EP-872220 X 0 m m LL N Q 1CY,1 FOR CONSTRUCTION Notes: ` 1. All conduit to use water -tight expansion fittings. 2. All Rooftop conduit to be a minimum of 1" above the roof surface. 3. PV Connection into Load Center shall be positioned at the opposite end from the Utility Input feeder location.(Where applicable) 4. All equipment to be rated NEMA-3R unless otherwise noted. 5. Lowest expected ambient temperature based on ASHRAE min. mean extreme dry bulb temperature for ASHRAE location most similar to installation. 6. Highest continuous ambient temperature based on ASHRAE highest month 2% dry bulb temperature for ASHRAE location most similar to installation. 7. All conductors to be copper unless noted otherwise. 8. Conductor sizing shall limit Voltage drop to 2% DC & 1.5% AC (2% for Enphase Systems). WIRE SCHEDULE VVM S127NGr VOLTAGE DROP Tag city I Conductor Size & Type Ground Size &Type Conduit 90°C Derated Aaimeaip=4 (Allowable Amps x Temp Derate, x Fill Derate) 75°C Ampacity Length V. Drop A ..... 3 ................:.........................................................{.................................. ; #12 AWG ENGAGE CABLE _ #6 AWG BARE Cu FREE AIR 30A X 0.7" --:", 22.8U & i 25.00 A N/A ° � ................................. .............................. ........................ .. ... .................... ...;.. ......:.......°.... B6 #10 AWG THWN-2 #8 AWG THWN-2 1 PVC/EMT 40A X 0.76 X O..S _ 2"4i.32A 35.00 A 100 Ft 0.48% C .........................................................................:..................................... #8 AWG THWN-2 #8 AWG THWN-2 .............................. 1"PVC .......... _,... 5A X 5 0.96 X I - " ............................. 50.00 A 20 Ft 0.39% DC .. ......... '-- ......._.... AC ............... .. 1.42% 8.060 kW DC(STC) PV System: 26 Silfab SLA 310 M Modules with 26 Enphase Energy IQ6PLUS-72-2-US Micro -Inverters Branch of 11 - Arrav 1 Branch of 11 (s1&3 Branch of 4 - Array 2 Electrical Junction Box MAIN SERVICE PANEL INTERCONNECTION 120% Rule - 705.12(D)(2) Utility Feed + Solar Backfeeedd 200 A + 40 A = 241 A I Buss Rating x 120% 200 A x 120% = 240 A NOTE: The load center contains only generation circuits and no unused positions or loads. (N) Enphase IQ Combiner w/ IQ Envoy X-IQ-AM 1-240-B NEMA 3R Encl. IQ Envoy Ethernet 12ov R R 1 to go thru CT 5A r, North Wall Adjacent to Util SYSTEM LABELING SPECIFTCATIONSr Max. DC Voltage (-17 °C): 45.3 V � Max, Current: 12.41 A ...................................................................................._._....__-_.._.._..._»................................... DC Operating Voltage: 33.1 V Oper3ti� CIurr•ent: 9.38 A ........................................................ ................ ... ..........-. - - ---_ _-................................. AC Nominal Voltage: 240 V VaY- AC (Current: 30.4 A (N) AC Disconnect 60 A, 240 Vac 2-Pole, NEMA 3R ir- Ib ------------------ n EIRI',fl3R n I n I h (E) Overhead n Service Drop: I 240V:120V Split Phase II I u I II I 2nd HIS iJ 1st Floor E) 200 A E) 200 A �1NS1 DWI (E) MSP 2 _._._.._ N (E) MSP 1 200 A Rated 200 A Rated Square D a Square D QOC40U G ° °mo r� QOC40U GEC: Gn2und GEC Ground RCS ENERGY AMERICA'S ORIGINALI SOLAR COMPANY 420 Woodlanra Ave, Unit A Bloomfield; JET 06002 GRID --:TIED PHOTOVOLT.'AIC SYSTEM 8.060kW 0C @ STC KELLY, BARBR'1RA AND KEN 5 PURDLa1E LANE N DARTMOUT-H, MA 02747 Project # 110359943 DESIGNER: Lucas Wurphy REVIEWER: Ash Boxv/ersock VEIZ810N DATE. 2017-110-25 REMSIIONS # By Date Notes 2 3 4 5 Not to Scale ELECTRICAL DIAGRAM PV-E01