOLARCITY INC., 65 WHITE —OAK —RUN 6.89 KW PV ARRAY �,J��S���IC��t�/ MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH N DARTMUTH MA 02747 MODULES: 24 St. Martin Drive, Boiilding 2, Unit 11 SHEET: REV: DATE: THE SALE AND USE OF THE RESPECTIVE (26) Hanwha Q—Cells # Q.PRO G4/SC 265 PAGE NAME Modborough, MIA 01752 T. (650) 638-1028 F:: ((650) 638-1029 INVERTER: SOLAREDGE SE5000A—USOOOSNR2 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. 5086367721 SITE PLAN PV 2 2/22/2016 (868)—sot.—CITY (765-24") www.solarcity.corn A SIDE VIEW OF MP1 NTS MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" STAGGERED PORTRAIT 48" 19" TOP CHORD 2X4 @ 24" OC BOT CHORD 2X4 @24" OC ROOF AZI 146 PITCH 20 STORIES: 2 ARRAY AZI 146 PITCH 20 Comp Shingle PV MODULE 5/16" BOLT WITH LOCK & FENDER WASHERS ZEP LEVELING FOOT ZEP ARRAY SKIRT ZEP COMP MOUNT C ZEP FLASHING C (E) COMP. SHINGLE (E) ROOF DECKING 5/16" DIA STAINLESS STEEL LAG BOLT WITH SEALING WASHER (2-1/2w EMBED, MIN) (E) RAFTER CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL. NOT BE USED FOR THE BENEFIT OF ANY04E EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: JB-0273729 00 MOUNTING SYSTEM: Comp Mount Type C (26) Hanwha Q—Cells # Q.PRO G4/SC 265 INVERTER: SOLAREDGE #SE500OA—USOOOSNR2 INSTALLATION ORDER (1) E, LOCATERAFTER, MARK HOLE LOCATION, AND DRILL PILOT HOLE. (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. (3) INSERT FLASHING. (4) PLACE MOUNT. (5) INSTALL LAG BOLT WITH SEALING WASHER. (6) INSTALL LEVELING FOOT WITH BOLT & WASHERS. MILTON CAMPBELL 65 WHITE —OAK —RUN N DARTMUTH, MA 02747 5086367721 DESCRIPTION: Milton Campbell RESIDENCE 6.89 KW PV ARRAY PAGE NAME: STRUCTURAL VIEWS Q \SCv1YI� �/L� I WAIPSIM I * O- Andrew Merolillo SHEET: REV: DATE:- PV 3 2/22/2016 �,solarCity. 24 St. Martin Drive, Building Z Unilt 11 Marlborough, MA 01752 T: (650) 638-1028 F. (650) 638Z:1O29 (888)—SOL—CITY (765-2489) www.solmrcitycom UPLIFT CALCULATIONS SEE SEPARATE PACKET FOR STRUCTURAL CALCULATIONS. CONFIDENTIAL — 'THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYJNE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTSORG THE AS TALE AND USEEOF PT ITHE RES RESPECN CONNECTION TIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: J B-0 2 7 3 7 2 9 00 PREMISE OWNER: DESCRIPTION: MILTON CAMPBELL Milton Campbell RESIDENCE 65 WHITE —OAK —RUN 6.89 KW PV ARRAY N D AR TM U TH MA 02747 PAGE NAME 5086367721 UPLIFT CALCULATIONS DESIGN: Andrew Merolillo ■ ���r • olar dry ► MOUNTING SYSTEM: Comp Mount Type C MODULES:- (26) Hanwha Q—Cells # Q.PRO G4/SC 265 24 St. Martin Drive, Building 2 Umit 11 Marlborough, MA 01752 T. (650) 638-1028 F. (650) 638-1029 (88B�SDI-CITY (765-2489) www.adtarcity.com SHEEP REV. DATE PV 4 2/22/2016 INVERTER. SOLAREDGE SE5000A—USOOOSNR2 BOND (N) #8 GEC TO TWO (N) GROUND (Panel Number: ODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number: 7044085 Underground Service Entrance E 200A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER (E) WIRING rirnrD_ueuurD Voc* = MAX VOC AT MIN TEMP POI )CUTLER—HAMM —H 30A/E2P# 2 230esPV BACKFEED BREAKER Brea—(2)Gro qd Rod 5%8 x 8, Copper INV 1 INV 2 INV 3 INVERTER SPECS (1) SOLAREDGE JSE5000A-USOOOSNR? LABEL: A Inverter; 50 OW, 240V, 97.57.; w Unifed Disco and ZB,RGM,AFCI (1) CUTLER —HAMMER # DG221URB Disconnect; 30A, 240Voc, Non —Fusible, NEMA 3R — (1) CUT ER—(IAMMER ! DG03ONB Ground//NNeutral Kit; 30A, General Duty (DG) Inverter 1 SOLAREDGE SE5000A-USOOOSNR2 24W IIIN GC_ — — LI —(26)Hanwho Q-Cells # Q.PRO G4 /SC 265 L;tN #115`8572 PV Module; 265W, 241.3W PTC, 40mm, Blk Frame, H4, ZEP, 11000V ELEC 113% MR VOC: 38.01 Vpmax: 30.75 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN we O3 (I )AWG #10, THWN-2, Black ( 1 ) AWG #10. THWN-2, Red (I) AWG 010, THWN-2, White NEUTRAL Vmp =240 VAC Imp=21 AAC ...... - (1) AWG 0,. TH_WN-2,. Green . , EGC/GEC - (1) Conduit. Kit:. 3/4' .EMT......... . (1)Conduit Kit; 31,C EMT PV ( QSOLAREDGE JP300-2NA4AZS D� PowerBox ptimizer, 30OW, H4, DC to DC, ZEP Solid Bare Copper and (1) AwG /6, — ( 11 Ground Rod; 5/8" x 8'. Copper N) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. T, ADDITIONAL LECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF ((E) ELECTRODE O (2)AWG 110, PV Wire, 60OV, Black (1)AWG 16, Solid Bare Copper EGC Voc* = 500 Vmp = 350 VDC VDC Isc =15 ADC Imtp=10.46 ADC ........ (1)Conduit Kit; 3/4'.EMT........... O2 (2)AWG /10, PV Wire, 60OV, Black 14i ( 1 ) AWG /6, Solid Bare Copper EGC L.:JL_ (1) Conduit Kit:. 3/4' EMT Vo.............................. c* = 500 Vmp = 350 VDC VDC Isfc = 15 ADC Ifmp= 8.97 ADC —THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE NUMBER: J B-0273729 00 PREMISE OWNER: DESCRIPTION: DESIGN: BENEFIT F BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MILTON CAMPBELL Milton Campbell RESIDENCE Andrew Merolillo ��Al, Sour MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type c 6 5 WHITE —OAK —RUN AK— R U N 6.89 KW PV ARRAY •aS ►�� J �� PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH N DARTMUTH MA 02747 MODULES 24 St. Martin Drive, Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (26) Hanwho Q—Cells # Q.PRO G4/SC 265 INVERTER: SOLAREDGE sES000A—us000sNR2 SHEET: REV: DATE PV 5 2/22/2016 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISS".IIN OF SOLARCITY INC. PACE NAME: 508636772� THREE LINE DIAGRAM Marlborough, MA 101752 T: (650) 630-1028 F: (6;50) 638-1029 (8B8)—SOL-CITr(765-2469) hvrasdareity.com Label Location: (C)(CB) Per Code: NEC 690.31.G.3 Label Location: (DC) (INV) Per Code: NEC 690.14.C.2 Label Location: (DC) (INV) Per Code: NEC 690.53 Label Location: (DC) (INV) Per Code: NEC 690.5(C) Label Location: (DC) (CB) Per Code: NEC 690.17(4) Label Location: (AC) (POI) Per Code: NEC 690.14.C.2 Label Location: (AC) (POI) Per Code: NEC 690.54 Label Location: (AC)(POI) Per Code: NEC 690.17.E Label Location: (POI) Per Code: NEC 690.17.4; NEC 690.54 Label Location: (POI) Per Code: NEC 690.64.B.4 Label Location: (D) (POI) Per Code: NEC 690.64.B.4 Label Location: (POI) Per Code: NEC 690.64.B.7 Label Location: (DC) (INV) Per Code: NEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR 11K.1 wI 3055 Clearview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED •- San Mateo, CA 1440, IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, Label Set oil T:(650) 6 (765-2 89) w) .solar ;3t EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE �� SolarCity. (888) SOL-CITY(765-2489)wwwsolarc:�y,C SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. ^SOlafCity I ® pSolar Next -Level PV Mounting Technology $OlafCity I ® pSolar Next -Level PV Mounting Technology Zep System for composition shingle roofs #� Yi e around Zep Interlockl% sdr LewUng foot 36, \\1 4L Roof Attachment - . RGOMPgT� e`er Description PV mounting solution for composition shingle roofs FA °OMPps�v Works with all Zep Compatible Modules Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class "A" Fire Rating when installed using modules from UL LISTED any manufacturer certified as "Type 1" or "Type 2" Specifications • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72" and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain zepsolar.com This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end -user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of ZepSolaes products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Document # 800-1890-001 Rev A Date last ex ported: November 13, 2015 2:23 PM Components Leveling Foot Part No. 850-1172 ETL listed to UL 467 Comp Mount Part No. 850-1382 Listed to UL 2582 Mounting Block Listed to UL 2703 Interlock Part No. 850-1388 Listed to UL 2703 zepsolar.com Ground Zep V2 Part No. 850-1511 Listed to UL 467 and UL 2703 Array Skirt, Grip, End Caps Part Nos. 850-0113, 850-1421, 850-1460,850-1467 Listed to UL 1565 DC Wire Clip Part No. 850-1448 Listed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end -user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Document # 800-1890-001 Rev A Date last exported: November 13, 2015 2:23 PM solar. =@" solar=@@SolarEdge Power Optimizer Module Add -On for North America P300 / P350 / P400 P300 P350 (for 60-cell PV (for 72•cell PV (for 96•cell PV modules) :modules) modules) I L--� :.INPUT Rated Input DC Power": ....................... 350....................... W.. Absolute Maximum Input Voltage (Voc at lowest temperature) ..........399 48 60 SO Vdc MPPT Operating Range ............................................... ......... B"48..................... $.:60............ ......... 8-80......... .... Vdc Maximum Short Circuit Current (Isc) ..........................10 Adc Maximum DC Input Current 12S ...................................... . Adc ...................................................................................... Maximum Efficiency ..............................99:5 ...................................... . ...;M...... ................................................................................. Weighted Efficiency 98.8 .................................................... % Overvoltage Category OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) ;. Maximum Output Current ................................. 15 ....................................... Adc .... ........ .................... Maximum Output Voltage 60 Vdc :.OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltaee Der Power Optimizer 1 1 Vdc ::STANDARD COMPLIANCE_ EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 ............................................................................................................................................................................ . Safety .................................................... ...............IEC62109-1(claI.I. s.a..fe.ty...), UL3741 ............ RoHS Yes :INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage . 1000 Vdc. Dimensions (WxLx H) 141x212x40:5:SSx8,34z159 . .... ./S. .. .. . mm/in ................................................................... Weight (including cables) 2.1 gr / Ib Input Connector ................................................................... ... ........................... MC4 / Amphenol /_Tyco..,,...,..........,.,...,. . ............ Output Wire Type /Connector Double Insulated; Amphenol Output Wire Length....It ............................................... ....... �:95 3:........�....................... 1:Z./_3:9 ..n.! .. Operating Temperature Range -+185 ......................................... . . Y / �F.... .................................................................... Protection ................................ I.................... Rating. IP65 / NEMA4 ............................................................................................... ..................... Relative Humidity ....................................................................................................................................................................... wx.r�a src powe, ortne moame. Movie a �a <o+sx powo, romans snowed. 0 - 300 % A PV SYSTEM DESIGN USING A SOLAREDGE , . `I N SINGLE PHASE THREE PHASE . ,THREE PHASE .��� 'INVERTER208V . � 480Vr' Minimum String Length (Power Optimizers) ...................P.................................................................................................................................. 8 30 18 .................... g Maximum Strin Len th (Power O timizers .................................................. 25 .......... 25 50 ............ ........... ..... Maximum Power per String ........................................... 525D ............ 6000 ........... 12750 .......... W..... Parallel Strings of Different Lengths or Orientations Yes i The new Q.PRO-G4/SC is the reliable evergreen for all applications, with a black Zep Compatible TM frame design for improved aesthetics, opti- mized material usage and increased safety. The 4t6 solar module genera- tion from Q CELLS has been optimised across the board: improved output yield, higher operating reliability and durability, quicker installation and more intelligent design. INNOVATIVE ALL-WEATHER TECHNOLOGY • Maximum yields with excellent low -light and temperature behaviour. • Certified fully resistant to level 5 salt fog ENDURING HIGH PERFORMANCE • Long-term Yield Security due to Anti PID Technology', Hot -Spot Protect, and Traceable Quality Tra.Q`M • Long-term stability due to VDE Quality Tested - the strictest test program. SAFE ELECTRONICS • Protection against short circuits and thermally induced power losses due to breathable junction box and welded cables. THE IDEAL SOLUTION FOR: Rooftop arrays on residential buildings PROFIT -INCREASING GLASS TECHNOLOGY • Reduction of light reflection by 50%, plus long-term corrosion resistance due to high -quality • Sol -Gel roller coating processing. EXTENDED WARRANTIES • Investment security due to 12-year product warranty and 25-year linear performance warranty2. ' APT test conditions: Cells at -1000V against grounded, with conductive metal foil covered module surface, 25°C, 168h z See data sheet on rear for further information. Engineered in Germany Format 65.7 in x 39.4 in x 1.57 in (including frame) (1670 mm x 1000 mm x 40 mm) Weigh .._ 44.09 lb (20.0 kg). " Front Cover 6.13 in (3.2 mm) thermally pre -stressed glass with anti reflection technology " Back Cover Composite film uaoo°.a Frame Black anodized ZEP compatible frame Cell 6 x 10 polycrystaltine solar cells Junction box Protection class IP67, with bypass diodes °xpn1 Cable 4 mma Solar cable; (+) t47.24 in (1200 mm), O >47.24 in (1200 mm) Connector Amphenol, Helios H4 (IP68) ,.os=�,..° I ©I°'v°"'•' ' z. PERFORMANCE AT STANDARD TEST CONDITIONS (STC: 1000 WIM�,.25°C, AM 1.5 G SPECTRUM)' _. _ ..._. .265 POWER CLASS (+5 W/-O W) IWl 255.:. 260 Nominal Power Ps IW] 255 260 265 ' Short Circuit Current IK [A] 9.07 9.15 9.23 j Open Circuit Voltage_ -.. ... V. IV] _..... 37.54 .. .__..._._ ,,.. _. 37.77 .... 38.01 Current at P,,,, IaPP [A] 8.45 8.53 8.62 ; Voltage at P11Pe VMee IV] 30.18 30.46 30.75 ' Efficiency (Nominal Power) rl [%] >_ 15.3 t 15.6 a 15.9 POWER CLASS (+5W/-O W) [W1 255 260 265"., Nominal Power Pa,P IWI 188.3 192.0 195.7 Short Circuit Current lsc [A] 7.31 7.38 7.44 Open Circuit Voltage Vns IV] _. _ ----- 34.95 35.16 35.38 Current at P,,,, IwP [A] 6.61 6.68 6.75 Voltage at P_ VMPe IV] 28.48 28.75 29.01 ' Measurement tolerances STC::3 % (P,); m 10 %0I , Va, Imp„ V) ' Measurement tolerances NOCT: f5% (P-p°); t10 % fly, V , 1_, Vm ) At least 97 %of nominal power during a �•--n--r--r--r--r--r--r--r--) z �� >. - ib��.m,o-�.,N.a u�N....m firs[ year. Thereafter max. 0.6% degra- a ' ' ' i<o • _ ______________ cation per year. 3a , At least 92 Y of nominal power after W 10 years. ____ ,o W W � At least 83 % of nominal power after > --r--� 25 years. : • - r _ � i i All data within measurement tolerances. Full warranties in accordance with the I ' warranty terms of the Q CELLS sales zoo aoo .ao sn em r�IRRADIANCE IW/m'] x.._,...,.s organisation of your respective country. The typical change in module efficiency at an irradiance of 200 W/m' in relation a to 1000 W/m' (bath at 25'C and AM 1.5G spectrum) is -2 % (relative). °mrxnMr, ucrrr�rr r� 1Mr lei Mm r.�u arc�rnu,nr . , OCEllS ` Temperature Coefficient of Im a [%/Kl +0.04 Temperature Coefficient of Vw p [%/Kl -0.30 TOP BRAND PV - Temperature Coefficient of P_ V [%/Kl -0.41 NOCT PFI 113 t 5.4 (45 t 3°C)' U2;0�15 Maximum System Voltage Vsss IV] 1000 (IEC) / 1000 (U QSafety Class II _------ Maximum Series Fuse Rating [A DC] 20 Fire Rating C / TYPE 1 Max Load (Uq' [lbslWl 50 (2400 Pa) Permitted module temperature -40°F up to +185 °F on continuous duty (-40°c up to+85°C) Phntnn. Load Rating (UL)s [lbs/ft'] 50 (2400 Pa) see installation manual QualHy Tested QCfLLi .1., pol,cryaglline _ 7 Iacmod* 2013 . I UL 1703; VDE Quality Tested; CEcomplianQ Number of Modules per Pallet 26 °'Px-235 ` IEC 61215 (Ed.2); IEC 61730 (Ed.l) application class A - ---------'- 1 10.40032587 Number of Pallets per 53' Container _32 �OMeal eP Number o1 Pallets per 40' Comainer 26 ,OMPgT70A e pVE C E -r % W Pallet Dimensions ILxWxH) 687inx450inx46.0in H� !� &s„' '�O • _ (1745 x 1145 x 1170 mm) Pallet Weight. , .. ,. 1254 lb (569 kg) ' �FA Q,v NOTE: Installation instructions must be followed See the installation and operating manual or contact our technical service department for further information on approved installation and use of COMP 'A this product. Warranty void if non-ZEP-certified hardware is attached to groove in module frame. Hanwha 0 CELLS USA Corp. 300 Spectrum Center Drive, Suite 1250, Irvine, CA 92618, USA I TEL+1 949 748 59 96 1 EMAIL gcells-usa@gcells.com I WEB www.q-cells.us CELLS Engineered in Germany Q;CELLS solar= SolarEdge Single Phase Inverters For North America SE3000A-US / SE380OA-US / SE5000A-US / SE6000A-US / SE760OA-US / SE1000OA-US / SE11400A-US � r The best choice for SolarEdge enabled systems Integrated arc fault protection (Type 1) for NEC 2011 690.11 compliance Superior efficiency (98%) +' Small, lightweight and easy to install on provided bracket Built-in module -level monitoring Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter,DC/AC conversion only Pre -assembled Safety Switch for faster installation Optional - revenue grade data, ANSI C12.1 ' USA - GERMANY - ITALY - FRANCE -JAPAN -CHINA - AUSTRALIA -THE NETHERLANDS - ISRAEL www.solaredge.us Single Phase Inverters for North America solar =cc SE3000A-US / SE380OA-US / SE5000A-US / SE6000A-US / SE760OA-US / SE1000OA-US / SE1140OA-US SE3000A-US 1 SE380OA-US OUTPUT::: Nominal AC Power Output 3000 3800 5000 6000 .................................................................... 9980 @ 208V 7600 11400 1DOD0 @240V VA .......................................................................................... Max. AC Power Output 3300 4150 5400 @ 208V 6000 8350 10800 @ 208V 12000 VA ........................................................... 5450 @240V.................. ................. 10950.@240V AC Output Voltage Min: Nom.-Max pl 183 - 208 - 229 Vac AC Output Voltage Min.-Nom: Max.(') J 211-240-264Vac AC Frequency Min,-Nom: Max.('I.... ........... .... '.. .•.59.3-60-60.5.(with.HI country setting .57-,60.: 60.5)............. _..... _._,._._.. . Hz .... Max. Continuous Output Current... ...-- 12.5......I...-.16.....I..21,@240V...I,,,,,,.25,.,,,,I,,....32..,.__. 24 @ 208V 48 @ 208V .„42 .@, 240V _........ 47.5 A GFDI Threshold ...........................................................1 A..... Utility MnnitorinP. Isla nd ine Protection. Country Confieurable Thresholds Yes Yes Maximum DC Power(STCI 4050.--..I.... 5100.....�..... 6750......'..... 8100._...I.... 30250.....�..... 13500......1.. _.. 15350.._..., W..... ........................ ................. Transformer.less, Ungrounded ........................................................................................................................................................ ....... Yes Max.Input Voltage............................................................................... 500 ........................................................... . Vdc.... Nom. DC Input Voltage ................. ... 325@208V/3S0@240V,.,,..... ............... ........ _._....,., ....... Vdc Max. Input Currently) jjII jjII ........................9 5......I ......13 ......I..1S5 @ 240V..I.......18 ...... 1......73.......1.. 30 5.(°�Z?4.OV........ 34.5..........Adc.... ......................... Max. Input Short Circuit Current ......................................................................................................................................................... 45 Adc Reverse -Polarity Protection ................................................................................. Yes...................................................................... Ground -Fault Isolation Detection 600ko Sensitivity ..Maximum Inverter EHiciencY................97.7.... ...98.2...........98:3............98:3..... .......98...............98................98............ %..... CECWeighted Efficiency ........................................... . ....97.5............98......I.998 240V........97.5..... .....97.5........9,7. @�240V........97.5...........%..... Nighttime Power Consumption <2.5 _ <4 W Supported Communication Interfaces _ RS485, RS232, Ethernet. ZigBee (optional) Revenue Grade Data, ANSI C12 1 Optionail 'I Rapid Shutdown NEC 2014 690.12 Functionality enabled when SolarEdge rapid shutdown kit Is Installed) 1 STANDARD COMPLIANCE . Safety .................................... U L1741, U L1699B, U L1998, CSA 2 2. 2 Grid Connection Standards IEEE1547................................................................. ........................................................................................ Emissions _ FCC part15 class B AC output conduit size /AWG range 3/4" minimum / 16-6 AWG ...../ 16-................................................................................... I 3/4" minimum / 8-3 AWG ......................................................................mini DC input conduit size / # of strings / 3/4" minimum / 1-2 strings / 16-6 AWG 3/4" minimum / 1-2 strips g AWG.2ng@..................... ....... ....................... .............-...... I ........... 14-6 AWG..... ......... , . Dimensions with Safety Switch 30.5 x 12.5 x 7.2 / 775 x 315 x 184 30.5 x 12.5 x 10.5 / in / JlHp)............................................................................................................................. 775 315 x x 260............. mm.... Weight with Safety Switch ....................... 51.2 / 23.?..........I...................54:7/.24.7.................. ............ 88:4 / 40.1 ............. lb /.kg... Natural convection Cooling Natural Convection and internal Fans (user replaceable) fan (user replaceable)................................ .................................................... I............................ I............................ . Noise < < 50 .....................................................................25 ............................................................................. Min. -Max. Operating Temperature -13 to+140 / 25 to+60 (40 to+60 version available(')) Rang?....................................................................................................................................................... Protection Rating NEMA 3 ..................................................................................................R........................................................... p) For other regional settings please contact SolarEdge support. (� A higher current source may be used, the inverter will limit its input current tothe values stated. plRevenue grade inverter P/N: SE —A US000NNR2 (for 76DOW nverter 5E7600A-US002NNR2). (41 Rapid shutdown kit P/N: SE1000-RSD 51. (5) -40 version P/N: SE —A US000NNU4 (for 760OW inverter.SE7600A-U5002NNU4).