Loading...
Subsurface Sewage Disposal System BlueprintO • : � , .. , ' : • PERC ELEV. 8:2.6 •• • - • • • . 38-56" PERC ELEV. 92.5 ,.:... ' • - - : , : • » » l LOAMY SAND •••, - - • •• .. - • • 36 -84 2.5 Y 6/3 ELEV. 8:9.9 Cl 6" - . ' • r • , . • • ••;SYSTEMAiVD" •• • • 77"MOTTLING ELEV. 90.8 • �- MOTTLING ® 84" C2 LOAMY SAND 42"-90" 2.5 Y 6/2 ELEV. 89.70 NATURALLY OCCURING PERVIOUS MATERIAL COARSE LOAMY SAND c OR SAND FILL MEETING .310 CMR 15.255 84»_120" 2.5 Y 7/2 ELEV. 8f6.9 1 COARSE . LOAMY SAND 90"-108" 2.5 Y 7/2 ELEV. 88.2 INSPECTION PORT DETAIL OBSERVED DEPTH TO WEEPING - 96"' OBSERVED DEPTH TO WEEPING - 90" NOT TO SCALE (ELEV. 88.9) (ELEV. 89.7) ESTIMATED DEPTH TO SEASONAL HIGF. .I ESTIMATED DEPTH TO SEASONAL HIGH GROUNDWATER - 84" (ELEV. 89.9) GROUNDWATER - 77" (ELEV. 90.8) SUPPORT NET WOOD FENCE POST � ol � FILTER / CROSS SECTION -NOT TO SCALE / LOT 25 ®s� O.C.MAP 79 v 50 0 �• (SLOPING DISPOSAL AREA MAX. 10) AREA = 9.9 A ORES f - A / . � sdL ski '�` '�` N F '�` NUMBER OF ENVIRO-SEPTIC LINES:4 I --- --' --- ---SPACING: 1.50' d col- i3 ✓AMES S. LEES JR. CENTER TO CENTER �• AL AL ,� AL AL � J � PROP. 40 MIL HDPE PRoPo 1 1 1le SDR.I21 � 1 � MOISTURE BARRIER PVC FORCE MAIN ccl-12 79124 IV/or w z z 0 J_ TOP OF FOUNDATION m ELEV. = 100.0 A MINIMUM OF ONE ACCESS COVER WITHIN 6 INCHES OF FINISH GRADE. /-- ELEV.=97.66t WIRING TO CONTROL PANEL LOCATED INSIDE HOUSE CONTROL PANEL TO HAVE BOTH VISIBLE & AUDIBLE HIGH WATER ALARM. ALARM SHALL BE HARD -WIRED ON A CIRCUIT INDEPENDENT OF PUMP. NO PLUG-IN TYPE ALARMS ARE PERMITTED. 24" CONC. COVER FLUSH W/ GRADE ELEV.=96.83 CONC. RISER AS NECESSARY 3"MIN. SEAL ALL JOINTS WATERTIGHT _ a ' • . ..._,� �' LIFTING PIPE OR 1" GALI PIPE = `• ' SLIDE RAIL & LIFT PIPE _ SLOPE -= 2.0% (MIN.) S=1.074MIN.) 3" MIN. "DIA.PVC PIP INV.=95.65 . 0 LIQUID LEVEL • 4" DIA. PIPE --- 11' 10 14" 'G HIGH WATER INV.= ALARM ON 95.75 PUMPON SEAL ALL CONSTRUCTION - INV.=96.00 � PUMP OFF � JOINTS WITH BUTYL RUBBER EXIST. 4" . OR APPROVED EQUAL INV.=96.5 4'-1" LIQUID DEPTH 48"MIN. 48� TWO COATS FACTORY PVC SANITARY TEE INSTALLw APPLIED WATERPROOFING GAS BAFFLE .a 12 INSTALL 3/8" WEEP HOLE CONTRACTOR TO VERIFY EXISTING s + ; _ FOR FORCE MAIN DRAIN BACK PIPING CONNECTIONS PRIOR TO PLACEMENT OF SEPTIC TANK & » ,, 6" CRUSHED STONE BASE 1 1 /2" SDR-21 PVC PUMP CHAMBER. 6» 6 ON COMPACTED BASE BARNES SE411 PUMP FORCE MAIN 4 _ d SINGLE PHASE OR _ APPROVED EQUAL 6" CRUSHED STONE BASE - 1000 GAL PUMP CHAMBER 0.40 HP 5.12" IMPELLOR NOTE i ON COMPACTED SUBBASE CONTRACTOR TO PLACE GALLON W_ ATER11GHT PRECAST CONCRETE PUMP CHAMBER MAGNETIC TRACE TAPE TO BE INSTALLED ON A LEVEL STABLE BASE. OVER ALL SEPTIC COMPONENTS 1500 GAL PFECAST SET' C TANK WATERTIGHTNESS TO BE VERIFIED PRIOR TO BACKFILUNG INCLUDING BUILDING SEINER, TANK, DISTRIBUTION Box, LEACHING FIELD TANK TO BE INSTALLED ON A LEVEL STABLE BASE PUMPS & PUMP CHAMBER TO BE CONSTRUCTED & INSTALLED AND ALL SYSTEM PIPING. IN ACCORDANCE WITH 310 CMR 15.221, 15.231 & 15.254 ROTONDO MODEL ST 5X10-15 OR EQUAL LENGTH 1 i'-0", WIDTH 6'-0", DEPTH 6".1" 43'f 2' EXISTING GRADE SURROUNDING SAND 5' r - FINAL GRADE - PROPOSED 40 MIL BREAKOUT BARRIER TOP VIEW ENVIRO-SEPTIC PIPE AND BELOW LINES EFFLUENT DISPOSAL AREA •3 - � t iW . �' �, .:� •+ fir.. �`�t o0IIIIIIII' MAX.'4 REMOVE A HORIZON (SEE SOIL LOG) i vv I[ SmAm. I p151ANGt PRECAST CONCRETE (3' PROVIDED)-EQUtgUZERS REQUIRED IN OUTLETS DISTRIBUTION BOX _INSUILATE WITH n� 2" STYROFOAM SECTION THRU SEWAGE DISPOSAL SYSTEM, NOT TO SCALE SIDE VIEW END VIEW sz DESIGN WATER TABLE ELEV.=92.97 BASED ON ADJACENT WATER LEVEL IN WETLAND SYSTEM) SC)L AT�ON LOCH SOIL. LOCI DATE: 12/28/05 DATE: 12/28/05 PROPOSED 4" PERFORATED INSPECTION INSPECTOR: CHRISTOPHER MICHAUD INSPECTOR: CHRISTOPHER MICHAUD PORT WITH THREADED CAP WITHIN 3" SOIL EVALUATOR: RICHARD RICCIO III'.. SOIL EVALUATOR: RICHARD RICCIO III OF FINISH GRADE. PIPE TO BE WRAPPED. TES PIT 1 TEST PST 2 WITH FILTER FABRIC. TOP ELEVATION:��� TOP ELEVATION: _„..97,2 PERC RATE: _7 MI ANCH .� PERC RATE: 6 IN. / NCH_.__ SANDY LOAM ` 0"-12" A 10 YR 3/2 ELEV. 8!;.9 0 .• .... • •' _ - , ' , .. - .....,.... .. 0"-30" FILL ELEV. 94.7 O 90' PVC BEND .. . •::...... '. _ -• -. • • _ • • ,• _ ,,.•.. " B SANDY LOAM LEVEL � .: • .. . ., � • - • • '� - .:.. , � -• • �- • ... ;' -- SANDY LOAM 30"--36" A 10 YR 3/2 ELEV. 94.2 • = � '' - - 10 YR 5 8 ELEV. g: ti.9 SANDY LOAM •.-:..� - • w •'• 4 PVC PIPE ' .,..r.,� • � _'• �; - - 36" 42" B 10 YR 5/8 ELEV. 93.7 `-- OFFSET ADAPTER OFFSET ADAPTER I�TALLATION N07ES: 4" PVC PIPE 1, INSERT PVC PIPE NO MORE THAN 4' INTO THE OFFSET ADAPTER TO PREVENT AIR LOCKING. 90' PVC BEND 2. INSTALL THE RAISED CONNECTION SO THAT THE TOP OF THE 9013END IS LEVEL HATH THE TOP OF 11iE RAISED CONNECTION DETAIL OFFSET ADAPTER. NOT TO SCALE 3. PACK SAND UNDER AND AROUND THE RAISED CONNECTION TO PREVENT MOVEMENT. ~t '04 AL AL AL AL AL PROP. HAY BALE/ won .•�9 SILT FENCE LINE J.A. ✓ENNINGS PROPOSED �, 0 PROPOSED ?' OUTLET PUMP 1000 GALCHAMB �� ` � � � � `.� oisrnieun� BOX ,� ND so r EXISTING CESSPOOL g�`� ' ESSPOOL �"�� � � SHED XISnNG` � �� � � TO BE USED BAFFLE �AS AN TO BE PUMPED � INS'EC110N PORT AND FILLED � � � \ � 1 9 � � � � PROPOSED LOW VENT � � p � ��Q wr �- wq �R (SEE SE''GTION VIEW) PROPOSED ,� � � " � � T � EtE�=92.97 1500 (;AL / O � �`i PROPOSED INSPEC110N SEPTIC TANK *� � � \` �� � \ � - -1 (SEE DETAIL) �hry�cP � 4 �. � t �R� OSED 9.5'x,,�25' ,,t ?�Q-mp-nc �, ..,�. I�AGtilNts AKtA >y �r - � A� y t� (4o-4V ll S / BEDROO 3 . ,�� � �$ i.50� O.C. � � � PROPOSCH�ED 1 Do►FsEzuN� 10.0 ` � � ` � /�C e PVC I�IP � I ECEu. 1o¢o �� � �� � l �� i �� \� EX/S11NG � � � �� � SHED � cc�-s pgSTING s\ i � � � � � �°' i- - SHED / (TO BE REMO 00-00, E)(CftATIAND X `\ / � � / R���� 5' W�'TLAND BUFFER �\ Fxrsnac LOAM AND SUBSOIL �6�c PER �U CM5 15.255 331/12 S.W. CORNER ONCE OP � I / ING =�V• 100 0 (SSUME �g STEP (LANDING) PLAN SCALE: 1 "=20' 1 FABRIC 36 --54 PERC ELE 100 EXISTING CONTOURS /-STAKED 100 PROPOSED CONTOURS / HAYBALE z w BACKFILL "'No o' FLOW NATIVE DESM DATA SOIL NUMBER OF BEDROOMS: THREE DESIGN FLOW PER BEDROOM: 110 GPD. SI LT TOTAL DESIGN FLOW: 330 GPD EEN!QE_..DE TAW CAPACITY 330 GALS. x 200% = 660 GAL. DESIGN CAPACITY USE 1500 GAL. TANK L�CHM AFF.A MOU HUBM DESIGN PERC RATE = 7 MIN./INCH (CLASS 1 SOIL LTAR = 0.68 GAL PER S.F.) MINIMUM SAND BED AREA = 400 S.F. (1) SAND BED AREA PROVIDED: 9.5'x 42.5'=404 S.F. 404 S.F. PROVIDED > 400 S.F. REQUIRED (1) MIN. SAND BED AREA PER PRESBY ENVIRO--SEPTIC WASTEWATER TREATMENT SYSTEM MASSACHUSETTS DESIGN & INSTALLATION MANUAL. PUMP CALCIJLATO SOIL: LOAMY SAND -- CLASS I DOSE RATE: 6 DOSES PER DAY (2) DESIGN FLOW: 330 GPD = 55 GAL./DOSE (2) MINIMUM NUMBER OF DOSES PER PRESBY ENVIRO-SEPTIC WASTEWATER TREATMENT SYSTEM MASSACHUSETTS DESIGN & INSTALLATION MANUAL. DRAIN BACK VOLUME: 43' x 1 1 /2" SDR-21 PIPE = 5f GAL. DOSE VOLUME REQUIRED 55 GAL. + 5 GAL. = 60 GAL. PUMP CHAMBER 1000 GAL., 48" DEPTH BELOW INLET 1000 GAL./48" = 20.8 GAL./INCH DEPTH DOSE VOLUME PROVIDED: 4" = 83 GAL. > 60 GAL. USE BARNES SE411 PUMP 0.40 HP 4.25" IMPELLOR CAPABLE OF PROVIDING 32.5 GPM CAD 13.51 T.D.H. FLOW RATE: 32.5 GPM DOSE VOLUME: 83 GAL., PUMP RUN TIME: 2.6f MIN. VOLUME @ ALARM SETTING (24") w 499.2 GAL. RESERVE VOLUME AVAILABLE = 1,000 GAL. - 499.2 GAL. = 500.8 GAL. > 330 GAL. (REQUIRED) LOCAL UPGRADr= VARLANCESREOUSED i. 310 CMR 15.211(1): MINIMUM SETBACK DISTANCES (50 FEET TO BORDERING VEGETATED WETLANDS [BVW] REQUIRED, 25 FEET PROVIDED; 20 FEET FROM FOUNDATION TO S.A.S. REQUIRED, 10 FEET PROVIDED; 100 FEET REQUIRED TO WELL, 50 FEET PROVIDED) 5 W WATER uNE G GAS LINE UE UNDERGROUND ELECTRIC LINE UTILITY POLE PERC TEST LOCATION 4" PVC SOLID PIPE -_..._._......_...a..-...._ 4" PVC PERFORATED PIPE 1100.0cilPROPOSED SPOT GRADE LOCUS LOCUS MAP NO l TO SCALE 'm �/ 411 //�^•/ 80112-8 Nam. i ` • • MORAN DEV CO. ; i !i • t MAT' 79\OT 25 l AREA 'I: 9.9 AqI''$ = T I �� X ?Z1. 4,S' V !G� ► i or �• _ "' LIT � J / r ,79122 ..- I t l ' EY *"�• So/y2 9 i PAD, 9�?4 • �`7'11�E J�'_ R&94UO & A. MOrORE / N .... M. �IHNlN ..4 8%2-to A/ �; ' < N S.& K. CASSPAR 'Ap 80112 .tID R. PE77EY . S"7W KEY MAP =200' i DL9K)SAL SYSM�i NOTES 2 2/23/09 RRR REVISED PER BOH REVIEW 1. ALL ELEVATIONS ARE REFERENCED TO .THE BENCHMARKS AND DA'7UM NOTED ON THIS PLAN. 1 1/30/09 RRR REVISED PRELIMINARY PLAN PEA BOH REVIEW (2/9/06) 2. ALL CONSTRUCTION METHODS, MATERIALS AND DISPOSAL SYSTEM COMPONENTS MUST 8E IN REV.# DATE BY: DESCRIPTION CONFORMANCE WITH TITLE V OF THE MASSACHUSETTS STATE SMiIiTARY CODE AND ALL REGULATIONS ESTABLISHED BY THE LOCAI. BOARD OF HEALTH. RESERVED FOR BOARD OF HEALTH USE. 3. PERCOLATION TESTS AND TEST PITS LOGS ARE ONLY INDICATIVE GAF THE CONDITIONS OBSERVED AT THEIR LOCATION. SHOULD SOIL CONDITIONS BE FOUND DIFFERENT AT OTHER LOCATIONS WITHIN -THE LEACHING AREA, THE ENGINEER AND THE LOCAL BOARD OF F:lEALTH MUST BE CONSULTED. 4. PRIOR TO PLACEMENT OF ANY FILL AND/OR LEACHING AREA CON,i?pr1ENTS, THE BASE OF THE EXCAVATION MUST BE INSPECTED AND APPROVED BY THE LOCAL BOARD OF Hf:'pL7H AND/OR ENGINEER. 5. EXCAVATE ALL UNSUITABLE MATERIAL BELOW THE BASE OF. AND '5 FEET AROUND THE LEACHING AREA TO THE MINIMUM DEPTH NOTED ON SOIL LOG OR AS OIRECTTEp BY THE LOCAL BOARD OF HEALTH AND/OR THE ENGINEER. REPLACEMENT MATERIAL TO BE IN ACCORIDANCE WI'ti-I 310 CMR 15.255. i 6. ALL FILL MATERIAL SHALL BE CLEAN GRANULAR MATERIAL FREE ('ROM IRONS, CLAY AND FINES AND MUST COMPLY WITH THE REQUIREMENTS OF TITLE V AND APPROVhi_p BY THE LOCAL BOARS of HEALTH. 7, THE FINISH GRADE OVER THE DISPOSAL SYSTEM MUST CONFORM TO THE GRADES SPECIFIED AND IN NO RESERVED FOR BOARD OF HEALTH USE. CASE BE LESSTHAN10" ABOVE THE TOP OF THE ENVIRO-SEPTif.^, PIPE. 8. THE INSTALLED FACILITIES MUST BE LEFT EXPOSED UNTIL INSPECTD BY REPRESENTATIVE OF THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 9. ALL PIPING OUTSIDE OF THE DISPOSAL AREA SHALL BE WATER Tii„HT. 10. UNLESS OTHERWISE SPECIFIED HEREIN, NO GARBAGE GRINDER SHA1LL BE ALLOWED WITH THIS SYSTEM. 11, DESIGN ENGINEER ASSUMES NO LIABILITY FOR DAMAGES AS A RE;a^ULT OF FAULTY CONSTRUCTION OR ANY DEVIATION'OR ALIGNMENT AND GRADE SPECIFIED HEREIN Wlii LOUT PRIOR NOTIFICATION AND APPROVAL OF. THE DESIGN ENGINEER. 12. SYSTEM INSTALLER TO FIELD VERIFY LOCATION AND ELEVATIONS f,?F EXISTING PIPING CONNECTIONS PRIOR TO PLACEMENT OF NEW SYSTEM COMPONENTS. REPORT Qi^_.CREPANCIES TO .DESIGN ENGINEER. 13. THE CONTRACTOR SHALL CALL "DIG SAFE" AT.1-800-a22-4844,, AT LEAST 3 WORKING DAYS PRIOR P.E. s SUBSURFACE SEWAGE DISPOSAL SYSIFEM TO CONSTRUCTION TO INFORM THE UTILITY COMPANIES OF EXCAVipnpN, Ioill H Z iF frf4Ss 14. THE LEACHING FIELD SHALL CONSIST OF A PRESBY ENVIRO-SEPTryC SAND BED* a�� q°y APPLICANT: DAVE CHARPEN11ER o RICHARD R. 15. CONSTRUCTION AND OPERATION OF SYSTEM TO MEET MASS. DEP REMEDIAL USE CERI1FlCAl10N � RICCIO Ill m ASSESSORS MAP & LOT: 79/25 FOR: PRESBY ENVIRO-SEPTIC LEACHING SYSTEM, (AS GRANTED N,�AY 2006 AND MODIFlED IN DULY 2Q07.) �� .--``-.�11!!L� � �c TA�A/1AOIJIf%At AAIfl CVICTkI/� /�AAIMTAIJC CI IDVCV DC{?CC1plIGil rOV CI['1 A CAIP_IAiCCD1Al/] PA IAli1 lAI A� '9e� `^-�, ��� � .i STREET LOCATION 16. TOP R r�Y DECEMBER 2005 AND JANUARY 2006. 17. VALID WETLAND LINE FOR SUBJECT PREMISES ESTABLISHED UNDE;' •,0 AN GRAD (DEP SE 15-1836 FOR ANRAD l F 1� �,� , ALE ENGINEERING FIRM: FILED FEBRUARY 9, 2005) ISSUED APRIL 7, 2005 BY THE TOWN {OF DARTMOUTH CON. COM. = - .- 18. SUBJECT PREMISES IS LOCATED IN A FEMA FLOOD ZONE A (AREAS of 100 YEAR FLOOD) PER FEMA 1 / S. TA P� = COMMUNITY PANEL MAP NUMBER 250051 0005 B REVISED JUNE �1, 1983 AND PER FEMA COMMUNITY PANEL �.; � MAP NUMBER 250051 0015 . B REVISED JUNE 19 1983. MAP �r 19. PROPERTY LINES ARE AS SHOWN ON A PLAN ENTITLED "PLAN 0I' LAND IN DARTMOUTH, MA. PREPARED FOR 75 PINE ISLAND ROAD DARTMOUTH, MA RELD �N�'[i�dEEQNC� CONSUL-'ING ENGINEERS HAZEL THOMPSON", DATED FEBRUARY 21, 1986, AND PREPARED (BY ARTHUR C. THOMPSON, INC., ENGINEERS1�"s & SURVEYORS. ;--- DATE: 01 24 06 SCALE: 1" = 20' .% 20.- ALL WELLS WITHIN 200' OF THE PROPOSED SYSTEM ARE SHOWN (ON THE SITE PLAN, WELL LOCATIONS WERE w.��--:.. RICCIO III P.E. TAKEN FROM AN ON THE 'GROUND SURVEY AS WELL AS RECORD AT E OWN of DARTMOUTH CONTACT PERSON. RICHARD R, . DRAWINGS THE T ADDRESS: 11 D INDUSTRIAL DR11/E, P.O. BOX 1178 AND BOARD OF HEALTH (WHERE AVAILABLE). M ATTAP OI SETT, MA 02739 TEL: (508) 758-2749 FAX: 508 758--2849 „ DRWN BY: RMS CHK BY: RRR SHEET: { OF 1 PROJECT#: 1'750 t