Loading...
BP-92080 SOLAR PANEL PLANGENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS SCOPE OF WORK PAGEN DESCRIF`TION • SYSTEM SIZE: 9570WOC. IDOOOWAC • ALL WORK SHALL COMPLY WITH NEC 2017, IBC 2015, MUNICIPAL CODE, AND SOLAR MODULES PV-1C COVER v HEET . MODULES.(29) LG ELECTRONICS'. LG330HIC-AS ALL MANUFACTURERSLISTINGS AND INSTALLATION INZIRUCTIONS. SE SERVICE ENTRANCE . INVERTERS: • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017 PV-20 SITE PILgN PV-30 LAYSUT (1)SOLAREOGE TECHNOLOGIES: SE10000H-US WITH • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH HEC 2017. REVENUE GRADC-METERING • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY MP MAIN PANEL . RACKING: GROUNDED IN THE INVERTER. PV40 ELECTRICAL SNAPNRACK RF FLASHTRACK COMP. SEE DETAIL • MODULES CONFORM TO AND ARE LISTED UN DER UL I'103, SNRBMOUNT PV 50 SIGNAGE SO-00708 • INVERTER CONFORMS TO AND IS LISTED UNDER UT 111 1. SP SUB -PANEL SON MOUNT . RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II CHIMNEY • SNAPNRACK MODULES, ARE CLASS A FIRE RATED, LC PV LOAD CENTER • RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL ATTIC VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31 OS SM SUNRUN METER • ARRAY DC CONDUCTORS ARE SIZED FOR OERATEO CURRENT. 0 FLUSH ATTIC VENT . 10.45 AMPS MODULE SHORT CIRCUIT CURRENT. • 16.32 AMPS DEBATED SHORT CIRCUIT CURRENT [690.8 (a)Sfi908(b). PM DEDICATED PV METER FOR STRUCTURALONLY . PC INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 690.12(5)(2), o PVC PIPE VENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE INVERTER(S)WITH G METAL PIPE VENT LIMITED TO 80 VOLTS WITHIN 30 SECONDS OF A RAPID SHUTDOWN INITIATION. INV INTEGRATED DC ❑ DISCONNECT AND AFCI 0 T-VENT HOEMq� 1 nAC AC DISGONNECT(S) iAACHER SATELLITE DISH sTRUClLRA1L y sx 1 DC DISCONNECTS) FIRE SETBACKS ¢, "93gyp�E CB COMBINER BOX HARDSCAPE N r, INTERIOR EQWPMENT -PL PROPERTY LINE LJ SHOWN AS DASHED SCALE:NTS - sunr un A AMPERE AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION x180120 _ _ DC DIRECT CURRENT (E) EXISTING �,,.,,,o„ �Aa@no Ylti `Aal lNA, vZovaaG EXT EXTERIOR PRO FRAMING CUSTOMER RESIDENQ;E: NOR INT INTERIOR SAPTM'. ". LBW LOAD BEARING WALL NUNO CUNHA. SMITR M(Lt g MAG MAGNETIC 11 KYLE JACOB ROgfD, li ILI LISP MAIN SERVICE PANEL DARTMOUTH, MA, OKAY NEW E UPS NOT TOSCALE TELL (EOM w20459 ,�q aA11 KYIP A^Sb Pnd, OR ON CENTER APN A. DART A9o050000005Y00005 X PRE-FAB PRE -FABRICATED PROJECT NUMBER'. PAR POUNDS PER SQUARE FOOT 221A 011 CUNT PV PHOTOVOLTAIC '6 TL TRANSFORMERLESS DESIGNER: TYP TYPICAL CHRISTOPHER YER(GER V VOLTS SHEET W WATTS REV NAME DATE COMMENTS COVER SHEET REV'.A '4111A019 PAGE PV-1.0 ` i' SITE PUN - SCALE =118 V-4" ARRAY TRUE MAGI PVAREA PITCH AZIM AZIMI' (SOFT) ® AS01 W in' 1W, 35U3 AR-02 26° 177- 191' 1044 (E)RESIDENCE (N)ARRAY AR-02 (N)ARRAY AR-01 1-MT1 sunrun #180120 v 7. J CUSTOMER RESIDENCE NUNO CUNHA 11 KYLE JACOB ROAR, DARTMOUTH, MA, ON747 EL,(508)542 0450 APB#'. DART 00005O0000j05O00005 PROJECT NUMBERI NOFryB�, 221R-0flCUN1 - DESIGNER: KYLE JACOB ROAD ZACHEft SBUGiVPAL y CHRISTOPHER YERG`ER SHEET SITE PLAN REV ¢tl12019 PAGE PV-2.0 SE O PM INV ROOF TYPE MOUNTING DETAIL ROOF HEIGHT ROOF FRAME FRAME IYPE FRAME MM FRAME ON ROOFEDGE MAXPEN AR-% E%POSURE MATERIAL SIZE $PAN SPACING ZONE MAMOO. :Ex DESIGN C.IiIT" COMP SHINGLE Fusry ucu Come. SEe oe7aL So -Dome 25TORY VAULTED WOOD PREFABRICATED TRUSS 2X4 SPACING OVERHANG MODULES: AR-02 COMP SHINGLE rwsrviagcrc com>.5ee osTAasoamos 25TORY VAULTED WOOD PREFABRICATED TRUSS 8'-0" 24" 5�0 4-0 1'-q" LG GLECTRONICS. LG`330N1C-AS Di -AR-01- SCALE :1/8"= T 0" 2X0 e'�0" 2q" 5'-0" p'.0" y 4" MODULE DIMS: S PITCH:26° D2-AR-02-SCALE: 1/8"=1'0" 66.38"x40"x1.57'(401min) AZIM: 17F PITCH:26° MODULE CLAMPS: ALMaT/° PONFap: SO -157 MAX DISTRIBUTED LpAD:3 PAL 1 SNOW LOAD: 30 PSF +-5'10'— 9'10" WINDSPEED: 139 MPH 3-SEC GUSTL LAG SCREWS: 1 5/16'D4"'. 2.5" MIN EMB€DMENT NOTE: - 4 TYP INSTALLERS TO VERIFY RAFTER WHILED SPANSPANDNONG NO SJEOPED SPANS AND NOTIFY ANY DISCREPANCIEMIBEFORE PROCEEDING. 6' 9" — 2D-3 f-� t'-i V' 1' 10• 1 16'-3' —1t 1 — f PENETRATION G' 1' STAGGERED FULLYYACING R00 SPACING: Ski. ROWS} BETY0EENING: COLUMN SPAC COLUMNNSEEN CO 0 ]i' BETWEEN CO W ryjINS -I 15 � 16'-10" - 4'TYP - 1 22-]" —11. 1.— I � I�gyp�„p yp yryR se5'li I!Y k9 N 312, I 4— #180120 FHQLE8III� Ill H,I1111 I'll CUSTOMER RESIDENCE'. HUNG CUNHA 11 KYLE JACOB ROAD:, DARTMOUTH, MA, 0274V7 TEL(5508) 541 ADS 4: DART-0W05000000j AG0005 PROJECTNUMBER: 221 R-011 CLN1 HOFLNS,^ �`R DESIGNER: K. ZPauL _ gCHER CHRISTOPHER YERGE'R SHEET STRUCTURAL LAYOUT �0/ONPL REV_A 4PPoE/2010 SEE SITE PLAIN FOR NORTH ARROW PAGE PV-lI 12O124O VAC SINGLE PHASE SERVICE OMETER METER#: M HR0E (MA)'IS4O149 UTILITY EXISTING 2O0AEMAIN �� BREAKER1EXISTING 2O0AMAIN PANELITUu TV rcv... SQUARED DZ22NR5 3R, BOA 12O124OVAC 12O24OVA0 (N)MA SMART SOLAREOGE TECHNOLOGIES UTILITY ON 000OH-W WITH REVENUE REVENUE GRADE METERING METER 1O000WATT INVERTER 0PNCTION BOX PV MODULES 3 2 1 LG ELECTRONICS'. LG330Ni GAS (29) MODULES OPTIMIZERS WIRED IN'. (1) SERIES OF(14) OPTIMIZERS (1) SERIES OF(15) OPTIMIZERS 24OVMETERSOCKET LOAD RATED DC DISCONN ECT 1O0A CONTINUOUS WITH AFCL RAPID SHUTDOWN SOIAREDGE POWER OPTIMIZERS COMPLIANT P37O NOTES TO INSTALLER: 1. 15 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. GROUND 2, CONNECT SYSTEM VI INSULATION PIERCING ON SUPPLY SIDE OF MAIN BREAKER IN MAIN PANEL ENCLOSURE. CONDUCTORS ARE FIELD INSTALLED. CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL 1 NONE (4)10 AWG PV WIRE NONE (1) B AWG DARE CGPPER 2 31P' EMTOREQUIV. (4) 1OAWGTHHN?HWN-2 NONE (DO AWG THHNRHWN-2 3 314"EMTOREQUIV (2) 0 AWG THHNTHWN2: C)1OAWGTHHNrtHWN2 (1) B AWG THHNrtHWN2 4 3l4"EMT OR EQUIV. (2) 0 AWG THHN?HWN-2 (1) 6 AWG THHNRHWN-2 (1) B AWG THHNNHWN-2 MODULE CHARACTERISTICS P370 OPTIMIZER CHARACTERISTICS: LG ELECTRONICS: LG33ON1C-A5. 330W MIN INPUTVVOLTAGE. 8 VOC OPEN CIRCUIT VOLTAGE'. 40.9A MAX INPUT VOLTAGE: 5O VDC MAX POWER VOLTAGE. 337V MAX INPUT IRS, 11 ADD SHORT CIRCUIT CURRENT: 1O 45A MAX OUTPUT CURRENT'. 15 AOE SYSTEM CHARACTERISTICS- INVERTERI SYSTEM SIZES 9570 W SYSTEM OPEN CIRCUIT VOLTAGE: i5V SYSTEM OPERATING VOLTAGE: 400A MAX ALLOWABLE DC VOLTAGE: 480V SYSTEM OPERATING CURRENT: 2392A SYSTEM SHORT CIRCUIT CURRENT: 3DA ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN PER CODES) NEC 2017 6�217 OFTI z 3 POWERSOURCEOUTPUT CONNECTION 00 NOT RELOCATE THIS OVERCURRENT DEVICE UFFELLOCATION O BROADER (IF PPLIC BLEE w PERAGRES) NEC sliTG IXGGRY I \; L HR ""'PO \ DUAL POWER SUPPLY SOURCES UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM LABEL LOCATION' TIDY SERVICE METER AND MAIN RICE PANELPER . NEC20 4 512 DAR NEC x NI TSB1Q11S1leA ll 7G5AUDXB THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY >VERCURRENT DEVICE SHAL NOT EXCEED AMPACITY OF TLGLOCATIONSERVICE PANEL a)ICEMETER AND MAIN s PER ITS NEC 2014 i05MORY)GRI) NNBC 2011 >GN5 RCSX) ©V0 �("✓ � o©d OUP EACH TURN, ABOVE AND x CON CONTAINING DC CIRCUITS. BELOW orys) SEEA 2016ACC IISBN) CaIOR DC CONDOM EVERY R AB, NEC zmr. AGO S1 XCR) 9G.a1(GSQ, NEC 2014 690.51 G RO AGO 31 G)GU NEC 011 GG"UEI G, EXONUE)PY FCZOiz:BBsPUT . ©LABEL ULOCATIONON OR NO MORE THAN 1 n(A FR FROM THE GWITON PER OODEEIC NEC¢B17.B9 BUSER TURN RAPID SHUTDOWN SWITCH TO THE "OFF' POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION ON OR �NECTING MEANS TO SHOT THE BY SYSTEMS CONNECTED.ARE P ES) NEC 2017. GO 7=i;a ri PHOTOVOLTAIC S.uY.S�T. EI M COMBINER PANEL LATELLOCATION G S ECT PHOTOVOLTAICSYSTEM O F DO NOT ADD LOADS NECTION, OCATION BUTT COSYS) EECom,B UP FT NECSOm BAY RE NEC HGTOV APPLICABLE) CCOMBNERIIF e9B G9GB PERQOLIES) NEC 201n705 l2mMAMF) M iR IYUTSI S NEC 2011, GEMUC@1 NOTES AND SPECIFICATIONS G2UAND REQu REMENrS OF THE NLI A1TA TICLE TBL UNLESS SSHALL EC oNSTRUCTONS ARE REQUIRED BYSECTON 00. OR REQUESTED PRIDE LO VEL AHD, .SGNS AND ADEQUATELY WARN OF UPPORDS USING EFFECTIVE BOARDS COLORS E EQUIPMENT OR WIRING D SYMBOLS. • PANELS METHOD HALL 55 NOT BE HANDTLY WRITTEN. UN NOSHALL NOT BEHAND THAT COULD V SUBJECT 0ElA SMALL ELS OR GRANDER AGE LE BE PERMITTED TO BE HAND WRITTEN AND HALL BELEGIBLE • LABEL SHALL CCTiO CHANGES SMALL E OF CUPPC Ni OUSABILLITY TO WITHSTAND TH E ENVIRON M ENT INVULVLO .SIGNS AND LORETO ALL COMPLY WITH ANSI Z95 44011, PRODUCTBAFFTY SIGNS AND PANELS. UNL588 BE SPECIFIED. .DO NOT COVER EXISTING MANUFAC URER FREELS R5i'vA' tl(9� ;a i {U`N_'ti1 �- �Yn�1V77dJR11V�1 q�N'91'IP�I�k[B111Nd 9 01. RTENISJ, DOUIBOONNEOTIMI BE PER CODRSNECOnG05 6 �, NEC 2017 B9GW, NEC 2014