Loading...
EP-86894PV SYSTEM: 93.72 kW (DC) - 86.40 kW (AC) MODULES: (284) (NEW) HANSOL TD-AN3 330W MONO MODULES SUB -ARRAY DESIGN: SEE 3-LINE DIAGRAM INVERTER: (6) (NEW) SOLAR EDGE SE14.KUS INVERTERS ROOF: CORRUGATED METAL, (1:12 SLOPE) RACKING: ECOLIBRIUM ECOFOOT 2 BALLAST SYSTEM (STRUCTURAL AND BALLAST LAYOUT DESIGN BY OTHERS) MODULE TILT: TILT MOUNTED AT 100 DEG. AZIMUTH: 182° DEG. - (284) MODULES PHOTOVOLTAIC PROJECT INFORMATION: 93.72 kW (DC) - 86.4 kW (AC) PV UTILITY INTERACTIVE SYSTEM DARTMOUTH BUILDING SUPPLY 958 REED ROAD DARTMOUTH, MA 02747 PROJECT NUMBER: 4523-113 PROJECT SHEET: (EXISTING) COLD SEQUENCE METER DISCONNECT, 400A, 120/208V, 3� SHEET TITLE: (EXISTING) UTILITY METE[-R AND CT CABINET, 120/208V, 3� SITE PLAN AND ELECTRICAL LAYOUT (EXISTING) ELECTRICAL TROUGH (POINT OF INTER -CONNECTION VIA LINE SIDE TAP) (INSIDE ELEC. ROOM) (EXISTING) MAIN SERVICE: PANEL, 400A, 120/208V, 3�, 4W+GND (INSIDE ELEC. ROOM)M w (NEW) PV SYSTEM DEDICATED 400A, 120/20BY FUSED AC DISCONNECT SWITCH RACFPOI/VT ENERG? (VISIBLE, LOCKABLE, LABS„LED) (INSIDE ELEC. ROOM) �I SOLAR DEVELOPER: (NEW) PV SYSTEM DEDICATED 400A, 120/208V AC DISCONNECT SWITCH RACEPOINT ENERGY, LLC (VISIBLE, LOCKABLE, LABS LED) (SOUTH SIDE OF BLDN) 221c WEAVER STREET (NEW) PV SYSTEM DEDICATED 400A, 120/208V AC AGGREGATE PANEL FALL RIVER, MA 02720 (6) BACKFED PV BREAKER S (NORTH SIDE OF BLDN) (6) (NEW) SOLAR EDGE SE14.4KUS INVERTERS (INTEGRAL AC AND DC DIl CONNECTS) (NORTH SIDE OF BLDN) (6) (NEW) EMT CONDUIT RI.JN -------------------------------------------------- -- (RUN ACROSS ROOF, RATS: " 1.. -----_----------------------------------- ED 4 MIN. ABOVE GRADE, ALONG EQUIPMENT WALL) (6) (NEW) JUNCTION BOXErs SOLAR PV DESIGNER: ILLUSTRATES 4FT FIRE CLEAR(NEMA 3R, UL 1741 RATED]ANCE I ) RENEWABLE DESIGN SOLUTIONS 10945 ESTATE LANE, SUITE E-105 PER 2012 IFC DALLAS, TX 75238 (BUILDING AXIS <250FT) HX6 G I PHONE: 214.564.9535 WWW.RENEWABLEDESIGNSOLUTIONc•COM 4'-0" i I r I ELECTRICAL ENGINEER: .... - I O I JOE GIGANTIELLO PE (ELECTRICAL) L�.-- -- ---- ---- - - -------- - - ---- - I -- -- -- --- -- -- -- - -- -- - 1 I PHONE: 267.882.5393 r!- - EMAIL:JGIGANTIELLO @RDSSOLAR.CCi�A ------ =- --- - j I --- (- { -- -- - - - -- - - -- -- - - - - - - - - -- - - - -------- 16 118 L- - --- ' - - - - - - - - - - -� -- -1 I o 10!&3tP -------- ---------- I6 -- Grua iLO Mo.�92 -------- L--�`�S ., _ OOO _j r --� -- ---- - - --- - - - - 1 - - - - - - - - - - - - / 18 , -- - --- - - - - -- _. L I- ___ __------ ---- -- -1------------J 16-------- ------ L---------- -- ----- W 1 1 ----� -- 16 18 - ------=--------- DARTMOUTH i i _ _________ --- NOTE: NOTE: __._:- _ - ---- _ __ _ _ BUILDING - - - �-- I I FOR UTILITY SUBMITTAL - - _ _ _ SUPPLY L---- ------------- - -------------J I - PURPOSES ONLY. NOT FOR CONSTRUCTION OR - I i- BIDDING PURPOSES DESIGNED BY: M. LABARBA 41-0" DATE: 05 / 10 / 2017 n I i I I I A B C D E F I I I -------------------------------------- ----------------- N (0°) (315°) (45°) REVISED: N/A 1. N/A 2. 3. 4. 5. W E SCALE: 3/32" = T-0" (270°) (90-) (225') (35� S (180°) GENERAL NOTES: 1. EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH 2O17 NEC ARTICLE 690, MUNICIPAL REQUIREMENTS, AND UTILITY REQUIREMENTS 2. PV CONSTRUCTION DOCUMENTS ARE NOT TO BE USED UNTIL APPROVED BY THE AUTHORITY HAVING JURISDICTION AND THE SERVING UTILITY. 3. WORKING CLEARANCES AROUND THE EXISTING AND NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IS ACCORDANCE WITH NEC 110.26 4. ALL CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC 300.6 (C)(1), 310.8 (D). 5. MINIMUM 90° C MOISTURE RATED INSULATION WIRE IS REQUIRED ON ALL OUTDOOR WIRING. 6. CONDUCTORS ARE TO BE COPPER UNLESS OTHERWISE NOTED 7. ALL EQUIPMENT SHALL BE UL LISTED, NEMA 3R RATED, LABELED AND INSTALLED IN ACCORDANCE WITH MANUFACTURES INSTRUCTIONS. 8. EQUIPMENT GROUNDING CONDUCTOR SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690.43, NEC 690.45, NEC 690.46. 9. EQUIPMENT GROUNDING CONDUCTOR TO BE CONTINUOUS PER NEC 690A8. 10. GROUNDING ELECTRODE CONDUCTOR SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690.47 11. GROUNDING ELECTRODE CONDUCTOR SHALL BE CONTINUOUS PER NEC 250.64 (C). 12. ALL GROUNDING CONNECTIONS SHALL BE MADE WITH UL LISTED CONNECTORS. 13. GROUNDING CONNECTION TO MODULES SHALL BE SECURELY FASTENED WITH UL USTEt) STAINLESS STEEL LAY -IN LUGS OR EQUIVALENT MEANS. 14. WHERE GROUNDING CONNECTIONS ARE MADE TO GROUNDING ELECTRODE(S), ONLY CAD -WELD EXOTHERMIC CONNECTIONS SHALL BE USED. 15. FOR FLAT ARRAY INSTALLATIONS, PROVIDE THE NORTH EDGE OF ARRAYS 1/4' HIGHER T'O DISPLACE WATER. 16. NO MODIFICATIONS TO RACKING SHALL BE PERMITTED. MAINTAIN MANUFACTURES INSTALLATION PRACTICES. 17. WHEN POSSIBLE, INSTALL WIRING AND BOS EQUIPMENT IN A MANNER THAT MINIMIZES 5UNUGHT EXPOSURE. 18. ALL CONDUIT SYSTEMS EXPOSED TO TEMPERATURE DIFFERENTIALS SHALL BE INSTALLto WITH EXPANSION FITTINGS AND BONDING JUMPERS IN ACCORDANCE WITH NEC 300.7(B) ALWAYS LEAVE SUFFICIENT SLACK IN CONDUCTORS RUN FOR THERMAL EXPANSION AND CONTRACTION. 19. BI-DIRECTIONAL UTILITY METER TO BE INSTALLED IF REQUIRED. VERIFY METER SOCKET AND OTHER SPECIFICATIONS FOR COMPLIANCE WITH UTILITY. 20. ALL INVERTERS SHALL BE UL 1741 AND IEEE 1547 COMPLIANT AND INSPECTED BY LOCAL UTILITY PRIOR TO COMMISSIONING AND OPERATION. 21. INVERTERS SHALL BE PROTECTED FROM DIRECT SUNLIGHT EXPOSURE- 22. CIRCUIT BREAKER TO BE SUITABLE PER NEC 690.64 (B)(5) 23. THE UTILITY AC DISCONNECT SHALL BE LOCATED NO FURTHER THAN 5 FEET FROM THE NET METER. 24. THE UTILITY AC DISCONNECT SHALL BE LOCATED ADJACENT TO POINT OF INTERCONNECTION. 25. RE -TIGHTEN CURRENT -CARRYING CONNECTIONS, ENCLOSURE SUPPORT FRAMING AND PANELS TO MANUFACTURERS'S RECOMMENDATIONS. 26. TOTAL CURRENT HARMONICS SHALL BE LESS THAN 3016 AT INVERTER AC TERMINAL 27. ARRAY LAYOUT SHALL BE CONSISTENT WITH THE ORDERING (AND LABELING) OF SOURCE CIRCUITS IN THE ARRAY COMBINER BOXES. 28. ALL BURIED RACEWAYS SHALL BE BURIED 18' FROM TOP OF CONDUIT/CONDUCTOR TO GRADE 29. ALL WIRE SIZING SHALL BE IN ACCORDANCE WITH NEC 110.14 30. WHEN A BACKFED CIRCUIT BREAKER IS THE METHOD OF INTERCONNECTION, CIRCUTTBREAKER SHALL NOT READ 'LINE AND LOAD". 31. FIELD VERIFY ALL SPECIFICATIONS PRIOR TO INSTALLATION. IT IS THE RESPONSIBILITY CY: THE CONTRACTOR TO NOTIFY THE DESIGN ENGINEER OF ANY DISCREPANCIES BETWEEN T-i:-= PROVIDED DOCUMENT AND FIELD SPECIFICATIONS. 32. FIELD VERIFY EXACT REQUIREMENTS WITH UTILITY AND CLIENT, INCLUDING AVAILABLE FAULT CURRENT, PRIOR TO ORDERING EQUIPMENT. 33. THE INSTALLATION CONTRACTOR IS RESPONSIBLE FOR NOTIFICATION AND COORDINATION WITH ALL PROPERTY OWNERS, UTILITIES, AND APPROPRIATE DIG -ALERT AGENCIES. THE CONTRACTOR SHALL ALWAYS USE EXTREME CAUTION WHEN TRENCHING FOR INSTALLATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER AND APPROVED REPAIR OF ANY AND ALL DAMAGES CAUSED DURING THE INSTALLATION. 34. FIELD VERIFY CONDUIT RUN FROM COMBINER BOX TO INVERTER. IF DIFFERENT THAN ILLUSTRATED, COORDINATE AND NOTIFY DESIGN ENGINEER TO REVISE ACCORDINGLY. 35. ALL DC CONDUCTORS (FROM ARRAY TO INVERTER) SHALL BE UL 1518, UL 44, UL 854 LIS tED AND 1000V RATED (SEE SPEC SHEET). 36. ALL DC EQUIPMENT GROUNDING CONDUCTORS (FROM ARRAY TO INVERTER) SHALL BE 01- 2703 LISTED AND 1000V RATED (SEE SPEC SHEET) 37. PV MODULES, J-BOX / COMBINER BOX, AND INVERTERS SHALL BE LISTED FOR 1000V OPERATION (SEE SPEC SHEETS). LEGEND GROUNDING CONDUCTOR CIRCUIT CONDUCTOR LINE 1 TERMINAL L1 LINE 2 TERMINAL GROUND CIRCUIT BREAKER 6�"� DISCONNECT SWITCH o �o ^FU�S--E,, V v IRREVERSIBLE SPLICE e GROUND PV SYSTEM ELECTRICAL DATA: STC: 93.72 kW (DC) (284) HANSOL TD-AN3 33OW MONO MODULES (142) SOLAR EDGE P700 OPTIMIZERS (6) SOLAR EDGE SE14AKUS INVERTERS PV SUB -SYSTEMS (1) - (4) 16.50 kW (DC) (50) HANSOL TD-AN3 33OW MONO MODULES (1) SOURCE CIRCUIT OF (18) MODULES, (9) OPTIMIZERS (1) SOURCE CIRCUIT OF (16) MODULES, (8) OPTIMIZERS (1) SOURCE CIRCUIT OF (16) MODULES, (8) OPTIMIZERS PV SUB -SYSTEMS (5) 15.84 kW (DC) (48) HANSOL TD-AN3 330W MONO MODULES (1) SOURCE CIRCUIT OF (16) MODULES, (8) OPTIMIZERS (1) SOURCE CIRCUIT OF (16) MODULES, (8) OPTIMIZERS (1) SOURCE CIRCUIT OF (16) MODULES, (8) OPTIMIZERS PV SOURCE CIRCUIT PV SUB -SYSTEMS (6) 5.94 kW (STC) 11.88 kW (DC) (18) HANSOL TO-AN3 330W (36) HANSOL TD-AN3 33OW MONO MODULES MONO MODULES (1) SOURCE CIRCUIT OF (18) MODULES, (9) OPTIMIZERS (9) SOLAR EDGE P700 OPTIMIZERS (1) SOURCE CIRCUIT OF (18) MODULES, (9) OPTIMIZERS (2) MODULES IN SERIES PER OPTIMIZER SOURCE CIRCUIT: 1 SOLAR EDGE SE14.4KUS INVERTER 1201208VAC 4, 60HZ MPPT VOLTAGE RANGE: SEE OPTIMIZER DATA MAX OUTPUT CURRENT: 40.OA UL 1741, IEEE 1547 NOMINAL DC INPUT VOLTAGE: 35OVDC MAX INPUT VOLTAGE: 60OVDC MAX INPUT CURRENT: 38A CEC EFFICIENCY. 97% (INTEGRAL DC AND AC DISCONNECT) (NEGATIVELY GROUNDED DC SYSTEM) (EXISTING) ELECTRICAL (EXISTING) TROUGH (EXISTING) EXISTING CT CABINET POINT OF 112.50 kVA 400A AND INTER - UTILITY TRANSFORMER COLD SEQUEN(UTILITY METER CONNECTION) METER AC DICONFECT US--- � I � N N I MAIN SERVICE LINE SIDE PV CONNECTION VIA NSI POLARIS LUGS TO UTILITY ALLOWED PER NEC 240.21 (D), 705.12 ELECTRICAL (A)AND 230r82 (6)�, ^r DISTRIBUTION GRID (VERIFY 112.50 kVA MINIMUM XFMR SIZE) eeoe ee G TO-N BOND I I i EXISTING SYSTEM GROUND: • #"AWG • GROUND ROD • UNDERGROUND METAL WATER PIPE • CONCRETE ENCASED UFER 400V MAX. 15.0A MAX. PV SOURCE CIRCUIT 5.28 kW (STC) (16) HANSOL TD-AN3 330W MONO MODULES (8) SOLAR EDGE P700 OPTIMIZERS (2) MODULES IN SERIES PER OPTIMIZER SOURCE CIRCUIT: 400V MAX. 15.OA MAX. PV SOURCE CIRCUIT 5.28 k-%V (STC) (16) HANSOL TD-AN3 33OW MONO MODULES (8) SOLAR EDGE P700 OPTIMIZERS (2) MODULES IN SERIES PER OPTIMIZER SOURCE CIRCUIT: 40CV MAX. 15.OA MAX. 0� ¢ m Del 0 DC+ _ DC GFCI ® ® AFCI - - DC (NEW) - G IDC P V J-BG G NOX NEMA3R I RAPID SHUTDOWN I UL 1741 40OVDC DISCONNECT ® ® (6) #10 AWG TF.',v N-2 CU PER NEC 690.12 I (1) #10 AWG TFtWN-2 CU E.G.C. { 400 VDC 3/4" EMT CONL`iUIT T I (6) #10 AWG CU PV WIRE (RUN ACROSS (ROOF, RAISED 4" (1) #6 AWG CU SOLID E.G.C. MIN. ABOVE Gr-BADE) DC+ DC I AAr A mvr-� i O PV SOURCE CIRCUIT - - - - 5.94 kW (STC) DC+ DC+ DC+ DC+ _ (18) HANSOL TD-AN3 33OW MONO MODULES DC DC DC DC 0 0- (9) SOLAR EDGE P700 OP'TlP�IIZERS MODULES IN SERIES PER OF�TIM12ER GFCI { (2) ® ® EB { SOURCERCUIT�Cl AOOV ki.AX + 1F.OA WAX. 1 1 1 L DC �/ I PV SOURCE CIRCUIT r- { - ---------------L (NEW) - G __ I _ _ _ _ 5.94 kW (STC) DC+ DC+ DC+ DC+ - PV J-BOX G N L1 L (18) HANSOL TD-RN3 330W ___ ___ ___ ___ NEMA 3R I { MONO tIODULES 191 SOLAR EDGE P700 OPTMIZERS DC DC DC DC UL 1741 400VDC RAPID SHUTDOWN DISCONNECT I I i (2) MODULES IN SERIES PER OPTIMIZER SOURCE CIRCUIT: e OOV MAX. 1 4.OA MAX. 6) ® (4) #10 AWG TI-' WN-2 CU PER NEC 690.12 I { (1) #10 AWG Th:)WN-2 CU E.G.C. �! �! 400 VDC 3/4" EMT CONDiUIT T T (4) #10 AWG CU PV WIRE (RUN ACROSS [ROOF, RAISED 4" (1) #6 AWG CU SOLID E.G.C. MIN. ABOVE W-RADE) I I I l20f2O8VAC, 3t (10 FT RUN) I I (3) #6 AWG THWN-2 CU { I (1) #6 AWG THWN-2 CU (NEUTRAL) (1) #8 AWG THWN-2 CU E.G.C. / G.E.0 I (1)1" EMT CONDUIT (RUN ACROSS EQUIPMENT WALL) I I I 120/208VAC, 3t (10 FT RUN) I I (EXISTING) MAIN SWITCHBOARD (3) 350 KCMIL THWN-2 CU I { 400A W/ 400A MAIN, 120/208 WYE, 3t, 4W (1) 350 KCMIL THWN-2 CU (NEUT`�AL) ( { (1) #2 AWG THWN-2 CU E.G.C. / C'.E.0 ( I (1) 2.5" EMT CONDUIT { 3P-400A A (RUN ALONG EQUIPMENT WALL))013 I I C I { N N 120/208VAC, 3t (10 FT RUN) 120/20$VAC, 3� (100 FT RUN) (3) 350 KCMIL THWN-2 CU (3) 350 KCMIL THWN-2 CU G (1) 350 KCMIL THWN-2 CU (NEUTRAL) (1) 350 KCMIL THWN-2 CU (NEUT'LRA L) (0) E.G.C. / G.E.C. (1) #2 AWG THWN-2 CU E.G.C. / C;.E,C 3P-50A I { (1) 2.5" EMT CONDUIT (1) 2.5" EMT CONDUIT { - - - - - - (RUN ALONG EQUIPMENT WALL) (RUN ALONG EQUIPMENT WALL BAND { THROUGH ATTIC) EXISTING EXISTING EXISTING I I CUSTOMER CUSTOMER CUSTOMER 3P-s°A I I LOAD LOAD LOAD �{- LINE - LOADS � LINE - LOADS i N N Li 1�-- N F - ----- - - - - - - G - -- =-- JGT I (NEW) DEDICATED PV SYSTEM (NEW) DEDICATED PV, SYSTEM (NEW) DEDICATED PV SYSTEM { UTILITY AC DISCONNECT SWITCH UTILITY AC DISCONNr CT SWITCH AC AGGREGATE PANEL 3-POLE, 400A, 120/208VAC, NEMA 3R 3-POLE, 400A, 120/208'VAC, NEMA 3R 400A,120/208VAC, 3�, 4W, NEMA 3R, (3) 300A FUSES (FAST ACTING) (VISIBLE BLADE TYPE,, LOCKABLE, (1) 3P-300A MAIN BREAKER NEW SYSTEM GROUND: - (NEW G-TO-N BOND) LABELED, ACCESSIBL `E 2417) (6) 3P-50A PV CIRCUIT BREAKER - (SE 14AUS INVERTER) #2 AWG - (VISIBLE BLADE TYPE, LOCKABLE, (LOCATED OUTSIDE) (2) GROUND RODS LABELED, ACCESSIBLE 2417) (DO NOT ADD ADDITIONAL LOADS (SPACED 6FT APART) (WITHIN 10FT OF INTER -CONNECTION) TO THIS PANEL - ANCILLARY LOADS EXEMPT) (COOPER-BUSSMAN LIMITRON JJS 300A FAST ACTING FUSES, 60OV, CLASS T, 1 PER PHASE) PHOTOVOLTAIC PRVECT INFORMATION: 93.72 kW (DC) - 86.4 M (AC) PV UTILITY INTERACTIVE SYSTEM DARTMOUTH BUILDING SUPPLY 958 REED ROAD DARTMOUTH, MA 02y47 PROJECT NUMBER: 4523-113 PROJECT SHEET: & 2C SHEET TITLE: 1-LINE ELECTRICAL DIARAM RACIW>OINT ENERGY, SOLAR DEVELOPER: RACEPOINT ENERGY, L_LC 221 c WEAVER STEEE ti FALL RIVER, MA 0272C ( SOLAR PV DESIGNER. RENEWABLE DESIGN SOLUTIONS 10945 ESTATE LANE, QUITE E-105 DALLAS, TX 75238 PHONE: 214.564.9535 W W W.RENEWABLEDIGNSOLUTIONS.COM ELECTRICAL ENGINEER JOE GIGANTIELLO P� (ELECTRICAL) PHONE: 267.682.5393 EMAIL:JGIGANTIELLOa_RDSSOLAR.COM c a GIGPp 7 NOTE: FOR UTILIT\e SUBMITTAL PURPOSES ONLY. NOT FOR CONSTr-UCTION OR BIDDING PURPOSES DESIGNED BY: M. t- ABARBA DATE: 05 � 10 / 2017 REVISED: NIA 1. N/A 2. 3. 4. 5. SCALE: NIA