Loading...
BP-86766SCOPE OF WORK • SYSTEM SIZE: 969OW DC, 816OW AC • MODULES: (34) REC SOLAR: REC285TP2 BLK • INVERTER(S): (1) NINGBO GINLONG TECHNOLOGIES: SOLIS-1P9K-4G-US • RACKING: SNAPNRACK SERIES 100 UL; FLASHED L FOOT. SEE PEN D01. • (1) GINLONG SOLIS RSDAG 1:1 RAPID SHUTDOWN • (1) GINLONG SOLIS RSD-1G 2:2 RAPID SHUTDOWN VICINITY MAP GENERAL NOTES • ALL WORK SHALL COMPLY WITH 2O17 NEC, 2009 IBC, MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O17 NEC. • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2O17 NEC. • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 9.66 AMPS MODULE SHORT CIRCUIT CURRENT. • 15.09 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a) & 690.8 (b)]. LEGEND AND ABBREVIATIONS SE SERVICE ENTRANCE MP MAIN PANEL SP SUB -PANEL F01 PV LOAD CENTER IS-1 SUNRUN METER PM DEDICATED PV METER INVERTER(S) WITH INV INTEGRATED DC DISCONNECT AND AFCI AC AC DISCONNECT(S) DC DC DISCONNECT(S) [Ed CB COMBINER BOX F- -1 INTERIOR EQUIPMENT LE a SHOWN AS DASHED TABLE OF CONTENT-S PAGE # DESCRIPTIr3N SOLAR MODULES PV-1.0 COVER SHE -ET RAIL PV-2.0 SITE PLP& PV-3.0 LAYOUT — PV-4.0 ELECTRICAL STANDOFFS & PV-5.0 SIGNAGI< FOOTINGS CHIMNEY Q ATTIC VENT Q FLUSH ATTIC VENT" O PVC PIPE VENT__-Z' ® METAL PIPE VENT ® T-VENT SATELLITE DISH FoFIRE SETBACKS El HARDSCAPE — PL— PROPERTY LINE SCALE: NTS A AMPERE AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT (E) EXISTING EXT EXTERIOR FRM FRAMING INT INTERIOR LBW LOAD BEARING WALL MAG MAGNETIC MSP MAIN SERVICE PANEL (N) NEW NTS NOT TO SCALE OC ON CENTER PRE-FAB PRE -FABRICATED PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC TL TYP TRANSFORMERLESS TYPICAL V VOLTS W WATTS REV NAME DATE COMMENTS A #180120 734 FOREST STREET #400, MARLBOROUGH, fMA 01752 PHONE 888,657.6527 FAX 805.528.9701 CUSTOMER RESIDENCE:: ANN SILVA 9 RADCLIFF LN DARTMC)UTH MA USA 02747 TEL. (508) 992-0167 APN #:0033B:0054tL:0003 PROJECT NUMBER: 221 R-009SILV DESIGNER: 3031.942.2528 ANDREW HOFFMAN DRAFTER: ANDREW HOFFMAN SHEET COVER SHEET REV: A 9/2)8/2017 PAGE PV-1.0 SITE PLAN - SCALE = 1/32" = 1'-0" ® Pt (N) ARRAY AR-01 (N) ARRAY AR-02 Pt (E) RESIDENCE r (N) (1) GINLONG 1:1 RAPID pt SHUTDOWN DISCONNECT Pc (N) (1) GINLONG 2:2 RAPID SHUTDOWN DISCONNECT INV C j M� SM AC SE ' '• o . • , (E) DETACHED STRUCTURE -n v r r Z v r A� a� r A� v r A� V r A� ROOF TYPE AR-01 COMP SHINGLE AR-02 COMP SHINGLE D1 - AR-01 - SCALE: 1/8" = V-0" PITCH: 45' AZIM: 266' D2 - AR-02 - SCALE: 3116" = 1'-0" PITCH: 25' AZIM: 86' ATTACHMENT ROOF HEIGHT ROOF FRAME EXPOSURE MATERIAL FLASHED L FOOT. SEE PEN D01. TWO STORY ATTIC WOOD FLASHED L FOOT. SEE PEN D01. TWO STORY ATTIC WOOD c 1, 1 FRAME TYPE FRAME MAX FRAME OC ROOF EDGE MAX RAIL MAX RAIL DESIGN CRITERIA SIZE SPAN SPACING ZONE SPAN OVERHANG MODULES: RAFTER 2 X 10 10' - 0" 16" N/A 4'-0" V-4" REC SOLAR: REC285TP2 [BLK RAFTER 2 X 10 16- 2" 16" N/A 4'-0" V-4" MODULE DIMS: 65.94" x 39.25" x 1.49" (38rmm) MODULE CLAMPS: Portrait: 8.2" - 16.4" Landscape: 4.9" - 9.8" MAX DISTRIBUTED LOALI: 3 PSF SNOW LOAD: 30 PSF WIND SPEED: 110 MPH 3-SEC GUST. LAG SCREWS: 5/16"x3.5": 2.5" MIN EMBEPDMENT NOTE: INSTALLERS TO VERIFY [RAFTER SIZE, SPACING AND SLOPPED SPANS, AND NOTIFY E.0)'R. OF ANY DISCREPANCIES BEFORE PROCEEDING. PENETRATION SPACING:: FULLY STAGGERED #180120 734 FOREST STREET #400, MARLBOROUGHJ, MA 01752 PHONE 888.857.8527 FAX 805.528.9701 CUSTOMER RESIDENCE: ANN SILVA 9 RADCLIFF LN DARTM(OUTH MA USA 02747 TEL. (508) 992-0167 APN #: 0033B:005UL:0003 PROJECT NUMBER: 221R-009SILV DESIGNER: 30)3.942.2528 ANDREW HOFFMAN DRAFTER: ANDREW HOFFMAN SHEET LAYOUT REV: A 9//28/2017 PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE OMETER #: M EVERSOURCE (MA) 2391964 UTILITY GRID SUPPLY SIDE TAP 5 1 EXISTING 200A (N) LOCKABLE ( MAIN BREAKER BLADE TYPE FUSED J AC DISCONNECT iN, EXISTING 200A MAIN FACILITY -' '- PANEL LOADS FACILE- 50A FUSE _ GROUND SQUARE D D222NRB 3R, 60A 120/240VAC (1) RSD 1:1 RAPID NINGBO GINLONG SHUT DOWN DEVICE, PV MODULES ( N) LOCKABLE (N) SUN RUN TECHNOLOGIES: NEMA 4X, 600v REC SOLAR: REC285TP2 BLK BLADE TYPE CENTRON 4G SOLIS-IP9K-4G-US 1A / (12) MODULES AC DISCONNECT METER 9000 WATT INVERTER JUNCTION BOX +(�jff (1) STRING OF (12) MODULES OR EQUIVALENT ic 4 4 4 2 0 -0 M PV MODULES IB ffj REC SOLAR: REC285TP2 BLK SQUARE D DU222RB 240V METER SOCKET 125A CONTINUOUS & LOAD RATED DC DISCONNECT WITH AFCI, RAPID SHUTDOWN r [- + _� (22) MODULES (2) STRINGS OF (11) MODULES 3R, 60A,2P 240V METER COMPLIANT 120/240VAC 200A, FORM 2S (1) RSD 2:2 RAPID SHUT DOWN DEVICE, NEMA 4X, 600V, WITHIN 1' OF ARRAY CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1A NONE (2) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER 1 B NONE (4) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER 2 NONE (6) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER (4) 18 AWG SIGNAL CIRCUIT WITHIN TC-ER 3 3/4" EMT OR EQUIV. (6) 10 AWG THHN/THWN-2 NONE (1) 8 AWG THHN/THWN-2 (2) 14 AWG THHN/THWN-2 SIGNAL CIRCUIT 4 3/4" EMT OR EQUIV. (2) 6 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 5 3/4" EMT OR EQUIV. (2) 6 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 MODULE CHARACTERISTICS REC SOLAR: REC285TP2 BLK: 285 W OPEN CIRCUIT VOLTAGE: 38.6 V MAX POWER VOLTAGE: 31.9 V SHORT CIRCUIT CURRENT: 9.66 A SYSTEM CHARACTERISTICS -INVERTER 1 SYSTEM SIZE: 9690 W SYSTEM OPEN CIRCUIT VOLTAGE: 522 V SYSTEM OPERATING VOLTAGE: 383 V MAX ALLOWABLE DC VOLTAGE: 600 V SYSTEM OPERATING CURRENT: 26.85 A SYSTEM SHORT CIRCUIT CURRENT: 36.23 A NOTES TO INSTALLER: 1. 463 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. 2. CONNECT SYSTEM VIA INSULATION PIERCING ON SUPPLY SIDE OF MAIN BREAKER IN MAIN PANEL ENCLOSURE. CONDUCTORS ARE FIELD INSTALLED. 3. CONNECT THE RAPID SHUTDOWN SIGNAL CIRCUIT CONNECTORS PER MANUFACTURER SPECIFICATION. 4. SPLICE THE 14 AWG THHN/THWN-2 CONDUCTORS FOR RAPID SHUTDOWN SIGNAL CIRCUITS INTO 18 AWG CONDUCTORS WITHIN TC-ER CABLE AT THE JUNCTION BOX. ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2017: 692.17 POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): NEC 2017: 705.12(13)(2)(3)(b) DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM . I ARFI I OrATION- UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): CEC 2016: 705.12(D)(3), NEC 2017: 705.12(B)(3), NEC 2014: 705.12(D)(3), NEC 2011: 705.12(D)(4) THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR. LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): CEC 2016: 705.12(D)(2)(3)(c), NEC 2017: 705.12(D)(2)(3)(c), NEC 2014: 705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4) IWYAO ® OU :r LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): CEC 2016: 690.31(G)(3), 690.31(G)(4), NEC 2017: 690.31(G)(3), 690.31(G)(4), NEC 2014: 690.31(G)(3), 690.31(G)(4), NEC 2011: 690.31(E)(3), 690.31(E)(4), IFC 2012: 605.11.1.4 ' 10JDD�` 9111*1' U�� s j wjo n LABEL LOCATION: ON OR NO MORE THAN 1 M (3 FT) FROM THE SWITCH. PER CODE(S): NEC 2017: 690.56(C)(3) TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN • w CONDUCTORS OUTSIDE _ THE ARRAY. CONDUCTORS WITHIN ARRAY REMAIN ENERGIZED IN SUNLIGHT. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): NEC 2017: 690.56(C)(1)(b) I;ja101 •I'M940Qftt_101116 lif]N Nttillr LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2016: 690.54, NEC 2017: 690.54, NEC 2014: 690.54, NEC 2011: 690.54 PHOTOVOLTAIC SYSTEM COMBINER PANEL DO NOT ADD LOADS LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): CEC 2016: 705.12(D)(2)(3)(c), NEC 2014: 705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4) NOTES AND SPECIFICATIONS: • SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC 2016 AND NEC 2014 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. • SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. • LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN, UNLESS PORTIONS OF LABELS OR MARKINGS ARE VARIABLE, OR THAT COULD BE SUBJECT TO CHANGES, SHALL BE PERMITTED TO BE HAND WRITTEN AND SHALL BE LEGIBLE. • LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. • SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. • DO NOT COVER EXISTING MANUFACTURER LABELS. INVERTER 1 $ J : t•] [•YNl •� IG1 lhl • • • • "4�1%!1rw�► r II "1J ► ' • ' �� •l• ►1 z6.ss +rr>G: • i� 1 1 1. ,..i • • i dci /. 383 I•�y r r i• i 522 1ll�►�1)1 1 •'a �' * r .•'J` s.7>As" 36.23 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): CEC 2016: 690.53, NEC 2014: 690.53, NEC 2011: 690.53 -j:�' 1117 i7ill Iff i. #180120 734 FOREST STREET #400, MARL` -BOROUGH, MA 01752 PHONE 888.657.6527 FAX 805.528.9701 CUSTOMER RESILIENCE: ANN SILVA 9 RADCLIFF LN DlgRTMOUTH MA USA 02747 TEL. (508) 992-0167 APN #: 0F033B:0054L:0003 PROJECT NUMBER: 221 R-009SILV DESIGNER: 303.942.2528 ANDREW HOFFMIAN DRAFTER: ANDREW HOFFMIAN SHEET SIGNAGE REV: A 9/28/2017 PAGE PV-5'..p