Loading...
BP-92148EFIU__ COPY TOWN OF DARTMOUTH ZONING REQUIRMEN-TS: GENERAL RESIDENCE B DISTRICT MINIMUM SETBACK TO STREET LINE = 60.00' MINIMUM SETBACK TO SIDE LINE = 20.00' MINIMUM SETBACK TO BACK LINE = 20.00' EXISTING HOUSE LOCATION BASED ON EXIS-TING EXISTING HOUSE LOCATION BASED ON EXISTING FOUNDATION AS -BUILT DATED APRIL 14, 1997 BY SITEC ENGINEERING FILED WITH THE TOWN ON APRIL 17, 1997. of SHANE M. SOUSA CIVIL Na 49821 ItME0, n 1 I t) 5 f ROOFING SHINGLES F 0 T[o I j Eo Eo I i� rn I I FRONT ELEVATION SCALE: 1/4"=1'—O" RIGHT ELEVATION SCALE: 1/4"=1'-0" GENERAL NOTES 1. CONSTRUCTION OF THE RESIDENCE SHALL BE IN ACCORDANCE MITH THE DESIGN CODES AND STANDARDS: •780 CMR 51.00 MASSACHUSETTS RESIDENTIAL CODE AMENDMENTS •ICC 2015 INTERNATIONAL RESIDENTIAL CODE •140 MPH EXPOSURE B GUIDE TO WOOD CONSTRUCTION IN HKCH WIND AREAS FOR ONE— AND TWO—FAMILY DWELLINGS 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND NOTIFY ARCHITTECT OF ANY DISCREPANCIES, AMBIGUITIES, OR INCONSISTENCIES PRIOR TO PR20CEEDING WITH THE WORK. 3. WINDOW SIZES SHOWN ARE BASED ON ANDERSON 100 SERIES ((CASEMENT). CONFIRM OWNER. CONTRACTOR SHALL VERIFY SIZES PRIOR TO ORDERING.. ROUGH OPETYPE AND MANUFACTURER WITH OWNER. CONFIRM GRILLS IN REIAR DOORS WITH WINDOWS NNING FOR VERIFY AND PROVIDE REINFORCINGBETWEENMULTTIIPLLEBUNIITSP(MIURLLED) AS I REQUIRED BY MANUFACTURER AND APPLICABLE BUILDING CODES. 4. WINDOWS MUST MET THE FOLLOWING CRITERIA: -GLAZING CLOSER THAN 18" TO THE FLOOR, EXCEEDING SIX (6)) SQUARE FEET IN AREA, IN A DOOR, OR WITHIN 24° OF A DOOR MUST BE TEMPEERED. 5. DIMENSIONING STANDARD ARE AS FOLLOWS -EXTERIOR DIMENSIONS AT BUILDING CORNERS REPRESENTS AN COUTSIDE FACE OF STUD/FACE OF CONCRETE DIMENSION. ERIOR •REPRESENTS ITTHE CENTER SIOF THAT OPENING, WINDOWS,ING AT CASED FROM THE CENTF9R AND DADOORS OPENING OR FACE OF WALL (OR FACE OF OPENING JAMB) OF THER -INTERIOR DIMENSIONING AT STUD WALLS REPRESENTS A DIMENSOON TO THE FACE OF THE FINISHED WALL (U.N.O.) 6. STRUCTURAL DRAWINGS AND INFORMATION NOT PART OF THESE FPLANS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND LUMBER MANUFACTURER 7. ALL WORK SHALL MEET FEDERAL, STATE, AND LOCAL CODES/ REtQUIREMENTS OTHERWISE. S. ALL WALL ANGLES ARE 90 OR 45 DEGREES UNLESS DIMENSIONED OR NOTED 9. PROVIDE FOR PEWTER FIN LEVER SCHLAGE DOOR HARDWARE (CONFIRM WITH OWNER). DOORS TO BE SOLID SMOOTH MASONITE 6—PANEL PRIMED AND PAINTED (CONFIRM WITH OWNER). ALL TRIM TO BE PAINTED (CONFIRM WITH OWNER)1, 5/^ SPEEDBASE, 2'{6" COLONIAL DOOR AND WINDOW TRIM. TYPICAL OPENING ARE BASED. FLOOR TILE ON ADDITIONAL �k" PLYWOOD SUBFLOOR, WALL TILE ON '/�" DUROfCK WITH MOISTURE RESISTANT GREENBOARD GWB THROUGHOUT BATHROOMS WHERE WAALL RECEIVES PLASTER SKIMCOAT. ALL CEILING TO BE WHITE WITH SMOOTH FINE%H, 10. STAIRWAYS AND LANDING SHALL BE IN COMPLIANCE WITH ALL 78Co CMR SECTIONS RELATING TO HANDRAILS AND GUARDRAILS. 11. CARBON MONOXIDE DETECTORS TO BE INSTALLED IN COMPLIANCE -WITH NICOLE'S LAW 12. ALL DUCTWORK AND HOT WATER PIPING SHALL BE INSULATED AN[b WHERE NECESSARY, A VAPOR BARRIER FOR THE DUCTWORK TO PREVENT; (CONDENSATION. 13. SMOKE DETECTORS HARDWIRED PER CODE ARE PHOTOELECTRIC TYfPE. PROVIDE SMOKE DETECTORS PER ALL LOCAL, STATE AND FEDERAL CODES. 14. PROVIDE HEAT DETECTOR IN GARAGE. 15. PROVIDE FIRESTOPPING AT ALL WALL CAVITY PENETRATIONS WITH MONCOMBUSTIBLE MATERIAL, BOTH VERTICALLY AND HORIZONTAL PENETRATIONS. 16. PROVIDE FIRESTOPPING AND FIREBLOCKING OF CONCEALED SPACEIZ AT BASEMENT WALL AND BETWEEN FLOOR LEVELS. 19. ALL WALL COVERING SHALL BE IN ACCORDANCE WITH CHAPTER 7'COF THE IRC. J" TYPE X GYPSUM BOARD SHALL BE USED ON ALL INTERIOR GARBAGE WALLS AND CEILING. 20.DRAWINGS HAVE BEEN PREPARED FOR 24%36" PLAN SHEETS. SCAA SHALL BE REDUCED ACCORDINGLY FOR OTHER PLAN SHEET SIZES. 22 STRIPER CIRCLE SHEET 1 OF 2 SHEETS 26'-5�" FOUNDATION NOTES 26'-5}" FRAMING NOTES - - - - - - - - - - - - - - - - - _ 1. FOUNDATION DESIGN BASED ON A MINIMUM SOIL RAFTE_ 1. NO SUBSTITUTIONS OF BEAMS/ / N JOIST SIZES CAN BE - _ BEARING OF 3000 PSF. 2. CONCRETE SHALL REACH 28 DAY COMPRESSIVE MADE WITHOUT ARCHITECTS APPROVAL. EL 100.00' EL. 99.50' EL 100.00' I STRENGTH OF 3000 PSI. 2. USE SPF 1 # /#2 OR BETTER FOR KD STOCK AND #2 SYP 3. PROVIDE 5/8" ANCHOR BOLTS A MIN OF 7" INTO EXTERIOR STUD WALL o (WITH NONTOXIC PRESERVATIVE TREATMENT)) FOR PT STOCK. �j CONCRETE WITH 3"X3"X34" PLATES AS SHOWN ON THE 0I 3. ALL LVL'S SHALL BE TRUS JOIST MICROLAMA 2.OE. NO n FOUNDATION PLAN AND 1-FT AWAY FROM CORNERS AND NOTCHING TO LESS THAN THE DEPTH GIVEN IN THE PLAN. EDGES OF BASEMENT WINDOWS. NOTE THAT THERE N INSTALL IN STRICT COMPLIANCE WITH MANUFFACTURER'S EL 99.50' SHALL BE A LEAST 2 BOLTS PER SECTION OF WALL RECOMMENDATIONS. DOOR OPENING TO BE PLATE. PROVIDE SILL SEAL BETWEEN CONCRETE AND 4. USE 2-2"X8" (2"X4" WALL) SOLID HEADERS (WITH CENTERED N ERED WITH WALKWAY SILL PLATE. ATTIC ACCESS WITH '/�" PLYWOOD U.N.O.). NOTE THAT IF HEADE-R DOES NOT FIT " DIA. ANCHOR I 4. PROPOSED FOUNDATION SHALL BE CONNECTED TO FOLD DOWN STAIRS FOR STATED ROUGH OPENING HEAD HEIGHT♦ OF WINDOW, REAR FOUNDATION BOLT AT 32" O.C. EXISTING FOUNDATION USING #4 BARS (18" LONG) CONTACT ARCHITECT FOR SUBSTITUTION. WALL EL 100.00' W/ 3"x3"xl" l � EVERY 18" DOWELED INTO EXISTING FOUNDATION (9" 5. PROVIDE FULL BEARING UNDER ALL PLYS (OF LVL. (MIN. 3 WASHER (TYP.) I I EMBED.) JACK STUDS). 54" 5. FOOTINGS TO BE ON UNDISTURBED EARTH WITH 2-#4 GARAGE 6. PROVIDE MIN. 2 JACK STUDS FOR ALL HEAiZERS OVER LONGITUDINAL REINFORCING BARS. PROVIDE 48" MINIMUM 0 0 o OPENINGS 6'-0" OR GREATER. 0 FROST COVER PROTECTION TYPICAL. UTILITY 7. PROVIDE TWO SIMPSON H2.5A HURRICANE (CLIPS AT ALL 4" CONC. SLAB FLOOR I I I 6. TYPICAL FOUNDATION WALL IN FRONT IS 4'-0"H X 8"W. u.� m L n RAFTER/TRUSS AND PLATE BEARING CONNETCTIONS. REINFORCED WITH 6 MIL o 7• STEEL REINFORCING. HORIZONTAL: PROVIDE (2)- N0. 4 8. ALL FASTENING OF FRAMING, PLATES, SILL$, SHEATHING, OVER 4" GRAVEL. 8" CONCRETE WALL REBAR CONTINUOUS IN THE TOP AND BOTTOM 12" OF AND OTHER WOOD MEMBERS SHALL BE IN ACCORDANCE FOUNDATION WALL AND (1) NO. 4 NEAR MID -HEIGHT OF WITH THE DETAILS SHOWN AND MINIMUM REQUIREMENTS OF 24"x12" CONC. THE WALL. VERTICAL PROVIDE (1) NO. 6 VERTICAL THE MASSACHUSETTS STATE BUILDING CODES. EL 100.00' FTG. BELOW 10" I REBAR AT 48" O.C. BETWEEN (BASED ON 780 CMR 9. CONNECTORS SHOWN ARE AS MANUFACTURFED BY SIMPSON STRONG TIE. SUBSTITUTIONS MUST BE APPFROVED BY EXISTING FOUNDATION CONCRETE WALL I TABLE R405.1 GROUP I SOIL CONDITIONS). THE 20 MIN. FIRE RATED DOOR ARCHITECT. INSTALLATION OF ALL TmRS SHALL BE IN DROP AT EXISTING DISTANCE FROM THE FACE OF THE SOIL SIDE OF WALL STRICT ACCORDANCE WITH THE MANUFACTNUFACTUFRERS GARAGE DOOR I I TO THE CENTER VERTICAL REINFORCEMENT SHALL BE AT r 1 INSTRUCTIONS AND MUST EMPLOY ALL REQtUIRED LEAST 6.75". FASTENERS. 4" SHELF ® EL. 98.50' FOR I '_ I 8. PROVIDE 2 COATS OF DAMPPROOFING AND SEAL ALL I I o 10. ALL CONNECTORS SHALL BE HOT DIPPED GALVANIZED. STONE VENEER (TYP. EITHER ROD HOLES. " 2x6 PARTITION WALL I 11. SPILT WOOD IS NOT ACCEPTABLE FOR ANY, (CONNECTION. SIDE OF GARAGE DOOR OPENING) I . I 9 CONFIRM ON I M PENETRATION LOCATION THROUGH HR UGH FOUNDATION (R-21 INSULATION) 12. ALL EXPOSED FRAMING MEMBERS SHALL BF TREATED PER EL 100.00' EL 100.00' IZ�l I AWPA REQUIREMENTS, MEMBERS IN CONTACiT WITH SOIL -• ACCESS, ETC. VERIFY IF SUMP PIT REQ'D AND CONFIRM I 16-FT x 7-FT GARAGE DOOR SHALL BE TREATED PER AWPA C23/C24 CfCA 0.60. JOB AB ELEVATION AT DOOR = 99.17' I LOCATION. SITE FABRICATION AND BORES SHALL BE TRREATED IN - - - - - - - - - - - - 10. PROVIDE FLOOR SLAB CONTROL JOINTS IN STRICT ACCORDANCE WITH AWPA STD. M4. _ _ _" ACCORDANCE WITH THE CODE. 13'-0" 13'-0" 13. ALL MANUFACTURED LVL WOOD FRAMING CMMPONENTS El 100.00' 11. THE ELEVATIONS SHOWN ARE FROM THE TOP OF 26 -0 SHALL HAVE THE FOLLOWING PHYSICAL PRCOPERTIES: � DOOR OPENING CONCRETE WALL. E=2.OX10-6PSI, F8=260OPSI, FV=285PSI. EL. 98.50' (TYP.) 12. OPTIONAL -PROVIDE 6" ADS PERFORATED FRENCH 14. ALL PLYWOOD WALL SHEATHING EXTENDS TCO TOP OF WALL DRAIN PIPE WRAPPED WITH SILTATION CLOTH BELOW BASEMENT 2x6 EXTERIOR WALL PLATE AND TO BOTTOM SILL ADJACENT TO FFOUNDATION. 16'-6" BASEMENT GRADE. RUN TO DRYWELL. MNFA 0 (R-21 INSULATION) 15. ALL FASTENING OF FRAMING, PLATES, SILLS;, SHEATHING 4 -9„ 4,-9" AND OTHER WOOD MEMBERS SHALL BE IN ♦ACCORDANCE WITH THE DETAILS IN THE LATEST INTERNATFIONAL o RESIDENTIAL CODE AND 140MPH EXPOSURE= B GUIDE TO EL 100.00' WOOD CONSTRUCTION IN HIGH WINDS AREAS FOR ONE - AND TWO-FAMILY DWELLINGS, WHICHEVER I�8 MORE STRINGENT. EXISTING FOUNDATION STRUCTURAL NOTES DROP AT EXISTING GARAGE DOOR EL 100.00' (ASSUMED) 1. STRUCTURAL DRAWINGS (BY OTHERS) FOR ROOF TRUSSES FRONT FOUNDATION AND GARAGE DOOR HEADER ARE TO BE USF._D WITH THE WALL 26'-0" ENTIRE SET OF DRAWINGS. GARAGE PLAN 2. ALL SAFETY REGULATIONS ARE TO BE STRICTLY FOLLOWED. METHODS OF CONSTRUCTION AND ERECTIONI(OF ALL FOUNDATION PLAN SCALE: 1/4"=1'-O" STRUCTURAL COMPONENTS ARE THE CONTRASCTOR'S RESPONSIBILITY. SCALE: 1/4"=1'-O" 3. THE CONTRACTOR IS RESPONSIBLE FOR DISSEMINATION OF ALL DRAWINGS AND REVISIONS. 4. REASONABLE CARE HAS BEEN TAKEN IN THE PREPARATION OF THE STRUCTURAL DRAWINGS AND SPECIFi'4CATIONS, HOWEVER THE ENGINEER DOES NOT GUARANTEE AGAINST aex.a+anaaa�ra�xmwan+c€n wine HUMAN ERROR AND FOR THAT REASON IT I$ IMPERATIVE CONTINUOUS rx r rx Exaxru THAT THE CONTRACT SHALL CHECK AND VEFRIFY ALL 12 RIDGE VENT " n DIMENSIONS, ELEVATIONS, AND CONDITIONS PAT THE SITE IN ROOFING SHINGLES g r WITH 15LB UNDERLAYMENT r.ekrwas€oa"aor+ r--Faxseo�taaenxxH� roaee ax"� «w+s7 COORDINATION WITH THE DRAWINGS. ALL DISCREPANCIES vmz,caa"'// SHALL BE BROUGHT TO THE ATTENTION OF 1THE ARCHITECT xrr IN WRITING BEFORE PROCEEDING. CDX PLYWOOD ICE AND WATER ROOF TRUSSES SHIELD 72' SAVE ALONG mar.»x ETsrtslFat[ + I�rVcEais+ D,POCE "3MMrWEAM" (BY OTHERS) PARTIAL HEIGHT BLOCKING V-ram aEnnnM�m�am»en BETWEEN TRUSSESWN ,,c s cwnse ro rrro" ALUMINUM FASCIA, ". �, a a �a asmu,E"vm_J� , " DRIP EDGE AND 10® 16" O.C. STRAPPING GYPSUM BOARD g GUTTER (TYP.) p OPPOSMWEOF-4"TMG s+*« CONTINUOUS ,ma €r.rmocaewccrax++sa ow 60Como ORC .xMba �• WITH. ffifI 0"G4.1M1Yii1FD86x "N.ShS *wrc v.ro ,u `°'�"m'ct�"' s _ SOFFIT VENT �' a rya€nrasl:acsr�msus,as j I 2x6 EXTERIORIrx T;�pLx�nsa€Facas.+a3 ANCHOR BOLT °' WALL (TYP.) (SEE FOUNDATION PLAN) " ZIP SYSTEM 2X6 P.T. SILL PLATE WALL SHEETING WITH SILL SEAL 6 +°' as cF ,aa�m _ - - - - - - - - - d 0 :#Vaf P7PFK Z 7_4" CONCRETE SLAB FOUNDATION WALL e"neararel 2 1"x24" FOOTING FRONTELEVATION SECTION TYPICAL SECTION For SI, Iinch =25.4rnm,l#M 3048mm. SCALE: 1 /4"=1'-0" FIGURE R602.10.6.3 METHOD PFC -PORTAL FRAME AT GARAGE DOOR OPENINGS IN SEISMIC DESIGN CATEGORIES A, BAND C 22 STRIPER CIRCLE SHEET Z OF 2 SHEETS TOWN OF DARTMOUTH ZONING REQUIRMENTS: GENERAL RESIDENCE B DISTRICT MINIMUM SETBACK TO STREET LINE = 60.00' MINIMUM SETBACK TO SIDE LINE = 20.00' MINIMUM SETBACK TO BACK LINE =20.00' EXISTING HOUSE LOCATION BASED ON EXISTING; EXISTING HOUSE LOCATION BASED ON EXISTING FOUNDATION AS -BUILT DATED APRIL 14, 1997 BY SITEC ENGINEERING FILED WITH THE TOWN ON APRIL 17, 1997. V1 OF 'ell 14 o� HONE M. CIVIL Na 49821 BUILDING DIMENSIONS AT: 22 STRIPER CIRCLE FOR: ANTONIO AND FILOMENA SCQUSA A� I� At vvv SCALE: T'.= 40' CITE: 3130/19 IC1a