EP-70926ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, BLDG BUILDING A SIGN WILL BE PROVIDED WARNING OF THE CONC CONCRETE HAZARDS PER ART. 690.17. DC DIRECT CURRENT 2. EACH UNGROUNDED CONDUCTOR OF THE EGC EQUIPMENT GROUNDING CONDUCTOR MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY (E) EXISTING PHASE AND SYSTEM PER ART. 210.5. EMT ELECTRICAL METALLIC TUBING 3. A NATIONALLY —RECOGNIZED TESTING GALV GALVANIZED LABORATORY SHALL LIST ALL EQUIPMENT IN GEC GROUNDING ELECTRODE CONDUCTOR COMPLIANCE WITH ART. 110.3. GND GROUND 4. CIRCUITS OVER 250V TO GROUND SHALL HDG HOT DIPPEDGALVANIZED COMPLY WITH ART. 250.97, 250.92(B) I CURRENT 5. DC CONDUCTORS EITHER DO NOT ENTER Imp CURRENT AT MAX POWER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR Isc SHORT CIRCUIT CURRENT ENCLOSURES TO THE FIRST ACCESSIBLE DC kVA KILOVOLT AMPERE DISCONNECTING MEANS PER ART. 690.31(E). kW KILOWATT 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN LBW LOAD BEARING WALL RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY MIN MINIMUM UL LISTING. (N) NEW 7. MODULE FRAMES SHALL BE GROUNDED AT THE NTS NOT TO SCALE UL—LISTED LOCATION PROVIDED BY THE OC ON CENTER MANUFACTURER USING UL LISTED GROUNDING PL PROPERTY LINE HARDWARE. POI POINT OF INTERCONNECTION 8. MODULE FRAMES, RAIL, AND POSTS SHALL BE PV PHOTOVOLTAIC BONDED WITH EQUIPMENT GROUND CONDUCTORS AND SCH SCHEDULE GROUNDED AT THE MAIN ELECTRIC PANEL: SS STAINLESS STEEL 9. THE DC GROUNDING ELECTRODE CONDUCTOR STC STANDARD TESTING CONDITIONS SHALL BE SIZED ACCORDING TO ART. 250.166(B) & TYP TYPICAL 690.47. UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT VICINITY MAP INDEX 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN ;T4Q.. : u z , PV3 STRUCTURAL VIEWS �,�5 �. PV4 UPLIFT CALCULATIONS PV5 THREE LINE DIAGRAM LICENSE GENERAL NOTES r = t ,Cutsheets Attached s g f 1. THIS SYSTEM IS GRID—INTERTIED VIA AT°4 GEN #168572 :j — " x ELEC 20571A UL—LISTED POWER —CONDITIONING. INVERTER.,;: 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. SOLAR MOUNTING FRAMES ARE TO BE�k , x'�: GROUNDED. .� � -� _ � �,--�� ., �.� � �g 4. ALL WORK TO BE DONE TO THE 8TH EDITION ,.$° ` `"4y, u ' g=. MODULE GROUNDING METHOD: SLEEKMOUNT OF THE MA STATE BUILDING CODE. 3 a 5. ALL ELECTRICAL WORK SHALL COMPLY WITH rc AHJ. Dartmouth i- ..,` ems,„, x a� �� t REV BY DATE COMMENTS THE 2011 NATIONAL ELECTRIC CODE INCLUDING •, REVA NAME 8/16/2013 COMMENTS MASSACHUSETTS AMENDMENTS. `_ ^' ►� ;�"AN UTILITY: NSTAR Electric (Boston Edison)3 an IL �] PREMISE OWNER: DESCRIPTION: DESIGN: 1I� CONFIDENTIAL - THE INFORMATION USED HEREIN JOB NUMBER J B-0 2,7 3 / 5 0 0 CONTAINED SHALL E EXCEPT USED FOR THE CROTEAU, BRENDA L CROTEAU RESIDENCE Justin Martin '„`; warcity, BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MWNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 12 WHALERS WAY 7.105 KW PV Array bu PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES NORTH DARTMOUTH ORGANIZATION, EXCEPT IN CONNECTION WITH , 'MA 02747 24 St. Martin Drive, Building-,,2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (29) YINGLI # YL245P-29t) SHEET. REV: DAIS Marlborough, MA 017;52 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PACE NAME: PERIWSSION OF SOLARCITY INC. INVERTER: T: (650) 638-1028 F. (650)):638-1029 sOLAREDGE SE6000A—Us (508) 636-9925 COVER SHEET PV 1 - 8/16/2013 (888)—SOL—CITY (765-2489) wnrmsdarcitycom PITCH: 44 ARRAY' IPITCH:44 MP1 AZIMUTH:180 ARRAY AZfiIMUTH: 180 MATERIAL: Comp Shingle STORY: 2 Stories LEGEND Inv ,� Q (E) UTILITY METER & WARNING, LLABEL INVERTER W/ INTEGRATED CDC DISCO AC Ins &WARNING LABELS MP © DC DISCONNECT & WARNIN(^ LABELS I 1 ° ©AC DISCONNECT & WARNING LABELS 0 1 0 JUNCTION BOX a ,. y � I 12 Whalers Way i — DC COMBINER BOX & WARNIIING � I A . DISTRIBUTION PANEL & WARNING Lc LOAD CENTER & WARNING [LABELS ' 1 Front Of House O DEDICATED PV SYSTEM METIER I j ' CONDUIT RUN ON EXTERIOR, - CONDUIT RUN ON INTERIOR GATE/FENCE - INTERIOR EQUIPMENT t � , SITE PLAN N Scale: 1/8" = 1' W E i 01' 8' 16 i S CONFIDENTIAL THE INFORMATION HEREIN JOB NUMBER: J B—O 2 7 3 7 O O PREMISE OWNER DESCRIPTION: DESIGN: CROTEAU, BRENDA L "'"," CONTAINED SHALL NOT BE USED FOR THE ° CROTEAU RESIDENCE JUStll1 Martin BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �®/�� auiar• NOR SHALL IT BE DISCLOSED 1N WHOLE OR IN Comp Mount Type C 12 WHALERS WAY /.105 .KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENT'S ! o ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: NORTH DARTMOUTH, MA 02747 THE SALE AND USE OF THE RESPECTIVE (29) YINGLI # YL245P-291) 24 St. Moron Drire, sBuilding 2, Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DAIS Madborou 01752 PERMISSION OF SOLARCITY INC. INVERTER. T. (650) 638-1028 ' [eA(sso) 638-1029 SOLAREDGE SE6000A-US {508) ,636-9925 SITE' PLAN PV 2 8/16/2013 (888)-SOL-CITY(765-2489) www.solaroity.oam PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE 7CD I C\/CI IAIC COOT - (1i I nn A-nnki AAIn nnu I nu nr - ' • '• \'/ LV VnIIVIY, nIYU UI\ILL rILV 1 ZEP ARRAY SKIRT (6) HOLE. SIDE E VIEW E� /► / . OF M P i (4) 02) SEAL PILOT HOLE WITH n J.L C V 1 V V 1 POLYURETHANE SEALANT. NITS ZEP. COMP MOUNT C ZEP FLASHING C (3) (3) INSERT FLASHING. (E) COMP. SHINGLE (4) PLACE MOUNT. RAFTER: (E) 2x6 @ 16" O.C4. CEILING JOIST: (E) 2x10 @ 16" O.(C. RIDGE: (E) 2x6 RIDGE BORRD MAX SPAN: 9'-0" MAX STANDOFF DISTANCE: 64" 0.(C. (E) ROOF. DECKING (1) (2) (5)1 INSTALL LAG BOLT WITH 5/16" DIA LAG BOLT (5) SEALING WASHER. WITH SEALING WASHER LOWEST MODULE SUBSEQUENT MODULES (6) INSTALL LEVELING FOOT WITH (2-1/2" EMBED, MIN) BOLT & WASHERS. ` (E) RAFTER S I AIVDOFF J1 CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: J B-O O O PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED s1TaLL NOTBEUSED FOR THE OF ANYONE EXCEPT SOLARg1Y INC., CROTEAU, B�RENDA L CROTEAU RESIDENCE Justin MartinBENEFIT MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN TO OTHERS Comp Mount Type C7.105 12 WHALERS WAY KW PV Array T'�' OUTSIDE THE RECIPIENTSORGANIZATION, EXCEPT -IN CONNECTION WITH MODULES NORTH DARTMOUTH, MA '02747THE oPART SALE AND USE OF THE RESPECTIVE (29) YINGLI # YL245P-29b L Martin Drive, Building 2d, Unit 11 SOLARgTY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. INVERTER: SOLAREDGE SE6000A—US (CJ 0 4 ) 6 •J Z 6 — 9 9 2 5 PAGE NAME STRUCTURAL VIEWS SHEET: REV DATE Z PV J 8/ 16j 2013 Mariborough, MA 017552 T. (650) 638-1028 R.(650)' 1:638-1029 (888)—SOL—CITY (765-2489) wrrvn.sdarcity.com CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER: L J J B-0 n 7 G Q O PREMISE OMER: DESCRIPTION: CROTEAU, BRENDA L CROTEAU RESIDENCE DESIGN: Justin. Martin ®� — �,��; • BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR IT BE DISCLOSED IN WHOLE OR IN 12 WHALERS WAY 7.105 KW PV Array /'ul 1 MOUNTING SYSTEM: SHALL Comp Mount Type C 0 PART TO OTHERS OUTSIDE THE RECIPIENTS NORTH DARTMOUTH, MA 02747 MODULES: ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (29) YiNGLi # YL245P-29b 24 St Martin Drh", Building $ Unit 11 Madborouo?h, MA 01752 SHEET REV: DALE: SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME P\/ A 1 T.- (650) 638 10213 F. (650) 638-1029 INVrRTER: PERMISSION OF SOLARCITY INC. soLAREDGE SE6000A—US (508)- 636-9925 UPLIFT CALCULATIONS s/ s/2a 3 tow) -SQL -CITY (765-2469) www.solarcitycom GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS BOND (N) #8 GEC TO TWO (N) GROUND Panel Number: Murray Inv 1: DC Ungrounded INV 1 - (1) SOLAREDGE sE6o00A-US LABEL:- A [LICENSE - (29) YINGLI # YL245P-29b GN #168572 ODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:97 035 222 Tie-1n: Supply Side Connection Inverter; 60 OW, 24OV, 97.574 w%ZB; SEIOOO-ZB02-SLV-NA PV Module; 245W, 221.6W PTC, H4, 46mm, Black Frame, YGE-Z 60, ZEP Enabled EVEC 20571A INV 2 Voc: 37.8 Vpmax: 30.2 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 100A MAIN SERVICE PANEL ` (E) WIRING HOFFMAN ENCLOSURE CUTLER -HAMMER ISOLARGUARDI Inverter 1 Located Outside Disconnect I METER I CUTLER -HAMMER 1 4TT Disconnect 3 SOLAREDGE A D A 35A - 1 String(s))'Of 15 On. MP 1 ' ; B i C Dc- L1 N GEC I L------J - I----------------------------- ------- EGC---------- --- - - - - - � DC+ DC- DC- 1 String(!.,)Of 14 On MP 1 EGC -- ------ LO ------- - I-Ifqc- J N 240 V GFP/GFCI TO (E) D-PANEL - I TO 120/240V SINGLE PHASE UTILITY SERVICE I I I I I L-.-,--- ------ ---- Voc* = MAX VOC AT MIN TEMP OTT 2)Ground Rod; 5/8" x 8% Copper 1 - 2 ILSCO IPC 4 0- Q , ` (1)CUTLER-HAMMER DG222NR8 Disconnect; 60A, 24OVac, Fusible, NEMA 3R AC PV (29)SOLAREDGE # OP250-LV-AH4SM-2NA PowerBox; 50W, H4, DC to DC Converter, ETL Listed DC Insulation Piercing Connector; Main 4/0-4, Tap 6-14 C (,I ) CUTLER -HAMMER # DG222UR8 - (1) CUTLER- AMMER DGi00NB Ground%Neutral Kit; 60-100A, General but DG y ( ) -(29)SolarEdgge # SE-Zep-OP SolarEdge Zep adapter bracket; Grounding, fasteners Disconnect; 60A, 24OVac, Non -Fusible, NEMA 3R (1)CUTLER-HAMMER DG100N6 Ground/Neutral It; 60-100A, General Duty (DG) -(1)CUTI ER -HAMMER DS16FK Class R Fuse Kit - (2)FClass SHse Kit TR35R PV BACKFEED OCP Fuse; SC SUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE 6 35A, 25OV, Class RKS SolarGuard Monitoring System AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. D (1) H�dMANe# NEMA43R �j (1)AWG 16, THWN-2, Black (1) AWG 16, THWN=2, Red O 1)AWG #8, THWN-2, Black lol- (1)AWG #8, THWN-2, Red ® (2)AWG #10, PV WIRE, Black Voc* = 645.59WDC (1)AWG #10, Solid Bare Copper EGC Vmp = 350 WDC Isc = 15 ADC Imp= 10.36 ADC L-L (1)AWG is. THWN-2, White NEUTRAL Vmp =240 VAC Imp = 25 AAC L-L (1)AWG #10, THAN-2, White NEUTRAL VmP =240 VAC IMP = 25 AAC (1 Conduit Kit;. 3/4'. EMT - (1)AWG #6,_ Solid Bare, Copper. GEC; , , ,- (1)Conduit. Kit;..14" EMT.. _ . , ..... - (1) AWG #8,.1HWN-2, Green EGC/GEC,- (1) Conduit, Kit;. 3/4" EMT... , , , , , , , O . .. . .. . . ... . ..* ... , , . „ , , . (2 AWG #10, PV WIRE, Black Voc 602.55\CYDC (1)AWG #10, Solid Bare Copper EGC Vmp = 350 WDC . Isc .= .15.ADC Imp 9.67 ADC (1)Conduit Kit: 3/4' EMT ... _ .. , ; CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT OF ANYONE EXCEPT USED FOR THE PT SOLARCITY INC., BENEFIT NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: J B-O 3 5 O O PREMISE OWNER: DESCRIPTION: CROTEAU, BRENDA L CROTEAU RESIDENCE � 2 WHALERS WAY -7 q K V /' I O5 f\W P V Array NORTH DARTMOUTH, MA. 02747 PAGE NAME 508 636-9925 ) THREE LINE DIAGRAM DESIGN: Justin MartinMOUNTING k `® '* '�/f Sotarcity. MSYSTEM: SYSTEM: Comp Mount Type C MODULES: (29) YINGLI # YL245P-29t) 24 St. Martin Oriive, Building 2, Unit 11 Madborouz�h, MA 01752 T: (650) 638-102t8 F: (650) 638-1029 (B66)-SOL-CITY (7653-2489) www.solareity.com INVERTER: soLAREDGE sEsaooA-us SHEET. REV: DATE PV 5 8/16/2013 sol r w . ' . ,..i, D =0z ., jr_ s . ' All = our inverters are part of SolarEd e's innovative s yste over 97% efficiency and best -in -class reliability. Our fixed - designed to provide superior performance at a competitive voltage technology ensures the inver ter is always working at its price. The SolarEdge Inverter combines a sophisticated, optimal input voltage, regardless p g , of the e nu tuber of modules or I digital control technology and a one stage, ultra -efficient power environmental conditions. ons. - conversion architecture to achieve superior P Performance Tj TECHNICAL DATA _ - _ r , pk e rAl u '� € T IR ,91 ,91 i ° ,•'�**k'm ;T, ,,.__.fig aooi s7 The only inverters specially designed for distributed DC architecture Superior efficiency (97.5%)., Ili Small, lightweight and easy to install on provided bracket Ver 6ii Built-in module -level monitoring 12e25 r )Hatt atdY sf. IN Communication to internet via Ethernet or Wireless 'aO 01 Outdoor and indoor installation - g le Integral AC/DC Switch u SE lOOOA US SE3800A US SE5000A US SE6000A US SE7000A US y- Rated AC Power output P 3000 3800 5000 52000208v 6000@240V ' 5200@208V 6000@240V W 6000@277V 7000@277V Max. AC Power Output P 3000 3800 - 5000 5200@208V 6000@240V 5200@208V 6000@240V W -' 6000@277v 7000@277V AC Output Voltage Min: Nom.-Max. 183 - 208 - 229 / 211 - 240 - 264 183 - 208 - 229 / 211 •240-264 / 244- 277 294 - AC Frequency Min.-Nom.-Max. - - 59.3 - 60 - 60.5 Vac Max. Continuous Output Current @208V 14.5 18.5 24 Hz 1 25 25 Max. Continuous Output Current 9240V 12.5 16 21 A Max. Continuous. Output Current @277V - 121 25 25 q 22 1 25 GFDI - A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes - -Recommended Max. DC Power * (STC) 3750 4750 6250 7500.,' 8750 Transformer -less, Ungrounded W� Yes - Max. Input Voltage - 500 Nom. DC Input Voltage 325 @ 208V / 350 @ 240V / 400 @ 277V Vdc Max. Input Current - 10 12.5 16 18 18.5 Vdc Adc Reverse -Polarity Protection Yes Ground -Fault Isolation Detection 600kQ Sensitivity Maximum Inverter Efficiency 97.8 - 97:7" 98.3 98.3 98.3 % CEC Weighted Efficiency 97 5 97 @ 208V / -97.5@ 97.5@ 208V, 240V 97 @ 208V / 97.5@ 240V / 240V / 98 @ 277V 98 @ 277V % .Nighttime Power Consumption < 2.5 W Supported Communication Interfaces - " RS485, RS232, Ethernet,-Zigbee (optional)- "'- ° ' ° a . `-�, s <., , -•, Safety �. UL1741, IEC-62103(EN50178),IEC-62109 Grid Connection Standards Utility -Interactive, VDE 0126-1-1, AS-4777, RD-1663 , DK 5940,.IEEE1547 Emissions ,FCC part15 class B, IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12 RoHS Yes AC Output- 3/4" Conduit DC Input 3/4" Conduit ' - Dimensions (HXWXD) - 21 x 12.5 x 7 / 540x315x172 21 x 12.5 x 7.5 / 540 x 315 x 191 in/mm Dimensions with AC DC Switch HxWxD) :30.5 - - / ( 775x315x172 30... 5x12........... 5x7.5/775x315x.191 in/mm Weight '. 42 / 19 - 45 / 20.5 Ib / kg Weight with AC/DC Switch 48.5 / 22 " - 52 / 23.5 Ib / kg Cooling Natural Convection - Min. -Max. Operating Temperature Range -4 / -20 (CAN version -40 / -40) to +140 / +60 °F / •C Protection Rating - NEMA 3R * Higter'npu DC powermay be installed, analyze yearly AC omfmnance. § - - ;� - _ "The following Part NDmbers are 1-11 la (CAN PNs are el Bible forthe Ontario FIT and micmFlT): 208/240V,tun operatngtemp-4F/2OC SE3000ALS,SE3.OA-US,SE5000"S,SE6000XUS,SE70000. R 27N, min aperahng temP-4F/-20C: SE5000ALS. SE6000ALS, SE]OOOA-US - 208/24OV, min. operating temp AOF/ADC: 1E3000XUSCAN, SE3800AL Al, SEBDODA4IN, SE6000A1U5 AN 2]]V, min opeating Tom,-0 I:14DC: SE5000A­1Ji SE6000"U M, SE7000A-USCAN /' C `C - - USA Is Germany a Italy in France m Japan a China a Israel r y {� }}LQ }p { {� y architects a of energy- www.solaredge.com solar e a T l�ll.ClJ li £j - ® SolarEdg T h I g , Inc. 20042012 All aghle r 1—d SOLAREDGE the SolarEdge logo, ARCHITECTS OF ENERGY end OPTIMIZED BY SOLAREDGE other trademarks mentioned herein 11. trademarks of their respective owners. Date: 06/2012. V.03.S.b,,et to change wthoot nob- are trademarks or reglst..d hed.marks of architects of energy" SolarEdge Technologies, Inc. All solar, =a@ 3. em t r : r u: a n i r .=�` � "+ ��.'�-,�..f-•�, "� °t "�'•a`�' ' ,� •� �' X..,s ems- ,.t,�k y i t , } .��� � �� T'�1 , �r�,:y� � ,�r., s•t f sue, .��� , ,� , 2 � 4 A superior approach to maximizing the throughput of photovoltaic systems using module embedded electronics In Up to 25% increase in power output Superior efficiency (99.5%) - peak performance in both mismatched and unshaded conditions m Flexible system design for maximum space utilization Is Next generation maintenance with module level monitoring and smart alerts In Unprecedented installer and firefighter safety The most cost effective solution for residential, commercial and large field installations i CA v w� k k` HIGHLIGHTS * Module level MPPT; optimizes each module independently I® Lower installation costs with faster design, less wiring, DC ® Dynamically tracks the global maximum operating point for both disconnects and fuses modules and PV inverter !in Easy and flexible installation — use the same installation methods i * Module -level monitoring for automatic module and string level as exist today fault detection allowing easy maintenance a Allows parallel uneven :length strings and multi -faceted ■ Electric arc detection - reduces fire hazards installations ■ Unprecedented installer and firefighter safety mode - safe module Is Allows connection of different module types simplifying inventory voltage when inverter is disconnected or off considerations InConnection of one or more modules to each power ootimizer In Immediate installation feedback for quick commissioning TECHNICAL DATA OP250-LV OP300-MV/OP400-MV OP400 EV (Q4 2011) 1 Rated Input DC power 250 300 / 400 400 4W Absolute Maximum Input Voltage (Voc) 55 75 1125 Vdc MPPT Operating Range 5 - 55 5 - 75 60 - 125 Vdc Maximum Input Current 10 10 5.5 Adc Reverse -Polarity Protection Yes Maximum Efficiency 99.5 % European Weighted Efficiency gg,g % CEC Weighted Efficiency 98,7 % Inductive Lightning Protection 1 m / ft Overvoltage Category 11 Maximum Output Current 15 Adc Operating Output Voltage 5 - 60 Vdc Total Maximum String Voltage (Controlled by Inverter) - US and EU 1-ph 500 Vdc Total Maximum String Voltage (Controlled by Inverter) - EU 3-ph 950 Vdc MEMO Vdc Safety Output Voltage per Power Optimizer 1 :Mmm— Minimum Number of Power Optimizers per g (1-ph system) / 16 (3 ph system) String (1 or More Modules per power optimizer) Maximum Number of Power Optimizers per Module power dependent; typically 20 - 25 (1-ph system) String (1 or More Modules per power optimizer) 45 - 50 (3-ph system) Parallel Strings of Different Lengths or' Orientations Yes EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC-62103 (class II safety), UL1741 Material UL-94 (5-VA), UV Resistant RoHS Yes Dimensions (WxLxH) 120x13ox37 / 4.72x5.11x1.45 mm / in Weight 450/ 1.0 gr/ lb Output PV Wire 0.95 m / 3 ft length ; 6 mm2 ; MC4 Input Connector MC4 / Tyco / H+S / Amphenol —H4 Operating Temperature Range -40 - +65 / -40 - +150 °C / IF Protection Rating IP65 / NEMA 4 Relative Humidity 0 - 100 USA 900 Golden Gate Terrace, Suite E, Grass Valley CA 95945, USA Q. ���- Germany Bretonischer Ring 16, 85630 Grasbrunn (Munich); Germany solar" ®A a Japan B-9 Ariake Frontier Building, 3-7-26 Ariake, Koto-Ku, Tokyo 135-0063, Japan architects of energy - Israel 6 HeHarash St. P.O.Box 7349, Neve Neeman, Hod Hasharon 45240,Israel www.solaredge.com O SolarEdge Technologies, Inc. 2009-2011 . All rights reserved. SOLAREDGE, the SolarEdge logo, ARCHITECTS OF ENERGY and OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of pch' }pc'1'C of pn p pa, /TM _ SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 09/2011. Subject to change without notice. ®larii SI ®u�1tT"l Comp i ~ ° TM ®lr I i ®n CO Installation instructions The SolarCity SleekMount hardware solution • Utilizes Zep Solar hardware and UL 1703 listed is optimized to achieve superior strength and Zep Compatible modules p p �� y r Drill Pilot Hole of Proper Diameter for aesthetics while minimizing roof disruption and . Interlock and grounding devices in system UL Fastener Size Per NDS Section 1.1.3.2 labor. The elimination of visible rail ends and listed to UL2703 " ✓ Seal pilot hole with roofing sealant mounting clamps, combined with the addition of array trim and a lower profile all contribute • Interlock and Ground Zep ETL listed to UL 1703 hrf Insert Comp Mount flashing under upper to a more visually appealing system: SleekMount as "Grounding and Bonding System" . ,: layer of shingle utilizes Zep Compatible TM modules with • Ground Zep UL and ETL listed to UL 467 as - Place Comp Mount centered strengthened frames that attach directly to grounding device4=: H r upon flashing Zep Solar standoffs, effectively eliminating the need for rail and reducing the number of • Painted galvanized waterproof flashing _ Install lag pursuant to NDS Section 11.1.3 standoffs required. In addition, composrtion . Anodized components for corrosion resistance with sealing washer. shingles are not required to be cut for this system, allowing for minimal roof disturbance. • A licable for vent spanning functions pp 'w 8. Secure Leveling Foot to the Comp Mount Screw using machine Place module Components TMkn "#;u - I' � 5/16" Machine Screw �B Leveling Foot, Lag Screw r (rA` Camp Mount ° 1 r Comp Mount Flashing j x LISTEDO'kit bo n; January 2013 Z)olalcit;I January 2013 A �oMPate o ® i `�0"YL250P-29b W , YL245P-29b � pYL240R 29bYIN&C ' �LAR LLIES YL235P-29b YL230P-29b U.S. Soccer Powered by Yingli Solar RED Ideal for residential and commercial applications where cost savings, installation time, and aesthetics matter most. "7:iu m Lower balance -of -system costs with Zep w� ..Compatible'" frame. r - � Reduce on -roof labor costs by more than 25%. Leverage the built-in grounding system - ` a if it's mounted, it's grounded. II, Lower your parts count - eliminate rails, screws, : mounting clips, and grounding hardware. a s 0 Design and permit projects easily with access 3 to layout calculator and stamped drawings. E Lower installation costs with savings across equipment and labor.It � t Minimize roof penetrations while maintaining a� g e "• ti the system's structural integrity. ' Invest in an attractive'solar array that includes €, r a black frame, low mounting profile, and4 aesthetic array skirt. ¢ Increase energy output with flexible module layouts (portrait or landscape). It Trust in the reliability and theft -resistance of s the Zep Compatible`" system. Leading limited power warranty* ens ures T 91.2% of rated power for 10 years, and 80.7 Of rated power for 25 years. AC SOLUTION OPTION RIF� µ The YGE-Z Series is now available as 10 year limited product warranty. an Enphase Energized" AC Solution. 3 enptias r This solution delivers optimum - g In compliance with curwarranty terms and conditions. �s performance and integrated intelligence. The Enphase M215-Z Zep Compatible Microinverter is designed to conned directly into the Z Series module ® ptr - groove, eliminating the heed for tools or fasteners - all with one easy step. - UL 1703 and ULC 1703, CEC, FSEC, ISO 9001:2008, . ISO 14001:2004, BS OHSAS 18001:2007, SA8000 CO us - .--�- s Intelligent real-time LISTED .. g ir«o oVOL nc voouio '•,>r«:�`� „ monitoring at the system 440D and module level with --- �` Enlighten. �­!ISFPIV NO YINGLISOLAR.COM/US Yingli Americas 460 CELL SERIES ` Powered by YINGLI ELECTRICAL PERFORMANCE GENERAL CHARACTERISTICS Module type ',; YL250P-29b YENS -29b YL240P-29b�YL235P-29b YL230P-29b Dimensions(L/W/H) 64.96 in(1650 mm)/ 38.98 in(990 mm)/ Power output Pm W ! 250 245 240 235 230 1.81 in (46 ram) -power output tolences � -0/+5 -Weight 45.216i .__-_------ (20.5 kg) Module efficiency 11% ! 15.3 15.0 14.7 '. 14.4 14.1 -_--_ - Voltage at P. Vmrs, V 30.4 30.2 29.5 29.5 29.5 Current at P. i 1. A 8.24 811 814 797 zoo PACKAGING S-PECIFICATIO.NS ' Open -circuit volt V« �. V 38.4 37.8 37.5 '. 37.0 37.0 Number of modules per pallet 22 Short-circuit current 1. A _ 8.79 8.63 I, ' 8.65; 8.54 8.40 Number of pallets per 53 m b nerL , 36 STC: 1000N/mr inediance, 25°C cell temperature, AMI,5g spectrum according to EN 60904-3 - - - Average relative efficiency reduction of 5.0%at 200W/m= according to EN 60904-1 Packaging box dimensions (L/W/H) 67 in (1700 mm) / 45 in (1150 mm) / 47 in (1190 mm) a MEMO - - - e • _ ...•� - ° - _. _ I Box weight ". - 1076 Ibs (488 kg) output Pm W 181.1 Power o 177.9 1743 1707 167.0 ..._... __-___.-_ ...u.... _.___._- ................__-- Voltage at P V- V 27.6 27.2 26.6 26.6 26.6 Units: inch (mm) Current at P. Ia A 6.56 6.54 -- -- - - 6.56 6.42 6.29 Open -circuit ltgeV« V 35.4 34.5 34.2 33.8 33.8 38.98 (990 it I ent 712 - G99 -- 701 i�l 6.92 Shortareu�a At 681 36.85 (936 1.81 (46j g tmoduleo t on rem t NOCT ope pera pera urea 0W/m° inadiance, 20 C ambient temperature, I m/s wind speed 80 m - THERMAL CHARACTERISTICS Nominal operating cell temperature No[T ° C II�� 46 +/- 2 S f _ ---_- TempenmLir coeff cie t of P. A/°C -- ---- -0.45 -0.45 M Temperature coefficient of V... I7 %/°c -0.33 - Temperature coefficient of 1. 0.06 Grounding Wot 8 ID n o _ o Temperature coefficient of Vmvp pv,«r %/°C I -0.45 oi � O P ER AT I N G C O N D I T 1 O N 5 system 600vo M ntinq ales 4-0.2S6.0.315 (6.5x8) Max. series fuse rating 15A Limiting reverse current 15A Drainage holes C 'C Operating temperature range- -40 to 194°F (40 to 90°C) 315 PA) Max. static load, front (e.g., snow and wind) 50 psf (2400 Pa) u 3.94 (100) Max. static load, back (e.g., wind) 50 p f (2400 Pa) O.q7 (12) ``•� Hailstonimpact 1 in (25 mm) at 51 mph (23 m/s) EDP CONSTRUCTION MATERIALS Front cover (material/type/thickness) Low ion glass / tempered / 3.2 mm Glass may have anti -reflective coating Cell (qu t ty/ terial/type/dimensions/ 60 / poly I con / -1ticrystallin, ar a/N of6 b ) 156mmx156 /2433 m'/2or3 - E.-ps.kint (matena0 Ethylene vinyl acetate (EVA) Frame ( terial/color) A odaed al,min,m all y / black_ - ---- - ---- ---- --- --- - ----- Warning: Read the Installation and User Manual in its entirety Ai Junction box (protection degree) I'', >IP65 before handling, installing, and operating Yingli modules. Cable (type/length/gauge/outside diameter) PV Wire / 43.31 in (1100 mm) / 12 AWG / 0.244 in (6.2 mm) Plug connector Amphenol / H4 / IP68 Our Partners (manufacturer/type/protection degree) The specifications in this datasheet are not guaranteed and are subject to change without prior notice. This datasheet complies with EN 50380:2003 requirements. - Yingli Green Energy Americas, Inca info@yingliamericas.com Tel: +1 (888) 686-8820 YIN G 1 � �OL�R V YINGLISOLAR.COMMS NYSENGE . (YA, ©;Yingli Green Energy Holding Co. Ltd. YGEZ60CellSeries2Ol2 EN 201206-V01 U.S. Soccer Powered by Yingli Solar