Loading...
BP-84012ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERIIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER —CONDITIONING INVERTER. BLDG `BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY —RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING-Dlgltd��y SIgC12Ci_%y Hussein EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, kazanl__kdZdllFSB FIRE SET —BACK A SIGN WILL BE PROVIDED WARNING OF THE u5SeI n GALV GALVANIZED HAZARDS PER ART. 690.17. Ddte: 2017.01.09 14:44:20 s, r GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY $.f 05'00` HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. _ I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL OF 04 3 3, DISCONNECTING MEANS PER ART. 690.31(E). �`k� '?, , MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN, (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. HSIIN A g NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE x OC ON CENTER UL-LISTED LOCATION PROVIDED BY THE ' PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING o. 51 �. POI POINT OF INTERCONNECTION PV PHOTOVOLTAIC HARDWARE. 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. f NAL, S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT VICINIT I MAP INDEX W WATT PV1 COVER SHEET PV2 SITE PLAN 13R NEMA 3R, RAINTIGHT n ` PV3 STRUCTURAL� VIEWS t �� �' PV4 -UPLIFT CALCULATIONS PV5 THREE LINE DIAGRAM LICENSE GENERAL NOTES `° Cutsheets Attached 7— GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION OF THE MA ST ELEC 1136 MR ATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2017 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. ax MODULE GROUNDING METHOD: ZEP SOLAR` j AHJ: Dartmouth ` REV BY DATE COMMENTS r ` REV A NAME DATE COMMENTS UTILITY: NSTAR Electric (Commonwealth Electric) CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER J B-027L} 735 O Q PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE TIM 1 EpLANC — IVI L U c� BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: Tim Leblanc RESIDENCE Wade Altken Palmer-; NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing -Insert 107 MILLERS DR ,t 8.505 KW PV ARRAY '''lieSolarCitv PART IZ OTHERS OUTSIDE THE RECCONNECTION Will DARTMOUTH, MA 02747 ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES THE SALE AND USE OF THE RESPECTIVE (27) LG # LG315N1C—Z4 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN 24 St. Martin Drive, [Building 2, Unit 11 PERMISSION OF SOLARCITY INC. INVERTER PAGE NAME: SHEET: REV: DATE T: (650) 638 Marlborough,' 't 01752 SOLAREDGE 638-1029 SE7600A—US002SNR2 COVER SHEET PV 1 1/9/2017 (888)—SOL—CITY(765-21489) www.solarcitycoro I j woo-411=108-MMAk (60*Z-S9L) up-Jos-(M) LIOZ/6/l 6Z61-8f9 (049) :A aZOC—m (Ogg) ui Z Ad Nb1d 31l5 ZdNSZ00Sfl-V009L3S 3903dVlOS ZSLlO VW '46no�ogNoW 11 uun 'i 6ulPlln9 'anua union is tiZ 31Va :A3d :133HS :3WVN 39Vd 31312DANIJIOS ONI uIOL'" 30 NOISSIW213d NRLIHM 3H1 1nOHLIM 9.1I:8Wdlnb3 UI08VlOS 3AI103dSIN 3H1 JO) �Z—O lN5 L2OI 9l (LZ) `1�� Al!:)jeloS I \ I \ I /WMV J A A \l Ad MA 909 S t tb M V N ' Hl (- o hiW d a �a S�I Lo s3inaon 3Sn aNV 31VS 3HL HLIM NOI103NN00 NI 1d 10X3 'NOl1VZINVO80 11 �laSUl-6UIl�SD13 M {�n dU100SZNI ' •`��\ IaualDd-ua�}ly apDM 3�N�QIS��i �uplga� ��l IIIW -I �Nb'�83 I WIl RISAS ONI1NnOW NO 3110 M NI o3SOl0�l 0 381rlo -nVHS1 ON ONI u108V10S 1d30X3.:3N0ANV 40 MM38 :NOIS30 :NOI1dwga :N3WO 3SIM38d (� / / (l 00 g L L t L Z O-8 I :838WnN OOF 3H1 and a3sn 39 M N 11VHs 03NlV1No0 N1383H NOl1VV4WjNl 3H1 — 1VILN3G1JNO0 S M 'TZ 'OT .10 3 ,T = ��Z£/£ :@leas NVId DES 03HSV0 SI 1N3Wdino3 WINI N1 03d 38V S1N3A 9Nonaodd 1V3H Q 33N3J/31V9 — M0 31N1 NO Nnd iinaNOO --- NOIN31X3 NO NM iinaNOO SNOIIVOO13300NViS Q NMo(LLnHS OldVd asa d3i3W W31SlS Ad 031VO1030 O S13OVI ONINdVM V dliN30 OVOI FBI d 5n S138VI V 13NVd NOuneid1S10 3 S138dl V XO8 d3N18W0O/NOLONn o0 O S138dl ONINdVM 2 103NNOOSIO OV S130VI ONINdVM V 103NNOOSIO 00 3a OOSIO 30 031Vd931N1/MNd31d3ANl Sul 130V1 ONINdVM N d3134 Alma (3) asn0H d0 Tuojd ®NDJDI 0 4 h N AjoTS T ,kdOIS albuluS dwoO :IVld31VW -' `V NIBS n�1 ,_.. 0i :Hif1WIZV ),VddV t0T H1f1WIZV tdW _ + r OZ:H011d kVddV OZ :H011d nul i i O Ajo4S T ;kNO1S 316ulyS dwo0:lVld31VW © W OV voi :Hinvio Avmv toT :HinmzV ZdW 0£:H01Id AVddV O£ :H011d ® SIDE VIEW OF MP4 IVTS MP4 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" 39" 0" STAGGERED PORTRAIT 48" 19" 64" 0" TOP CHORD 2X4 @ 24" OC BOT CHORD 2X4 @24" OC ROOF AZI ARRAY AZI 104 PITCH 20 STORIES: 1 104 PITCH 20 Comp Shingle X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. HUSSEIN A. u� KAZAN No. 52612r a 5'-4 LWt (E) &`ON SIDE VIEW OF MP2 NTS B PV MODULE 5/16"x1.5" BOLT WITH 5/16" FLAT WASHER INSTALLATION ORDER ZEP LEVELING FOOT LOCATE RAFTER, MARK HOLE ZEP ARRAY SKIRT (1) LOCATION, AND DRILL PILOT HOLE. ZEP MOUNTING BLOCK --------- ----------- ATTACH FLASHING INSERT TO (4) (2) MOUNTING BLOCK AND ATTACH ZEP FLASHING INSERT (3) TO RAFTER USING LAG SCREW. (E) COMP. SHINGLE (1) INJECT SEALANT INTO FLASHING (2) (3) INSERT PORT, WHICH SPREADS (E) ROOF DECKING SEALANT EVENLY OVER THE ROOF PENETRATION. 5/16" DIA STAINLESS LOWEST MODULE SUBSEQUENT MODULES STEEL LAG SCREW INSTALL LEVELING FOOT ON TOP (2-1/2" EMBED, MIN) (4) OF MOUNTING BLOCK & SECURELY FASTEN WITH BOLT. (E) RAFTER 1 STANDOFF CONFIDENTIAL — THE INFORMATION HEREIN THE JOB NUMBER: J B-0274735 00 PREMISE OWNER:: TIM LEBLANC CONTAINED SHALL NOT BE USED FOR BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: 107 MILLERS DR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 W Flashing -Insert PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES. DARTMOUTI uI, MA 02747 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (27) LG # LG315N1C—Z4 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER:. PERMISSION of SOLARCITY INC. SOLAREDGE # SE7600A—US002SNR2 MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" 39" O" STAGGERED PORTRAIT 48° 19" 64° 0" TOP CHORD 2X4 @ 24" OC BOT CHORD 2X4 @24" OC ROOF AZI ARRAY AZI 104 PITCH 30 STORIES: 1 104 PITCH 30 Comp Shingle X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. DESCRIPTION: DESIGN: Tim Leblanc RESIDENCE Wade Aitken -Palmer 8.505 KW PV ARRAY 24 St. Martin Drhve, Building 2, Unit 11 PAGE NAME SHEET REV: DATE: Madborou.r9h, MA 01752 T: (650) 638-102M F. (650) 638-1029 STRUCTURAL VIEWS PV 3 1 /9/2017 (888)-SOL-CITY (765--2469) www.solarcity.com UPLIFT CALCULATIONS I I SEE SEPARATE PACKET FOR STRUCTURAL CALCULATIONS. CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER: J B-0274735 00 PREMISE OWNER: TIM LEBLANC DESCRIPTION: Tim Leblanc RESIDENCE DESIGN: Wade Aitken -Palmer A*,�� SolarCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: 107 MILLERS DR 8.505 KW PV ARRAY /�, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing -Insert PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: DARTMOUTH, MA 02747 24 St. Martin Drives Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (27) LG # LG315N1C—Z4 PAGE NAME SHEET: REV: DATE: Modboroug411, MA 01752 T. (650) 638-1028, R.(650) 638-1029 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION of SOLARCITY INC. INVERTER: SOLAREDGE # SE760OA—US002SNR2 UPLIFT CALCULATIONS PV 4 1/9/2017 (888)—SOL—CITY (765--2489) www.solarcity.com vrwviw �r�w IvIAIIN F'ANLL SNLCS GENERAL NOTES INVERTER SPECS BOND (N) #8 GEC TO TWO (N) GROUND Panel Number: NoMatch Inv 1: DC Ungrounded - MODULE SPECS LICENSE RODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number: 96440696 INV 1 - (1) SOLAREDGE # SE760OA-US002SNR7 LABEL: A - (27) LG # LG315N1C-Z4 Inverter, 76,OOW, 240V, 97.57a w Unifed Disco and ZB, RGM, AFCI V GEN #1(,138572 Underground Service Entrance INV 2 P Module; 315W, 292.7 PTC, 40mm, Blk Frm, Wht Back Sheet, MC4, ZE Mono ELEC 11�36 MR INV 3 VOC1 40.6 Vpmax: 33.2 E 225A MAIN SERVICE PANEL Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E) 20OA/2P MAIN CIRCUIT BREAKER CUTLER -HAMMER Inverter 1 20OA/2P Disconnect 3 SOLAREDGE 1 (E) LOADS A SE760OA-US002SNR2 DC+ - - - �- L1 L2 - 40A/2P < _ N q - - — -- - -EGC/ --------- GFF EC I I DC- MP 2: 1x112 r- - - - - ------— - - - - --- - - - — - - - - EGC DC+ I DG I I DC+ 4DC+ - - DG C- MP 1: 1xI15 EGC --GC N---------—--------- c EGC/GEC J (I) Conduit Kit; 3/4' EMT -L z ----1 TO 120/240V I I� SINGLE PHASE I i UTILITY SERVICE I I I I I I I � I I, I i 290V GND ---TN PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP Poo (1)CUTLER-HAMM�R # CH240 PV BACKFEED BREAKER (1)CUTLER-HAMMER DG Breaker, 40A 2P, 2 Spaces, Tan Handle A # 222URB �� (2)GrovrLd Ro# Disconnect; 60A, 24OVac, Non -Fusible, NEMA 3R 5//8 x 8, Copper - (1)CUTLER- AMMER DG100NB Ground%Neutral Kit; 60-100A, General Duty (DG) (1 W, THWN-2, Black O (1) AWG #B, THWN-2, Red (I )AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC ImP=32 AAC .....70 )AWG #81. THWN-2, Green EGC GEC - 1 Conduit Kit; 3 4' EMT ....(.)........../ .............. PV (27)SOLAREDGEP400-5NM4MZM D� PowerBox ptimizer,400W, ZEP Ind ( 1) AWG #6, Solid Bare Copper 1) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. 2„ /ADDITIONAL LECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E)) ELECTRODE O (2)AWG #10, PV Wire, 60OV, Bladc (I WO #6, Solid Bare Copper EGC (1 Conduit Kit; 3/4" EMT Voc* = 500 Vmp = 350 VDC Isc — 15 ADC VDC Imp;= 10.66 ADC ... , , O ...... , , , (2 AWG #16,PV Wire, � 600V, Black (1)AWG #6, Solid Bare Copper EGC (1) Conduit Kit;. 3/4" EMT Voc 500 Vmp = 350 VDC Isc - 15 ADC VDC IMP- 13.32 ADC .., CONFJJENIIAL -THE INFORMATION HEREIN CONTJNED SHALL NOT BE USED FOR THE : JB-0274�35 OO PREMISE OWNERp DESCRIPTION: BENEFIT OF ANYONE EXCEPLSOLARCITY INC.,YSIEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR INm PART TO OTHERS OUTSIDE TIM LEBLANC Tim Leblanc RESIDENCE. 107 MILLERS DR V4 W FIOShIn g-Insert FINVERTER. THE RECIPIENT'SP ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE 8.505 KW PV ARRAY ~ D A RTMOUTi�� MA 02747 G # LG315N1C_Z4 SOLAR4CITY EQUIPMENT, WITHOUT THE WRITTEN PERMI'SION OF SOLARCITY INC. SE760OA—US002SNR2 PAGE NAMEbGE THREE LINE DIAGRAM Wadefftji •, ®la ��St Martin Drive, Building-Z Unit 11 SHEET: Marlborough, MA 017,52 T. (650) 638-1028 F: (650)) 638-1029 PV 5 1/9/2017 (888)-SOL-CITY (765-2489) wwrw.solarcicltycam 'ONI A11ONMS d0 NOISSIAN3d N311IN 3Hl! 1 1nOH1N1 '1N3NVdln03 ALI021V10S 0 3AIL33dS31 3HL 30 3Sn ONV 31VS HLNA NOLL03NN0O NI 1d3OX3 I woO•ATpJe!os*mmM (68tiZ-S9L) 'NOIIVZINVONO S.IN3IdI03N 3W 30IS1n0 S`M10 Ol IM NI 80 310HM NI 6ZOT-8£9 (OS9):A 8ZOT-8£9 (OS9):l ZU+6 VD'ODILW ueS _ 03SOlOSlO 38 11 11VHS NON "ONI AlIONV10S 11d30X3 3NOJ.NV d0 lIJ3N38 3H1 AeM-!AJeap SSOE ,�j �►�t� 2l03 03Sn 38 ION 11VHS 03NIVINOO NI383H N(b[IV14)AOJNI 3HL — lVLLN30UN0O r rwgk uo!}oauuoo lain }o }u!od (IOd) - ® VS'069 03N ' Ja}alN}!i!}fl (W) y E a o Ja p 0 d :r q Ja}ua0 peol :(0l) 4 (IOd) (ov) r lagal }oauuooS!Q 0a pa}eJ6a}ul y}!M Ja}Janul :(ANI) A _ -.. I!npuo0 un-�:j Jo!Ja}ul `•(01) _ }oauuoos!Q OQ (Od) hued uo!}nq!J}s!Q (a) ,mgpn xo8aau!quloO (8O) Z'O'-K'06903N WOO d }!npuo0 (0) bS'069 03N !-V*L6: 069 03N �} ® � (IOd) (Od) }oeuuoosla ov :(ov) .ap00 Jad ll l - :uo! eoo a e J } q :uol}eool lagel ICI, -'8' b9'069 03N :9p00 Jadf (IOd) :uo!}eool logel (17)L ['069 03N t, :apoO Jad (80) (00) l :uopool logel .. tb'8'V9'069 03N � - :apo0 Jad �< :uo!}eool lagel (0)9'069 03N r :9p00 Jad r . ` (ANI) (00) �rt� �� s :uol eoo a e ? L'8't,9'069 071N' :apoo Jad (IOd) ®vA :uo!}eool lagel ... .f .°'kmg ES'069 O3N e J7 (0)99'069 03N :apo0 Jad :apoO Jad "© ��� a �. (AN1) (00) r s I Z'O'K'069 O3N :. 4 a3a.NnmiONf1 WOO Jad As S1 2131Z13ANI . �_+ : _ = �� - 'bra. ® @ :uo!}eool lapel N3HM a3S(} 38 Ol E'`J' 6 (3)S£'06903N ��� 3p ® ® 0690 N 31L '069 03N ::apo0 Jad apoO Jad y .... £.ap°0 ad (nNl) (04) v (I0d)(0t/) „� ®v (80)(0) r _ a tl9N i J uoI eoo a e :.. :. :uo!}eool lapel ,..._ r i Single Phase Inverters for North America SE3000A- US/ SE380OA-US/SE5000A- US/ SE600DA-US/ SE7600A-US / SE10000A-US / SE1140OA-US Nominal AC Power Output 3000 3800 I 5000 ., v.6000 i 7600 9980 @ 208V 11400 VA Max. AC Power Output 3300 4150 I 5400 @ 208V 6000 8350 ` 10800 @ 208V ,,,,,,,,,,,, ........................................ I, 5450240V..10950 �a 240V .. • .. . 12000 .. • VA OutputAC Voltage Min.-Nom.-Max.iti ✓ � ' AC Output Voltage Min.-Nom: Max.i'i ' 211- 240 - 264 Vac ✓ '� `� ✓ ✓ iEj ✓ ✓ ........................................ ......... ,........... ,......... 1................................. AC Frequency Min: Nom.-Max.M 59.3 - 60 - 60.5 (with HI country setting 57 - 60 - 60.5) Hz• Max. Continuous Output Current .. ..... 12.5... ('•... v16..,.. �..21_�.240V _„...,.25„..., 3- ,,,A . . GFDI Threshold 1 A Utility Monitoring Islandmg Protection, Country Configurable Thresholds Yes i Yes Maximum DC Power(STC) (t 4050: -. 5100 . 6750 8100 10250• 13500 15350 1 W Transformer less Ungrounded Yes ......... .... Max. Input Voltage 500 .,No DC Input Voltage - 325 @ 208V / 350 @ 240V Vdc i............... ............... Max: Input Currents i 9.5 13 - 16 5 @ 208V i 33 @ 208V 34.5 ..:.:... .....:. .. ...........�............. �. 15 5.@ 240V. �. . �: 30 5 @ 240V Adc Max. Input Short GrcuitCurrent ........ ."'..,............, Reverse -Polarity Protection Ground Fault Isolation Detection 600ks Sensitivity . • MaximuminverterEfficiency 97.7 98.2 983 98.3 9g 9g gg %' ...... ................ .............. �........ .e• .97.5@208V 97@208V 97.5 CEC Weighted Efficiency 97.5 .) 98 I 97.5 97 5 ...... ..... III 98 @ 240V 97 5 @ 240V ......:.. ....... ....< 4.............. W Nighttime Power Consumption < 2 5 - , ADD ITI0NALrfEATURES Supported Communication Interfaces R5485 RS232 Ethernet ZigBee (optional) Revenue Grade Data ANSI C12 1 Optional(3) € Rapid Shutdown NEC 2014 690 12 E Functionality enabled when SolarEdge rapid shutdown kit is installed' ,,. • STANDAR®COMPLIANCE ,. Safety UL1741, U1_1699B, UL1998 CSA 22 2 1 Grid Connection Standards IEEE1547 ,,. Emissions FCC part15 class B JNSfALLA4LOPI%SPEC IFICATIONS. — AC out ut conduit s¢e /AWG range 3 / 3/4 mini 8 3 AWG - ......,. P.......... ......... ....... ....../4 minimum 16 6 AWG ......... ....... rings ...... DC input conduit size / # of strings / 3 3/4" minimum strings / .:AWG range ................: ....... :: ...: .... /4" minimum / 1 2 strings) 16 6 AWG _ :...:....... 14 6 AWG ......................"' .... .....,,.........,... Dimensions with Safety Switch 30.5 x 12.5 x 7.2/ 775 x 315 x 184 - 30.5 x 12.5 x 10.5/ ............................. 775x315.x260. rpm .. ..... ........ ...pm Weight with Safety Switch•, _ _. •: .. 51.2/23... .._. ,_54.7/24.7.• _ .,. ..,. I 88 .4/401 Ib/kg Natural convection Cooling Natural Convection and internal Fans (user replaceable) fan (user .... i Nreplaceable) ose.,••._. jj <SO ...... ................. ..... < 2.....,, .,..,....I ,.,,._.. Min. Max. Operating Temperature Range... -13 to+140/-25 to+60(-40 to+60 version availableisi) •F/°C Protection Rating ,... • NEMA 3R ....act Sol rEd e support. ...........:............................................................. ....... ' For other regional settings please contact SolarEdg 5upp rt. pi Ahighercurrent sc, r crray be used; the nverterwill l t is input current to the values stated. - o Revenue gade nverter P/N. SE—A-US000NN112 (for 760OW mverter:SE7600A-US002NNR2 Rapid shutdown kit P/N: SE1000-RSD-Sl i psi 40 version P/N. SE—A-US000NN1.141for 760OW nverter.5E7600A-U5002NNU4). USA- GERMANY- ITALY- FRANCE -JAPAN - CHINA - AUSTRALIA - THE NETHERLANDS - ISRAEL WWN/,SOIaredge.US WV ZZU %0Z `6Z HAV :PaUodxa lsel algid a A821 100-6£Sl-000 # luewnoop ,woo•sledsz :sddV pue slualed •aollou lnogllm a6uego of loofgns ale suogeogpadg "asn goea jo; slonpoid s,aelosdoZ;o Rl!I!gelins aql 6up4uan ao; alglsuodsaj Alolos sl aawolsno oql 6lueajem lonpoid eql ul of paaja;ej suogeagpods alos agl salnIgsuoo slonpoid s,aelog daZ glim paddlgs uolleluawnoop lasn-pue ogl'lonpad goea jo; fqueuem lonpoad ueupm all ul pauleluoo sl f4ueuem elos s,uelog deZ "seovues uo slonpoid sll lnoge jo jelog deZ Aq Alueuem ssejdxe Am eleen lou seop luawnoop slgl £OLZ in of palsn woo•jelosdoz L6£ H98 'ON lRd 100:1 6ullana-1 OP' 400-6C%-099 M ZZU MOV6Z HAV :Palyodxe lsel ele0 Q new 100.6C%-oo8 # luewnoop woo sleds :sddV pue slualed aagou lnogllm o6uego of pafgns eje suogeoi;podg asn goea aol slonpoid s,aelogdaZ;o klllgellns aql 6ul6;pan Jo; alglsuodsaJ flaps sl aawolsno eql Glueuem lonpoid aql ul of paua;aa suopeogpads alos eql sa;nppsuoo slonpoid s,aelog daZ gllm paddlgs uogeluamoop aasn-pua ogl'lonpoid pea jo; Rlueuem lonpoid uallum egg ul peuleluoo sl Alueuem eps s jelog deZ •seowas jo slonpoid sil Inge uo jelog deZ Aq kueuem ssejdxe /ue elewo lou seop luewnoop slgl woouelosdoz saolnap 6ufuoq!sod ailM jol 999 � -in of polsg slonpoid luawa6euew aim daZ .,bZ of do sianelpeo pue „ZL of do sueds jol pejeoul6u3 £OLZ In o1 palsll in awe slonpoid 6ulpuoq dwoo SZ L9b In Pue £OLZ "In o1 palsy in ale slonpoid 6ufpuna6 dwoo SZ splepuels M-L pue 90-L 30SV01laodai lauunl puim £OLZ In ied bsd 09 of sainssaad peol mous pue lllldn pulnn alnpow slioddns dwoo SZ suogeluauo adeospuel pue 11e11,od ul sllelsul Slow p9go11d jol peu6lsaa Abolougooi bu11unoW Ad lana-I-lxON slow al6uiys uollisodwoo aol smsg dwo: SZ OFFN aeloSdoZ Aj!DJel0Sf,_ LG NeON-2 LG 315 N 1 C-Z4 .• $ s, LG's new module, NeON— z, adopts Cello technology. Cello technology replaces 3 busbars with 12 thin wires to , enhance power output and reliability. ' NeONYNi 2 demonstrates LG°s efforts to increase customer's values b^ tf ? beyond efficiency. It features enhanced warranty, durability, performance under real environment, and aesthetic design suitable " C for roofs. ®VEON�e Intertek Cello Technology Key Features za/P} Enhanced Performance Warranty rizLG NeONTM z has High Power Output an enhanced performance warranty The annual degradation has fallen i Compared with previous models, the LG NeONTM 2 from-0.7%/yr to-0.6%/yr. Even after 25 ears, y has been designed to significantly enhance the cel(guarantees 2.4%p more output than the previous NeONT"^ modules. its output efficiency making it efficient even in limited space [ _3 Aesthetic Roof J LG NeONT°' 2 has been _ Improved Product Warranty designed with aesthetics in mind; thinner wires that appear all black a i As Well as the enhanced performance warranty at distance. The product can increase the value of a property with its modern design. LG has extended the product warranty of the LG NeONr" z for an additional 2 years. Better Performance on a SunnyDa Y .g Double -Sided Cell Structure" ,Y. LG NeONT" 2 now performs better on a sunny days thanks to its Improved temperature The rear of the cell used in LG NeONTM z will ✓ coefficient. contribute to generation, just like the front; the light beam reflected from the rear of the module is reabsorbed to generate a great amount of additional power. About LG Electronics LG El—er.mrs - !c>ai big player, committed to exp d- g t p t th the solar market Th progra 1985 supported by LG Gmup's vast ex nyfirs[embarked asolar aria gy arch - released "afirst M"on" series to the market, which y d tenals'ndustrie 20l O, L LG - s now ava table in 32 cow ntners he NeON solar AWARD n 2013 and 2015, wh ch demonstrates LG Salars lead, .. L6 S I essfully (Previous MonaX-NeON) and The NeON 2 nn on the'"Inte ova. on and t,mmitment to the industry. Life s Good Y LG315N 1 C-Z4 NN ; LG NeON Tm2 Electrical Properties (STC. ) Mechanical Properties Model = '::urn „.t � � LG315N1-=Z4 rt 11 Hoax 31 s 6 x 1 O -ie11 Vendor - MPP VoCt ge NmPP) Nl :' 33 ' LG Celt 7ype £: e n MPP Curro t llmpp) LA].. .2 9.50 Monocrystallne /N-Type C ll D e on Open C'rc tV Itage{Vod_} [v),: 40.6 156.75 x 156.75 mm / 6 inches $,Mori C'rcu t Current (l ) [A -; ) a. 10.02- 12 (Multi Wire Bulbar) ;O m n, (j_X W H) Module Fffi iency Ll1^ 19.2 I b40 x 1000 x 40 mm front Lod ... .. _ . _ _ _ r8pera[,n9 Temperatur k [ C}. .... ,. -40—+90 2400 Pa Max mutnS F .e )latmg 20 .0 n itdfj+p 18.2 ± 0.5 kg P WerT le ¢ ? s Lam] O 3 t4u LT n BOX' MC4 IP67 with 3 Bypass Ss Diodes (Standard t d r c d ) I d 1000 W/ , Module Temperature 25'C, AM The nameplate power ou puts easured and determined b LG Elettron Y 1.5 " l ` sale and absolute discretion. :GYass 1200 mm X2 ea Wgh Transmission Tempered Glass "Te Anodized Aluminium Electrical Properties (NOCT) Model -( - `y",y; i;G375N1C;24 " Certifications and Warranty - M imtim� pt3riPgf ) j UL 7703 MPP Vo IYa i 4 fV PP, f ;lV} 233 30.7 L7t fie t o s. 4 ' IEC 61 215, IEC 61730-1 /-2 MSC--�V----t ()� P) 7.57 § IS09001 OP Rciicurt Uoltage.(V ) ".'" [V]' 37.7 M elute F Prfronnano lUL) Type 2 Sh"art`G c t Cilmorif Fire Resistance ci ss (IE Class C NOCT(Nommal Operating Cell Temperature) Irradiance 8.06 800 W/m', ambient Lein Prod ct Warranty 12 Ye ars perature 20'C, wind speed 1 m/s O tp t WarrantyFPr -;,fr ... _ Linear Warranty* `.1)lst year98%.z)Am, znd year 0.6%p annual degradaeoq 3) 83.6%for 25 years Dimensions (mm) Temperature Characteristics NOCT;.A to -0.38 Characteristic Curves a ,aao aae 600 ,000w sonW soOW no, aria a•we+l _ 4. 4 eW 2.00 _.... 200W 0.00moO 15:00 20.00.. - - —a € tage (v) 5. 30.00 3500 40.00 4500vol141 o. a _ -- - - U me as _ n -- - -ao -as - 0 25 ' The distance between the center of the mounting/gmunding holes. s 21 peatvre("t) -- LG Electronics lnc LG Solar Rosiness Division S I Square 416, Products ficanons are subject to tanh peel ge without notice. DS Z2 60 C-US F EN 60718 '� ® ® Hangang d ero,dung-gu, 5eou104637, Korea Life's (Mood Igolarcom - ©2016 LG EIectroNcs. All rights reserved. a^ m