Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BP-73271
RESIDENTIAL ❑ Phased Approval (R106.3.3) 1.1 Property Address: Contact Person: Phone Number:. "jG - 3J - / 4 1.4 Water Supply (MGL c40 s54): 1.5 Sewage Disposal System: ❑ Municipal ❑ Municipal ❑ Private Well ❑ On Site Disposal System 1.2 Assessors Map & Lot Number: _ > Map _33 Lot v 1.3 Historical District ❑ Yes ❑ No Year Built ❑ Altering more than 25% per side of building Has application been submitted to the Historic Commiission? ❑ Yes ❑ No Date: ❑ CONSTRUCTION PLANS ❑SITE PLAN Revised 5 /13 ❑ ENERGY REPORT RESIDENTIAL 2.1 Owner Record: �C, Name (ptittt) JJ �- Q a z/ 2.2(A{tporized Agent: e� Name (print) 5 -4 y -- 7 <"T 1-/ Contact Address Phone Number G-a ( �" (G (,--N 5'3r) — /`/off Contact Address Phone Number 3.1 Licensed Construction Supervisor/Specialty License: tli., 'i V� `Lciv, License Number: C S 7 Company Name/Contractor Name: �+ S Address: -e-4 L Expiration Date: 5 y Signature: Telephone: 3.2 Homeowner Exemption - One & Two Family Only Section 110.R5.1.3.1 Exception: FOR HOMEOWNERS WHO INTEND TO PERFORM AND BE RESPONSIBLE FOR THEIR OWN PROJECT Exception: Any Homeowner performing work for which a Building Permit is required shall be exempt from the provisions of this section; provides that if a Homeowner engages a person(s) for hire to do such work, that such Homeowner shall act as supervisor. For the purposes of this section only, a "Homeowner" is defined as follows: Person(s) who owns a parcel of land on which he/she resides or intends to reside, on which there is, or is intended to be, a one or two family dwelling, attached or detached structures accessory to such use and/or farm structures. A person who constructs more than one home in a two-year period shall not be considered a Homeowner. Worker's Compensation Insurance Affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached: ❑ Yes ❑ No ❑ Deck ❑ Pool ❑ Repairs ❑ Alteration ❑ Chimney/Fireplace ❑ Woodstove/Pellet Stove ❑ New Construction" ❑ Accessory Bldg. ❑ Addition ❑ Roofing/Siding ❑ Replacement window/door (Energy report required) (Shed/Garage) (Energy report required) No. of windows Doors ❑ DEMOLITION (specify): Location of debris removal (per MGL C.40 Sec 54): ❑ Dumpster on site Facility Name: Location: "If new construction, please complete the following: Single Family: No. of Bedrooms No. of Baths Two Family: No of Bedrooms Unit 1 No. of Baths Unit 1 No of Bedrooms Unit 2 No. of Baths Unit 2 ❑ Furnace (hot air) - fuel gas (natural or propane), fuel oil, electricity, other (specify): _ ❑ Boiler (heating) - fuel gas (natural or propane), fuel oil, electricity, other (specify): _ ❑ HVAC (combined unit) - primary fuel, natural gas, propane, electricity, other (specify): ❑ Air conditioning - (separate unit) ❑ None of the above to be provided ❑ Hot Water: Gas Electric Fuel Oil ❑ Dumpster On Street Other Item Estimated Cost ($) to be completed by permit applicant 1. Building 3 V-t,. a — 2. Electrical Xvo 3. Plumbing 4. Mechanical (HVAC) 5. Total =(1 +2+3+4) /0.u0 (Please Print) I, as Owner of the subject property hereby authorize A k" cC. rt "e-, to act on my behalf, in all matters relative to work authorized by this building permit application. Signature of Owner Date y -c/ as Owner/Authorized Agent hereby declare that the statements and infolrmation on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Signature of Total Permit Fee: $ Agent Gross Area - New Construction total sq. ft. Gross Area - I Permit Issue Less Application Fee: $25.00 Other $ Amount $ Date Remaining Balance: $/ � �G 1 2 3 4 I 5 A B C PHOTOVOLTAIC SYSTEM SCOPE OF WORK: INSTALLATION OF A SAFE AND CODE -COMPLIANT GRID -TIED SOLAR PV SYSTEM ON AN EXISTING RESIDENTIAL ROOF TOP. SYSTEM SIZE: AC / DC kW STC: 5.19 kW / 6 kW EQUIPMENT: PV MODULES: (24) ET SOLAR ET-P660250BB INVERTER(S): (1) POWER -ONE PVI-6000-OUTD-US-A (240V) IFF � 7Z �1 SITE PLAN N SCALE: 1/64" = V-0" 1 I I I I I I I v (E) SFD I n Ij z 1 (E) DRIVEWAY i t I I I I I ` \ I I FOR INSTALLER USE ONLY POST INSTALL SUNEYES REQUIRED? YES ❑ NO I CERTIFY THAT NO CHANGES HAVE BEEN MADE TO THE SITE PLAN DETAIL N SCALE: 3/32" = V-0" CONDUIT RUN ON EXTERIOR WALL CONDUIT RUN THROUGH ATTIC SHEETINDEX PV0.0 COVER AND SITE PLAN PV1.0 GENERAL NOTES PV2.0 ARRAY LAYOUT PV3.0 LINE DIAGRAM PV4.0 CALCULATIONS PV5.0 LABELS KEY: ---- PROPERTY LINE E3 SUSPANELL - - --- CONDUIT RUN E OC DISCONVNECT DRIVEWAY SOLAR MODULE Ac AC DISCWNNECT MAIN MAIN SERVICE PANEL El JUNCTIONI�gOX M UTILITY METER ❑P MONITORItNG UNIT ® PV METER c9 COMBINEM BOX Q INVERTER ROOF OBSTRUCTION APPLICABLE CODES: THE INSTALLATION OF SOLAR ARRAYS AND PV POWER SYSTEMS SHALL BE IN ACCORDANCE WITH THE MOST RECENT NATIONAL ELECTRICAL CODE AS WELL AS ANY BUILDING STANDARDS, AS AMENDED BY DARTMOUTH, TOWN OF JURISDICTIONAL INFORMATION: ADDRESS: 400 SLOCUM RD. RM 210 DARTMOUTH, MA 02747 PHONE NUMBER: (508) 910-1820 NOTES TO INSTALLER ARRAY TO BOS (DC): CONDUIT RUN THROUGH ATTIC TO`'NORTH EXTERIOR WALL, THEN PENETRATE OUT AND RUN DOWIN TO �� �� INVERTER. FROM OVERTTER T C' tiG / LOACUS / AC DISCONNECT T O SUPPLY SIDE C©NNEC INVERTER AT METER. ELAINE A. cP MONITORING RUN: SYSTEM WILL USE CELLULAR MONITCORING, NO �j C:)h UhN� HARD -WIRED RUN NECESSARY --4 CiVIL �' ADDITIONAL NOTES: CONFIRM ALL CONDUIT RUNS W/ No.49029 HOMEOWNER CUSTOMER NAME: John Ferreira / Ferreira - 855602 5 Radcliff Ln North Dartmouth, MA 02747 AC / DC kW STC: 5.19 kW / 6 kV(/ REFER TO PLAN NOTES DESIGNED BY: REV # PAGE PV1.0 -SECTION N1-N11 I MS 0 r v O.O SUNGEVITY INC. 66=RANKLIN ST SUITE 310OAKLAND, CA 94607 By: Michael Solis Date:3I3112014 Location: C:1Customere (Loc QlFerreim-85560ZDesign Sheet Size: 11xi7 THESE DRAWINGS, SPECIFICATIONS, AND DESIGNS ARE THE PROPERTY OF SUNGEVITY INC. NO PART SHALL BE COPIED OR USED FOR OR WITH ANY OTHER WORK OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT OUR WRITTEN) CONSENT A B C L V .J GENERAL NOTES: GENERAL NOTES: N1. DRAWINGS ARE DIAGRAMMATIC ONLY. THE LOCATION AND ROUTING OF RACEWAYS SHALL BE DETERMINED BY THE CONTRACTOR UNLESS OTHERWISE NOTED OR STANDARDIZED. N2. ALL EQUATIONS ACCOUNT FOR WORST CASE CONDITIONS. N3. IF A DISCREPANCY IN QUANTITY OR SIZE OF CONDUIT, WIRE, EQUIPMENT DEVICES, OVERCURRENT PROTECTION, GROUNDING SYSTEMS, ETC. (ALL EQUIPMENT AND MATERIALS) THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIALS AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS IN THE SPECIFICATIONS OR NOTED ON THE PLANS TO ENSURE COMPLETE COMPLIANCE WITH ALL CODES AND TO ENSURE THE LONGEVITY AND SAFETY OF THE OPERABLE SYSTEM. N4. ALL OUTDOOR EQUIPMENT SHALL BE MIN. NEMA 3R RATED. N5. METAL CONDUIT AND ENCLOSURES SHALL BE USED WHERE PV SOURCE OR OUTPUT CIRCUITS ARE RUN INSIDE A BUILDING. N6. MODULES SHALL NOT BE PLACED OVER ANY PLUMBING VENTS AND AT LEAST 6" ABOVE FLUSH VENTS. N7. THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH ANY AND ALL REQUIREMENTS GIVEN BY UTILITY COMPANIES. N8. FOR ADDITIONAL EQUIPMENT SPECIFICATIONS, SEE PROVIDED CUT SHEETS. N9. ALL LABELS AND MARKINGS SHALL BE ATTACHED ACCORDING TO REQUIREMENTS BY NEC AND THE LOCAL AHJ. THE AHJ MAY HAVE SPECIAL LABEL REQUIREMENTS BEYOND THE SCOPE OF THIS DOCUMENT. THIS MAY ENCOMPASS LANGUAGE INCLUDING, BUT NOT LIMITED TO, THAT FOUND IN NEC ARTICLES 690.5 (C), 690.14 (C)(2), 690.17, 690.53,690.35(F), 690.54, 690,64(B)(7) and 705.10 N10. INSTALLER TO FOLLOW ALL LOCAL JURISDICTION GUIDELINES. N11. ALL NEC REFERENCES SHALL BE DIRECTLY INTERCHANGEABLE WITH CEC REFERENCES. STRUCTURAL NOTES: S1. MOUNTS ARE DIAGRAMMATIC AND EXACT LOCATION MAY CHANGE, BUT SHALL BE ACCURATELY SPACED. S2. MOUNTS SHALL BE STAGGERED WHEN NECESSARY TO EVENLY DISTRIBUTE LOAD AMONGST RAFTERS. S3. DO NOT SPLICE RAILS IN MIDDLE 50% OF SPAN BETWEEN TWO MOUNTS. ELECTRICAL NOTES: E1. ALL EQUIPMENT IS LISTED FOR USE. E2. MAXIMUM VOLTAGE DOES NOT EXCEED 600VDC. E3. ANY EQUIPMENT OR ELECTRICAL MATERIALS USED FOR THIS INSTALLATION SHALL BE NEW AND LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY. E4. AN INVERTER IN AN INTERACTIVE SOLAR PV SYSTEM SHALL AUTOMATICALLY DE -ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED. E5. ALL PV ARRAYS SHALL BE EQUIPPED WITH DC GROUND FAULT PROTECTION. E6. ANY AC COMPONENT SHALL MEET OR EXCEED THE AVAILABLE FAULT CURRENT CALCULATED AT THAT COMPONENT. E7. ALL MODULES AND ANY RELATED ROOF MOUNTED METALLIC EQUIPMENT SHALL BE PROPERLY GROUNDED. E8. DC EQUIPMENT SHALL BE 60OVDC RATED MINIMUM. E9. MARKINGS SHALL BE PROVIDED TO INDICATE THAT ALL CONTACTS OF THE DISCONNECT EQUIPMENT MIGHT BE ENERGIZED. E10. CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OR JUNCTION BOXES/COMBINER BOXES PER APPROPRIATE JURISDICTIONAL REQUIREMENTS. E11. FOR ANY UNGROUNDED PV SYSTEM, A LABEL READING: "WARNING - ELECTRICAL SHOCK HAZARD, THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED." SHALL BE PLACED AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE. E12. INVERTER(S) SHALL CONTAIN A GROUND FAULT DETECTION AND INTERRUPTION DEVICE. E13. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS. E14. THE POINT OF CONNECTION COMPLIES WITH APPLICABLE CEC/NEC. EIS. BACKFED SOLAR BREAKER(S) SHALL BE INSTALLED AT THE OPPOSITE END OF THE CIRCUIT OR FURTHEST AWAY FROM THE MAIN BREAKER. E16. ALL WIRE, VOLTAGES, AMPERAGES AND EQUIPMENT IS SIZED ACCORDING TO TEMPERATURE DERATING AND LOCATION. E17. ONLY COPPER (CU) CONDUCTORS SHALL BE USED. CONDUCTORS SHALL BE; STRANDED OR SOLID WITH PROPERLY RATED CONNECTORS. E18. DISCONNECT SHALL BE WIRED SO NO BLADES ARE ENERGIZED E19. ALL MODULES AND RACKING SHALL BE GROUNDED VIA IRON RIDGE RAIL INTEGRATED GROUNDING (PLEASE SEE DATA SHEET) OR WITH TIN PLATED DIRECT BURIAL RATED LAY IN LUGS USING STAINLESS STEEL HARDWARE, STAR WASHERtS, AND THREAD FORMING BOLTS OR WEEBS. E20. ALL EQUIPMENT SHALL BE GROUNDED, INCLUDING BONDING JUMPERS WHERE NECESSARY ACROSS RAIL SPLICE PLATES TO BOND INDIVIDUAL PIECES C7F RAIL.. JURISDICTION SPECIFIC NOTES: jH OF c �4 ELAINE A. o 14UANG CIVIL No. 49029 �!aNA�1 O TE�� LA N UUNUtv"Y ING.= rtWNKLINSI SUI I G31UrJAKLAND,UAU4cUI By:micnaeIsolle Uate7/312014 Location: CSCOatomem(LocaQ%Ferreim-855602\Deeign Sheet Size:11x17 THESE DRAWINGS,SPECIFICATIONS, AND DESIGNS ARE THE PROPERTY OF SUNGEVITY INC. NO PART SHALL BE COPIED OR USED FOR OR WITH ANY OTHER WORK OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT OUR WRrTTFN CONSENT I l� ARRAY LAYOUT 1 AZIMUTH: 162e TN SCALE: 3/16" = T-0" -9L 2 I MOUNTING DETAIL 2 SCALE : 1 1/2" = 1'-0" MODUL (24) ET SC MODULE MODULE REFER TO ARRAY SPECS FOR ROOF PITCH MODULE � SOLAR MODULE IRONRIDGE XRS RAIL IRONRIDGE 6105-T5 ALUMINUM L-F001 QUICKMOUNT SHINGLE FLASHINC AND LOW PROFILE MOUNT COMPOSITE SHINGLE 1/2" ROOF DECKING (1)18ex5"S.S. LAG BOLT MIN. 2 4" RAFTER EMBEDMENT 2x8 RAFTER HKE KA I ED CAULK 10 6E APPLIED AT PENETRATIONS MI: m IP 1'7, to10'-9" — --�1011'-2" 1010'-9"e. 1'-3" LO I..... ..r ...1 I I I I I I I I I I I I I......t.......1.......t... I� I I.: I I I I I I I I I� I I I I - - -- -- -1 I:I....... ...... I ....... I ... ... I....... I ....... ....... I ....... I.....L........... ;..............L.....L......L.... I I I I I I � try6A 471 I 4--';Tl-4 I U H - �- - - UANG cP m 1 � f I i � i i I I i s� � P, C61e1L 49029 1 ........................... ........ �..... ............... �....... ........................... �....... 1.......1..... .... ...I ..............I .......I I I I I I I I I I I I 1 1 1, �A L ENG`� -1 -- --1 - - -� I C CUSTOMER NAME: ROOF 1 John Ferreira / Ferreira - 855602 .m r rnu.. oc —1— s i sw i a iu Urn —, Un ensur ey: mi—ei sane U81e:4/evto1e Locamn: caceetOMM (LOC81)Tertetre .8556u\Design Sheet Size: 11.17 THESE DRAWINGS, SPECIFICATIONS, AND DESIGNS ARE THE PROPERTY OF SUNGEVITY INC. NO PART SHALL BE COPIED OR USED FOR OR WITH ANY OTHER WORK OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT OUR WMITTEN CONSENT