Loading...
BP-042PRECAST CONCRETEe`�-j'�'� ,. SEPTIC TANK I'�*---- BUILDING GRADE TOP OF FOUNDATION ELEVATION = 106.001 LOT 4 I N LEACHING CHAMBER TRE DISTRIBUTION SEPTIC I TAN, WATER 'ABLE IEST DATES :N:. / 2$ / b8 BY: KEVIN FORGUE ENDY HENMIR.SON 7AD: 3 / 28 / 88 BY: KBIN FOR01117 6Pe -* 7'" 411, CROSS SECTION THR ' m LOT 3 � �, Area 629081 SF 44GI fn -� TP ice. 103 A H vQ�I N ss�o . NT N qq NOT T BEN( SPIKE IN �( ELEV 2 PARKING G SP/ACE: i• XISTING CONTOL PROPOSED CONT SOIL TEST HOLE I ' f lo' I 35' —� , _104.0' ! ! 10 ELEV = 102.6' (MIN) 104.� ELEV- ELEV.= FINISH GRADE w I COVER JOINT INV. = 101.06' _ e • ; a _ HEADERS LAID , WITH PLANK 1 I " FLAT FOR 2 FEET INV= 101.06 2 (MIN.) - /g - /2 4" SCHED. 40 PVC OR —� -Ni z SLOPE = 1 % `. - 0 6 BLDG. PAPER WASHED STONE - - 3"MIN. -- 4 CAST IRON PIPE LIQUID LEVEL -ice 4" PVC PIPE; 4 ,PVCOPE ( i E I ■ 9 ti i A 6 !4 ! 3/4"- I I/2 102.20 101.83' O' -— -- I 101.67' a: I WASHED STONE Z INV=. INV= I - ( INV= INV=101.16 >� ® ® ® EFFECTIVE DEPTH = 0.9 o i PVC OR INV=101.32--J IRON a �-6" M1H. SANITARY TEE 3' -�-E-- 2 - 4' x 8' FLOWDIFFER UNITS ` 3' I m 2 ; BASE ELEV. PRECAST CONCRETE ! OVERALL: 10' WIDE x 22' LONG = 100'.10'. TANK LIQUID CAPACITY =1000 gal. 3" DISTRIBUTION BOX GWT = 96.1 ' PRECAST CONCRETE LEACHING CHAMBER DISPOSAL TRENCH ELEVATIONS MUST NOT BE PRECAST CONCRETE CHANGED WITHOUT BOARD .,� SEPTIC TANK OF HEALTH AP T d f APPROVAL W Your Draw* klusl Be Kept - ' � At Ue Building D�1rin' The Q4 y Progress ��3s ��{lore. BUILD.r�13 Dx,-i ARTt,1- ��T cz , ^� � era,, ,... CROSS SECTION THROUGH SEPTIC SYSTEM S A S To.'7 4 d f.J°e�d E6 BUILDING GRADE TOP OF FOUNDATION ELEVATION = 106.00' a 4 n As Built Survey must be ibmittod -�Z-a tb2 Building pt • prior to calling for foundation inspection or w flyikrt �r cerstruction . BOARD OF HEALTH INSPECTION REQUIRED WHEN EXCAVATED RESERVE A LOT 4 i LEACHING CHAMBER TRJ DISTRIBUTIO E 151.65' N 0 m LOT 3 �,� . ft Area 62,081 SF Q �Rq UIN 9} qF Ssi T L 0- 0 Cis /03A c' °o / qq N BOX SEPTIC TANK 7,ram, job BENCH MARK SPIKE IN POLE 210/128 ELEV = 100.00' A PROPOSED THREE BEDRD M , . �o°� -4 2 RA H 11 �— PARKING SPACES iT IN, / f �� •' N- �G�'y �J tot zz- \ y, 100 17ETLANDS / / 99--��- /�� ✓t BUFFER ZONE o t i , ,f , t,g5 �, ��- 0 tot:, fir) i� NOT TO SCALE LOT 2 SOIL AND WATER TABLE TEST DATES PERK TEST TAKEN: a / 78 / 88 BY: KEVIN FORGUE WITNESS. By--- WENDY HENDERSON WATER TABLE'--" `3 % 28' / 88 BY: KEVIN FORGUE WITNESS. BY: WENDY HENDERSON SCALE PLAN FEET 60 30 0 0 60 This System Is Not Designed For Garbage Grinder, Whirlpool Or Other High Water Use Devices. LEGEND t XISTING CONTOUR - PROPOSED CONTOUR SOIL TEST HOLE WETLANDS BUFFER ZONE ,=0 � AMID Allom � ...' TEST TAVEN 9Y SUbJECr +I'�Cf •� r p SIIEET NO UI'_ CLIENT- �Bf�1)�JCi1�>c21� JON NO DATE _z*LSITE LOCATION_—LIECD RA_ PLMT`G LOTJ SOIL STRATA DEPTH OF STRATA DESCRIPTION T. •,�� I t)3 r\ L4._..P.x� mac! �1.v E .S.r.rC icr oAA ;--rr SOAK Depth of We /2-0 " !).,.�/C 4 A. /. k Depth to rust - ��ao� . /r or d c` c Depth to water %Z " >4 Z '. F : /v, o v r n • 1 Depth to ledge l Inspector 4., !�. // , gl�r.tJ.hc.r;, 11 .. _ lf'.r. 1 ;.L CrlO. 1t J Perc test of V y" 'Time of begiinning Time of end Perc. role of inches in minutes COMMENTS: LOCATION OF T.P. LOCATION OF RESERVE AREA ACTI0if OF 1OAI:I rILE WATER -TOWN —no BACKIIOE:. .��L,t�n— �IIh � APR 11 15U SOIL TEST REPORT DATA DESING DATA & SPECIFICATIONS j AVERAGE DAILY FLOW PROPOSED 3 BEDROOM DWELLING ® 110 GPD PER BEDROOM = 330 GPD SEPTIC TANK SIZING i 150% ADF = 1.5 (330 GALS) = 495 GALLONS THREE BEDROOM DWELLING REQUIRES 1000 GALLON TANK (MINIMUM). LEACHING FACILITY CALCULATION TRY: 2 UNIT FLOWDIFFUSER TRENCH WITH 3 FEET OF STONE ALL AROUNG. SIDEWALL: 64 LF PERIMETER X 0.96 FT DEEP = 54 SF 54 SF X 2.5 GPD / SF = 135 GALLONS BOTTOM: 22 FT LONG X 10 FT WIDE = 220 ' SF 220 SF X 1.0 GPD / SF = 220 GALS DESIGN TOTAL = 274 SF = 374 GALLONS i DESIGN = 374 GALLONS > REQUIRED = 330 GALLONS OK Gravel z- _ Pit — Gravel Pito CZ O' 162. — �. '.�LOCIIS —� r B. 0. H. STAMP pfpE APPROVED D ;A - R. T,I;_ � . -p, u x 1\ BOARD of HE 1LTE - - T'late -r- Z /- ty _ ravel DARTMOU A I LA _ ...., t {— B. 0. H. NOTES _ 83IF — - 0 — CONRAILENGINEE I `am 144 _ RS AS -BUILT PLAN & CERT' I� N ,� STATEMENT RE r;LI ��:- Th:!E APPROVAL BY THIS O'FFI�E r' �.. HOES NOT GUARANTEE THE . r EFFECTIVENESS OF ANY LOCATION MAP INSTALLATION I Q�t�RTMOUTH BOARD OF HEALTH ?EST TAKEN �e+" gv SUAJECi r0-- . I --- SUEEr N0 17 • CLIENT Aid o—pe i " tJ,2�____— J00 H0. DATE N4_ c�-1R�y.f'r,, - SITE LOCATIONfieeco PLATC� Lot 3 SOIL STRATA DEPTH OF STRATA DESCRIPTION /2n " - t„rdEr_ (rnn r vepm or note /7JI ' Depth to rust Depth to water 6 o" t 21 Depth to ledge „Ak r„"_:... a�r� ' Inspector Perc test of Time at begiming _ Tittle at end ENGINEER Perc. rate of inches in minutes /%✓,h F.�„e COMMENTS: LOCATION OF T.P. Lnf:ATION OF RESERVE AREA WATER - TOWN r z BACKHOE: _ 1+� �,► �L� SOIL TEST REPORT DATA GENERAL NOTES THIS SEPTIC SYSTEM HAS BEEN DESIGNED IN ACCORDANCE WITH THE RULES & REG- U ATIONS OF 310 CMR 15 (TITLE V) OF THE COMMONWEALTH OF MASSACHUSETTS AND THOSE OF THE TOWN OF DARTMOUTH BOARD OF HEALTH. THE REQUIRED INSPECTION SCHEDULE DURING THE PROCESS OF CONSTRUCTION SHALL EE ARRANGED BY THE CONTRACTOR WITH THE BOARD OF HEALTH PFIOR TO THE COMMENCEMENT OF CONTRUCTION. 1000 GALLON SEPTIC SYSTEM, 5 OUTLET DISTRIBUTION BOX AND TYPr L LEACHING CHAMBERS (FLOWDIFFUSERS) SHALL BE STANDARD DUTY DESIGN AS MANUFACTURED BY A. ROTONDO & SONS, INC. OR EQUAL. ALL PIPING OUTSIDE THE DISPOSAL AREA SHALL BE SCHEDULE 40 4" PVC PIPE WITH ALL JOINTS SEALED WATERTIGHT. ALL WASHED STONE SHALL BE FREE OF IRONS, CLAY OR FINES AND SHALL BE SATISFACTORY TO THE DARTMOUTH BOARD OF HEALTH. THE SYSTEMIS NOT DESIGNED TO ACCOMODATE A GARBAGE DISPOSAL SYSTEM OR OTHER HIGH WATER USE UNITS. THE PROPOSED SEPTIC SYSTEM IS NOT LOCATED WITHIN THE CONE 0` INFLUENCE OF ANY MUNICIPAL WELL NOR ARE THERE ANY PRIVATE WELLS LOCAifED WITHIN A 100 FOOT RADIUS OF THE PROPOSED SYSTEM. EXCAVATE ALL TOP, SUB ANY OTHER SOILS ENCOUNTERED DOWN TO THE COARSE SAND, GRAVEL STONE LAYER AND TO 25 FEET OUT FROM ALL SIDES OF THE TRENCH BACKFILL TO ELEVATION 101.5 FEET WITH CLEAN COARSE SNAD OR GRAVEL HAVING A PERCOLATION RATE OF LES THAN TWO MINUTES PER INCH BEFORE AND AFTER COMPACTED PLACEMENT IN ACCORDANCE WITH THE REQUIREMENTS OF 310 CMR 15.02 (17) [CONSTRUCTION IN FILL]. ELEVATIONS SHOWN ON THIS PLAN ARE BASED ON AN ASSUMED DATLIM PLANE. P. E. STAMP SEAGE DISPOSAL SYSTEM PLAN jt� OF CLIENT: THOMAS W. MARTIN ors- � h POST OFFICE BOX 2108 u FALL RIVER, MAS5ACHUSETTS 02722 F G f4 47I c BRISTOL COUNTY EA75INEERING INC. Swansea Professional Park R• L. S. STAMP 1010 Grand Army Highway - Route Siff eF r� s � Swansea, Bristol County Massachusetts 02777 • �ti«s x z �osEPH A -, SPECS.: LOT 3 - LARGO SUBDIVISION ASSESSORS PLAT 66 -- w 1 1-7- ZREBIEC No 272? a _, ZQz REED ROAD, DARTMOUTH, MASSACHSETTS Contact Person: MICHAEL E. ZfOBRO, P.E. Address: Bristol County Inc., Swansea, MA Engineering, Tel.: 1 - 508 - 676 - 9880 91M016 i_ _ _, � �. r { Fb I N Z.4 f o4- . f -- —_— ---I - (U _�— --_— L J l— L_ i — --- -- I _ I i 3-- _ ' _ 3" — _ I .G-_ s--ro►�� J�; ` �oxZoGollc._b�T-rh�C --I �.-a" T- c I P-a -- — -- i YOUR DRAWING MUST BE KEPT An ,.?his Built Survey must he I AT THE BUILDING DURING THE sub itted to th B;-i'ding i PROGRESS OF THIS WORK. Dv is • prior to C. -, rg for �' _ a f ; . idation in:pn-ction, or SO1\E I Town of Dartmouth UL# 1 �Yl G ^:ray f- -+ther c,�: :• ...a � DETECTORS - CEIL NGr �-- - -- -- �, iQU -- Zq- x b� N YOUR DRAWING MUST BE KEKn As Built Survcy must be AT THE BUILDING DURING THE PROGRESS OF THIS WORK. submittcd tc) thL,-, Landing Do-,yt- prior 'il.-o caE.--ig for BUILDING DEPARTMENT Town of Dartmouth a fouim paction mpection or any fir-rther construction.